Application Note - TechComplete Test Productivity Pack. POP Reporting

Similar documents
StrataSync. DSAM 24 Hour POP Report

Q-Lab Software. for the 8821Q-R OPERATION MANUAL

SAWM60 AUDIO/VIDEO MODULATOR

HMA-860H AGILE MODULATOR

FCC Required Technical Standards for Analog & Digital Signals

TROUBLESHOOTING DIGITALLY MODULATED SIGNALS, PART 2 By RON HRANAC

Review of the Comcast. Fort Collins Cable System. Technical Characteristics

Eagle Business Software

ConeXus Process Guide

EndNote Essentials. EndNote Overview PC. KUMC Dykes Library

Table of Contents. iii

Analyzing and Saving a Signal

innovative technology to keep you a step ahead Tailored to Simplify Installation and Troubleshooting of RF Signals

Printed Documentation

innovative technology to keep you a step ahead Tailored to Simplify Installation and Troubleshooting of RF Signals

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

Model Three Signal Level Meter. Operation Manual

USER S MANUAL REV 1.0 FORM# 7677

Positive Attendance. Overview What is Positive Attendance? Who may use Positive Attendance? How does the Positive Attendance option work?

Projector Management Application Version 7.00 Instruction Guide

CA Outbound Dialer Module. Operation Manual v1.1

ADVANCED SYSTEM DESIGN PRODUCT SPECIFICATIONS

***Please be aware that there are some issues of compatibility between all current versions of EndNote and macos Sierra (version 10.12).

ANSI/SCTE 40 Conformance Testing Using the R&S SFU, R&S SFE and R&S SFE100

Model Two and Model Two Lite Signal Level Meters OPERATION MANUAL

Keysight Method of Implementation (MOI) for VESA DisplayPort (DP) Standard Version 1.3 Cable-Connector Compliance Tests Using E5071C ENA Option TDR

TF5 / TF3 / TF1 DIGITAL MIXING CONSOLE. TF Editor User Guide

860 DSPi. Multifunction HFC Analyzer. Enhanced Sweep and RSVP Features. DSP Technology Provides Quick, Accurate Measurements

HyperMedia User Manual

860 DSP Digital Field Analyzer

TSG 90 PATHFINDER NTSC Signal Generator

RedRat Control User Guide

My XDS Receiver- Affiliate Scheduler

Skycoor Manual PEKASAT SE 2016

CATV & DOCSIS3.0 Meter / Analyzer. Purchase from:

innovative technology to keep you a step ahead 24/7 Monitoring Detects Problems Early by Automatically Scanning Levels and other Key Parameters

HD-CM HORIZON DIGITAL CABLE METER

Updates to the Form and Filing System

MIGRATION TO FULL DIGITAL CHANNEL LOADING ON A CABLE SYSTEM. Marc Ryba Motorola Broadband Communications Sector

Introduction to EndNote Desktop

FORWARD PATH TRANSMITTERS

D-901 PC SOFTWARE Version 3

Getting Started with the LabVIEW Sound and Vibration Toolkit

Synergy SIS Attendance Administrator Guide

Remote Application Update for the RCM33xx

INTRODUCTION TO ENDNOTE

DIGITAL MIXING CONSOLE. TF Editor V3.6 User's Guide

MAutoPitch. Presets button. Left arrow button. Right arrow button. Randomize button. Save button. Panic button. Settings button

SNG-2150C User s Guide

Table of Contents. Amplifiers Broadband Telecommunications Line Extender [BLE-75**] FEATURES

Getting started with

DS2460Q QAM Analysis Meter

EndNote for Windows. Take a class. Background. Getting Started. 1 of 17

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ

Installation and Users Guide Addendum. Software Mixer Reference and Application. Macintosh OSX Version

Dragon. manual version 1.6

OTM-3550-SW FREQUENCY AGILE F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL

TRAINING DOCUMENT LOS ANGELES UNIFIED SCHOOL DISTRICT (LAUSD) BELL SCHEDULING SYSTEM

Operating Instructions

Challenges of Launching DOCSIS 3.0 services. (Choice s experience) Installation and configuration

Amplifiers STARLINE 2000 Broadband Telecommunications Distribution Amplifier [BT*/*]

Transmitter Interface Program

OMNISTAR GX2. GX2-LM1000E Series 1310 nm Broadcast Transmitter DATA SHEET BENEFITS. 1 GHz bandwidth

Introduction to EndNote Online

CAM Series Channelized Agile Audio/Video Modulators

UltraPioneerAVR3 HSPI User s Guide A HomeSeer HS3 plug-in to enable control of Pioneer A/V Receivers that support the IP & RS232 control system.

Interface Practices Subcommittee SCTE STANDARD SCTE Composite Distortion Measurements (CSO & CTB)

DIGITAL MEASURES BIBTEX AND PUBMED IMPORT- MANUAL

OTM FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL

Surge-Gap Drop Amplifier 1 GHz with 42/54 MHz Split

IP LIVE PRODUCTION UNIT NXL-IP55 USO RESTRITO. OPERATION MANUAL 1st Edition (Revised 2) [English]

Defining and Labeling Circuits and Electrical Phasing in PLS-CADD

ENGINEERING COMMITTEE

Viewing Set-Top Box Data

0.56" 4 Digital Blue LED Panel Meter (rescalable) User s Guide

Agilent MOI for HDMI 1.4b Cable Assembly Test Revision Jul 2012

Autotask Integration Guide

CI-218 / CI-303 / CI430

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com OPERATION MANUAL. The Best Thing on Cable

DQT1000 MODEL DIGITAL TO QAM TRANSCODER WITH DIGITAL PROCESSING AND MULTIPLEXING

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

SA 1454 Signal Analyzer

IP LIVE PRODUCTION UNIT NXL-IP55

Getting started with

Test Procedure for Common Path Distortion (CPD)

Synthesized Block Up- and Downconverter

QRF5000 MDU ENCODER. Data Sheet

rekordbox TM LIGHTING mode Operation Guide

Rack-Mount Receiver Analyzer 101

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

Model GS Port Node 1 GHz with 65/86 MHz split

EndNote X6 Workshop Michigan State University Libraries

FSK Transmitter/Receiver Simulation Using AWR VSS

administration access control A security feature that determines who can edit the configuration settings for a given Transmitter.

JDSU DSAM-2000 XT Specs Provided by DSAM Digital Services Analysis Meter

ViewCommander- NVR Version 3. User s Guide

Cisco Spectrum Expert Software Overview

USB Mini Spectrum Analyzer User s Guide TSA5G35

USER GUIDE. Get the most out of your DTC TV service!

ExtIO Plugin User Guide

Transcription:

Application Note - TechComplete Test Productivity Pack Page 1 of 61

Table of Contents Introduction... 5 POP Test Configuration... 6 Executing POP Tests on DSAM... 7 Accessing POP Reports... 9 POP Reports Settings... 10 1. POP Limits Section... 10 a) Editable POP Limits Non Licensed Version... 10 b) Editable POP Limits Licensed Version... 11 2. System Information Section... 13 3. Reports Configuration Licensed Version... 13 a) Signal Quality Units... 13 b) Display Audio Level or Video Audio Delta Level... 13 c) Change Six Month Deviation Formula... 14 d) POP Reports Required and Matching Fields... 14 How to Create 24 Hour POP Reports... 15 1. Search for test files... 15 2. Configure data for 24 hour POP reports Non Licensed Version... 18 3. Configure data for 24 hour POP reports Licensed Version... 18 4. CSV Export... 22 5. CSV Import... 23 a) Disable Import of System Information/Measurement File Data from CSV File... 24 b) Steps to Import CSV File... 24 6. Delete Channels... 26 7. View 24 hour POP report... 26 a) Non Licensed Version... 27 b) Licensed Version... 29 8. Save 24 hour POP Report Licensed Version... 32 24 Hour POP Report Features Licensed Version... 32 1. Search 24 hour POP Report... 32 2. View 24 hour POP report... 34 3. Regenerate 24 hour POP report... 34 Page 2 of 61

4. View measurement files used in 24 hour POP report... 35 5. Upload attachments... 36 6. Download attachments... 36 7. Delete attachments... 36 8. Save report as HTML or XLS... 37 9. Export Familyware files... 37 10. Export Report bundle... 37 11. Import 24 hour POP report... 37 12. Delete 24 hour POP report... 39 How to Create System Summary Report Licensed Version... 39 How to Create Six Month Report Licensed Version... 42 1. Search for 24 hour POP reports... 42 2. Ignore Channel Frequency and Type Errors during 6 Month Deviation Calculation... 47 6 Month POP Report Features Licensed Version... 48 1. Search 6 month Report... 48 2. View 6 month report... 49 3. View 6 month Summary report... 49 4. View 24 hour reports... 51 5. Upload attachments... 51 6. Download attachments... 51 7. Delete attachments... 51 8. Save report as HTML or XLS... 52 9. Export Report bundle... 52 10. Import 6 month POP report... 52 11. Delete 6 month POP report... 54 APPENDIX A. TPP Test Reporting System POP Report Details... 55 When Report Name is considered unique?... 55 When does a 24 hour POP report fails?... 55 Conditions to generate a 6 month POP report Licensed Version... 57 When does a 6 month POP report fail? Licensed Version... 58 Page 3 of 61

Configuring the POP Report... 58 POP Default Limits... 58 APPENDIX B. Summary of FCC Proof of Performance Test... 60 Overview of FCC Proof of Performance Test Requirements... 60 Who must run the tests?... 60 When do the tests need to be run?... 60 How many channels need to be tested?... 60 How are the test channels selected?... 60 How many test sites do we need?... 60 Where, in the system, are the tests conducted?... 61 Are there specified procedures for each test?... 61 Where do we send the test results?... 61 What happens if we don't pass?... 61 Where do I go for more information on Proof Testing?... 61 Page 4 of 61

Introduction The term Proof of Performance tests may have different interpretations depending on your geographic locality. In North America, Proof of Performance tests can tie directly to testing mandated by the Federal Communications Commission (FCC); however, in other localities Proof of Performance test may simply refer to having the ability to run test over various times and physical constraints such as weather and/or temperature. The DSAM meter can perform Proof of Performance tests immediately or over any set of time intervals that you desire. This is particularly useful when you are running the 24- Hour test required by the FCC in the US and by other international governing bodies. With release of TPP v4.6, following are enhancements to POP reports feature: I. Digital measurements are added to 24 hour POP reports. II. Limits present in the DSAM POP measurement files are not used in the TPP POP Reports. POP limits configured in the TPP POP Reports section are used for creating those reports. III. Following tests are added to 24 hour POP reports Adjacent Visual Signal Level Minimum Visual Signal Level Aural Carrier Level Analog Delta Video Digital Delta Video IV. Following are newly added POP tests/features that are available only with the purchase of POP license: Analog Measurement Tests in 24 hour POP report Visual Carrier Frequency Aural Carrier Frequency Offset Carrier to Noise Hum In-Channel Frequency Response Carrier Triple Beat (CTB) Carrier Second Order (CSO) Digital Measurement Tests in 24 hour POP report Visual Carrier Frequency MER Pre-BER Post-BER In-Channel Frequency Response Group Delay Gain Compression EQStress@0.5 EQStress@1.0 EQStress@1.5 EQStress@4.5 6 Month Deviation Test Editing POP FCC limits Page 5 of 61

Searching 24 hour and 6 month POP reports. Configuring data for 24 hour POP report. Deleting channels from 24 hour POP report. Saving 24 hour POP reports Regeneration of 24 hour POP reports. System Summary Report Six month report Six month summary report Exporting POP reports along with attachments and importing them into another TPP Server It is a fact that all cable systems need to be able to consistently check measurements in their network during various times and over a wide temperature range. The DSAM together with the Test Productivity Pack (TPP) provides a seamless way for operators to conduct Proof of Performance. This Application Note will provide key step-by-step instructions on setting up TPP to work in conjunction with the DSAM to deliver the Proof of Performance functionality. POP Test Configuration Proof of Performance testing is configured using TPP. A typical configuration for performing Proof of Performance test is shown below. 1. Select the Location File Icon from the main menu. 2. Create a new Proof Location File by double-clicking on the default Proof of Performance file. Page 6 of 61

3. Customize Proof of Performance initial values and/or Field Names 4. Deploy / Save the location in the same fashion as done for Channel or Limit Plans 5. Synchronize selected meters with the appropriate TPP Server Executing POP Tests on DSAM Key steps in running the Proof of Performance test on the DSAM include the following: 1. Press the AutoTest button on the DSAM 2. Scroll down to and select proof of performance Page 7 of 61

3. Configure the Proof of Performance Test Channel Plan, Limit Plan, Filename to save to, Ambient Temp, etc. Name entered in Filename to save to field will become folder name for the proof of performance files. 4. Configure Proof of Performance Test Scheduling via Scheduled Soft Key Meter shuts down until time of Auto Test and wakes itself Input start time, interval, date, etc... 4 sessions over a 24 hour period 5. Input location data (i.e. Location, Location Type, Area, Trunk, AMP ID ) Page 8 of 61

6. Start Proof of Performance Test 7. Monitor progress and Review Results. 8. Results are saved in an appropriately named folder as entered in Filename to save to field in step3. 9. Sync the DSAM to the TPP Server to transfer test results to the server Accessing POP Reports Links to access POP reports are available from two places: 1) In left panel, under Test Reporting System section as shown below: Page 9 of 61

2) Click on Test Reporting System in left panel. In right panel, under Test Reporting System menu. POP Reports Settings In left panel, click on POP reports link. In right panel, in POP reports page, click on POP REPORTS SETTINGS link. POP reports settings page allows user to set system information mapping, audio level or video audio delta level information to be displayed in 24 hour POP report and edit POP FCC limits that are used in validating POP tests. Click on Save button at the top or bottom of page to save changes to any edited fields. This page has following sections: 1. POP Limits Section This section contains limits that are used in determining the Pass/Fail status for various POP tests. After editing the limit values, click on Save button at the top or bottom of page to save changes. To restore default FCC limits, click on Set Limit Defaults button at the bottom of page followed by click on Save button to save changes. a) Editable POP Limits Non Licensed Version Below are the editable limits for non licensed POP version and TPP applies modified limits while performing 24 hour POP tests. Page 10 of 61

b) Editable POP Limits Licensed Version Below limit values can be changed and TPP applies modified limits while performing 24 hour or 6 month POP tests. Page 11 of 61

Page 12 of 61

2. System Information Section a) Create and Deploy location file to DSAM as explained in section POP Test Configuration. b) Enter location field names from above file that contains System, Test Point, Test Point Location, Headend/Hub and Municipality information respectively. When the above fields are set, TPP automatically pulls Report Name, System, Test Point, Test Point Location, Headend/Hub and Municipality from location information in a measurement file and displays this information in 24 hour POP report. If the above fields are blank then TPP will not display this information in 24 hour POP report. 3. Reports Configuration Licensed Version a) Signal Quality Units This setting is POP-report-specific site-wide configuration for all POP reports data entry and display fields. The data will be presented in selected QAM signal quality unit in POP report configuration page and other reports only upon pressing save button at the end. b) Display Audio Level or Video Audio Delta Level In below drop down, select Audio Level or Video Audio Delta Level, if you like to have Audio Level or Video Audio Delta Level displayed in 24 hour POP report. Page 13 of 61

c) Change Six Month Deviation Formula There are two formulas that are available which determine six month deviation calculation using 8 POP test files. Select an option and click on Save button to save changes. d) POP Reports Required and Matching Fields Configure Required Fields for 24 hour POP Report Creation By default, the required non configurable fields for 24 hour POP report creation are System and Test Point. During 24 hour POP report creation, along with the above fields Test Point Location, Headend/Hub and Municipality are also displayed. This section allows user to configure whether Test Point Location, Page 14 of 61

Headend/Hub and Municipality are required or non-required fields during creation of a 24 hour report. If the above highlighted fields in red are set to true, then TPP will not allow user to create or save 24 hour POP report if any of these fields are left as blank. Configure Matching Fields for 6 Month POP Report Creation For 6 Month POP report creation, by default, the required non configurable matching fields between two selected 24 hour POP reports are System and Test Point. Along with the above fields, TPP allows user to configure whether Test Point Location, Headend/Hub and Municipality required being same across selected 24 hour POP Reports during 6 month POP report creation. If the above highlighted fields in red are set to true, then TPP will not allow user to create a 6 Month POP report if any of these fields that are set to true do not match across selected 24 hour POP reports. How to Create 24 Hour POP Reports 1. Search for test files There are two ways to get list of test files from the database that can be used to generate 24 hour POP Reports: Click on TPP test files link in left panel. Click on show test files link or any other link under Search for test files by section followed by find button press will display list files page. Based on search this page can display all types of measurement files like Video Auto Test, Home Certification, and POP etc. Choose 4 files for your 24 hour POP report and click on 24 icon to generate your report Page 15 of 61

Snapshot of TPP test files page: In left panel, click on POP reports link. Below are the screen shots of POP reports page without license and with license. Snapshot of POP reports page Non Licensed Version Page 16 of 61

Snapshot of POP reports page Licensed Version In POP reports page, select proof of performance tests option and click on find button. This will display POP test files page. Choose 4 files for your 24 hour POP report and click on 24 icon to generate your report. Page 17 of 61

Snapshot of POP test files page: 2. Configure data for 24 hour POP reports Non Licensed Version Snapshot of POP report configuration page Non Licensed Version 3. Configure data for 24 hour POP reports Licensed Version Fill in all the required * fields. Report Name, System, Test Point, Test Point Location, Headend/Hub and Municipality are automatically filled in if System Information is set as explained in POP Reports Settings System Information section. If mapped keys as set in POP reports settings page are Page 18 of 61

not found then the above mentioned fields will be empty and user has to manually fill in information. If Test Point key as set in POP reports settings page is not found in Location File, then TPP will set the value of Test Point field to work folder name in which the first file in Import Data from File drop down is saved. Report Name, System, Test Point, Test Point Location, Headend/Hub and Municipality are always displayed using location file from first measurement file in Import Data from File drop down. Selecting a different file in Import Data from File drop down will not update the system information. Active Analog and Active Digital channels fields are populated from channel plan used. Selecting a file in Import Data from File drop down will update the counts. Bandwidth is calculated using channel plan from first measurement file as shown in import data from file drop down as follows: Bandwidth = (Highest active channel frequency in channel plan Lowest Frequency)-1.25f; Minimum Required Test Channels is a calculated field by applying FCC standards using bandwidth information as explained below: a minimum of four (4) channels plus one additional channel for every 100 MHz, or fraction thereof, of cable distribution system upper frequency limit (e.g. 5 channels for cable system upper frequency limit of 101 to 216 MHz; 6 channels for cable television systems with a cable distribution system upper frequency limit of 217-300 MHz; 7 channels for cable television systems with a cable distribution upper frequency to 300 to 400 MHz, etc.). In measurement file section, you can change the temperature of any file. If temperature field for a file is 0 then TPP will use temperature information from measurement file if available. Converter selection determines the limits that are used during Aural Carrier Level test. For baseband, V/A should be between Minimum Baseband Video/Aural Carrier Level Delta and Maximum Baseband Video/Aural Carrier Level Delta. For none and standard, V/A should be between Minimum Standard Video/Aural Carrier Level Delta and Maximum Standard Video/Aural Carrier Level Delta Value selected in Cable System drop down determines the limit values that are used in performing Carrier Triple Beat (CTB) and Carrier Second Order (CSO). If value selected is Non Coherent then limit value of field Minimum Standard Coherent Disturbance as set in POP reports settings page is used for CTB and CSO test. If value selected is Coherent then limit value of field Minimum Baseband Coherent Disturbance as set in POP reports settings page is used for CTB and CSO test. By default information from first measurement file will be populated into Analog and Digital Channels Table. Changing the value in import data from file will fill the analog channels and digital channels tables with data from the selected measurement file. In Analog Channel Table or Digital Channels Table, if all rows in a column for a test are empty then that test is not performed. Fill in data in columns for each test that needs to be performed. The number of channels with data filled in for each test should be >= count Page 19 of 61

displayed in Minimum Required Test Channels field, otherwise respective test will be failed. To clear data in a column under Analog Channels Table and Digital Channels Table, click on clear button. POP report configuration page screen shot Licensed Version Page 20 of 61

Page 21 of 61

4. CSV Export This feature allows exporting the page data to CSV file in a format supported by TPP for CSV import. Data can be exported to CSV file as explained below: Click on CSV Export button as shown below in red box. If the browser is IE, it will show a File Download dialog as shown below. Click on Save button. Page 22 of 61

Enter file name in the dialog as shown below and click on Save button. All data in page is saved to CSV file. Open file using Microsoft Excel, edit data and import file using CSV Import functionality as explained below. 5. CSV Import The CSV file that contains measurement file data to be imported to TPP should be in the supported template format. This template can be obtained by following steps in CSV Export section. On successful CSV file import, TPP will overwrite data in all fields in page with data from the file. Page 23 of 61

a) Disable Import of System Information/Measurement File Data from CSV File Disabling import of system information from CSV file will not import data for Report Name, System, Test Point, Test Point Location, Headend/Hub, Municipality, Bandwidth, Converter, Cable System and Comments fields. Disabling import of measurement file data from CSV will not import temperature for measurement file. Follow these steps to disable import of system information or temperature for measurement file from CSV file: Stop TPP server by stopping FDM250Service using windows services panel. To disable import of system information from CSV file, add the following property to configuration.properties, often installed at C:\Program Files\Acterna FDM-250\cfg. CSV_IMPORT_POP_SYSTEM_INFO= false To disable import of temperature for measurement file from CSV file, add the following property to configuration.properties, often installed at C:\Program Files\Acterna FDM-250\cfg. CSV_IMPORT_POP_MEASFILE_INFO = false Save changes and start TPP server by starting FDM250Service using windows services panel. b) Steps to Import CSV File Follow these steps to import CSV file to TPP: Click on Browse button as shown in below screen shot: In fie upload dialog, navigate to location of CSV file, select the file and click on Open button as shown in below screen shot: Page 24 of 61

Click on CSV Import button as shown in below screen shot: Click Ok button on the pop up as shown below: Page 25 of 61

If there are any errors displayed at the top of the page, repeat all the above steps after fixing CSV file. If you do not see any error messages at the top, verify all the data in page and click on View Report or Save Report button to view or save report. 6. Delete Channels To delete Analog and Digital channels from 24 hour POP report, select delete check box against the required channel number and click on Delete Channels button at the bottom of page. Click on View Report or Save Report button to view or save report. Once the channels are deleted and report is saved then deleted channels will never appear in report. If you want deleted channels to appear in report again, please follow Regenerate 24 hour POP report section under 24 Hour POP Report Features section. 7. View 24 hour POP report In POP report configuration page, click on View Report button, 24 hour POP report opens in a new browser window/tab. Page 26 of 61

a) Non Licensed Version Page 27 of 61

You may also Print / Export results. Export options include EXCEL & a FamilyWare POP Report batch zip file. Snapshot of POP export zip file Snapshot of 24 hour POP report in excel Page 28 of 61

b) Licensed Version 24 hour POP report screen shot Licensed Version Page 29 of 61

Page 30 of 61

24 hour POP report screen shot continued Licensed Version Page 31 of 61

24 hour POP report screen shot continued - Licensed Version You may also Print / Excel Export results. 8. Save 24 hour POP Report Licensed Version In POP reports page (refer to POP report configuration page screen shot for bullet 3), click on Save Report button. Report is saved to database and 24 hour details page is displayed. 24 Hour POP Report Features Licensed Version 1. Search 24 hour POP Report a) In left panel, click on POP reports link. Select 24 hour POP reports option. If you know the name of the report, enter in name field otherwise leave the name field empty. You can search on date range the report is created by selecting Date Range option and setting start and end dates. If you do not remember report creation date, select Any Date option. Click on Find button. Snapshot of POP reports page b) List page with 24 hour POP reports is displayed. You can sort on columns by clicking on column headers. Page 32 of 61

c) Click on report name link or select check box against a 24 hour report and click on display icon as shown in below screen shot. d) 24 Hour POP Report Details page as shown below is displayed. Details page for 24 hour POP report allows user to view report, regenerate 24 hour POP report, upload, download and delete attachments, save 24 hour POP report as HTML and excel. This page also allows user to export 24 hour POP report bundle and import the same into another server. This report bundle includes any uploaded attachments along with measurement files that are used in creating 24 hour POP report. Page 33 of 61

Snapshot of 24 Hour POP Report Details page 2. View 24 hour POP report To view report, click on View 24 Hour and Miscellaneous Reports button. 3. Regenerate 24 hour POP report This feature allows regeneration of 24 hour POP report if there are any data entry mistakes or if analog channels or digital channels measurements for respective tests need to be pulled from different measurement file during data configuration for 24 hour POP report. Repeat steps in bullet 1 to select a 24 hour report. In 24 Hour POP Report Details page, click on Regenerate 24 Hour and Miscellaneous Reports button. POP report configuration page as shown in below screen shot is displayed: Page 34 of 61

Edit all the required information. To pull data from a different measurement file into Analog and Digital Channels table, select a measurement file in Import Data from file drop down. If a file is already selected in Import Data from File drop down, then selecting blank in drop down will clear data in Analog and Digital Channels Table. Click on View Report button to view report. All data changes are not saved until Save Report button is clicked. 4. View measurement files used in 24 hour POP report Repeat steps in bullet 1 to select a 24 hour report. To view all measurement files used in report, click on Measurement Files text in measurement files section. This will open all measurement files used in report in a different Page 35 of 61

window. This gives the option to print measurement files too. To view each file individually, click on file name in Measurement Files section. 5. Upload attachments Repeat steps in bullet 1 to select a 24 hour report. To upload any files that are used in creating a 24 hour report, in attachments section, click on browse button. Choose file and click on open button. Click on upload button. The maximum allowed combined size of all attachments is 16MB. 6. Download attachments Repeat steps in bullet 1 to select a 24 hour report. To download attachments, in Attachments section, select a radio button next to attachment name and click on download button. 7. Delete attachments Repeat steps in bullet 1 to select a 24 hour report. To delete any attachment, select a radio button next to attachment name and click on delete button. Page 36 of 61

8. Save report as HTML or XLS Repeat steps in bullet 1 to select a 24 hour report. To save report as HTML or XLS click on Save as HTML or Save HTML as XLS buttons. 9. Export Familyware files Repeat steps in bullet 1 to select a 24 hour report. To generate files needed for uploading to POP Familyware software, click on POP Export button. This will prompt you to save the zip file that contains the required text files. 10. Export Report bundle This feature allows user to export 24 hour POP report from a TPP server and import report into another TPP Server. Repeat steps in bullet 1 to select a 24 hour report. Click on Export Report Bundle button. A pop dialog will ask you to save the file. Click on save button to save the file. All attachments that are uploaded along with measurement files that are used in report creation are exported with this bundle. 11. Import 24 hour POP report This feature allows user to import 24 hour POP report that was previously exported from a different TPP Server. a) In left panel, click on POP reports link. In POP reports page, click on Browse button. Page 37 of 61

b) In file dialog, navigate to the location where the report bundle is present. The report bundle will have 24hour_JDSUPOP_zip as extension. Select the bundle and click on open button. c) Click on upload button. If there are no errors, report will be imported to TPP. Page 38 of 61

12. Delete 24 hour POP report This feature allows user to delete 24 hour POP reports from TPP. Repeat steps a, b and c in bullet 1 to view 24 hour POP reports list page. Select checkboxes for each 24 hour POP report that you like to delete. Click on X icon as shown in below snapshot. A 24 hour POP report is not deleted if it s in use by a six month report. Snapshot explaining 24 hour POP reports delete functionality: How to Create System Summary Report Licensed Version System Summary Report is the aggregation of data from 24 hour POP reports generated for test points under a system. This report is generated only if all the selected 24 hour POP reports are under same system. In left panel, click on POP reports link. In POP reports page, select 24 hour POP reports option and click on Find button. List of 24 hour POP reports is displayed. Select check boxes for 24 hour POP reports that are generated for Test Points under same system. Click on System Summary Report button. Page 39 of 61

Fill information in fields in System Summary page. In the above, value for Required Minimum Test Points is automatically calculated on filling in Subscriber Count. Click on View System Report button to view report. Below is the screen shot of sample System Report. Page 40 of 61

Snapshot of Sample System Report Page 41 of 61

How to Create Six Month Report Licensed Version 1. Search for 24 hour POP reports In left panel, click on POP reports link. In POP reports page, select 24 hour POP reports option and click on Find button. List of 24 hour POP reports are displayed. Select check boxes for exactly two 24 hour POP reports and click on 6 icon. Note: - A 6 Month Configuration page is displayed only when System, Test Point and the required matching fields as set in POP Reports Settings page are same cross selected 24 hour POP Reports. While performing matching between two selected 24 hour POP reports, space is removed from the values and then compared. For Ex: - if system name in first 24 hour POP report is Beech Grove and system name in second 24 hour POP report is BeechGrove they are considered equal as the space is removed from the system names before checking if they are equal. The same is done before comparing all required system information fields between two selected 24 hour POP reports. In 6 Month Configuration page, enter report name and click on Save Report. Report is saved to database and 6 month details page is displayed. Page 42 of 61

Page 43 of 61

Page 44 of 61

Page 45 of 61

You may also Print / Excel Export report. Page 46 of 61

2. Ignore Channel Frequency and Type Errors during 6 Month Deviation Calculation Between two selected 24 hour POP reports, if there are any channels that differ in frequency or type then following button is displayed as shown below: Click on the above highlighted button. The report is refreshed and frequency and channel type errors are ignored during 6 month deviation test. Below is the screen shot of 6 Month POP report when frequency and type errors are ignored: The 6 Month Deviation Result column will display status as ignored for channels where frequency or type errors are ignored. If you do not want to ignore frequency and channel type errors, click on the Do not Ignore Frequency and Channel Type Errors during Six Month Deviation Result Calculation button as shown below: Page 47 of 61

The report is refreshed without ignoring frequency or channel type errors during 6 Month deviation status calculation. Once the required action is done, please click on Save Report button otherwise report is not saved. 6 Month POP Report Features Licensed Version 1. Search 6 month Report a) In left panel, click on POP reports link. Select 6 month POP reports option. If you know the name of the report, enter in name field otherwise leave the name field empty. You can search on date range the report is created by selecting Date Range option and setting start and end dates for you search. If you do not remember report creation date select Any Date option. Click on Find button. b) List page with 6 month POP reports is displayed. You can sort on columns by clicking on column headers. c) Click on report name link or select check box against a 6 month report and click on display icon as shown in below screen shot. Page 48 of 61

d) 6 Month Report Details page as shown below is displayed. 2. View 6 month report Repeat steps in bullet 1 to select a 6 month report. Click on View Report button to view report. 3. View 6 month Summary report Repeat steps in bullet 1 to select a 6 month report. Click on View Just 6 Month Summary Report button to view report. Below is the screen shot of sample six month summary report: Page 49 of 61

Page 50 of 61

4. View 24 hour reports Repeat steps in bullet 1 to select a 6 month report. Click on + icon for a 24 hour report. 24 hour report details page is displayed. Refer to section 24 Hour POP Report Features for more details. 5. Upload attachments Repeat steps in bullet 1 to select a 6 month report. To upload any files that are used in creating a 24 hour report, in attachments section, click on browse button. Choose file and click on open button. Click on upload button. The maximum allowed combined size of all 6 month report attachments is 48 MB which includes 16MB total size per 24 hour POP report attachments and 16MB total size for 6 Month report attachments. 6. Download attachments Repeat steps in bullet 1 to select a 6 month report. To download attachments, in Attachments section, select a radio button next to attachment name and click on download button. 7. Delete attachments Repeat steps in bullet 1 to select a 6 month report. To delete any attachment, select a radio button next to attachment name and click on delete button. Page 51 of 61

8. Save report as HTML or XLS Repeat steps in bullet 1 to select a 6 month report. To save report as HTML or XLS click on Save as HTML or Save HTML as XLS buttons. 9. Export Report bundle This feature allows user to export 6 month POP report from a TPP server and import report into another TPP Server. Repeat steps in bullet 1 to select a 6 month report. Click on Export Report Bundle button. A pop dialog will ask you to save the file. Click on save button to save the file. The exported bundle includes attachments that are uploaded for 6 month report along with two 24 hour POP report bundles with their attachments and measurement files that are used in report creation. 10. Import 6 month POP report This feature allows user to import 6 month POP report that was previously exported from a different TPP Server. a) In left panel, click on POP reports link. In POP reports page, click on Browse button. Page 52 of 61

b) In file dialog, navigate to the location where the report bundle is present. The report bundle will have 6month_JDSUPOP_zip as extension. Select the bundle and click on open button. c) Click on upload button. If there are no errors, report will be imported to TPP. Page 53 of 61

11. Delete 6 month POP report This feature allows user to delete 6 month POP reports from TPP. Repeat steps a, b and c in bullet 1 to view 6 month POP reports list page. Select checkboxes for each 6 month POP report that you like to delete. Click on X icon as shown in below snapshot: Snapshot explaining 6 month POP reports delete functionality: Page 54 of 61

APPENDIX A. TPP Test Reporting System POP Report Details When Report Name is considered unique? A Report Name is considered unique when following set of fields is unique Report Name, System, Test Point, Test Point Location, Headend/Hub and Municipality Note: - Test Point Location, Headend/Hub and Municipality can be empty. When does a 24 hour POP report fails? The overall status of 24 hour POP report is fail if either of 24 hour POP tests or Analog Measurement Test (applicable only for licensed version) or Digital Measurement Test (applicable only for licensed version) status is fail. 24 hour POP report status is fail if: 1. Channel type or frequency does not match among measurements 2. Missing channels in measurement files 3. 4 measurement files are not used 4. If measurements are not with in 6, 12, and 18 hours from the 1st test (plus or minus 1 hour). 5. If 24 hour deviation is not with in 24 Hour Deviation Limit as set in POP Reports Settings page. The default value is 8dB. 6. If Adjacent Visual Signal Level a.k.a Adjacent Channel is not with in Maximum Adjacent Channel limit as set in POP Reports Settings page. The default value is 3dB. This 3dB is applicable for both analog and digital channels. 7. If there are pair of analog (TV or Dual) channels which happen to be with in 6 MHz frequency separation and there is no adjacent channel data measured. 8. If Minimum Visual Signal Level is less than Minimum Video Level Limit as set in POP Reports Settings page. The default value is 3dBmV. 9. If Minimum Digital Level is less than Minimum digital Level Limit as set in POP Reports Settings page. The default value is -10dBmV. 10. If converter type is none or standard and Aural Carrier Level a.k.a V/A Level is not in between MINIMUM STANNDARD VIDEO/AURAL CARRIER LEVEL DELTA and MAXIMUM STANDARD VIDEO/AURAL CARRIER LEVEL DELTA. If converter type is baseband and V/A level is not in between MINIMUM BASEBAND VIDEO/AURAL CARRIER LEVEL DELTA and MAXIMUM BASEBAND VIDEO/AURAL CARRIER LEVEL DELTA. For converter type of standard or none, default min and max are 10dB and 17 db respectively. For converter type of baseband, default min and max are 6.5dB and 17 db respectively. 11. If Analog Delta Video is not with in Maximum Analog Delta Video Limit. Maximum Analog Delta Video Limit is calculated as follows using Maximum Analog Delta Video and Analog Delta Video Offset as set in POP reports settings page: If bandwidth > 300MHz then Page 55 of 61

Maximum Analog Delta Video Limit = Maximum Analog Delta Video + Analog Delta Video Offset for each additional 100MHz above 300 MHz. else Maximum Analog Delta Video Limit = Maximum Analog Delta Video The default limit and offset are 10dB and 1dB respectively. 12. If Digital Delta Video is not with in Maximum Digital Delta Video Limit. Maximum Digital Delta Video Limit is calculated as follows using Maximum Digital Delta Video anddigital Delta Video Offset as set in POP reports settings page: If bandwidth > 300MHz then Maximum Digital Delta Video Limit = Maximum Digital Delta Video + Digital Delta Video Offset for each additional 100MHz above 300 MHz. else Maximum Digital Delta Video Limit = Maximum Digital Delta Video Note: - If there are no analog channels i.e. only digital channels are present or if there exists analog channels that do not fall in 6 MHz separation with analog channel next to it, and if there is no Adjacent Visual Signal data for any channel then Adjacent Visual Signal status is displayed as No data and it is not taken into consideration for the overall report status calculation. Analog Measurement Test status (applicable only for licensed version) is fail: 1. If Visual Carrier Frequency is not with in Minimum Visual Carrier Frequency Offset and Maximum Carrier Frequency Offset from channel frequency as set in POP reports settings page. The default values are -5 to 5 KHz respectively. 2. If Aural Carrier Frequency Offset is not with in Minimum aural Carrier Frequency Offset and Maximum Aural Carrier Frequency Offset as set in POP reports settings page. The default values are 4.495 to 4.505 MHz respectively. 3. If Carrier to Noise is less than Minimum Carrier to Noise as set in POP reports settings page. The default value is 43 db. 4. If Hum is greater than Maximum Hum as set in POP reports settings page. The default value is 3%. 5. If In-Channel Frequency Response is not with in Minimum Analog In-Channel Response and Maximum Analog In-Channel Response. The default values are -2 db to +2 db respectively. 6. If cable system is Non Coherent and Carrier Triple Beat (CTB) is less than Minimum Standard Coherent Disturbance as set in POP reports settings page. The default value is 51 db. If cable system is coherent and Carrier Triple Beat is less than Minimum Baseband Coherent Disturbance as set in POP reports settings page. The default value is 47 db. 7. If cable system is Non Coherent and Carrier Second Order (CSO) is less than Minimum Standard Coherent Disturbance as set in POP reports settings page. The default value is 51 Page 56 of 61

db. If cable system is coherent and Carrier Second Order is less than Minimum Baseband Coherent Disturbance as set in POP reports settings page. The default value is 47 db. 8. If any of the above tests does not test minimum required analog channels. Note: -Minimum required test channels criteria is applied only if data is available for the channels for the respective test. Digital Measurement Test status (applicable only for licensed version) is fail: 1. If Visual Carrier Frequency is not with in Minimum Visual Carrier Frequency Offset and Maximum Carrier Frequency Offset from channel frequency as set in POP reports settings page. The default values are -5 to 5 KHz respectively. 2. If MER is less than Minimum QAM 256 Signal Quality for 256 QAM type or less than Minimum QAM 128 Signal Quality for 128 or Minimum QAM 64 Signal Quality for 64 as set in POP reports settings page. The defaults are 36 for each QAM type. 3. If QAM type is not either of 64 or 128 or 256. 4. If PreBER is greater than Maximum PreBER as set in POP reports settings page. The default value is 1.00-E9. 5. If PostBER is greater than Maximum PostBER as set in POP reports settings page. The default value is 1.00E-9 6. If In-Channel Frequency Response for digital channel is greater than Maximum Digital In- Channel Response. The default value is 3 db. 7. If Group Delay is greater than Maximum Group Delay as set in POP reports settings page. The default value is 100 ns. 8. If Gain Compression is greater than Maximum Gain Compression as set in POP reports settings page. The default value is 1.0 %. 9. If EQ Stress @ 0.5 is greater than Maximum EQ Stress @ 0.5 as set in POP reports settings page. The default value is -10 dbc. 10. If EQ Stress @ 1.0 is greater than Maximum EQ Stress @ 1.0 as set in POP reports settings page. The default value is -15 dbc. 11. If EQ Stress @ 1.5 is greater than Maximum EQ Stress @ 1.5 as set in POP reports settings page. The default value is -20 dbc. 12. If EQ Stress @ 4.5 is greater than Maximum EQ Stress @ 4.5 as set in POP reports settings page. The default value is -30 dbc. Note: -Minimum required test channels criteria is not applied for digital channel tests. Conditions to generate a 6 month POP report Licensed Version A six month report is generated under the following conditions: 1. If measurements in each of 24 hour tests are with in 6, 12 and 18 hours from the 1 st test (plus or minus) 1 hour. 2. If System and Test Point along with required matching fields as set in POP reports settings page are same across selected 24 hour reports. Page 57 of 61

3. If selected two 24 hour reports are 5-7 months a part. The 5-7 month interval is calculated between last test date of first 24 hour report and first test date of second 24 hour report. Note: - TPP does not validate whether the reports were generated in months of Jan/Feb and Jul/Aug. When does a 6 month POP report fail? Licensed Version The overall status of six month report is fail 1. If the total number of files from two 24 hour reports is less than 8 2. If status of any of 24 hour report is fail or if six month deviation > 8 db 3. If channel line up does not match across all 8 test results 4. If channel frequencies or channel types do not match between selected 24 hour POP reports and frequency or type errors not ignored during 6 month report creation. 5. If System or Test Point information do not match across selected 24 hour POP reports. Configuring the POP Report To configure Signal Level Units: From the TPP Web Application, select system preferences from the left panel. Under the global system preferences section, select measurements.. Select the desired Signal Level Units value and press Save. To configure a custom report header: From the TPP Web Application, select system preferences from the left panel. Under the global system preferences section, select report header. Check the use custom report header box. Enter the HTML for the Address and Custom sections. Via the file system, install a new custom icon and press Save. POP Default Limits Below table lists the default POP limit values used by TPP. Limit Name Limit Value Comment 24 Hour Deviation 8 db Maximum Adjacent Channel 3 db Maximum Analog Delta Video 10 db Analog Delta Video Offset 1 db For bandwidth > 300 MHz, Offset will be added to Maximum Analog Delta Video limit for each additional 100 MHz above 300 MHz Maximum Digital Delta Video 10 db Digital Delta Video Offset 1 db For bandwidth > 300 MHz, Offset will be added to Maximum Analog Delta Video limit for each additional 100 MHz above 300 MHz Minimum Video Level 3 dbmv Video level for analog channels. Page 58 of 61

Minimum Digital Level -10 dbmv Video level for digital/docsis channels. Minimum Standard Video/Aural Carrier Level Delta 10 db This limit applies to converter types of None and Standard Maximum Standard Video/Aural Carrier Level Delta 17 db This limit applies to converter types of None and Standard Minimum Baseband Video/Aural Carrier 6.5 db Level Delta Maximum Baseband Video/Aural Carrier 17 db Level Delta 6 Month Deviation 8 db Minimum Aural Carrier Frequency Offset 4.495 MHz Maximum Aural Carrier Frequency Offset 4.505 MHz Minimum Visual Carrier Frequency Offset -5 KHz Maximum Visual Carrier Frequency Offset +5 KHz Minimum Analog In-Channel Frequency -2 db Response Maximum Analog In-Channel Frequency +2 db Response Minimum Carrier to Noise 43 db Minimum Baseband Coherent Disturbance 47 db Minimum Standard Coherent Disturbance 51 db Maximum Hum 3 % Min QAM 256 Sig Quality 35.8 db MER Min QAM 128 Sig Quality 35.8 db MER Min QAM 64 Sig Quality 36.3 db MER Maximum Digital In-Channel Response 3 db Maximum Group Delay 100 ns Maximum Gain Compression 1 % Maximum Pre-BER 1.0E-9 Maximum Post-BER 1.0E-9 Maximum EQ Stress At 0.5 µs -10 dbc Maximum EQ Stress At 1.0 µs -15 dbc Maximum EQ Stress At 1.5 µs -20 dbc Maximum EQ Stress At 4.5 µs -30 dbc Page 59 of 61

APPENDIX B. Summary of FCC Proof of Performance Test Overview of FCC Proof of Performance Test Requirements For details of the Proof of Performance test requirements, refer to the Code of Federal Regulations (CFR) 47, part 76. This book is available from the US Government Printing Office, Mail Stop: SSOP, Washington, DC 20402-9328. Many cities in the US have US Government Printing Office stores that sell Government publications directly to the public. Who must run the tests? All systems with 1000 or more subscribers. Smaller systems are required to comply with the Cumulative Leakage Index requirements (including quarterly measurements) but are not normally required to demonstrate proof of performance of the other technical standards. The technical standards are expected to be met by all systems -- but small systems don't need to prove it. When do the tests need to be run? Most tests need to be conducted "at least twice each calendar year (at intervals not to exceed seven months)". The "24 hour" tests "shall be measured and recorded, along with the date and time of the measurement, once every six hours (at intervals of not less than five hours nor more than seven hours after the previous measurement), to include the warmest and the coldest times, during a 24 hour period in January or February and in July or August". The 24 hour test is the only one required during those particular months. The color tests (Chrominance to Luminance Delay Inequality, Differential Gain, and Differential Phase), need to be conducted at least triennially (once every three years). How many channels need to be tested? Many tests are required on all "NTSC or similar video channels" of the system. Other tests are required "a minimum of four (4) channels plus one additional channel for every 100 MHz, or fraction thereof, of cable distribution system upper frequency limit (e.g. 5 channels for cable system upper frequency limit of 101 to 216 MHz; 6 channels for cable television systems with a cable distribution system upper frequency limit of 217-300 MHz; 7 channels for cable television systems with a cable distribution upper frequency to 300 to 400 MHz, etc.)." All channels are required to meet all of the technical standards. However, for certain of the technical standards, you only need to demonstrate "proof of performance" on a sampling of the channels... How are the test channels selected? "The channels selected must be representative of all the channels within the cable television system." Generally, systems select channels from across the system's spectrum. How many test sites do we need? For systems from 1000 to 12,500 subscribers, tests "... shall include measurements taken at six (6) widely separated points. However, within each cable system, one additional test point shall be added for every additional 12,500 subscribers or fraction thereof (e.g., 7 test points if 12,501 to 25,000 subscribers, etc.). " Also, there must be at least one test point "for each portion of the cable system served by a technically integrated microwave hub". Note that this does not mean a test point for each fiber node. Page 60 of 61

Where, in the system, are the tests conducted? Test points "shall be balanced to represent all geographic areas served by the cable system. At least onethird of the test points shall be representative of subscriber terminals most distant from the system input and from each microwave receiver (if microwave transmissions are employed), in terms of cable length". Measurements may be made at convenient monitoring points in the system so long as the data reflects system performance for nearby subscribers. Some measurements (visual signal level and 24 hour tests) are required to be measured "at the end of a 30 meter (100 foot) cable drop that is connected to the subscriber tap,..." Usually, all tests in the field are conducted at the end of a 100 foot drop cable. The 100 foot drop cable simulates typical drops provide to homes. For tests at the output of a set-top converter, connect the converter to the end of the drop cable. Are there specified procedures for each test? In general, no. However, good engineering practices are to be used for all tests. For some measurements, the rules refer to documents such as the "NCTA Recommended Practices for Measurements on Cable Television Systems, 2nd edition, November 1989". A review of that document is an excellent starting point. Of course, measurement equipment and techniques are continually evolving. There is a lot of test equipment available today that make the tests much easier than some of the procedures described in the NCTA documents. Before you decide to use any procedure, you should of course, have a thorough understanding of the test requirements and the algorithms used by your test gear. Do not blindly trust automated test gear simply because it provides "numbers"! Where do we send the test results? Unless told otherwise by the FCC or your franchise authorities, you simply keep the data on file for at least five years. The test data is required to be made available to the FCC or local franchise authorities upon request. What happens if we don't pass? Tests have been run on over 50 systems, many of them multiple times. So far, one system has "passed" all the requirements (it passed one of the two times in which tests were run on it). Given the complexity of today's cable systems, the thousands of mechanical connections involved the number of back hoes and other rodents in our society; something, somewhere, is likely to be broken at any given point in time. The most important thing is to run the tests, find the problems, fix them, and keep a log of the whole process. Of course, carrier leakage problems should be addressed as soon as they are discovered. Authorities tend to frown when aircraft start honing in on bad splices. Where do I go for more information on Proof Testing? http://www.fcc.gov/mb/engineering/601.html http://www.fcc.gov/mb/engineering/604.html Page 61 of 61