Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

Similar documents
RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

SM DMX LIGHTING CONTROLLER OWNERS MANUAL. May 19, 2009

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

TL MEMORY CONTROL CONSOLE OWNERS MANUAL 02/17/2005. Version 0.6

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

TL5024 MEMORY LIGHTING CONSOLE OWNERS MANUAL. Version 1.01

OWNERS MANUAL. Revision /29/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Stratos Duo RGB. User Manual. Order code: EQLED371

Opti Tri White Par. User Instructions

Stage Wash 7x 10W LED Moving Head (RGBW)

Fusion 120 Zoom. User Manual. Order code: EQLED068

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

EPAR QA. User Instructions

EPAR QW. User Instructions

Spectra Batten (Order code: LEDJ95)

NEO-STB-0004 Neo-Flash 300 RGB User Manual

USER MANUAL Table of Contents

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

LED-PAR200B USER MANUAL. COLORsplash 200B

SquareLED - Aura Bar & Matrix Beam Light 100

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL

USER MANUAL Table of Contents

SPECIFICATIONS: Model: Supply Voltage: LED: Weight: Size: Fuse: Power Consumption: Working Position: Duty Cycle: DMX Channels:

TABLE OF CONTENTS INTRODUCTION

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do

APOLLO DESIGN TECHNOLOGY 4130 Fourier Drive Fort Wayne, IN USA Phone: Fax:

USER S MANUAL

Design LED 36WA. Elation Professional 4295 Charter Street Los Angeles, Ca Rev 3/08/07

LED Thunder S-150 Code 1097

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

Chroma-Q Color Block PSU-30

WaferPar QUAD-W 7 CKU (US) / CKE (EU) USER MANUAL

LED-BANK4 USER MANUAL. COLORbank 4

thinpar 38

ORDER CODE: EQLED65 USER MANUAL

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

Flat LED Par Can Light

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

Design LED 36. Elation Professional 4295 Charter Street Los Angeles, Ca Rev. 11/17/06

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. Auto-ranging Power Supply. Replaceable Fuse.

Elektralite LED Cool White Dazer

MONOPRICE. SoftStage 80-Watt COB LED Stage PAR (RGB) with 30 and 80 Lenses. User's Manual P/N

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. Auto-ranging Power Supply. Replaceable Fuse.

STAGE SETTER-8. User Instructions. Elation Professional 4295 Charter Street Los Angeles Ca

Introduction: The Dekker is part of American DJ s continuing pursuit for creating high quality affordable intelligent fixtures.

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

USER MANUAL Table of Contents

Chroma-Q Studio One 100 D

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

Warning! To prevent or reduce the risk of electrical shock or fire, do. Caution! There are no user serviceable parts inside this unit.

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

Owner Handbook. Jupiter Blackhole. LED UV Flood

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

Hex-color RGBAW+UV LED strip light

LIGHT COPILOT II. elationlighting.com Internet:

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

ProPlex Digital RGB Drive PortableMount TMB 24/7 Technical Support

USER MANUAL Table of Contents

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

FloppyDrive 3x2 24V and 12V PortableMount USER MANUAL

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

SV-LCD50. Installation and User Guide. Thin-Film Transistor (TFT) Liquid Crystal Display (LCD) Color Rear Vision Monitor. Version 1.

ELED PAR RGB ZOOM. User Instructions. Elation Professional 6122 S. Eastern Ave. Los Angeles CA

Mini LED Pin Spot Light Model: PLS00571

ALO 060 DMX LED scanner

American DJ. User Instructions. Model: Mega Bar 50RGB

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

Jelly Par Profile System Introduction Unpacking: Introduction: Customer Support: Warning! Caution! User Instructions

LED Pixel Track Pro ORDERCODE 42205

SAFETY AND NOTICE TABLE OF CONTENTS

TABLE OF CONTENTS. 1. Before you Begin... 3 What is Included... 3 Unpacking Instructions... 3 Text Conventions... 3 Icons... 3 Safety Notes...

Glow P54 White LED Par

CYBER PAK. User Instructions.

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

USER MANUAL (SSDL-3201RGB)

192 Channel DMX Controller

ElektraLite lightstream

Spherion Tri LED General Information Unpacking: Introduction: Customer Support: Warning! Caution!

LED IP65 Slimline Par RGBWA +UV 7x12W

LED Spot 300W. Please read this user manual before your operation

Truss Light COB LED 30W

Warning! To prevent or reduce the risk of electrical shock or fire, do. Caution! There are no user serviceable parts inside this unit.

BROTHER, BROTHER & SONS

ARENA PAR ZOOM. user manual. ELATION ARENA PAR ZOOM user manual

User Instructions. 16 SCB Sync Station.

SyncGen. User s Manual

Information specifically for: V1.1

PRODUCT SPECIFICATIONS

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

BROTHER, BROTHER & SONS

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Venus W36 LED Moving Wash

American DJ. User Instructions. American DJ

Design LED 60 Strip WA. Elation Professional 6122 S Eastern Ave Los Angeles, Ca Rev.

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

Transcription:

Page 1 of 6 FEATURES AND SPECIFICATIONS LEDS: 18, 6W each (Warm White, Cool White, 2in1) Beam angle: 25º or 45 Control system: DMX512 + Stand Alone Modes DMX channels: 1/2/3/4/5 DMX connectors: 3 pin XLR Voltage: 120-240 VAC 50/60Hz Max power consumption: 120 Watts Refresh Rate: > 3000Hz Color Temp.: 3200K - 7000K Cooling: Internal Fan Body material: Die Cast Aluminum Body color: Black Size: 9.9"L x 9.9"W x 4.5"D (without brackets) Weight: 10 lbs. (4.5kg) DESCRIPTION The FXLD618FRP2I4 is a variable white LED lighting fixture. It is suitable for stage, disco, night club, and other artistic applications. It has several stand-alone control modes and can operate via a DMX512 external signal. A double yoke enables the fixture to be operated in several positions. INSTALLATION LOCATION The FXLD618FRP2I4 is rated IP20 and is intended for INDOOR USE ONLY. Locate the unit in a well ventilated area away from moisture and heat. Keep the vent holes clear. Holes are provided on the yokes to install a lighting bar pipe clamp. Use a safety cable when hanging the fixture. POWER CONNECTIONS CAUTION RISK OF ELECTRIC SHOCK The FXLD618FRP2I4 has a blue turn and lock connector for power input. A compatible power cable is provided for connection to a 120 VAC, 15 Amp, 60Hz, grounded service. Push the blue connector on the cable straight into the blue connector on the unit and twist approx. 1/8 turn clockwise to latch it. The white turn and lock connector on the unit is used to pass power on to another FXLD618FRP2I4 unit. A mating white connector is also provided. Caution is advised since the line cord is rated for approx. 7 Amps maximum. THE SAFETY GROUND TERMINAL ON THE POWER CABLE MUST BE USED. DMX CONNECTIONS A system using DMX control should be connected as a chain of devices. In other words the control signal cable should proceed from the controller to the first receiving device and then to others in a continuous "daisy chain" fashion. The fixture has a DMX IN and a DMX OUT connector to be used to connect the chain. The control cable should NOT be split into a multiple run star arrangement with a cable running from the controller directly to each receiving device pack.

Page 2 of 6 DMX CONNECTOR PIN ASSIGNMENTS This unit uses a 3 pin XLR type connectors. The FXLD618FRP2I4 receives a DMX signal on the 3 pin MALE connector on one side of the unit. The 3 pin FEMALE connector is used to connect the next DMX device on the control chain. DMX TERMINATION A DMX chain should be terminated at the last receiving device on the chain. This is done by installing a commonly available 1/4 Watt, 120 Ohm resistor across the DATA - and DATA + wires at the last device. If you have only a few fixtures very close together and a very short run to the controller then you may be able to operate without the terminator. OPERATION A control panel on one side of the unit is used to set the operating options. It consists of an LED display and four buttons (MENU, UP, DOWN, and ENTER) CONTROL PANEL the UP and DOWN buttons. For DMX operation the FXLD618FRP2I4 fixture can be configured as a 1 channel, 2 channel, 3 channel, 4 channel or 5 channel unit. Set the CHXX menu to 01 (1 channel), 02 (2 channel), 03 (3 channel), 04 (4 channel), or 05 (5 channel). Detailed information on DMX channel operation is given in the tables DMX VALUES AND FUNCTIONS. Manual Operation If there is no DMX signal provided to the unit then setting any of these will result in the unit that was set acting as a master. DMX signals will override all manual settings. The unit has a signal receive LED on the menu display. If the unit is flashing the unit is not receiving signal either from a DMX controller or from a master light. Color Select (CSXX) For additional manual operations you can use the Color Select menu (CSXX) to select one of three preset color temperature settings. Color Change (CCXX) MENU UP DOWN ENTER Push MENU to access the operating options. Then use UP and DOWN to scroll through the available choices. When you reach the option you want to set or change - push ENTER. Now you can view the current setting for the option and/or change it. Push ENTER to save your changes and activate the option. See the "MENU NAVIGATION" diagram for additional details. There are 9 operation modes: DMX, Color Fade, Color Change, Color Select, Manual Level (2 selections), Demo, Sound, delo. The display will default to 0XXC. This is a display of the current LED plate temperature. The fan on the unit will only turn on when temperature is at or above 45ᵒC DMX OPERATION The color change mode cycles through 3 preset color temperature settings at a user defined speed. Use the CCXX menu to set the rate of speed at which the colors change. The range is from 01 to 99. 99 is fastest and 01 is the slowest. COLOR FADE (CFXX) The Color Fade mode cycles smoothly through 3 preset color temperature settings. Use the CFXX menu to set the speed and activate the option. The range is from 1 to 99. 99 is fastest. Warm White/Cool White MANUAL LEVEL CONTROL You can operate the individual color levels manually using the E000, and u000 menus. Use the UP and DOWN buttons to change the level, Push ENTER when done. The range is 000-255 (255 is maximum). Use the Addr menu to set the starting address of the unit. You can set the starting address of the unit with

Page 3 of 6 DEMO MODE (deno) The Demo mode is a stand-alone mode designed to test the unit. The Demo mode will not work if the unit is receiving DMX. If service is required, contact the dealer from whom you purchased the item, or contact the Lightronics, Service Department, 509 Central Drive, Virginia Beach, VA 23454. Tel: 757 486 3588. SOUND MODE (Soun) The unit reacts to low end bass sounds by cycling through 3 preset color temperatures. There are no other settings within this mode. Brightness on the sound mode can be set using a DMX controller. The default for the unit is full brightness. DIMMER CURVE MODE (del0) Option not supported at this time. MAINTENANCE AND REPAIR CAUTION DO NOT OPEN UNIT RISK OF ELECTRIC SHOCK RISK OF FIRE TROUBLESHOOTING Check that you have power applied to the unit. Check the DMX control cable. Check the address settings of the unit and the controller. CLEANING Do not use harsh chemicals or solvents when cleaning the fixture. A mild detergent can be used sparingly if needed. Ensure that the unit is completely dry before re-use. REPAIR The fixture contains a 2 Amp 250VAC, fast acting, 5mm x 20mm externally accessible fuse. Replace the fuse ONLY with the same size and type. The FXLD618FRP2I4 does not contain any other user serviceable parts. Internal service on the unit by other than Lightronics authorized agents will void the warranty.

Page 4 of 6 MENU NAVIGATION

Page 5 of 6 DMX VALUES AND FUNCTIONS 1 CHANNEL MODE 1 0-255 Master Dimmer 2 CHANNEL MODE 1 0-255 Warm White 2 0-255 Cool White Level 3 CHANNEL MODE 1 Master Dimmer 2 0-255 Warm White 3 0-255 Cool White Level 4 CHANNEL MODE 1 Master Dimmer 2 Strobe Control 3 0-255 Warm White 4 0-255 Cool White Level 5 CHANNEL MODE 1 Master Dimmer 2 Strobe Control 3 0-255 Warm White Level 4 0-255 Cool White Level 5 0-255 Color Temperature

WARRANTY This product is warranted for a period of TWO YEARS from the date of purchase against defects in materials and workmanship. This warranty is subject to the following restrictions and conditions: A) If service is required, you may be asked to provide proof of purchase from an authorized Lightronics dealer. B) This warranty is valid only for the original purchaser of the unit. C) This warranty does not apply to damage resulting from abuse, misuse, accidents, shipping, and repairs or modifications by anyone other than an authorized Lightronics service representative. D) This warranty is void if the serial number is removed, altered or defaced. E) This warranty does not cover loss or damage, direct or indirect arising from the use or inability to use this product. F) Lightronics reserves the right to make any changes, modifications, or updates as deemed appropriate by Lightronics to products returned for service. Such changes may be made without prior notification to the user and without incurring any responsibility or liability for modifications or changes to equipment previously supplied. Lightronics is not responsible for supplying new equipment in accordance with any earlier specifications. G) This warranty is the only warranty either expressed, implied, or statutory, upon which the equipment is purchased. No representatives, dealers or any of their agents are authorized to make any warranties, guarantees, or representations other than expressly stated herein. H) This warranty does not cover the cost of shipping products to or from Lightronics for service. I) Lightronics Inc. reserves the right to make changes as deemed necessary to this warranty without prior notification. Lightronics Inc. 509 Central Drive Virginia Beach, VA 23454 20100211