PROJECT INFORMATION PROJECT DOWNLIGHT DATE TYPE 1" 2-1/2" BeveLED Recessed Downlight - Illuminate your space with any color available in the spectrum with BeveLED Infinite Color+. Tune the light from saturated blue, violet, green, yellow, orange, and red, to any of a wide variety of perfect architectural whites with DMX512 controls. Infinite opportunities abound for hospitality, entertainment, and cultural lighting applications, or any other project requiring full color and white light flexibility. 1" 2-1/2" 2 1 2" 1" Bevel Finish Color area Flange Finish Color area HOW TO SPECIFY Ordering Example: Specify trim code and housing code to order: Example : W - B1- SF - 10 - LSTD4-9032 - WRGB1-30KS - 60 - NC - 277V - DMX1M - RJ - CB27 TRIM ORDERING INFORMATION TRIM OPTION BEVEL STYLE Square Downlight 1" or 2-1/2" W Wet location 1 EML Integral Emergency Test Switch 2 TZ TechZone (NCSM only) 1 Wet location, use with B1 and B2 trims only. 2 Use with NC housings only. B1 1 Bevel, Painted Die Cast Matches Flange Finish AB1 1 Bevel, Black Anodized AC1 1 Bevel, Clear Matte Anodized B2 2-1/2 Bevel, Painted Die Cast 3 Matches Flange Finish AB2 2-1/2 Bevel, Black Anodized 3 AC2 2-1/2 Bevel, Clear Matte Anodized 3 3 Not for use with NCSM housing. LENS SF SF Solite Frosted (provided standard) FLANGE FINISH 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) Relative Output (W/nm) 1 0.8 0.6 0.4 0.2 0 400 Spectrum 450 500 550 600 650 700 wavelength (nm) Independently mix white light with color in any combination imaginable to create a uniquely personal light source. 750 HOUSING ORDERING INFORMATION HOUSING CODE LSTD4 ENGINE PRIMARY WATTAGE CODE WHITE REFLECTOR HOUSING TYPE 9032 WRGB1 30KS 30KS - VOLTAGE DIMMING CABLING ACCESSORIES LSTD4 9032 32W LED, 1375 Lumen Maximum WRGB1 60 60 beam NC New Construction 3000K, 80+ CRI 80 80 beam NCSM Narrow Width CP Chicago Plenum IC Insulation-Contact Rated / Airtight See emergency solutions chart for EM options with these housings 120V 277V DMX1M EldoLED DMX 0.1% dimming, manual addressing using RDM protocol, 8 bit DMX2M EldoLED DMX 0.1% dimming, manual addressing using RDM protocol, 16 bit RJ RJ45 Jacks WR Splice Connection XL XLR5 Connectors 5 5 Requires above ceiling access; N/A with IC or CP housings. CB27 27 C-Channel Bars CB52 52 C-Channel Bars EML Emergency battery 6 EMLW Emergency battery, wet location 6 TZ TechZone ceiling compatible 7 6 For use with NC housings only. 7 With NCSM housing only 2016., LLC.
DOWNLIGHT TRIM INFORMATION 1" EM fixtures that are provided with an integral test switch are shipped with a hole in the glass lens for access. Refer to EMERGENCY SOLUTIONS chart to find out which fixtures have an integral test switch. 2-1/2" 2 1 2" 1" - TechZone Compatible 5 13 16" x 5 13 16" 1" Bevel Finish Color area (B1, AB1, AC1) Flange Finish Color area (10, 13, 21, 28, RAL) Emergency Solutions EM Integral Remote Inverter Housing SERVICE Test Switch Test Switch By Others NCSM N/A X NC Through aperture X NC Wet Location Through aperture X CP N/A X IC N/A X HOUSING INFORMATION New Construction Universal Style Housing - NC Chicago Plenum - CP IC / Airtight - IC 7 7 /16 8 5 /8" New Construction - Narrow Footprint, Slide Mechanism - NCSM 8 3 /8" 4 3 /4" 5 3 /4" 1-2 3 /16" 19" (Plan View) 22(Plan View) 2016., LLC.
DOWNLIGHT SPECIFICATIONS TRIM: 4-1/2" square aperture with a 1" regressed bevel and 1/2" flange, retained by two mounting clips. Die cast aluminum bevel is self-flanged and is available in white, statuary bronze, black, and metalized grey finishes. Also available in black or clear matte bevel, with painted flange. 2-1/2" regress available for maximum glare control. Custom color flanges available (provide RAL#). TRIM LENS: Trim is shipped with integral frosted solite lens standard. REFLECTOR: Interchangeable precision injection molded reflector optimized for 60 or 80 beam distribution. FIELD REPLACEABLE LIGHT ENGINE: Available in 1 lumen package: typical power draw is 23 input watts with 1150 delivered lumens. Maximum power draw is 32 input watts with up to 1375 delivered lumens. Engine is field replaceable through the aperture without tools. COLOR: BeveLED is capable of creating any color desired in the spectrum, from saturated blue, violet, green, yellow, orange, and red, to a wide variety of architectural whites. All color change is digitally controlled through the DMX interface of your choice. RATED LIFE: Based on IESNA LM80-2008 50,000 hours at 70% lumen maintenance (L70). THERMAL MANAGEMENT: Proprietary high performance aluminum die cast heatsink for maximum LED life. Ambient temperatures at fixture location should not exceed 40 C during normal operation. FIELD REPLACEABLE DIMMING : Solid state electronic constant current DMX512 8-bit driver with a high power factor provided standard. Specify 120V or 277V. Driver complies with IEEE C62.41 surge protection. Specify DXM1M for 8-bit communication controls; specify DMX2M for 16-bit communication controls. All driver options require remote device management (RDM) communication protocol for addressing. CABLING: The DMX512 driver is provided with two twisted pair cabling for connection with communication controls. Data cables must be run in series between fixtures. Choose your preferred method of connection when specifying. To avoid signal transmission problems, a DMX link terminator should be used in the last fixture in a series. NOTE: Communication cables and AC power lines must not be run in the same conduit. RJ Cabling Option: fixture is provided with a DMX512 interface board inside the junction box with RJ45 jacks for use with CAT5 cable terminated with RJ45 connectors. For fixtures with RJ45/CAT5 connections, the following ANSI/TIA/EIA-568 pin out standard is used. Link termination dip switch is provided at the connector board; no separate link termination device is required. See dimming compatibility pages for drawings and more details on this configuration. WR Cabling Option: no interface board is supplied; cables must be spliced inside the junction box for connection. The data cable used must meet the following requirements: type: shielded, 2-conductor twisted pair maximum capacitance between conductors: 30 pf/ft maximum capacitance between conductor and shield: 55 pf/ft maximum resistance: 0.02 ohms/ft normal impedance: 100-140 ohms conductive core: 24 AWG is recommended If 3-wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Do not use standard microphone cables: they cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device (by others) should be used on last fixture in line on a circuit to avoid signal loss. EMERGENCY: Fixtures provided with an integral test switch are provided with a hole in the glass lens as per the drawing above. Fixtures provided with a remote test switch are provided with a 24 lead length for location of the test switch. Fixtures that have no EM option may be connected to an inverter (by others) for emergency lighting. See emergency solutions chart for more information on EM test switches and servicing. MOUNTING: Butterfly brackets and adjustable nailer bars with integral nails provided. Nailer bars are extendible from 14 to 24 centers. HOUSING: All-Ways Square (covered by US Pat. No: US 7,832,889) housing allows alignment of square aperture (up to 20 rotation) after housing installation and prior to finish ceiling installation. Fabricated of 20 ga. galvanized steel with thru wire J-box, 4 in 4 out at min. 90 C, #12 AWG thru branch circuit wiring. NCSM with TZ option is compatible with TechZone ceiling systems. NCSM housing can NOT be used with thru-branch circuit wiring. MAXIMUM CEILING THICKNESS: As per drawings above. CEILING CUT OUT: 5-1/16" x 5-1/16" LISTINGS: Dry/Damp. *Wet location option available with B1 trim only. NRTL/CSA-US tested to UL standards. IBEW union made. WARRANTY: 5 years NOTES: Not for use in corrosive environment. Use of pressure washer voids warranty. PHOTOMETRICS: Consult factory or website for IES files. Tested in accordance with IESNA LM79-2008. XL Cabling Option: fixture is provided with a DMX512 interface board on the junction box with standard 5-pin XLR5 jacks which accept XLR5 connectors for DMX communication. Any standard XLR cable can be used for this option. Link termination dip switch is provided at the connector board; no separate link termination device is required. NOTE: This cabling option requires above ceiling access. 2016., LLC.
Termi nati on BeveLED DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY SELECTION GUIDE DMX1M, DMX2M DMX1M: EldoLED DMX dimming with manual addressing, 8-bit (Dims down to 0%) DMX2M: EldoLED DMX dimming with manual addressing, 16-bit (Dims down to 0%) Choose from WR (splice connection), RJ (RJ45 jacks) and XL (XLR5 connectors) cabling options, and refer to corresponding wiring diagram below: RJ CABLING OPTION RJ-45 CONNECTORS CAT 5 CABLE 4 3 DMX (-) 2 DMX (+) 1 BLUE GREEN/ WHITE ORANGE ORANGE/ WHITE BLUE / WHITE GREEN BROWN / WHITE 5 6 7 BROWN 8 ON OFF ON OFF TURN ON DIP SWITCH TO TERMINATE LAST FIXTURE ON DMX BUS V- WR OPTION BLUE WHITE - V- V- WR Cabling Option: no interface board is supplied; cables must be spliced inside the junction box for connection. The data cable used must meet the following requirements: type: shielded, 2-conductor twisted pair maximum capacitance between conductors: 30 pf/ft maximum capacitance between conductor and shield: 55 pf/ft maximum resistance: 0.02 ohms/ft normal impedance: 100-140 ohms conductive core: 24 AWG is recommended If 3-wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Do not use standard microphone cables: they cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device (by others) should be used on last fixture in line on a circuit to avoid signal loss. XL CABLING OPTION NOTE: This cabling option requires above ceiling access. 5 PIN XLR CONNECTORS MALE FEMALE On Off XLR CABLE TERMINATION 1-1/8" TURN ON DIP SWITCH TO TERMINATE LAST FIXTURE ON DMX BUS 1.-10" XLR CONNECTORS WHEN XLR5 IS SELECTED LEAVE CLEARANCE FOR J-BOX TO SLIDE TO APERTURE 4.75" V- 2014., LLC. I2-265
DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY SELECTION GUIDE DMX1M, DMX2M DMX MUST BE DAISY CHAINED IN SINGLE CORRECT! INCORRECT! NOTES FOR S: 1. DMX signal cable must NOT be run in same conduit as high voltage AC power lines. 2. Fixtures must be daisy chained in one serial line using Data in and Data out 3. Maximum of 32 DMX devices on a single DMX bus 4. Maximum of 1600 ft serial communication link distance 5. To avoid signal loss, DMX signal terminator should be used on last fixture in line. For RJ and XL cabling options, this is provided through a dip-switch on the connector board. For WR cabling options, this device (120 ohm resistor) is provided by others. 6. For best results when using WR cabling option use communication data splices. 7. Default state for fixtures off. Luminaire will not light until DMX signal is received. 2014., LLC. I2-265