COLORSCAN. Technical and economical proposal for. DECOSYSTEM / OFF.A419.Rev00 1 of 8. DECOSYSTEM /OFF A419/09 Rev November 2009

Similar documents
In-process inspection: Inspector technology and concept

Remote Director and NEC LCD3090WQXi on GRACoL Coated #1

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

STB Front Panel User s Guide

CardModule. Reference Manual. Series C DA Channel SDI to CVBS Converter. Version 1.0

VSP 198CVS Quick Start

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

VSP 168HD Quick Start

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Scalable, intelligent image processing board for highest requirements on image acquisition and processing over long distances by optical connection

LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94

HEAD. HEAD VISOR (Code 7500ff) Overview. Features. System for online localization of sound sources in real time

General Specifications

ROBOT- GUIDANCE. Robot Vision Systems. Simple by Design

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Winmate Communication INC.

EDDYCHEK 5. Innovative eddy current testing for quality and process control. Touchscreen. Networking. All major applications.

SMARTSCAN 100% Inspection System

Operating Instructions

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

microenable 5 marathon ACL Product Profile of microenable 5 marathon ACL Datasheet microenable 5 marathon ACL

SIWAREX FTA Weighing Module for High Accuracy Requirements Calibrating SIWAREX FTA with SIWATOOL FTA

SportReplay Multichannel Video Recording and Instant Replay system

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

VSP 516S Quick Start

3G/HD/SD-SDI to HDMI Converter

9I273 01/10/2012 COU-03/0 AUTOMATIC CHANGEOVER UNIT TO BACK-UP AMPLIFIER

6.4 Chassis Monitor Model Number: LCM0642xx. SPEC No.: SAS Version: 0.0 Issue Date: April 16, Introduction:

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

User Manual TP70L. HDBaseT Extender. All Rights Reserved. Version: TP70L2016V1.1

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

IMPAC Infrared Thermometers

microenable IV AS1-PoCL Product Profile of microenable IV AS1-PoCL Datasheet microenable IV AS1-PoCL

CAPTURE CAPTURE. VERSiON 1.2. Specialists in Medical. Digital Imaging Solutions

MAP Optical Power Meter Module (mopm-b1)

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

microenable IV AD4-LVDS Product Profile of microenable IV AD4-LVDS Datasheet microenable IV AD4-LVDS

SV-LCD50. Installation and User Guide. Thin-Film Transistor (TFT) Liquid Crystal Display (LCD) Color Rear Vision Monitor. Version 1.

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

16-BIT LOAD CELL/DUAL STATUS INPUT

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

Product Profile of microenable 5 VQ8-CXP6D ironman

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

LG Electronics Monitor Proofing System with LG W2420R Display and Adobe Acrobat 8 Professional for GRACoL Coated #1

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

USER GUIDE FOR NETmc MARINE X-Ops

microenable IV AD1-PoCL Product Profile of microenable IV AD1-PoCL Datasheet microenable IV AD1-PoCL

True RMS AC/DC Mini Clamp Meter

PQ Labs Multi-Touch Screen G 2 Overlay

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

H.264. Mobile DVR 4CH

The measurements are stored in non-volatile memory, which retains data even when the power down.

Re: ENSC 370 Project Physiological Signal Data Logger Functional Specifications

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Processor time 9 Used memory 9. Lost video frames 11 Storage buffer 11 Received rate 11

DT9837 Series. High Performance, USB Powered Modules for Sound & Vibration Analysis. Key Features:

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

DM1624, DM1612, DM812

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

AZ DISPLAYS, INC. COMPLETE LCD SOLUTIONS SPECIFICATIONS FOR 15.0 OPEN FRAME MONITOR

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Major Differences Between the DT9847 Series Modules

ksa ScanningPyro ksa ScanningPyro Full Carrier Temperature Maps at the Click of a Button!

Progressive Scan CCD Color Camera KP-FD30M. Specifications ( Revision.1 )

Agilent N6465A emmc Compliance Test Application

medlab One Channel ECG OEM Module EG 01000

DB-x20 Digital Billboard

3G/HD/SD dual channel audio embedder/de-embedder

FLAT DISPLAY TECHNOLOGY

EM1. Transmissive Optical Encoder Module Page 1 of 9. Description. Features

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

New GRABLINK Frame Grabbers

VGA to DVI Extender over Fiber SET

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

EAN-Performance and Latency

MX215. Your advantages. 2MP Medical-Display

Real-Time PCR System TC

Function Manual SIMATIC HMI TP900. Operator Panel.

AVE HOME FAGOR CVBS TO DVB-T ENCODER MODULATOR. Fagor Electr6nica

MN9320A. Optical Channel Drop Unit. Independent Test Access Tool for Comprehensive DWDM Measurements

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

RMS 8424S Quick Start

FLIR Daylight and Thermal Surveillance (P/T/Z) Multi-Sensor systems

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

VISION SCANNER2. Next Level Imaging. Simple by Design

Tender Notification for the procurement of a Scanning Electron Microscope" at IISc (Last Date for submission of tenders: 3 rd October 2018)

User s ManUal NON-CONTACT TACHOMETER. Please read this manual carefully and thoroughly before using this product.

EXT-HBT70-SET_2016V1.2

We bring quality to light. SNT 10 DC Power Supply

Series 1100 ColorTS Servo Manual Registration System

specification hyperion colorimeter

specification hyperion colorimeter

VISION SCANNER2. Next Level Imaging. Simple by Design

PicoScope 2000 Series PC Oscilloscopes

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

Transcription:

via G. da S. Giovanni, 50141 Firenze - Italia tel: 055 45448- fax: 055 455453 C.f./ PI 05151485 A/3, Virwani Industrial Estate, Tel : 022 282 8040 - Fax: +1 22 28 20 Technical and economical proposal for COLORSCAN DECOSYSTEM /OFF A41/0 Rev.00 0 November 200 DECOSYSTEM / OFF.A41.Rev00 1 of 8

via G. da S. Giovanni, 50141 Firenze - Italia tel: 055 45448- fax: 055 455453 C.f./ PI 05151485 A/3, Virwani Industrial Estate, Tel : 022 282 8040 - Fax: +1 22 28 20 INDEX INDEX... 2 INTRODUCTION... 3 GENERAL FEATURES OF COLORSCAN... 3 System standard features... 3 Different configurations of Colors can... 3 COLORSCAN - B1... 4 COLORSCAN B3... 4 COLORSCAN T3... 4 COLORSCAN FULL... 5 SetUp of Colorscan T3... 5 Tolerances... Report... INPUT AND OUTPUT... Encoder... Input signal... Output signals... SYSTEM COMPOSITION... Composition of COLORSCAN T3... ACQ - acquisition unit... PRU - Processing unit... MCU Mouvement device... Colorscan T3 Software Package... User manual... Back Up disk... TECHNICAL DATA CHARACTERISTIC OF COLORSCAN - T3... 8 Technical Data of Colorscan T3... 8 PRICES... System... Start Up and training... TOTAL PRICE... Exclusion... GENERAL CONDITIONS OF SALE... Prices... Tva... Testing... Packing... Shipment expenses and insurance policy... Payment... Terms of delivery... Installation and training... Exclusion... Certification... According to the laws in force.... Warranty... Intellectual ownership... Software license... Jurisdiction... Offer validity... DECOSYSTEM / OFF.A41.Rev00 2 of 8

via G. da S. Giovanni, 50141 Firenze - Italia tel: 055 45448- fax: 055 455453 C.f./ PI 05151485 A/3, Virwani Industrial Estate, Tel : 022 282 80408 - - Fax: +1 22-22 28-28 20-20 pureindia@sify.com COLORSCAN Spectrophotometer for differential colorimetry INTRODUCTION Dear Sirs, following our previous contacts we are pleased to submit a technical-economic proposal for the supply of COLORSCAN, the innovative spectrophotometer for inline application. Hereby we are going to describe the configuration of our system COLORSCAN could be installed on your printing machine GENERAL FEATURES OF COLORSCAN System standard features The Colorscan standard features are: Unique Lighting system with seven different LED sources All operations can be carried out using the touch screen Easy to learn and easy to use GUI interface Fast and automatic set up (new job can be started in a minute) Great reliability in the detection of color variations Full report and automatic storing of all production process data Operating in Windows XP Different configurations of Colorscan Colorscan can be provided in four different configurations. Each configuration is suitable for a different in-line application: DECOSYSTEM / OFF.A41.Rev00 3 of 8

via G. da S. Giovanni, 50141 Firenze - Italia tel: 055 45448- fax: 055 455453 C.f./ PI 05151485 A/3, Virwani Industrial Estate, Tel : 022 282 8040 - Fax: +1 22 28 20 COLORSCAN - B1 SPOT MEASUREMENT Colorscan B1 measures the color difference ( E, CIELAB 1) between acquired samples and one color previously stored. The acquisition of each sample is triggered by an external signal. The spot of the reading area is about 1mm. COLORSCAN - B1 PROFILE MEASUREMENT Colorscan B3 measures the color differences ( E, CIELAB 1) between acquired arrays of colors (or colour profiles) and one array previously stored. Each profile measurement is triggered by an external signal. The length of the colour profile is configurable. The points where color differences are measured in the profile are also configurable. COLORSCAN T3 PROFILE MEASUREMENT WITH TRASVERSAL MOVEMENT As in Colorscan B3, the Colorscan T3 system measures color variations between profiles of colors. The color sensor is moved and the transverse position of the measured color profile can be varied. The system can store several positions and color profiles. DECOSYSTEM / OFF.A41.Rev00 4 of 8

via G. da S. Giovanni, 50141 Firenze - Italia tel: 055 45448- fax: 055 455453 C.f./ PI 05151485 A/3, Virwani Industrial Estate, Tel : 022 282 8040 - Fax: +1 22 28 20 COLORSCAN FC SPOT MEASUREMENT WITH TRASVERSAL MOVEMENT AND CAMERA Colorscan FC can measure color differences in any points on a surface compared to any number of stored colors. The system can memorize multiple positions; for each position a different color can be stored. The system is equipped with a color camera that helps the operator setting the test positions. In the following we describe the configuration of COLORSCAN T3 model. Colorscan Software The software is easy to use and user-friendly and it doesn't require any particular experience in PC usage. Set-up operation for the product's change are automatic: the operator has nothing more to do except inputting or recalling the client - and/or product-code; A new Job setup procedure is composed of a few simple steps: - Setting Job parameters such as: number of reading points, length of color profile, distance of the profile from the trigger, number of colors. - Setting the coordinate of the position of the Instruments - Acquisition of the color profile. - Storing of data with product-code. DECOSYSTEM / OFF.A41.Rev00 5 of 8

via G. da S. Giovanni, 50141 Firenze - Italia tel: 055 45448- fax: 055 455453 C.f./ PI 05151485 A/3, Virwani Industrial Estate, Tel : 022 282 8040 - Fax: +1 22 28 20 TECHNICAL DATA CHARACTERISTIC OF COLORSCAN Reflectance sensor with multi-spectral bands: this characteristic guarantees a higher measurement accuracy than traditional RGB instruments Insensitivity of ambient light effects: thanks to a dynamic calibration of the black reference, the instruments doesn't suffer any interferences by ambient light. The installation of the device it is easy because it doesn't require a particular cover screen. Only direct sunlight on the measurement area has to be avoided Optical density measurement: the instruments provides the reflectance optical density at 45/0 geometry.. Internal reading frequency up to Khz: this frequency guarantee a very fast reading rate, up to times more than any existing instruments. The device can measure two consecutive marks of 1mm up at the speed of 300m/min... Color measurement: the instruments provides the color measurement following t h e C I E 1 3 1 r e c o m m e n d a t i o n s ( 4 5 / 0 g e o m e t r y ). Color display following CEI 131and 1 recommendations: the instruments represents color measurements following the CEI specifications, with D5 standard illumination and standard observer at 2 degree, in the color spaces device inndependent - XYZ and L*a*b*. Color display in other color spaces: the instruments can provide color measurement estimations in device dependent color spaces such as RGB and CMYK. For better results the user can provide his color profile for a customized calibrations of color output. Technical Data of Colorscan Sensor multi spectral band Field of view of the camera (only FCmodel) 0mm Max profile length 20mm Max number of colors for profile Number of position 20 Speed (max) 300 m/min max Control time (max) 0ms Resolution 1mm spot Control L*a*b color variation Minimum detectable color variation 0,2 delta E Minimum detectable OD variation 1% OD Safety UPS Operating With touch screen interface DECOSYSTEM / OFF.A41.Rev00 8 of 8

via G. da S. Giovanni, 50141 Firenze - Italia tel: 055 45448- fax: 055 455453 C.f./ PI 05151485 A/3, Virwani Industrial Estate, Tel : 022 282 8040 - Fax: +1 22 28 20 Tolerances Dedicated tolerances can be assigned independently to each position of the job and to each color of the profile. The tolerances on color variations can be set in units delta E or separately in delta L, delta a, delta b. Password-protected menus allow selective access to the system and tolerance set-up can be restricted to appointed personnel. Report Data about the controls, defects and any other and real time information on the ongoing production can be made available in form of reports or data file. The reports with the analysis of the detected errors can be graphically or digitally printed, they can be filed and transferred to a host computer. INPUT AND OUTPUT Encoder An encoder signal is necessary to synchronize the acquisition with the speed of the machine. Input signal The standard input and output are the following: Start acquisition: signal that start the image acquisition Output signals When COLORSCAN detects a faulty piece a dedicated KO signal is given In case of consecutive defects or in case of many defects an alarm signal is given to stop the printing machine. System On: this signal is enabled when the COLORSCAN is in control Alarm: this signal is enabled In case of consecutive defects or in case of many rejections Alarm: this signal is enabled In case of consecutive defects or in case of many rejections DECOSYSTEM / OFF.A41.Rev00 of 8

via G. da S. Giovanni, 50141 Firenze - Italia tel: 055 45448- fax: 055 455453 C.f./ PI 05151485 A/3, Virwani Industrial Estate, Tel : 022 282 8040 - Fax: +1 22 28 20 SYSTEM COMPOSITION Composition of COLORSCAN The system consists of three different parts: a processing unit (PRU), a mechanical and electronic movement devices (MCU) and an acquisition unit (ACQ). ACQ - acquisition unit o Mechanical box containing the color sensor head o Color sensor head at Khz o Encoder (5.000 pulse/revolution) o Camera (Only the FC model) o Connection cables between the processing unit and the acquisition unit PRU - Processing unit o Rack containing electric and electronic parts o P4 Vision hardware module, operating in Windows XP environment o USA-ASCII keyboard and mouse o I/O Interface o LCD 1 Monitor (Touch screen) o UPS MCU Mouvement device (only for T3 and FC models) o Bosh Rexroth Module eckk 1 420mm stroke o o Stepper motor IDS1 Drive Ball Screw Assembly In addition: Colorscan Software Package Software package operating in Windows XP User manual User and maintenance manual in English Back Up disk Back up disk for damage recovery