Filtration manager for automatic calculation of corrected differential pressure measurement in refuelling applications

Similar documents
800 Displaying Series Flowmeter

Quick Setup Guide for IntelliAg Model NTA

CARLO GAVAZZI Automation Components

Modular Lube Lubrication Systems System Controls

Experiment 7: Bit Error Rate (BER) Measurement in the Noisy Channel

Application Note 11 - Totalization

Table of contents 1. INTRODUCTION GENERAL CONTENTS OF PACKAGE GENERAL USE OF THE EQUFLOW 6100 D/A CONVERTER STORAGE..

Quick Setup Guide for IntelliAg Model CTA

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

BER MEASUREMENT IN THE NOISY CHANNEL

Transmitter Interface Program

GREAT 32 channel peak sensing ADC module: User Manual

APM CALIBRATION PROCEDURE Rev. A June 3, 2015

Short Manual. ZX2 Short Manual.doc Page 1 of 12

Herzlich Willkommen Bienvenue Welcome. General Basics JUMO Screen Recorders. Manfred Schleicher

WELDING CONTROL UNIT: TE 450 USER MANUAL

Operating instructions Electronic preset counter Type series 717

DANGER WARNING CAUTION

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

medlab One Channel ECG OEM Module EG 01000

FOUR CHANNEL USB RECORDER PCRU01. User manual. Table of Contents

Log-detector. Sweeper setup using oscilloscope as XY display

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

Getting Started with the LabVIEW Sound and Vibration Toolkit

ex 800 Series ematrix System

TriLIN Program Utility TPU_ TriLIN Programming Manual

WV-NP1004. Network Operating Instructions. Network camera. Model No. (Lens is option.)

Network Camera Operating Manual

EVD-L04/100A1-960, EVD-L08/200A1-960 and. EVD-L16/400A1-960 DVRs. Quick Operation Guide

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

Programming instructions Software Version 5

Quick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B

Training Note TR-06RD. Schedules. Schedule types

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Digital Video Recorder

Operating Instructions

Software Manual Control Panel for Professional Single Booster Units Models: MM3 BW3

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

FRQM-2 Frequency Counter & RF Multimeter

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

Welcome. Explanation of Counter-, Integrator- and Operating time counter function of the LOGOSCREEN 500 cf. Dipl.-Ing. Manfred Schleicher

LED-DEC W07 REMOTE DISPLAY WIRELESS DECODER

EDL8 Race Dash Manual Engine Management Systems

TOOLS AND TEST EQUIPMENT REQUIRED

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

Electrical connection

127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) (800) (бесплатно на территории России)

Data Acquisition Using LabVIEW

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1.

Electrical connection

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Portable Data Recorder HMG Operating Manual (Original Manual)

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

PYROPTIX TM IMAGE PROCESSING SOFTWARE

DX-10 tm Digital Interface User s Guide

Operating Manual. Comparator V7 / V8. Hardware and Software. Document Version A. Doc. No.: OM_PCE_VGL_ V7_ V8_v1.023_EN_A_ext.doc

MT03A Electronic converter for flow rate transmitters

VIDEO GRABBER. DisplayPort. User Manual

Electrical connection

Knocking detector device DENOX 2, DENOX 20. User guide. HW & SW versions, December 2006

E X P E R I M E N T 1

JD725A Cable and Antenna Analyzer - Dual Port

ProVu PD6000 Process Meter

Blown Film Extrusion. Line Control. 5 Layers CD Series IBC Temperature USER MANUAL

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

MTL Software. Overview

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

Process Transmitter RMA 422

Auxiliary states devices

D-Lab & D-Lab Control Plan. Measure. Analyse. User Manual

ZU 251. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

EAN-Performance and Latency

DataSAT ACU-2 Controller Wiring Configuration - Operation

DPS Telecom Your Partners in Network Alarm Management

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

OPERATION MANUAL OF MULTIHEAD WEIGHER

Digital differential Pressure switch Model DPS Instruction manual

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output

TransitHound Cellphone Detector User Manual Version 1.3

Ambient NH 3 monitor APNA-370 Instruction Manual CODE:GZ

Quick Operation Guide of LTN7700/7600 Series NVR

Ambient SO 2 /H 2 S monitor APSA-H370 Instruction Manual

OptoFidelity Video Multimeter User Manual Version 2017Q1.0

OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE.

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

CM-392-Video to HDMI Scaler Box ID#481

TF5 / TF3 / TF1 DIGITAL MIXING CONSOLE. TF StageMix User's Guide

IPM500D. Belluno / Italy September 2015

CI-218 / CI-303 / CI430

IV 251. Signal Converter SSI => Analogue and SSI => Serial. Operating Instructions. control motion interface

Boonton 4540 Remote Operation Modes

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Software Ver

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

Transcription:

Page: of: 0 Filtration manager for automatic calculation of corrected differential pressure measurement in refuelling applications FAUDI Aviation Sensor GmbH, Scharnhorststraße 7 B, D-560 Stadtallendorf ization_rev.doc

Page: of: 0 Synchronisation of sensor signals DPGUARD s essential functionality relies on incoming sensor signals from dp transmitter and flow meter to mathematical correlate and calculate corrected differential pressure values. Mathematical correlation is performed in millisecond time frame. Therefor precision of readout highly depend on synchronization of incoming sensor signals. In most cases signals of different physical sources do not have the same behavior. They tend to completely differ with regard to their time response. But if correlated signals are not proper synchronized very bad results for corrected dp during changes in velocity are the result. The common way to synchronize different incoming signals is the use of delay and attenuation times. But how effective could this be done without the knowledge about signal behavior. Realizing the difficulty of synchronization forced us to implement the below described tool to analyze and synchronize incoming sensor signals. DPGUARD software does have a special synchronization feature where you could do a signal analysis combined with a proposal of recommended numbers for delay and attenuation time for both sensor signals (red curve represents flow signal, blue chart represents dp transmitter signal, Td / Ta are proposed numbers for delay and attenuation times to be used in setup for each sensor signal): Following procedure describes on how to synchronize sensor signals together with fundamental information according physical cabling of sensors. FAUDI Aviation Sensor GmbH, Scharnhorststraße 7 B, D-560 Stadtallendorf ization_rev.doc

Page: of: 0. Installation and initialisation of sensor signals J405 S0 J404 J40 J40 J40 S0 5 6 5 6 5 6 5 6 5 6 5 6 5 6 5 6 7 8 7 8 7 8 7 8 7 8 7 8 7 8 7 8 J05 DPGUARD need to have information about flow and differential pressure across installed filter elements. This normally comes from electronic devices like differential pressure transmitters and flow meters. Both signals should be connected to DPGUARD and must be configured during installation process. + + LED60 + + 0/4..0mA 0/4..0mA 4 4VDC 0/4..0mA CAN-H CAN-L AO0 AO0 X9 AO0 DO DO0 DO/M DO09 DO0/M DO08 DO09/M DI0 DO08/M DI0 DO04 DO0 4VDC AI07 Dp connector 4VDC 6 X0 X7 5 PE 4 X KSK70_V0_LP8800.pcb Pulse In 4 7 X7 5 8 LAN 4VDC USB 4 X5 X 4VDC X8 X6 X6 4 POWER cdp out 5 6 7 8 ALARM 0/4..0mA 4 X5 READY X4 WARNING 4VDC X4 Analog (res) DP / P Inlet X 4 4-0mA P Outlet X Flowmeter AI06 4VDC AI05 4VDC 4 5 AI04 4 5 6 7 8 9 0 4VDC X X Flow connector Picture: Terminal Area - Look into DPGUARD FAUDI Aviation Sensor GmbH, Scharnhorststraße 7 B, D-560 Stadtallendorf ization_rev.doc

Page: 4 of: 0. Electrical setup.. Pressure sensor ② Connector for outlet pressure sensor ① Connector for inlet pressure sensor or Differential pressure sensor Picture of connection board pressor sensor connectors Elaboration of terms on pressure sensor screen: ① ② Connector for differential pressure sensor or single inlet pressure sensor. Connector for single outlet pressure sensor (use only if ① is single inlet pressure sensor)... Cabling - Connection to differential pressure transmitter Please refer to original manual delivered together with differential pressure tranmsitter Example shows the installation of one differential pressure transmitter DP. Please make sure to use a barrier if required for hazardous area zone installation! FAUDI Aviation Sensor GmbH, Scharnhorststraße 7 B, D-560 Stadtallendorf ization_rev.doc

Page: 5 of: 0.. Flow meter Connection of flow signal coming from flow meter ③ Flow sensor for current or pulsed signal input...cabling - Connection to flow sensor Example shows the cabling for a pulsed flow signal coming from the flow meter. In case of current signals for flow transmitters please use the 0/4 0mA connector instead of Pulse in. Please make sure to use a barrier if required for hazardous area zone installation! FAUDI Aviation Sensor GmbH, Scharnhorststraße 7 B, D-560 Stadtallendorf ization_rev.doc

Page: 6 of: 0. Settings - Setup in DPGUARD software Step by step explanation on how to set up sensor signals in DPGUARD setup menu Press setup button on main screen Type in - Administrator password 45678 (to only set up sensor settings) or SERVICE password 7487 to also go into signal analysis - press Enter button Example shows procedure under SERVICE password level You reach DPGUARD setup menu level Press Sensor Input button to enter sensor submenu Now you are in Sensor Input submenu to define settings for pressure and flow rate sensor. First action: Pressure Sensor Press Pressure button to enter Pressure Sensor submenu FAUDI Aviation Sensor GmbH, Scharnhorststraße 7 B, D-560 Stadtallendorf ization_rev.doc

Page: 7 of: 0 You need to adjust: ) Mode of Sensor: - xdp: differential pressure or - xp two pressure sensors (one for inlet and one for outlet pressure ) Signal quality: - 0 to 0 ma or - 4 to 0 ma ) Max. pressure range of pressure sensor (refer to calibration protocol) 4) Delay / average of pressure sensor Please refer to operation manual for sub item to Delay / average of pressure sensor should be adjusted to synchronize the sensor signal together with another sensor signal that should be in time with pressure sensor signal. Please do setup for both sensors (dp and flow sensor) in front of any setup for delay or attenuation! Go back to address flow sensor. Press Flow Rate to address Flow Rate Sensor. You need to address: ) Mode of Signal - 0 to 0 ma or - 4 to 0 ma or - Pulse signal ) Max flow rate (only important if current sensor is installed) ) Delay / average of flow rate sensor Please refer to operating manual for sub items and FAUDI Aviation Sensor GmbH, Scharnhorststraße 7 B, D-560 Stadtallendorf ization_rev.doc

Page: 8 of: 0 Go back to sensor Input submenu to address signal analysis Input Signal Analysis: Go back to Sensor Input Submenu and press Input Signal Analysis button Now you are in Input Signal submenu where you need to do settings for signal analysis. You will be asked to setup: - Start/Trigger Flow: - do not change the value - Time Interval: You can go down to 0 sec to better visualize the analysis effects - Display max flow: dependent on what you can reach during test - Display max. pressure: dependent on element behaviour during test Recommended settings for a vessel of 500 Liter/min rated flow and new Monitor elements (see settings) Change settings by pressing each button to be changed. If changes are proceeded, press Signal>> button to enter chart for signal analysis Now you are in signal analysis mode. Press RESET button to reset numbers You will find: Red chart curve representing flow rate signal Blue chart curve representing dp signal Blue and red colour values for Td and TA, representing proposed values for Delay (d) and attenuation (a) Numbers on axis are with regard to settings in setting signal Analysis submenu. FAUDI Aviation Sensor GmbH, Scharnhorststraße 7 B, D-560 Stadtallendorf ization_rev.doc

Page: 9 of: 0 How to proceed a signal analysis: You need to run your system on a test rig or you can either use the function under real operating conditions. ) Press Reset in front of any flow change ) Counter will start and changes in dp and flow will be displayed. ) Signal analysis stops fully automated when counter pre-set time is over (0 sec in example above) 4) Proposed settings for delay and attenuation are displayed beside axis of dp and flow Result: Td = 0,0 Sec Ta =, Sec Td = 0,7 Sec Ta = 0,0 Sec Write down numbers and go back into Sensor Input submenu to set up delay and attenuation values You can leave signal analysis screen by pressing somewhere onto the active field Adjust proposed numbers for delay and attenuation for pressure and flow rate sensor Pressure sensor Flow rate sensor Now you are ready with the setup of signal synchronisation. If you want to run signal analysis again press Reset button to reset counter In case of already existing pre-set s for delay and attenuation please add proposed numbers and go back to check for plausibility (e.g. run an additional signal analysis test). FAUDI Aviation Sensor GmbH, Scharnhorststraße 7 B, D-560 Stadtallendorf ization_rev.doc

Page: 0 of: 0 FAUDI Aviation Sensor GmbH, Scharnhorststraße 7 B, D-560 Stadtallendorf ization_rev.doc