Using different reference quantities in ArtemiS SUITE

Similar documents
Pre-processing of revolution speed data in ArtemiS SUITE 1

Torsional vibration analysis in ArtemiS SUITE 1

Channel calculation with a Calculation Project

Next Generation Software Solution for Sound Engineering

Using the BHM binaural head microphone

Loudness and Sharpness Calculation

E X P E R I M E N T 1

Footnotes and Endnotes

HEAD. HEAD VISOR (Code 7500ff) Overview. Features. System for online localization of sound sources in real time

Cisco Spectrum Expert Software Overview

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

EDL8 Race Dash Manual Engine Management Systems

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

Reference Management using EndNote

EndNote X7: the basics (downloadable desktop version)

Quick-Start for READ30

Exercise #1: Create and Revise a Smart Group

EndNote Web. Quick Reference Card THOMSON SCIENTIFIC

(Skip to step 11 if you are already familiar with connecting to the Tribot)

D-Lab & D-Lab Control Plan. Measure. Analyse. User Manual

INTRODUCTION TO ENDNOTE

EndNote X6 Workshop Michigan State University Libraries

SIDRA INTERSECTION 8.0 UPDATE HISTORY

Field Test 2. Installation and operation manual OPDAQ Installation and operation manual

EndNote Tutorial Handout Table of Contents

Virtual instruments and introduction to LabView

Instructions for DataMark PDF Temperature Logger

Introduction to EndNote Desktop

With Export all setting information (preferences, user setttings) can be exported into a text file.

Data Acquisition Using LabVIEW

A-ATF (1) PictureGear Pocket. Operating Instructions Version 2.0

Quick Reference Manual

PS User Guide Series Seismic-Data Display

Training. Center Training Courses

EndNote Workshop. King Abdulaziz University. Center for Teaching & Learning Development. Done by: Jamilah Al-Amri

Session 1 Introduction to Data Acquisition and Real-Time Control

Source/Receiver (SR) Setup

Basic LabVIEW Programming Amit J Nimunkar, Sara Karle, Michele Lorenz, Emily Maslonkowski

HCS-4100/20 Series Application Software

Obtain Power Measurements of a DOCSIS Downstream Signal Using a Spectrum Analyzer

Binaural Measurement, Analysis and Playback

Fig. 1. The Front Panel (Graphical User Interface)

Common Spatial Patterns 3 class BCI V Copyright 2012 g.tec medical engineering GmbH

Introduction to EndNote Online

Chapter 5 Printing with Calc

Kindle Add-In for Microsoft Word User Guide

VIDEOPOINT CAPTURE 2.1

Defining and Labeling Circuits and Electrical Phasing in PLS-CADD

INTRODUCTION TO ENDNOTE. NTNU University Library, Medicine and Health Library January 2017

Getting Started with the LabVIEW Sound and Vibration Toolkit

READ THIS FIRST. Morphologi G3. Quick Start Guide. MAN0412 Issue1.1

Analyzing Modulated Signals with the V93000 Signal Analyzer Tool. Joe Kelly, Verigy, Inc.

Spectrum Analyser Basics

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ

Introduction To LabVIEW and the DSP Board

The. finale. Projects. The New Approach to Learning. finale. Tom Carruth

Using the new psychoacoustic tonality analyses Tonality (Hearing Model) 1

Transmitter Interface Program

EndNote X7: the basics (downloadable desktop version)

OPTIMUM Power Technology: Low Cost Combustion Analysis for University Engine Design Programs Using ICEview and NI Compact DAQ Chassis

Capstone Experiment Setups & Procedures PHYS 1111L/2211L

Contents DIVISION OF LIBRARY SERVICES. EndNote X7 Mac User Manual Part 2

Experiment 13 Sampling and reconstruction

Analyzing and Saving a Signal

Tutorial FITMASTER Tutorial

Desktop. Basic use of EndNote. Important start info 3 tips p. 1. Entering references manually p. 3

AmbDec User Manual. Fons Adriaensen

RefWorks Using Write-N-Cite

Table of Contents. 2 Select camera-lens configuration Select camera and lens type Listbox: Select source image... 8

MXS Strada USER GUIDE

PicoScope 6 Training Manual

SNR Playback Viewer SNR Version 1.9.7

Mendeley Basics. Get Mendeley. Get Articles and Documents into Mendeley. Import Citations from a Website

Colour Features in Adobe Creative Suite

Supplement to the Operating Instructions. PRemote V 1.2.x. Dallmeier electronic GmbH. DK GB / Rev /

Using RefWorks Write-N-Cite for Mac v.2.5

MestReNova Manual for Chem 201/202. October, 2015.

Application Note 11 - Totalization

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

ConeXus User Guide. HHAeXchange s Communication Functionality

EYE TRACKING DATA ANALYSIS TOOL

Universal Mode. Survey Settings. The Universal Toolbar. First Run - Initial Configuration via the Setup Button

DSP Laboratory: Analog to Digital and Digital to Analog Conversion *

VivoSense. User Manual Galvanic Skin Response (GSR) Analysis Module. VivoSense, Inc. Newport Beach, CA, USA Tel. (858) , Fax.

GET STARTED WITH ACADEMIC WRITER

What s New in Raven May 2006 This document briefly summarizes the new features that have been added to Raven since the release of Raven

Linrad On-Screen Controls K1JT

What is Endnote? A bibliographical management software package designed to : Organize bibliographic references Create a bibliography

PSC300 Operation Manual

FSK Transmitter/Receiver Simulation Using AWR VSS

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

DT9857E. Key Features: Dynamic Signal Analyzer for Sound and Vibration Analysis Expandable to 64 Channels

D-901 PC SOFTWARE Version 3

MICROSOFT WORD FEATURES FOR ARTS POSTGRADUATES

Dewesoft Instructions: Chapter Needed files. Contents:

Eventide Inc. One Alsan Way Little Ferry, NJ

LabView Exercises: Part II

USB Mini Spectrum Analyzer User s Guide TSA5G35

A Matlab toolbox for. Characterisation Of Recorded Underwater Sound (CHORUS) USER S GUIDE

WindData Explorer User Manual

Transcription:

06/17 in ArtemiS SUITE ArtemiS SUITE allows you to perform sound analyses versus a number of different reference quantities. Many analyses are calculated and displayed versus time, such as Level vs. Time, FFT vs. Time, etc. For other application cases, however, it can be important to evaluate the changes of a signal depending on other quantities. Most commonly used besides the calculation versus time are analyses versus revolution speed (revolutions per minute, rpm). However, ArtemiS SUITE also allows you to calculate an analysis referenced to any other quantity. For example, you can visualize the dependency of a signal level on a force. The data you can use as a reference quantity in ArtemiS SUITE can be stored in the file in a number of ways. For example, the information representing the reference quantity can be in the form of pulses in a digital or analog channel. ArtemiS SUITE can then calculate a revolution speed curve from this pulse signal. On the other hand, any analog channel of a file can be chosen directly as the reference quantity. If the reference quantity is stored in the form of pulses, it may be necessary to decode the pulse signal first. Comprehensive information on this can be found in the Pre-processing of revolution speed data in ArtemiS SUITE. This 1 covers the following subjects: Analysis versus a reference quantity 1 Selecting the reference quantity for the result display 2 Pool project 2 Automation project and Standardized Test Project 2 Compact Analysis Project 2 for the order calculation and the result display 3 Converting pulse signals into an analog channel 5 Analysis versus a reference quantity ArtemiS SUITE provides a wide range of analysis functions. Analyses calculated and displayed as a function of time can be recognized by vs. Time in their names. Analyses named vs. RPM are displayed as a function of whatever reference quantity is specified in the Properties window of the mark. This can be a revolution speed channel (as suggested by RPM ), but it can also be any other quantity you recorded along with your signal. Thus using the analysis Level vs. RPM not only allows to display the rpm-depending level curve, but also, e.g., a pressure-depending level curve, if a corresponding channel is available. In the Properties window of these analyses, you can configure the step size for the calculation points. Depending on your reference quantity, this value then does not refer to RPM, but, for example, to a force. The step size should have a reasonable proportion to the relevant value range of the reference quantity. The default step size of 50 in the properties for analyses vs. RPM, expecting rotational speed, is often too large a value for other reference quantities and if not recognized and changed, can lead to mysteriously uninformative results. An appropriate step size for an analysis versus revolution speed with a value range from 1000 to 6000 rpm can be considerably higher than the appropriate step size for an analysis against force with a range from 300 to 800 Newton, or speed with a span of 50 to 200 km/h. 1 The descriptions in this refer to version 8.3 of ArtemiS SUITE. The general proceeding also applies to other versions. However, the scope of functions and the user interface may differ. 1

Selecting the reference quantity for the result display Pool project The reference quantity for displaying analysis results is selected via the Source Pool of the Pool Project, in the Properties dialog of an individual mark 2 or a folder. Moreover, after a multiple selection you can edit the reference quantity for all selected marks at once. Figure 1 shows the relevant section of such a Properties window. Figure 1: Properties window for selecting the Reference quantity After clicking on the arrow in the select box Reference quantity you can select a channel from the file s channel list as the reference quantity. In figure 1 the engine speed was selected, which is stored in the 13 th signal channel in the present example. Reference quantities recorded as pulse signals are labeled with (pulse channel) or (trigger channel) in addition to the unit icon. The differences between these two data formats as well as the required pre-processing steps are described in the Pre-processing of revolution speed data in ArtemiS SUITE. Automation Project and Standardized Test Project In an Automation Project or a Standardized Test Project, you can specify the reference quantity for displaying analysis results via the processes Mark by time and Mark by rpm. To do so, go to the Properties window of the respective process and specify in the select box Reference Channel whether it is a pulse signal in a Pulse Channel or a Signal Channel, i.e., a reference quantity in an analog channel. Then specify the channel either via the channel name or by entering the channel number. The latter always refers to the selected channel type, which means that 1 either selects the first signal channel or the first pulse channel. Figure 2 shows the relevant section of such a Properties window. Figure 2: Properties window for selecting the reference quantity for the process Mark by time Compact Analysis Project When using a Compact Analysis Project for your analyses, the desired reference variable can be selected after having clicked the button. After clicking, you will see all input data currently being available in the Compact Analysis Project. Please click on the arrow icon next to the checkbox Control Channel and select the desired channel as reference quantity from the channel list. 2 The Source Pool works with marks, which are pointers (references) to the actual time domain signal files. For example, if you perform an analysis or filtering, the original time domain signal data are not modified. 2

Figure 3: Compact Analysis Project with Control Channel selection for the order calculation and the result display Using a Pool Project, an Automation Project or a Standardized Test Project ArtemiS SUITE allows you to perform an order calculation against revolution speed and to display the analysis results against a different reference quantity. In order to perform such a calculation in a Pool Project, the quantity for the order calculation must be specified in the Properties window of the mark in the Order calculation field. For this field, only channels containing revolution speed information can be used. The quantity specified in the Reference quantity field, on the other hand, is used for displaying the analysis results. As described above, here you can select any of the channels contained in your mark. Figures 4 and 5 show for example two order spectra displayed with different reference quantities. In the upper diagram, the orders have been determined based on the revolution speed of an engine (Engine speed) and are displayed versus this revolution speed. In the lower diagram, the analysis has also been calculated based on the engine speed, but is now displayed versus the Drive shaft speed. With an Automation Project or a Standardized Test Project, the channel for the order calculation can be specified via the processes Mark by time or Mark by rpm respectively. For this purpose please use the field Order Channel in the Properties window of these processes to select the signal type first and the channel name or channel number afterwards. As with the Pool Project, the channel for the order calculation may differ from the channel for the reference quantity. In order to calculate the order spectrum correctly, a channel with an rpm signal has to be selected for the order calculation here, too. 3

Figure 4: Order analysis calculated and displayed versus engine speed Figure 5: Order analysis calculated against engine speed and displayed versus vehicle speed 4

Converting pulse signals into an analog channel Reference quantities that are to be examined with statistical operations in ArtemiS SUITE, e.g., in order to determine the difference between the left and the right wheel revolution speed, must be stored in analog channels. A reference quantity stored as a pulse signal must therefore first be converted into an analog channel. This applies to pulse signals stored in digital pulse channels as well as to pulse signals in an analog channel (trigger channel). To convert a pulse signal into an analog channel, use a Decoder Project with a pulse decoder. To open a new Decoder Project 3, click on Start New Decoder Project. A decoder project has three pools similar to those of a normal Pool Project (see figure 6). Figure 6: Decoder Project Use the Source Pool on the left to insert the time domain signal(s) containing a pulse signal you want to convert into an analog channel. In the center pool, similar to the Analysis Pool of a normal Pool Project, insert a decoder. ArtemiS SUITE uses the decoder to calculate an additional analog channel containing the decoded revolution speed information. Depending on whether you want to convert a pulse channel or a trigger channel click on Insert Decoder -> Pulse or Trigger in the context menu of the center pool. In the preview window of the Decoder Project displayed below the pools (see figure 6), you can inspect the calculated revolution speed curve in advance. In the right pool of the Decoder Project, you can specify the format for the new file. After opening a new Decoder Project the HDF format is activated by default. You can use this format if you want to further analyze the file in ArtemiS SUITE, because the file can be inserted directly e.g. into a Pool Project. For analyzing the file with other software applications a file export to ATFX and UFF format is available 4. Exporting the file to a third-party format is useful if you want to further process the data with software applications that cannot interpret pulse information. The procedure described above converts the pulse information to a form that can be evaluated by third-party software products. 3 A Decoder Project can only be opened if your ArtemiS SUITE license includes the Data Preparation Module (ASM 24). 4 UFF export can only be used if your ArtemiS SUITE license includes the Advanced Import & Export Module (ASM 23). 5

In a Decoder Project, all input signals are always active, allowing you to apply the conversion of revolution speed data to multiple files at once. Clicking on the abacus icon starts the conversion. Afterwards, you can insert the newly created files, e.g, into a Pool Project for further analysis. A particularly convenient way to do this is by using the Recent Results list of the HEAD Navigator. The results calculated most recently can be found at the top of this list, and can simply be dragged and dropped to the required place. Do you have questions or suggestions? Please do not hesitate to contact us at imke.hauswirth@head-acoustics.de. We look forward to your feedback! 6