DPM 942-FPSI 4-20mA Loop Meter with Programmable Backlighting

Similar documents
Model IQ4-PC User Manual Revision Date:

TRIMBLE GPS / 10MHz REFERENCE MONITOR DISPLAY V January 2015

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

263 Series LED Bargraph Indicator and Controllers

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

HS-509 VIBRATION TRIP MODULE

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

SCALE & WEIGHT DISPLAYS

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

Operating Instructions

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Micro-DCI 53ML5100 Manual Loader

LAUREL ELECTRONICS, INC.

IEFIS G3 Inputs, outputs and Alarms

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

N3ZI Digital Dial Manual For kit with Serial LCD Rev 3.04 Aug 2012

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown then fax: 44 (0)

DCP100 Digital Control Programmer Specifications

FRQM-2 Frequency Counter & RF Multimeter

SAUTER flexotron RDT405 Manual

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

We put you first. And keep you ahead. USES FEATURES. Bulletin SS09040 Issue/Rev. 0.2 (10/14)

INT-X-P and INT-X-L Programming instructions

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Analog/digital watch Multi frequency reception, 4 digit LCD, 3 hands. Preliminary Specification

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

Programmable Room Thermostat With RF

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

N3ZI Digital Dial Manual For kit with Backlit LCD Rev 4.00 Jan 2013 PCB

Safety FIND THE FEED CABLE IN YOUR ELECTRICITY METER (UK)

STX Stairs lighting controller.

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS.

SI-510 DUAL TRIP AMPLIFIER

Standard signal metering in wall-mounting case

FIELD MOUNTED RATE TOTALISER MODEL 202D

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

AVMU2-BHD+/3G Audio monitoring Unit

Wall-/Pipe-Mount Level Indicator

MICROMASTER Encoder Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Electronic converter for level transmitters MT03L Instructions manual

ProVu PD6000 Process Meter

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

Registers type ILR7XX and ILR7XXT

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

SHOWLINE SL BEAM 100 LED LUMINAIRE SPECIFICATIONS.

1900/25 Vibration Monitor

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Process Transmitter RMA 422

SHOWLINE SL PAR 155 LED LUMINAIRE SPECIFICATIONS.

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

OWL micro+ WIRELESS ELECTRICITY MONITOR

DRAFT RELEASE FOR BETA EVALUATION ONLY

+GF+ SIGNET 8860 Dual Channel Conductivity/Resistivity Controller

NV Series PA Modification for Improved Performance in FM+HD and HD Modes

EXA PH200/400 and EXA PH202/402 Troubleshooting and Error Code Guide

SHOWLINE SL PUNCHLITE 220 LED LUMINAIRE SPECIFICATIONS.

BMW12N-H NTV-KIT791. Kit Contents. BMW12N-H Interface. Interface Power Harness

Set Point Controller OC557. Operator s Manual

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1.

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Xtreme Power Systems RFU. Installation And Usage Manual. Firmware v1.1. Manual v1.1. Revision Date: June 5 th, 2014

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions

Entry Level Wind System. English Français Deutsch Nederlands Espagñol Italiano

CARLO GAVAZZI Automation Components

RL3-PCM41. Compatible with Porsche Panamera from MY 2017 with PCM4.1 infotainment and 12.3inch monitor

7 SEGMENT LED DISPLAY KIT

2.4GHZ Digital Wireless Reversing Camera Kit

BMW12N-DYNAMIC KIT NTV-KIT717

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

AMU1-BHD+ Audio monitoring Unit

2291 Guided Wave Radar Level Transmitter

K3NX Process Meter OPERATION MANUAL

21 Channel Light Show PWM LED Controller with Remote Control

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

TC3005(LED/ELED/LASER) User's Manual

2002 Martin Professional A/S, Denmark.

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

Transcription:

4-0mA Loop Meter with Programmable Backlighting ORDERING INFORMATION Standard Instrument (panel meter, fixing kit, data sheet) DPM 94-FPSI FEATURES 9mm (0.7 ) digit height Dual colour backlight with programmable status indication Open collector outputs that mirror the backlight status (with inverted output option) V supply voltage 4 0mA measurement range The DPM 94-FPSI is a ½ digit LCD current loop meter that can also be used for dual colour go-stop status indication. This functionality is ideal for simplifying monitoring applications, where an operator needs to know the status of the equipment at a glance. During standard operation the backlight is green, however if the reading goes beyond the user programmable thresholds, the display will turn red. Three open collector outputs are included, that indicate high, ok and low conditions. Both the backlight colour and outputs can be inverted. Module setup is a simple operation using an eight-way DIP switch and two push buttons. No special tools or equipment are required. SPECIFICATIONS Minimum Typical Maximum Unit Accuracy (overall error) 0.0 0. % (± count) Linearity ± count Sample rate samples/second Hysteresis (high and low thresholds) counts Operating temperature range 0 () 0 () C ( F) Temperature stability 00 ppm/ C Supply voltage 4.. V Supply current (not including backlight) ma Backlight voltage V Backlight current 40 ma Specifications liable to change without prior warning Issue 04/ S.L Applies to DPM 94-FPSI Page of

PIN FUNCTIONS. Negative current loop input. I+ Positive current loop input. Negative supply connection 4. V+ Positive supply connection. LP+ Positive backlight connection 6. ALM HI Open collector alarm output. Goes low when the high threshold of the module has been passed. 7. ALM OK Open collector alarm output. Goes low when the module is measuring a signal between the high and low thresholds. 8. ALM LO Open collector alarm output. Goes low when the lower threshold of the module has been passed. 9. SW- Negative switch input for flashing backlight acknowledgement. 0. SW+ Positive switch input for flashing backlight acknowledgement. LCD SYMBOLS Err Return dip switches to to the off position. Only of theses switches may be in the on position at a time.! The unit is in set-up mode. To view the measured signal, ensure switches to are in the off position. DIMENSIONS All dimensions in mm (inches) Specifications liable to change without prior warning Issue /0 S.L Applies to DPM 94-FPSI Page of

DIP SWITCH CONFIGURATION ON 4 6 7 8. Enter offset calibration mode. Enter span calibration mode. Enter high threshold setup mode 4. Enter low threshold setup mode. Enter decimal place setup mode 6. Invert alarm operation 7. Invert outputs 8. Select backlight supply OFFSET AND SPAN CALIBRATION Calibration is performed in two steps. The first step is to adjust the offset value. The second is to adjust the span. To adjust the offset, move DIP to the on position and input a known constant current (typically 4mA). By default, 000 will be displayed. The user can then use the push buttons mounted on the rear of the device to adjust the value on the display. Pressing the up button once will increase the value on the LCD by one count. Pressing the down button once will decrease the value on the LCD by one count. If either button is held down, the value will continuously change until the button is released again. When the desired value is on the display, return DIP to the off position. To adjust the span, move DIP to the on position and input a known current (typically 0mA). By default 000 will be displayed. The value can then be adjusted in the same way as the offset. THRESHOLD SETUP There are two independent thresholds on the unit which control the backlight colour and open-collector outputs. The high threshold is triggered when exceeded by the input signal and the low threshold is triggered when the input signal drops below it. Both thresholds can be set, enabled and disabled independently. By default the backlighting is green when an input is normal and red when the input exceeds a threshold (see INVERT BACKLIGHT COLOURS for more information). The thresholds can be set to any value between -999 and 999, however, it is not possible to assign a value to the low threshold which exceeds that of the high threshold and vice versa. In addition to numerical values, it is also possible to set both values to an over range condition. This will only trigger the backlight when the input goes beyond a value that can be displayed. To adjust the threshold calibration: First select a position on the miniature DIP switch, mounted on the reverse of the module. Moving position to on will display the high threshold value Moving position 4 to on will display the low threshold value When a threshold is selected, it can then be adjusted using the two push buttons mounted on the rear of the device. The thresholds are adjusted as shown overleaf. Specifications liable to change without prior warning Issue /0 S.L Applies to DPM 94-FPSI Page of

High threshold: Default threshold off. Display shows OFF Press down enable overrange. Display shows OL Press down show 999 Press button once for each digit of change (down to reduce value, up to increase value) Low threshold: Default threshold off. Display shows OFF Press up button once to enable underrange. Display shows UL Press up show -999 Press button once for each digit of change (down to reduce value, up to increase value) When the DIP switches are returned to the on positions the display shows the current loop value, as defined by the offset and span settings previously programmed. In standard operation, the high and low thresholds have a hysteresis value of two counts. This only applies when going from an alarm condition to a non-alarm condition (i.e. the signal has to go at least counts into the non-alarm condition before the backlight will return to green). This is to prevent flickering and unnecessary repeat alarms. DECIMAL PLACE AND LEADING ZERO SELECTION The position of the decimal point and number of leadings zeros is changed by setting DIP switch to the on position and using the up and down buttons on the rear of the module. The decimal point has three possible positions as well as an off option. The leading zeros can be set to one (the user can select the decimal point position and the leading zero will move accordingly) or all on. Return DIP switch to the on position before installing the module in the application. INVERT ALARMS The red and green backlighting and three alarm outputs can be inverted by moving DIP switch 6 to the on position. INVERT OUTPUTS Changing DIP switch 7 to on inverts the three alarms outputs. i.e. the output that was previously on is now off, and the two outputs that were previously off are now on. This can be used in conjuction with DIP switch 6 to set the outputs back to the original position. SELECT BACKLIGHT SUPPLY V+ and LP+ share a common ground (). By default, V+ and LP+ are not connected. Moving DIP switch 8 to the on position connects LP+ directly to V+, removing the need for a separate supply. FLASHING BACKLIGHT By default, the backlight will flash red when an alarm threshold is exceeded. Temporarily connecting the SW+ and SW- inputs will stop the flashing (the backlight will remain red however). The backlight will not flash again, until the alarm has cleared (i.e. returned to green) and another threshold is exceeded. Connecting a wire link permanently between SW+ and SW- will disabled flashing and the backlight will remain as a solid colour. Specifications liable to change without prior warning Issue /0 S.L Applies to DPM 94-FPSI Page 4 of

FACTORY RESET Module calibration can be reset to the factory default by moving all 8 dip switches to on and powering up the unit. The LCD will display 4 dashes when the reset is complete. Moving all the dip switches back to the off position will return the module to the operating mode. SAFETY To comply with the Low Voltage Directive (LVD 9/68/EEC), input voltages to the module s pins must not exceed 60V d.c. If voltages to the measuring inputs do exceed 60V d.c., then fit scaling resistors externally to the module. The user must ensure that the incorporation of the DPM into the user s equipment conforms to the relevant sections of BS EN 600 (Safety Requirements for Electrical Equipment for Measuring, Control and Laboratory Use). VARIOUS OPERATION MODES 4 4 4-0mA Transmitter I+ I+ LP+ 4-0mA Transmitter I+ I+ LP+ ALM HI SW+ 6 9 R SW- 0 Measuring a current loop. The meter power supply should be isolated from the 4-0mA transmitter power supply Using an external LED as a high alarm and a switch to acknowledge the alarm (to stop it flashing) Module House Whiteparish, Salisbury Wiltshire. SP SJ UK T +44 (794) 88467 F +44 (794) 88466 E sales@lascar.co.uk 4. West th Street Erie PA 60 USA T + (84) 8 06 F + (84) 88 84 E us-sales@lascarelectronics.com 8th Floor, China Aerospace Centre 4 Hoi Bun Road Kwun Tong, Kowloon HONG KONG T +8 89 60 F +8 89 6 E saleshk@lascar.com.hk Specifications liable to change without prior warning Issue 4 0/ N.J.H Applies to DPM 94-FPSI Page of