Migatronic Tig - Plasma Welding machine /Fanuc robot Interface. Adapted for RJ3 Controller: Adapted for RJ2 Controller:

Similar documents
DX-10 tm Digital Interface User s Guide

FOM-9010, FOM-9011 and FOM-9012

3-in 1- out DVI Switcher

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

Specification Type 1.1 Interface

SERIES 400 SERIES 620

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Digital 4 Q - Servo amplifier for brushless DC Servo motors (Trapeze)

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

Automation Interface Requirements for J602 Basic I/O Interface of a DPC 4 Welding System

Cable guide. for. High Performance Controllers and TeleControllers. Cable types and wiring guidelines

Bill of Materials: Super Simple Water Level Control PART NO

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

USER GUIDE. DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version DM Engineering

Product Specifications

APPLICATIONS. Automatic warehouse. Trasportation lines

SPACESCAN SERIES SS 02

VGA AUDIO SWITCHER S MANUAL

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

ex 800 Series ematrix System

ASF 1x32 AV 3/1 xxx Blueline ASF 1x32 AV 3/1 xxx Light ** ASF 1x24 AV 3/1 xx Econom

New KRONOS 500 Kronos 500

Temposonics. Magnetostrictive Position Sensors. L Series (Model LH) to G-Series Linear-Position Sensor. Cross Reference A

Operating instructions Electronic preset counter Type series 717

Foreword: The purpose of this document is to describe how to install and configure Neets 4 relay box

ST60-DVC VTR CONTROLLER ST60-AG57 VTR CONTROLLER

PHOX TM. Camera Link Fiber Extender. Base Configuration KEY FEATURE APPLICATIONS PHOX-BM PHOX-BL-10/20/40/50

CG-1 CAMERA-GUARD INSTRUCTION BOOK IB647501

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

AF-300 E11 Adjustable Frequency Drive

LAUREL ELECTRONICS, INC.

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

AUTOMATIC VIDEO LOSS A/B SWITCH

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

PHOX TM. Camera Link Fiber Extender. Dual Base Configuration KEY FEATURES APPLICATIONS PHOX-B2M-250 PHOX-B2L-10/20/40/50

SIMATRIX NEO V2 Modular Video Matrix

2x2 HDMI Matrix Switch - 4K with Fast Switching and Auto-Sensing

USER'S MANUAL. Getting started with ALEXAN ATMEL AT89C2051/AT89C4051 Training Module - 1

Noise Detector ND-1 Operating Manual

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Quick Operation Guide of LTN7700/7600 Series NVR

RLS Series RLS-GD-20/20 -UV. Design. RLS-GD Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

EL-41AT. 4 in, 1 out v1.3 HDMI Switcher with Independent Audio OPERATION MANUAL

Multi-Key v2.4 Multi-Function Amplifier Keying Interface

4-in-1 Motor Controller CAN

FOM-1090 FOM-1090 FOM FOM-1090 w/ DB-25 Female FOM-1091 w/ DB-25 Male

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

FB10000 Error Messages Troubleshooting

Camera Setup Instructions

2-Port HDMI Automatic Video Switch - 4K with Fast Switching

V1602 / V1602CP. ANALOGUE VIDEO ROUTER - 16x2. Rev. 6

PART 1: HARDWARE. Author: Vandermeerschen M. Version

Infrared Over CAT5/6 Extender. Model: IR-EXT3. Operation Manual

LED Interior Lighting Sets Instruction Manual (380mm)

CLOCKAUDIO. MR88 Automatic Microphone Mixer. Version 4.2

APPLICATIONS. Automatic warehouse. Trasportation lines

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

TELEDYNE HASTINGS INSTRUMENTS

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

DM1624, DM1612, DM812

Quick Setup Guide. DCX-500i / DCX-1000i / DCX-1500i Projectors with WC-Pro Scaler. Preliminary

SBL Series Wireless Clock Installation Manual (V2) Table of Contents

HDMI Over IP Extender Kit - 4K

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Material: Weight: IP Rating: Cable: Connector:

AES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter

P P S - M W S C A N 1 H

SPECIFICATION NO Model 207 Automatic GTAW Welding System

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

QUICK START GUIDE FLEXSLICE MODULES

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

Contactors and Contactor Assemblies

VGA AUDIO AUDIO MATRIX SWITCHER S MANUAL

Rack mounted telephone- and leased line modem for industrial applications

GP-500 SERIES - Low Voltage

Pen and Multichannel Recorder: Digital Display

Directional Couplers and Splitters

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

ARC HEIGHT CONTROL (ARC VOLTAGE CONTROL) MODEL : HAC-01-A-1M

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Photoelectrics Through-beam Type PA18C.T..., DC

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

263 Series LED Bargraph Indicator and Controllers

Model No. ST100 VTR CONTROLLER

6.4 Chassis Monitor Model Number: LCM0642xx. SPEC No.: SAS Version: 0.0 Issue Date: April 16, Introduction:

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

PRELIMINARY. Orbis CU. Preliminary Data Sheet!

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM

LinTronic. TableTop series. Hardware version 6. Updated

DMC550 Technical Reference

Transcription:

Migatronic Tig - Plasma Welding machine /Fanuc robot Interface Adapted for RJ3 Controller: 76119997-1 Adapted for RJ2 Controller: 76119999-1 Setup & Jumper configuration AUTOMATION A/S +45 96 96 27 00 U:\RS_INTFS\WORD\OPSTILL.DOC 29/04/2011 15:48 PH/CL 1 / 22

Table of Contents: JUMPERS.... 3 LED INDICATORS... 4 CONNECTIONS IN FRONT OF THE INTERFACE.... 5 CONNECTIONS ON BACKSIDE OF THE INTERFACE.... 7 INTERFACE SCHEMATIC... 8 ACCESSORIES... 9 ILLUSTRATION 1: THE WELDING MACHINE GIVES THE ARC DETECT SIGNAL THROUGH THE COLD WIRE FEEDER... 11 ILLUSTRATION 2: THE WELDING MACHINE GIVES THE ARC DETECT SIGNAL THROUGH THE COLD WIRE FEEDER... 12 ILLUSTRATION 3: THE WELDING MACHINE GIVES THE ARC DETECT SIGNAL... 13 ILLUSTRATION 4: THE WELDING MACHINE GIVES THE ARC DETECT SIGNAL... 14 ILLUSTRATION 5: THE ARC DETECTOR BOX GIVES THE ARC DETECT SIGNAL.... 15 ILLUSTRATION 6: THE ARC DETECTOR BOX GIVES THE ARC DETECT SIGNAL.... 16 ILLUSTRATION 7: THE ARC DETECTOR BOX GIVES THE ARC DETECT SIGNAL.... 17 ILLUSTRATION 8: THE ARC DETECTOR BOX GIVES THE ARC DETECT SIGNAL.... 18 ILLUSTRATION 9: THE AC/DC ARC DETECTOR BOX GIVES THE ARC DETECT SIGNAL THROUGH THE COLD WIRE FEEDER... 19 ILLUSTRATION 10: THE AC/DC ARC DETECTOR BOX GIVES THE ARC DETECT SIGNAL THROUGH THE COLD WIRE FEEDER... 20 ILLUSTRATION 11: THE AC/DC ARC DETECTOR BOX GIVES THE ARC DETECT SIGNAL.... 21 ILLUSTRATION 12: THE AC/DC ARC DETECTOR BOX GIVES THE ARC DETECT SIGNAL.... 22 U:\RS_INTFS\WORD\OPSTILL.DOC 29/04/2011 15:48 PH/CL 2 / 22

Jumpers. 1 2 3 Jumper 2 (J2) 1 2 3 Jumper 3 (J3) 3 2 1 Jumper 1 (J1) J1: Arc detect mode, only 8 pole plug. 1&2: Low on pin E =arc on 2&3: High on pin E = arc on J2: Supply for 8911 remote control. 1&2: Wire feeder supplies the remote control 2&3: Welding machine supplies the remote control J3: With/without remote control. 1&2: Remote control installed 2&3: No remote control U:\RS_INTFS\WORD\OPSTILL.DOC 29/04/2011 15:48 PH/CL 3 / 22

Led indicators. 1 6 2 11 12 7 9 10 4 5 3 8 Pos.1: Pos.2: Pos.3: Pos.4: Pos.5: Pos.6: Pos.7: Pos.8: Pos.9: Pos.10: Pos.11: Pos. 12: Current output signal, PWM signal (Yellow) Wire speed output signal, PWM signal (Yellow) Start welding input from robot (Yellow) Start wire/wire on input from robot (Yellow) Wire + input signal from robot (Yellow) Wire input signal from robot )Yellow) Arc on signal from 6 pole plug, input signal (Yellow) Arc on signal from 8 pole plug, input signal (Yellow) Start welder output signal (Red) Start/wire on, output signal (Red) Arc on, output signal to the robot (Red) +24V DC from robot OK (Green) U:\RS_INTFS\WORD\OPSTILL.DOC 29/04/2011 15:48 PH/CL 4 / 22

Connections in front of the interface. 1 2 3 4 1: Start wirefeeder / welding machine output. Via this connector, the KT-4 wire feeder is started. This connector also can supply the interface with the Arc Detect signal. Pinconnections: 2: Relay output. Start welding machine or wire feeder. 3: Arc Detect signal. Input to interface. 5: 0V / Gnd. 6: Relay output. Start welding machine or wire feeder. Other pins not connected. 2: Connection to welding machine s remote input. This plug should only be connected if no wire feeder is connected. Pinconnections: A: Current information 0-10V to welding machine. B: 0V/GND (REF.0V) E: Arc Detect signal from welding machine. 0V = Arc ON. G: Supply voltage. Voltage = 18VAC or 24VAC, depending on welding machine. H: Supply voltage common. Other pins not connected. U:\RS_INTFS\WORD\OPSTILL.DOC 29/04/2011 15:48 PH/CL 5 / 22

3: Connector to KT4 wire feeder. Pin connections: A: Current information 0-10V DC. From interface to welding machine. B: 0V/GND (REF.0V). C: Wirefeeder ground/ connected to the chassis in wirefeeder. D: Direction signal wire. 0 = wire forward. 1 = Wire return. E: Start wire request from wirefeeder. Output from KT-4 wire feeder. F: Start wire: Input on KT-4 wire feeder. 0 = Stop wire. 1 = Start wire. G: +24V / DC to remote control. Max. 200mA. Short circuit protected. H: 0V / GND to remote control. M: Wirespeed information 0 to 10V. From remote control to wire feeder. V: Interface ground / connected to chassis in interface. Other pins not connected. 4: Connector to remote control from interface. Remote control type 8911 can be used. Pin connections: A: Current information 0-10V DC. From interface to welding machine. B: 0V/GND (REF.0V). C: Wirefeeder ground/ connected to the chassis in wirefeeder. D: Direction signal wire. 0 = wire forward. 1 = Wire return. E: Start wire request from wirefeeder. Output from KT-4 wire feeder. F: Start wire: Input on KT-4 wire feeder. 0 = Stop wire. 1 = Start wire. G: +24V / DC to remote control. Max. 200mA. Short circuit protected. H: 0V / GND to remote control. J: Enable Basis Current. A 0 on this input, will force the remote control to enable basis current. A 1 will enable the remote control to carry out it s normal procedure. K: 0V/GND. L: 0V/GND. M: Wirespeed information 0 to 10V. From remote control to wire feeder. N: Wire +. 0 = Jog wire. P: Wire -. 0 = Jog wire direction. R: Disable puls current. 0 = No current pulsation. S: Disable step wire. 0 = Constant wire. 1 = Wire when current is high. T: Wire speed information 0 to 10V, from robot. U: Current information 0 to 10V, from robot. V: Interface ground / connected to chassis in remote control. Other pins not connected. U:\RS_INTFS\WORD\OPSTILL.DOC 29/04/2011 15:48 PH/CL 6 / 22

Connections on backside of the interface. 1 Pin numbers and names in parenthesis refer to connectors on a Fanuc robot s RJ2 or RJ3 controller. 1: Welding current + (CRW1-23, WDO1). 2: Wire speed + (CRW1-3, DACH2). 3: NC. 4: 0V / Ground in robot (CRW1-20, GND). 5: Arc Detect output from interface to robot (CRW1-6, WDI2). 6: Disable pulse current (CRW1-28, WDO6). 7: Wire +, jog wire forward (CRW1-26, WDO4). 8: Start weld (CRW1-23, WDO1). 9: Welding current (CRW1-2, CAMDA1). 10: Wire speed (CRW1-4, CAMDA2). 11: Enable basis current (CRM2B-33, SDO1). 12: +24VDC from robot (CRW1-34, +24VE). 13: Disable step wire (CRW1-29, WDO7). 14: Wire -, jog wire backward (CRW1-27, WDO5). 15: Start wire (CRW1-25, WDO3). All inputs to the interface via this connector, except analogue inputs, requires NPN open collector output type, or relay contact - switching to 0V. All outputs from the interface via this connector, are NPN open collector type. U:\RS_INTFS\WORD\OPSTILL.DOC 29/04/2011 15:48 PH/CL 7 / 22

Interface Schematic U:\RS_INTFS\WORD\OPSTILL.DOC 29/04/2011 15:48 PH/CL 8 / 22

Accessories 6 pole cable between RS interface and arc detector box. The cable must be full connected. Male / female. Length standard 3 meters. No. 74341020-1 6 pole cable between RS interface and cold wire feeder. The cable must be full connected. Male / male. Length standard 5 meters. No. 74341021-1 6 pole cable. Start welding machine. Male / male. Only pin 2 & 6 is connected. Length standard 5 meters. No. 74320002-1 8 pole cable between RS interface and welding machine. The cable must be full connected. Length standard 5 meters. Male / male. No. 74340003-0 19 pole cable between RS interface and cold wire feeder. Also used between RS interface and 8911 remote control. Length standard 6 meters. The cable must be full connected. Male / male. No. 74341011-1 Remote control 8911 Controls welding current, cold wire speed and pulse timing. No. 76118911-1 Arc detector box. Usable only for DC welding Detects current > 20A No. 76118817-1 U:\RS_INTFS\WORD\OPSTILL.DOC 29/04/2011 15:48 PH/CL 9 / 22

76118818-1 WIRE FEEDER GROUND WELDING MACHINE WELDING + Arc detector box. Can also be used for AC welding Detects current > 5A No. 76118818-1 19-Pin plug with bridges. Use when the system is equipped with wire feeder, and NOT equipped with remote control. No. 17210090-1 22 U:\RS_INTFS\WORD\OPSTILL.DOC 29/04/2011 15:48 PH/CL 10 /

Illustration 1: The welding machine gives the arc detect signal through the cold wire feeder. RS interface jumpers: J1: 2&3, J2: 1&2, J3: 1&2 Plasma commander DC, Tig Commander/Navigator DC. It can be necessary to apply PTC1 in the control unit on the welding machine (Analogue machines only). 11/22

Illustration 2: The welding machine gives the arc detect signal through the cold wire feeder. RS interface jumpers: J1: 2&3, J2: 1&2, J3: 2&3 Plasma commander DC, Tig Commander/Navigator DC. It can be necessary to apply PTC1 in the control unit on the welding machine (Analogue machines only). Note! 19-Pin plug (part no.17210090-1), must be inserted in the remote control connector, at the interface. 12/22

Illustration 3: The welding machine gives the arc detect signal. RS interface jumpers: J1: 1&2, J2: 2&3, J3: 1&2 Plasma commander DC, Tig Commander/Navigator DC. It can be necessary to apply PTC1 in the control unit on the welding machine (Analogue machines only). 13/22

Illustration 4: The welding machine gives the arc detect signal. RS interface jumpers: J1: 1&2, J2: 2&3, J3: 2&3 Plasma commander DC, Tig Commander/Navigator DC. It can be necessary to apply PTC1 in the control unit on the welding machine (Analogue machines only). 14/22

Illustration 5: The arc detector box gives the arc detect signal. RS interface jumpers: J1: 2&3, J2: 1&2, J3: 1&2 Pilot 1600/2400, BDH Tig. DC welding only. It can be necessary to remove wire E in the 8 pole Cable between the welding machine and the cold wire feeder. 15/22

Illustration 6: The arc detector box gives the arc detect signal. RS interface jumpers: J1: 2&3, J2: 1&2, J3: 2&3 Pilot 1600/2400, BDH Tig. DC welding only. It can be necessary to remove wire E in the 8 pole cable between the welding machine and the cold wire feeder. Note! 19-Pin plug (part no.17210090-1) must be inserted in the remote control connector at the interface. 16/22

Illustration 7: The arc detector box gives the arc detect signal. RS interface jumpers: J1: 2&3, J2: 2&3, J3: 2&3 Pilot 1600/2400, BDH Tig. DC welding only. It can be necessary to remove wire E in the 8 pole Cable between the welding machine and RS interface. 17/22

Illustration 8: The arc detector box gives the arc detect signal. RS interface jumpers: J1: 2&3, J2: 2&3, J3: 2&3 Pilot 1600/2400, BDH Tig. DC welding only. It can be necessary to remove wire E in the 8 pole cable between the welding machine and RS interface. 18/22

Illustration 9: The AC/DC Arc detector box gives the arc detect signal through the cold wire feeder. RS interface jumpers: J1: 1&2, J2: 1&2, J3: 1&2 Plasma commander AC/DC, Tig Commander/Navigator AC/DC. It can be necessary to apply PTC1 in the control unit on the welding machine (Analogue machines only). 19/22

Illustration 10: The AC/DC Arc detector box gives the arc detect signal through the cold wire feeder. interface jumpers: J1: 1&2, J2: 2&3, J3: 2&3 Plasma commander AC/DC, Tig Commander/Navigator AC/DC. It can be necessary to apply PTC1 in the control unit on the welding machine (Analogue machines only). Note! 19-Pin plug (part no.17210090-1) must be inserted in the remote control connector at the interface. 20/22

Illustration 11: The AC/DC Arc detector box gives the arc detect signal. interface jumpers: J1: 1&2, J2: 2&3, J3: 1&2 Plasma commander AC/DC, Tig Commander/Navigator AC/DC. It can be necessary to apply PTC1 in the control unit on the welding machine (Analogue machines only). 21/22

Illustration 12: The AC/DC Arc detector box gives the arc detect signal. interface jumpers: J1: 1&2, J2: 2&3, J3: 2&3 Plasma commander AC/DC, Tig Commander/Navigator AC/DC. It can be necessary to apply PTC1 in the control unit on the welding machine (Analogue machines only). 22/22