"Sophisticated Model Railroad Electronics"

Similar documents
"Sophisticated Model Railroad Electronics"

Azatrax Model Railroad Track Signal Control - Single Track

Scale Track System. 21 Century y Signal System 2-Rail Manual

Bill of Materials: Super Simple Water Level Control PART NO

MSS-CASCADE User Manual

POINTS POSITION INDICATOR PPI4

Noise Detector ND-1 Operating Manual

SIGNALING PRACTICES ON PROTOTYPE AND MODEL RAILROADS

Simplified Signaling for Modelers

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Product Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes

RGB-3400-X RGB SEQUENCER / 3-CHANNEL UNIVERSAL LED DIMMER

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

T850 Day & Night Security Camera

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

Light-It Decoder p/n Lighting decoder w/built-in white LED

Bruce Chubb s Computer/Model Railroad Interface (C/MRI) 101- The Basics

How To Build Megavolt s Small Buffered JTAG v1.2

Multi-Key v2.4 Multi-Function Amplifier Keying Interface

PASS. Professional Audience Safety System. User Manual. Pangolin Laser Systems. November 2O12

Obtained from Omarshauntedtrail.com

/16. Lionel Double Signal Bridge Owner s Manual

GAUGEMASTER PRODIGY EXPRESS

Pixie Construction Notes

TKEY-K16. Touch CW automatic electronic keyer. (No moving parts no contacts) Assembly manual. Last review: March 15, 2018

autotwo Automatic Mixer Operation Manual

SM DMX LIGHTING CONTROLLER OWNERS MANUAL. May 19, 2009

Colour Explosion Proof Video Camera USER MANUAL VID-C

Light Emitting Diodes (LEDs)

4x4 Component Matrix over CAT-5

8 PIN PIC PROGRAMMABLE BOARD (DEVELOPMENT BOARD & PROJECT BOARD)

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

UAV Ultimate Atari Video A7800

By CHANNEL VISION. Flush Mount Amplifier A0350

Complete Train Control. Run Your Trains, Not Your Track!

Modellbahn Digital Peter Stärz

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Layout Design For Signaling

Lionel #148 Dwarf Signal Owner s Manual /11

( stored on ) also accessible from

GEKCO SUBCARRIER REFERENCE OSCILLATOR MODEL SRO10 OPERATION/SERVICE MANUAL

Visit the Abrams Railroad Empire at

2. Depletion MOSFET (DE-MOSFET).

16 Stage Bi-Directional LED Sequencer

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

Layout Design For Signaling

Table of Contents. Read This First.2. Introduction by Jim Fosgate...3. Unpacking..4. Tubes and Tube shield Installation 5. Product Placement...

Chameleon Labs Model 7720

Instruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1

Phone (440) Fax Wireless Rear Observation System With Night Vision Camera

Complete Train Control. Run Your Trains, Not Your Track!

TeamWork Kits Installation Guide

LE1014W & LE1014MP Ultra-Thin Drive-Select DCC Decoder Art. No Version 4.6 April 2003

DZ143. Z Scale. Mobile Decoder 1.25 Amp/2 Amp Peak 4 FX 3 Functions, 0.5 Amp. Fits Many Z, N and HO Scale Locomotives

Build your own: Track Display

SX7 e l e c t r o n i c c r o s s o v e r

AVS50 USER GUIDE. 2.4GHz Audio/Video Sender System - AVS50

AUTOMATIC VIDEO LOSS A/B SWITCH

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

EG4015. Digital Generator Governor Controller User Manual

Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16)

SUBCARRIER TRANSFER FILTER INSTRUCTION BOOK IB622702

Aspect 2 Circuit Digital Scene Control

Pelican PL-957. Adding additional Tos Link (Digital Optical) inputs, and / or IR Remote

Model R177M and R177S Baseband Switch

OWNER'S MANUAL MYCRO SUB

LDG FT-Meter For Yaesu FT-857 and FT-897 Version 1.1

Warner Photoscanner MCS-500 Series LED Photoelectric Control

MODEL PA II-R (1995-MSRP $549.00)

Tailgate module BEXPRO PRINS VSI

VK-P10SE WARRANTY REGISTRATION FORM

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

Table of contents. Opening the Overhead Monitor... 4 Precautions Care And Maintenance... 5 Operating OHM102/153 Monitor...

LDG M-7600 External Meter for Icom IC-7600

Lab 7: Soldering - Traffic Light Controller ReadMeFirst

DM1624, DM1612, DM812

MONO AMPLIFIER KIT ESSENTIAL INFORMATION. Version 2.2 CREATE YOUR OWN SPEAKER DOCK WITH THIS

Complete Train Control. Run Your Trains, Not Your Track!

AT-AUTO (tm) QRO Keyline Upgrade Kit Installation Manual

FD104CV. Installation and Operation Manual 10.4 LCD MAN FD104CV. TECHNICAL SUPPORT , or Document Number: Rev:

SY-HDBT-100 Extender Set

JS007WQK HEAVY DUTY WIRELESS REVERSING KIT 7 LCD DIGITAL QUAD RECORDING MONITOR with WATERPROOF CCD CAMERA

MRC DISPATCHER TRACKSIDE DECODER

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

MclNTOSH MODEL C-4 and C-4P

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

GA A26497 SOLID-STATE HIGH-VOLTAGE CROWBAR UTILIZING SERIES-CONNECTED THYRISTORS

HTP1502W1 Remote Controlled Multicolor Lighting System

Assembly and Operating Instructions for HiViz.com Kits

SY-HDBT-SLIM-100S Extender Set

Modifying the RW1127 and similar TWTs for 24GHz

Australian Technical Production Services

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

T/E-Extender TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...4

Color Organ Triple Deluxe II.

Introduction 1. Green status LED, controlled by output signal ST. Sounder, controlled by output signal Q6. Push switch on input D6

Turnout Decoder TD Maxi. User Manual - version 0.1.6

Transcription:

LOGIC RAIL TM "Sophisticated Model Railroad Electronics" TECHNOLOGIES 21175 Tomball Pkwy Phone: (281) 251-5813 Suite 287 email: info@logicrailtech.com Houston, TX 77070 http://www.logicrailtech.com Block Animator (BA-1) Instructions Revised 10/20/18 Getting started Thank you for purchasing a Logic Rail Technologies product! Please familiarize yourself with all the instructions prior to installing this board. This version of the Block Animator (model BA-1) provides 3-color signaling for LED-based 3-light (common anode) and searchlight-style signals. It can also be used with LED-based 2-light (common anode) signals; of course then you ll only get 2-color signaling. The Block Animator (BA) provides automatic operation of two 3-color block signals in a semi-prototypical way. Four photocells are used for bidirectional train detection. The layout of the signals and photocells is illustrated below. The BA operates the signals as described next. In the absence of any trains the two signals will be green. Now consider a train traveling eastbound. When photocell W1 is covered signal WB will change from green to red and will remain red as the train continues eastbound and subsequently covers signal W2. When the train then covers photocell E2 signal EB will change from green to red. Once the train has totally uncovered photocells W1 and W2 then signal WB will change from red back to green. As the train continues eastbound towards photocell E1 signal EB will remain red. Once the train has passed over photocell E1 and totally uncovers both it and photocell E2 signal EB will change to yellow; this mimics the behavior of the train entering the next block. After a time delay (10 or 30 seconds; see below) signal EB will change to green. Signal operation for a westbound train is similar with signal EB changing from green to red and back to green while signal WB changes from green to red to yellow and back to green. You should make all of the connections to the BA before applying power to it. You can mount the BA anywhere it is convenient underneath your layout using the four mounting holes provided. The holes will accept #4 screws; do not enlarge the holes as damage to the circuit board can result and your warranty will be voided! The BA board has a set of 6 configuration switches on it. Each switch is described below. Switch Name Meaning when OFF/OPEN Meaning when ON/CLOSED SETUP BA is in normal operating mode BA is in photocell setup mode DELAY Yellow to Green delay is 30 seconds Yellow to Green delay is 10 seconds SIG_EB EB signal is a 3-color type EB signal is a searchlight type SIG_WB WB signal is a 3-color type WB signal is a searchlight type YELHUE Yellow hue for searchlight signals is more reddish Yellow hue for searchlight signals is more greenish APPRL Approach Lighting is Disabled Approach Lighting is Enabled Approach Lighting The concept of Approach Lighting is quite simple. A signal remains dark (not illuminated) until a train approaches it (i.e. the block in advance of the signal is occupied). This has been primarily used in the western U.S. in remote locations where signal equipment operates on battery power. Having the signals unlit most of the time saves battery power as well as prolongs the life of the bulbs. The rule for illumination is simple: the signal shall be illuminated when the preceding block is occupied. The BA supports this feature (when the APPRL switch is ON/CLOSED) and works as follows. Signal EB will be illuminated whenever an eastbound train covers photocell W1 and will keep signal EB illuminated until photocell E2 is covered and then subsequently uncovered. Note that if the eastbound train covers and then uncovers photocell W1 but after 35 seconds hasn t covered photocell E2, then the BA will assume the train has actually reversed direction and will turn the signal off. Similarly, signal EB will also be illuminated whenever a westbound train covers photocell E2 and will keep signal EB illuminated until photocell W1 is covered and then subsequently uncovered. The same 35 second timeout mechanism is in effect for this direction of travel too. Signal WB will operate in a similar manner with respect to photocells E1 and W2. You can turn approach lighting on or off at any time. Hopefully it is obvious that if you turn this feature off then the signals will be illuminated all the time! 1

Searchlight Signals with Bipolar LEDs (Tomar Industries, Oregon Rail Supply, etc) To select a searchlight signal on the BA you must turn ON/CLOSE the appropriate configuration switch. The LED used in model searchlight signals is commonly called a bipolar or tri-color LED. This type of LED has two elements inside of a single housing; one element is green and the other is red. There are two ways that these LEDs are internally wired. One has two leads and the other has three leads; the three-leaded variety is the most common. The BA supports either one as shown in Figures 1a & 1b; these diagrams depict the wiring for the Eastbound signal head; wiring for the Westbound signal head is equivalent. You MUST use resistors with LED-based signals! Because the BA provides +5V power to the LED we recommend a resistor value of 150 ohms. We have included six resistors with this product; you will not use all of them for this type of signal. With a three-leaded variety you can choose to use one resistor in the common path (as shown in Figure 1b) or you could choose to use one resistor in EACH of the color (i.e. G & R) connections (this is NOT illustrated). NOTE: The Y and C terminals are not used with this signal type! Figure 1a two-lead searchlight signal Figure 1b three-lead searchlight signal You can adjust the yellow hue on the searchlight signal(s) using the configuration switch labeled YELHUE on the circuit board. If the switch is ON/CLOSED then the yellow hue will be more greenish and less red; if the switch is OFF/OPEN then the yellow hue will be more reddish and less green. The BA provides a novel feature with searchlight signals that we call TrueLens. This duplicates the prototype signal behavior of having the signal BRIEFLY show yellow when the signal changes from green to red. Signals with 3 LEDs (Tomar Industries, Oregon Rail Supply, BLMA, etc) To select signals using 3 individual LEDs you must have the appropriate switch in the OFF/OPEN position. The BA directly controls 3-light LED signals wired in a common anode (the anode is the positive side of the LED) arrangement. Virtually all brands of 3-light signals are wired this way. One known exception is those from Integrated Signal Systems which are wired in a common-cathode arrangement. We offer another version of the Block Animator (model BAD-CC) for controlling this type of signal. You MUST use resistors with LED-based signals! Because the BA provides +5V power to the LED we recommend a resistor value of 150 ohms. We have included six resistors with this product. Since only one LED will be illuminated at a time you can choose to use a single resistor in the common anode path or individual resistors in each of the LED cathode paths. The individual resistor scheme is illustrated in Figure 2. NOTE: The C terminal is not used with this signal type! Figure 2 3-light signal 2

Signals with 2 LEDs (Tomar Industries, Oregon Rail Supply, etc) To select a 2-light signal you must have the appropriate switch in the OFF/OPEN position. The BA directly controls 2-light LED signals wired in a common anode (the anode is the positive side of the LED) arrangement. Virtually all brands of 2- light signals are wired this way. One known exception is those from Integrated Signal Systems which are wired in a common-cathode arrangement. We offer another version of the Block Animator (model BAD-6) for controlling this type of signal. You MUST use resistors with LED-based signals! Because the BA provides +5V power to the LED we recommend a resistor value of 100 ohms; this is less than the 150 ohm resistors we recommend (and which are included with the BA) because there is a voltage drop through the diodes shown below. Since only one LED will be illuminated at a time you can choose to use a single resistor in the common anode path or individual resistors in each of the LED cathode paths. The individual resistor scheme is illustrated in Figure 3. The diodes are used to combine the yellow and green outputs. NOTE: The C terminal is not used with this signal type! Figure 3 2-light signal The s The photocells should be mounted between the rails. Drill a 9/64" hole through the ballast, roadbed, and sub-roadbed. For the smaller scales this drilling may end up hitting the ties. Take your time so you don t mangle them! Figure 4 illustrates the placement of a photocell in between the rails. Insert the leads of the photocell into the hole from the top of your layout. One of the photocell leads has a piece of insulation on it so be sure the two leads don't touch each other (you won't damage anything if they do but the circuit won't work properly!) If the leads do not Figure 4 photocell placement protrude enough from the underside of your layout then it will be necessary to extend the leads; soldering wires to them is the most common method; make sure you insulate any connections you make to the photocell leads so that they don't short out. Once you have wired the photocells to the BA and verified their operation you may wish to put a dab of white glue under the photocells to hold them in place; make sure you don't get glue on the top surface of the photocells as this may prevent it from operating properly. Figure 5 illustrates the photocell wiring; make sure you have the photocells in the correct order as shown at the top of page 1. s do not have any polarity so you can connect either lead to the GND terminal and connect the remaining lead to the appropriate photocell input. The spacing between the outer photocells (W1 and E1) and inner photocells (E2 and W2) depends upon how long of a signal block you wish to define for each signal. However, keep in mind that there is a 35 second timeout that the BA uses. This means that if it takes more than 35 seconds for a train to cover the nearest inner photocell after uncovering an outer photocell then the BA will think the train has actually backed up and exited the block! 3

Figure 5 photocell wiring The photocells require a light source above them to function properly. On most layouts the room lighting should be sufficient. However, if any of the photocells are located in an area that doesn't get much overhead lighting or if you have simulated "nighttime" operations then it will be necessary to locate a light source on the layout near the photocell(s). Street lights and yard lights are common light sources. Locate the light source slightly to the left or right of the photocell(s) and not directly over it; this will allow the BA to still properly detect a train that has stopped over a photocell with the gap between cars over the photocell. sensitivity setup You can adjust the sensitivity of each photocell on the circuit board using a small slotted head screwdriver. Along one each of the board are four potentiometers (or pots ) that are labeled "W1", E2, W2 or E1. The BA supports a SETUP mode to make this adjustment process easier. To enable this mode, you must have the switch labeled SETUP in the ON/CLOSED position. In this mode the signals will not change colors. The BA circuit board contains a red LED near the configuration switches; this LED will assist you in setting the photocell sensitivity. Now follow these steps: 1. Remove all obstacles that may be covering the photocells or blocking overhead light to them. 2. Insert the blade of the screwdriver (from the edge of the circuit board, not from the center of the board) into the adjustment pots, one at a time. Turn the screwdriver completely counter-clockwise (left) in all FOUR of the pots. 3. For the adjustment pot labeled W1 turn the screwdriver clockwise (right) until the on-board LED just lights up. Then turn the screwdriver back counter-clockwise until the LED goes out. 4. Repeat step 3 for the three remaining pots. 5. Exit SETUP mode by putting the SETUP switch in the OFF/OPEN position. The signals should now operate properly. It may be necessary to repeat this procedure if layout lighting conditions change significantly. Turning the pots clockwise adjusts for brighter overhead lighting conditions while turning the pots counter-clockwise adjusts for dimmer overhead lighting. Signal delay The signal color delay (when the signal changes from yellow to green) can be either 10 seconds or 30 seconds. Choose the value based on your own personal preference. To select 10 seconds the configuration switch labeled DELAY must be ON/CLOSED; for 30 seconds the switch must be OFF/OPEN. You can change this as you wish even when the power to the BA is on. 4

Power The BA accepts AC or DC power (7-16V). Power consumption for LED signals is approximately 60mA (including the signals). If you are only using a single BA then use the AC IN terminals to provide power (polarity doesn t matter). You can use the AC or DC accessory terminals on your throttle/power pack provided the voltage doesn t exceed 16V. You can even power the circuit from the rails if you re using command control (e.g. DCC, Railcommand, etc); in this case use the AC IN terminals on the BA. If you are using more than one BA you can power them all from a single DC source as shown in Figure 6 below. Block Animator Westbound Eastbound Block Animator Westbound Eastbound Figure 6 DC power Alternate signal positioning Rather than place the signals and photocells as shown on page 1 you may choose to locate the signals at the opposite ends of a long section of track as shown in the next drawing. All wiring should follow what has been previously described. Please note that with this usage of the Block Animator you CANNOT enable approach lighting; you MUST have the APPRL switch in the OFF/OPEN position in order to have proper signal behavior. Signal EB Signal WB W1 E2 W2 E1 W E Other Applications Please contact us if you are interested in knowing how to interlock your signal (i.e. force it to red) with the position of a turnout or if you are interested in controlling a dual head signal. We have an instruction supplement that covers these applications. You can also access this documentation online from our website at http://www.logicrailtech.com/lrt_docs.htm. Minimizing electrical noise effects from other sources that may cause false triggering Switch machines, switch motors and electrical uncouplers are notorious for generating electrical noise when they are energized. Such noise can be inadvertently coupled onto the BA s photocell connections which can then lead to false triggering of the signal circuit. The first remedy to try is to make sure that wiring for those devices is kept apart from the photocell wiring. This may not always be practical (especially if you re interlocking the signal head(s) with turnout position as described above). If that s the case, adding decoupling/filter components to the BA circuit will usually eliminate the false triggering. The drawing below illustrates what needs to be done. Note that capacitors C1 and C3 are polarized so make sure you connect them correctly; C2 has no polarity. Also, pay attention to the component location as outlined below in the parts list. The numbers in parentheses are Radio Shack part numbers. The drawing only shows one photocell. Each photocell will need its own R1 and C3 components; only one C1 and C2 are needed for each BA. 5

It may also be necessary to add filtering to the power source for the offending item. For example, if you are using switch motors powered by a DC (unipolar or bipolar) power source you may need to add filter capacitors to that power source. We suggest a 0.1ufd/50V ceramic disk capacitor (such as C2 above) in parallel with a 100ufd/35V electrolytic capacitor (similar to C1 above, but obviously a higher value). Connect them similar to the way C1 & C2 are connected above (i.e. positive lead to positive power output; negative lead to the negative power output or ground). Finally, if noise problems still exist you may need to use coaxial cable for the photocell connections. Connect the shield of such a cable to GND terminal on the BA and connect the center wire to the appropriate photocell terminal. Using an infrared emitter and detector instead of the photocell It is possible use infrared emitter and detector pairs instead of the photocells for train detection. The wiring for one photocell input is shown below. When the infrared beam is not obstructed from the detector the output of the detector will be approximately 0.2V. When the infrared beam is obstructed the output of the detector will essentially appear like an open circuit to the BA s photocell inputs which will be interpreted like a covered photocell. E1 W2 E2 W1 5V DC GND AC IN Warranty This product is warranted to be free from defects in materials or workmanship for a period of one year from the date of purchase. Logic Rail Technologies reserves the right to repair or replace a defective product. The product must be returned to Logic Rail Technologies in satisfactory condition. This warranty covers all defects incurred during normal use of this product. This warranty is void under the following conditions: 1) If damage to the product results from mishandling or abuse. 2) If the product has been altered in any way (e.g. soldering). 3) If the current or voltage limitations of the product have been exceeded. Requests for warranty service must include a dated proof of purchase, a written description of the problem, and return shipping and handling ($4.00 inside U.S./$8.00 outside U.S. - U.S. funds only). Except as written above, no other warranty or guarantee, either expressed or implied by any other person, firm or corporation, applies to this product. 6

Troubleshooting If your signal is not reacting properly when a particular photocell is covered or uncovered then you can perform the following tests. First, perform the photocell setup routine previously described. If one or more of the photocells does not function properly then you know it/they is/are faulty. If the photocells are determined to be OK then you might have a problem with the BA, the signal, or the wiring between them. If you re using a searchlight signal and the signal is red when you think it should be green and vice versa then you probably just need to reverse the R and G connections. Technical Support We hope the preceding instructions are sufficient for answering any questions you might have about the installation of this product. However, technical support is available should you need it. We would ask that you first contact your place of purchase for assistance. If you still need further assistance then please do not hesitate to contact us. You can reach us via phone, fax, mail and email; our contact information can be found on the top of page 1. 7