LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Similar documents
LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

GV2ME. Main. Device short name. Device application

GV2P05. Main. Device short name. Device application

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

GV2ME. Main. Device short name. Device application

A V 50Hz / V 60Hz

AS09..S 3-pole Contactors - Spring Terminals

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

TeSys contactors LC1-D09pp (5) LC1-D12pp (5) 0.325

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Datasheet - SRB301LC 24VAC/DC

Magnecraft Power Relays

Series CT7N Bimetallic Overload Relays

Type: DILM25 10(24V50HZ) Article No.:

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Type: DILM12 10(24VDC) Article No.:

Ordering details. Approval. Classification

Minicontactorrelay,2NO/2NC,DCoperated

Safety dialogue solutions

Datasheet - SRB-E-201ST

02/11/2015

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

16 A and 25 A power contactors with or without handle

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

AC1036. Definite Purpose Contactors

Modular pulse operated latching relay 16 A

Bulletin 190 IEC Modular Starter System

Circuit-Breakers for Motor Protection Series 8523/8

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Data Sheet Definite Purpose Contactors Ex9CK Series

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

ALLEN BRADLEY TIMING RELAY

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Kuhnke Technical Data. Contact Details

Panel-mounting thermostats, type series EM

Interface Relays and Optocouplers Product group picture

Series CDP2 Definite Purpose Contactors

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Series CDP2 Definite Purpose Contactors

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Manual Motor Starter Specifcations

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

Pluggable interface relays CR-M Miniature relays

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

llen-bradley 194R-HM4-NFPA3

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

TeSys circuit-breakers

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

Bulletin 100-G IEC Contactors

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

LED control gear Compact fixed output

Data Pattern Generator

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Definite Purpose Contactors

Generator protection relay

Panel-Mounted Thermostat

TRISHALA ELECTROLYTICS PVT LTD BANGALORE

Bulletin 100-G IEC Contactors

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

Magnetic and Hydraulic-Magnetic Circuit Breaker

Transcription:

Product data sheet Characteristics LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 115 V AC 50/60 Hz coil Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 246.00 USD Main Range Product name Product or component type Device short name Contactor application Utilisation category Poles description Pole contact composition System Voltage [Ie] rated operational current Motor power kw Motor power hp Control circuit type [Uc] control circuit voltage Auxiliary contact composition Nov 18, 2018 TeSys TeSys D Contactor LC1D Motor control Resistive load AC-1 AC-3 AC-4 3P 3 NO <= 300 V DC power circuit <= 690 V AC 25...400 Hz power circuit 50 A (<= 140 F (60 C)) at <= 440 V AC AC-3 power circuit 80 A (<= 140 F (60 C)) at <= 440 V AC AC-1 power circuit 22 kw at 380...400 V AC 50/60 Hz AC-3 25 kw at 415 V AC 50/60 Hz AC-3 30 kw at 440 V AC 50/60 Hz AC-3 30 kw at 500 V AC 50/60 Hz AC-3 33 kw at 660...690 V AC 50/60 Hz AC-3 15 kw at 220...230 V AC 50/60 Hz AC-3 11 kw at 400 V AC 50/60 Hz AC-4 3 hp at 115 V AC 50/60 Hz 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz 1 phase motors 15 hp at 200/208 V AC 50/60 Hz 3 phases motors 15 hp at 230/240 V AC 50/60 Hz 3 phases motors 40 hp at 460/480 V AC 50/60 Hz 3 phases motors 40 hp at 575/600 V AC 50/60 Hz 3 phases motors AC 50/60 Hz 115 V AC 50/60 Hz 1 NO + 1 NC 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

[Uimp] rated impulse withstand voltage Conforming to IEC 60947 Overvoltage category [Ith] conventional free air thermal current III 80 A at <= 140 F (60 C) power circuit 10 A at <= 140 F (60 C) signalling circuit Irms rated making capacity 900 A at 440 V power circuit conforming to IEC 60947 140 A AC signalling circuit conforming to IEC 60947-5-1 250 A DC signalling circuit conforming to IEC 60947-5-1 Rated breaking capacity 900 A at 440 V power circuit conforming to IEC 60947 [Icw] rated short-time withstand current Associated fuse rating Average impedance [Ui] rated insulation voltage Electrical durability Power dissipation per pole Protective cover Mounting support 100 A 1 s signalling circuit 120 A 500 ms signalling circuit 140 A 100 ms signalling circuit 400 A <= 104 F (40 C) 10 s power circuit 810 A <= 104 F (40 C) 1 s power circuit 84 A <= 104 F (40 C) 10 min power circuit 208 A <= 104 F (40 C) 1 min power circuit 100 A gg at <= 690 V coordination type 1 power circuit 100 A gg at <= 690 V coordination type 2 power circuit 10 A gg signalling circuit conforming to IEC 60947-5-1 1.5 mohm at 50 Hz - Ith 80 A power circuit 600 V power circuit certifications CSA 600 V power circuit certifications UL 690 V power circuit conforming to IEC 60947-4-1 690 V signalling circuit conforming to IEC 60947-1 600 V signalling circuit certifications CSA 600 V signalling circuit certifications UL 1.45 Mcycles 50 A AC-3 at Ue <= 440 V 1.1 Mcycles 80 A AC-1 at Ue <= 440 V 3.7 W AC-3 9.6 W AC-1 With Plate Rail Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 Product certifications Connections - terminals Tightening torque BV CCC CSA DNV GL GOST LROS (Lloyds register of shipping) RINA UL Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable end Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - Power circuit : screw connection 2 cable(s) 1...25 mm² - cable stiffness: flexible - with cable end Power circuit : screw connection 2 cable(s) 1...25 mm² - cable stiffness: solid - Power circuit : screw connection 2 cable(s) 1...25 mm² - cable stiffness: flexible - Power circuit : screw connection 1 cable(s) 1...35 mm² - cable stiffness: solid - Power circuit : screw connection 1 cable(s) 1...35 mm² - cable stiffness: flexible - Power circuit : screw connection 1 cable(s) 1...35 mm² - cable stiffness: flexible - with cable end Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 70.8 lbf.in (8 N.m) - on EverLink BTR screw connectors - cable 0.04...0.05 in² (25...35 mm²) hexagonal 0.16 in (4 mm) 2

Operating time Power circuit : 5 N.m - on EverLink BTR screw connectors - cable 1...25 mm² hexagonal 4 mm 12...26 ms closing 4...19 ms opening Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Mechanical durability Operating rate 6 Mcycles 3600 cyc/h at <= 140 F (60 C) Complementary Coil technology Control circuit voltage limits Inrush power in VA Hold-in power consumption in VA Heat dissipation Without built-in suppressor module 0.3...0.6 Uc drop-out at 140 F (60 C), AC 50/60 Hz 0.8...1.1 Uc operational at 140 F (60 C), AC 50 Hz 0.85...1.1 Uc operational at 140 F (60 C), AC 60 Hz 140 VA at 68 F (20 C) (cos ϕ 0.75) 60 Hz 160 VA at 68 F (20 C) (cos ϕ 0.75) 50 Hz 13 VA at 68 F (20 C) (cos ϕ 0.3) 60 Hz 15 VA at 68 F (20 C) (cos ϕ 0.3) 50 Hz 4...5 W at 50/60 Hz Auxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1 Type mirror contact (1 NC) conforming to IEC 60947-4-1 Signalling circuit frequency Minimum switching current Minimum switching voltage Non-overlap time Insulation resistance 25...400 Hz 5 ma signalling circuit 17 V signalling circuit 1.5 ms on de-energisation (between NC and NO contact) 1.5 ms on energisation (between NC and NO contact) > 10 MOhm signalling circuit Environment IP degree of protection IP20 front face conforming to IEC 60529 Protective treatment TH conforming to IEC 60068-2-30 Pollution degree 3 Ambient air temperature for operation Ambient air temperature for storage Permissible ambient air temperature around the device Operating altitude 23...140 F (-5...60 C) -76...176 F (-60...80 C) -40...158 F (-40...70 C) at Uc 9842.52 ft (3000 m) without derating in temperature Fire resistance 1562 F (850 C) conforming to IEC 60695-2-1 Flame retardance V1 conforming to UL 94 Mechanical robustness Height Width Depth Product weight Vibrations contactor open 2 Gn, 5...300 Hz Vibrations contactor closed 4 Gn, 5...300 Hz Shocks contactor open 10 Gn for 11 ms Shocks contactor closed 15 Gn for 11 ms 4.8 in (122 mm) 2.17 in (55 mm) 4.72 in (120 mm) 1.88 lb(us) (0.855 kg) Ordering and shipping details Category 22345 - CTR,D-LINE,OPEN,NONREV-NEW Discount Schedule I12 GTIN 003389119408660 Nbr. of units in pkg. 1 Package weight(lbs) 2.0699999999999998 Returnability N Country of origin FR 3

Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Green Premium product Compliant - since 0001 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Product environmental profile Available Product end of life instructions Available California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. - - - - - - - More information For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months 4

Product data sheet Dimensions Drawings LC1D50AFE7 Dimensions (1) Minimum electrical clearance LC1 D40A D65A a 55 b1 with LA4 D 2 with LA4 DB3 or LAD 4BB3 with LA4 DF, DT with LA4 DM, DW, DL 136 157 166 c without cover or add-on blocks 118 with cover, without add-on blocks 120 c1 with LAD N (1 contact) with LAD N or C (2 or 4 contacts) 150 c2 with LA6 DK10, LAD 6DK 163 c3 with LAD T, R, S 171 with LAD T, R, S and sealing cover 175 5

Product data sheet Connections and Schema LC1D50AFE7 Wiring 6