Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Similar documents
Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

DX-10 tm Digital Interface User s Guide

Sentinel I24 Digital Input and Output Configuration

XYZ Cinemas - ecna Configuration 12/12/2013 Table of Contents

TeamWork Kits Installation Guide

Exercise 4-2. Counting of Actuator Cycles EXERCISE OBJECTIVE & & &

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

IL591 SECTION D Rev /2011. Tek-SAFE NC150R Area of Rescue Assistance System. Operation, Installation and Service Manual

Westerstrand T/T- display

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Foreword: The purpose of this document is to describe how to install and configure Neets 4 relay box

HITACHI. VisionCube. Service Manual

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

RF Wireless Receiver (Model S4PU-DC-ANT3)

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

AUTOMATIC VIDEO LOSS A/B SWITCH

Operating Instructions for Throttle Valves Using VRC Valve Positioner

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

Model VS-2A 2-Port VGA Switch with Audio & Serial Control

Automatic Transfer Switch Control PLC Operator s Manual

SBL /SBLG Series Wireless Clock

Figure 1: Device components

7 Day Digital Programmer 3 Channel Surface Mount

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

Aspect 2 Circuit Digital Scene Control

Master Time Clock MTC Users Manual

Dissolve Control Programming : Projector/Dissolve Control Hook-Up

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. M Series Dimmer. Manual Version 1.1

Quick Reference Guide

Installation and Operation Manual

AES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Caution. Hanging the Screen:

FB10000 Error Messages Troubleshooting

SSPT724A Timer Quick Start Guide

MATE3 Owner s Manual Addendum

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

A Motor can be in many groups, by assigning additional channel# on it.

Junior Max (JR Max ) Controller

ST8-WiFi Timer. Installation Guide and Operations Manual. English MIN M D YYYY

SceneStyle2 User Guide

TITLE BOX PAGE ONLY. DO NOT MAKE FILM DO NOT PRINT. MATERIAL: White 16lb (60g/m sq), uncoated, prefer recycled stock Ink: Black

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

USCG Exam questions related to PLCs by Frank Owen, Maine Maritime Academy, 23 October 2018

EVENT INPUT/OUTPUT MODULE [PUME]

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

LinTronic. TableTop series. Hardware version 6. Updated

ANALOG RADIO MIXER. Flexible. Affordable. Built To Last.

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Access Control Keypad for MK-DV, JB-DV

CG-1 CAMERA-GUARD INSTRUCTION BOOK IB647501

SHUTTLE WITH INFRA-RED DETECTION SAS2-IR

MODEL 2018 OPERATION MANUAL Firmware Version

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

IQACO Changeover Switch

( stored on ) also accessible from

5530M and 5530MHV Adaptatone Installation Sheet

Site Installation Model MP-8433

Build A Video Switcher

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

OPERATION AND MAINTENANCE

SECURITRON PRIME TIME MODEL DT-7 INSTALLATION AND OPERATING INSTRUCTIONS

Overview: Specifications: Installation Instructions:

Model 1476-C SuperQuad HR

switching, distribution, interfacing and control products for computer graphic, multi-media and audio visual systems integration

Solid-State Digital Timer

TeamWork 601 Kit Installation Guide

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442)

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

Programming Guide and User Manual INS # Model # CKM. ControlKeeper M

VNS2210 Amplifier & Controller Installation Guide

Miniguard HF-2 with Prox Reader or TELEPROX

Flat-Bed Module Recorders

PLL2210MW LED Monitor

User Guide. Automated Xenon Entertainment Lighting System

VNS2200 Amplifier & Controller Installation Guide

FF DUAL FORMAT DJ MIXER USERS MANUAL

Setting up the Setting up the Dragonfly 1 v June

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

Digital Lighting Systems, Inc.

Quick Reference Guide

Identification - electrical services

DMX and 4000 air circuit breakers from 800 to 4000 A

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

Rapid-Air. Operating Instructions. C-T-L w/ 100D Series Servo Feed Control Ver. C. s/n & Later

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Transcription:

Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. These manuals are designed to facilitate the exchange of information related to cinema projection and film handling, with no warranties nor obligations from the authors, for qualified field service engineers. If you are not a qualified technician, please make no adjuatments to anything you may read about in these Adobe manual downloads www.film-tech.com

Systems Inc., 284 Broadway, Huntington Station, NY 11746 631.421.1230 FAX 631.421.1274 Model 2035 Series II Deluxe Automation Instructions The Kelmar Deluxe Custom Automation System is comprised of a Basic System with OPTIONAL features so that it can be suited to all applications. System Configurations: 1. Basic System 2. 0 60 Minute Show Start Timer Option 3. Built in SYNC Operation Option ANY OR ALL OPTIONS CAN BE ADDED TO THE BASIC SYSTEM. * BASIS SYSTEM FEATURES CONTROL OF: * Projector Drive Motor * Xenon Lamphouse * Changeover Dowser * Exciter Lamp * Dolby Audio System (or similar) * House Light Dimmer * Stage Light Dimmer * Screen Curtain * Non Sync (dry and 120 VAC Output) * Lights up early for House Light Dimmer * Built in Alarm * Full Remote Control Capability * Curtain Slide Projector ** MANUAL CONTROL SWITCHES PROVIDED FOR: * Projector Drive Motor * Xenon Lamp * Exciter Lamp * Changeover Dowser * House Light Dimmer * Stage Light Dimmer * Curtain Projector * Lens/Masking Switch BASIC SYSTEM SEQUENCE OF OPERATIONS A. SHOW START: (Start Button or Clock Option) 1. Changeover CLOSE 2. Motor & Lamp ON 3. Non-Sync OFF 4. House Lights [MID] or DOWN 5. Stage Lights OFF 6. Changeover OPEN, Exciter ON 7. Dolby MONO B. CROSS FRAME CUE: 1. House Light Dimmer DOWN 2. Lens/Masking SCOPE or FLAT Pre-Select 3. Audio System MONO or STEREO Pre-select

Page 2 SEQUENCE OF OPERATIONS (continued) C. INBOARD CUE: 1. House Light Dimmer [MID] or UP D. OUTBOARD CUE: 1. House Light Dimmer [UP] 2. Stage Light Dimmer UP 3. Changeover CLOSE, Exciter OFF 4. Motor & Lamp OFF (Selectable, as C.O. Closes or as Film Runs thru) 5. Non-Sync ON 6. Dolby Non-Sync ****OPTIONAL SHOW START CLOCK: 0-60 Minute Clock Timer can be Preset to Start the show after selected interval. *****OPTIONAL SYNC OPERATION PACKAGE: Provides SYNC [interlok operation with 2 Automation Systems, Additional Module installs in main cabinet, plugs into chassis, has control button on panel. For Multiple Auditoriums a Sync Selector Unit is available to SYNC 4 Automations in any of 4 different combinations. The Sync Selector Units may be ganged together for 8, 12, or 16 Auditoriums, permitting any 4 SYNC operations at once. I DENOTES DIMMER POSITION WITH KELMAR H Series DIMMER CONTACT: Kelmar Systems Inc. 284 Broadway Huntington Station, New York 11746 Phone (631) 421 1230

Page 3 The Kelmar Deluxe Automation is contained in one steel enclosure with dimensions as follows: WIDTH 16 1/4 HEIGHT -17 5/8 DEPTH -6 1/2 The Deluxe Automation Cabinet should be mounted on the FRONT WALL of the Projection Room, Below the Observation Port, with the TOP of the cabinet 3-6 A.F.F. (Above Finished Floor). Refer to Riser Diagram (Drawing No. 1309), for the wires required between the Deluxe Automation and the various devices to be controlled. Verify the devices to be controlled, for example: is there a Curtain and a Masking motor? Verify if the Automations will be INTERLOKED or not, if they are to be interloked, verify how many and where the SYNC SELECTOR MODULE(S) should be located. Refer to Instructions included with the SYNC MODULE and the SYNC SELECTOR MODULE for Installation Details. Verify what kind and type of REMOTE control system will be installed. The Kelmar Deluxe Automation can be used with the Kelmar Deluxe Automation Remote Control or with the Kelmar Remote Status System. The Kelmar Deluxe Automation Remote Control provides Remote operation of the: START and STOP buttons, Mode, ALARM light and buzzer, Run Light, Fault Light, Stop light. The Kelmar Remote Status System is available in 4, 6, and 8 Auditorium Modules, with or without an Alarm latch, and provides PROJ. RUN, FAULT, and ALARM LIGHT and BUZZER for each Automation, and a RESET button for the latch module. Since the Kelmar Deluxe Automation can be used with a variety of Projectors, Audio Systems, Xenon Lamps, Dimmers etc. Consult the instructions furnished with the device for terminations. The Kelmar Dimmers include an interface schedule for the automation terminations. ALL CONTROL CIRCUITS (except the 120 VAC Non-Sync term. 19,20) ARE DRY SWITCH CONTROL CIRCUITS. For assistance with terminations CONTACT: Kelmar Systems Inc. 284 Broadway Huntington Station, New York 11746 Phone (631) 421-1230

Page 4 KELMAR DELUXE AUTOMATION- TERMINATION SCHEDULE Term. No. Term. No. 1. OUTBOARD CUE ROLLER 26. 120 VAC INPUT AUTOMATION FEED * 2. INBOARD CUE ROLLER 27. 120 VAC NEUTRAL AUTO. FEED 3. FAILSAFE MICRO SWITCH 28. GROUND (SWITCHING COMMON) 4. GROUND (SWITCHING COM.) 29. MOTOR FEED 5. REMOTE START 30. MOTOR 6. REMOTE C.O. CLOSE [I/L] 31. XENON LAMP 7. REMOTE STOP BUTTON 32. XENON LAMP 8. REMOTE PROJ. RUN PL(12v) 33. C.O. FEED 9. REMOTE PROJ. STOP PL(12v) 34. C.O. OPEN 10. REMOTE FAULT PL(12v) 35. C.O. CLOSE 11. REMOTE ALARM OUT 12 VAC 36. C.O. CLOSE [N.C.] (CINEMECCANICA) 12. HOLD FOR INTERLOK 37. EXCITER INPUT (EXCITER SUPPLY +) 13. 12 VAC OUTPUT 38. EXCITER LAMP (+) 14. GROUND (SWITCHING COM.) 39. HOUSE DIMMER CONTROL FEED (STRAP,REMOVE FOR I/L) 15. C.O. CLOSE (LOGIC) 40. HOUSE DIMMER SHOW START OUT 16. LENS/MASKING FEED 41. HOUSE DIMMER FEATURE CUE (CROSS) 17. LENS/MASKING FLAT 42. HOUSE DIMMER INBOARD CUE 18. LENS/MASKING SCOPE 43. HOUSE DIMMER SHOW END 19. LINE 44. STAGE DIMMER FEED 120 VAC NON-SYNC 20. NEUTRAL 45. STAGE DIMMER UP 21. AUDIO SWITCHING FEED 46. STAGE DIMMER DOWN 22. AUDIO SWITCHING MONO 47. SCREEN PROJECTOR FEED 23. AUDIO SWITCHING STEREO 48. SCREEN PROJECTOR OUTPUT 24. AUDIO SWITCHING NON-SYNC 49. NON-SYNC DRY INPUT 25. 50. NON-SYNC DRY OUTPUT * FOR SYNC (INTERLOK) ALL INTERLOKED AUTOMATIONS MUST BE POWERED FROM THE SAME PHASE

Page 5 ** KELMAR DELUXE AUTOMATION-TERMINATION SCHEDULE Page 2 ** 51. CROSS FRAME CUE ROLLER 52. START LOGIC OUTPUT (STRAP, REMOVE ONLY FOR AUD. DELUXE MODULE) 53. START CIRCUIT INPUT 54. CURTAIN CONTROL FEED 55. CURTAIN CONTROL OPEN 56. CURTAIN CONTROL CLOSE 57. THIRD DIMMER FEED (OPTIONAL) 58. THIRD DIMMER LOWER (OPTIONAL) 59. THIRD DIMMER RAISE (OPTIONAL) 60. 61. 62.

Page 6 AUTOMATION CONTROL SWITCHES: SW S1 F1 S2 FUNCTION AUDIO FEATURE PRE-SELECT (CROSS CUE) Pre-set to MONO or STEREO for Feature Format. activated by CROSS CUE, or S4. MAIN FUSE POWER ON-OFF SWITCH Turns Power to Automation Unit ON or OFF. PL-1 Feature Mode L.E.D. Lights after CROSS CUE has been detected or Manually advanced by S4. S3 PB-1 PL-2 PB-2 LENS/MASKING FEATURE PRE- SELECT (CROSS CUE) Pre-set to SCOPE or FLAT for FEATURE Format activated by CROSS CUE, or S4. AUTOMATION START BUTTON, press to START show with Automation. Button lights to indicate that PROJ. is running. PLEASE NOTE: Automation WILL NOT START WITH FAILSAFE DOWN. TIMER CYCLE LIGHT- Indicates that cam Timer is in CYCLE. Will light after start button is pressed or OUTBOARD CUE has been detected. AUTOMATION STOP/RESET BUTTON, press to STOP show while running Automation. Top light indicates that PROJ. is NOT Running, Bottom Light indicates that the FAILSAFE is DOWN (FAULT). The Automation WILL NOT START if the Fault Light is ON. The STOP Button also functions as a RESET for the Interval Show Start Timer (OPTIONAL) After the Timer has been started with S6, it can be turned OFF by pressing STOP. S4MANUAL CUE SWITCH-Used to MANUALLY provide an INBOARD or CROSS CUE. INBOARD position provides House Dimmer MID Output, CROSS position provides FEATURE preselects of 51 and S3. Use to RE-START the Show after a Film Break, or special showings. PB-3 S5 ALARM CANCEL PUSHBUTTON -used to turn off the ALARM Buzzer. SHOW END MODE used to select the Function of the OUTBOARD CUE to either NORMAL, the projector shuts off after the Tail runs through, or AUTO-STOP (Mid-Platter Intermission) the projector shuts off as the C.O. Closes. OPTIONAL START TIMER SWITCH: S6 INTERVAL TIMER MODE * [CLOCK OPTION] Used to START the Interval TIMER start Clock. 3 position toggle switch. NORMAL Position center. To START Interval Timer, Press to RIGHT. For a PRE-SET MID- PLATTER INTERMISSION (Clock Starts Automatically) set S6 to INTER. START (LEFT) and SHOW END MODE SWITCH S5 to AUTO-STOP. TIMER will START as Projector shuts OFF. IF MID-PLATTER Inter. is used, Reset S5 or S6 prior to end of show or timer will Re-start. NOTE: S8 Will NOT CLOSE C.O. if a NORMALLY CLOSED, energized while OPEN C.O. is used (term #36). A Normally Closed C.O. will function properly with Automation.

Page 7 AUTOMATION CONTROL SWITCHES: SW S7 S8 S9 S10 FUNCTION MANUAL MOTOR, Turns Projector Motor ON or OFF Manually. Leave in AUTO position for Automation Operation. MANUAL C.O., Opens or Closes CHANGEOVER Manually, PLEASE NOTE: S8 willnot CLOSE C.O. if a NORMALLY CLOSED, energizedwhile OPEN C.O. is used (term #36). A Normallly Closed C.O. will function properly with Automation. MANUAL LENS/MASKING SWITCH, Manually controls LENS Changer or MASKING connected to terminals 16, 17, 18. MANUAL LAMP SWITCH, Turns Xenon Lamp ON or OFF Manually. Leave in AUTO position for Automation Operation. S11 MANUAL HOUSE DIMMER, Controls DIMMER manually, Connected to Terminals 39, 41, 43. S12 S13 SYNC SELECTOR* [SYNC OPTION] used to select SYNC operation. Refer to instructions with SYNC OPTION. MANUAL EXCITER SWITCH, used to turn EXCITER LAMP On or OFF Manually. Leave in AUTO position for Automation Operation. S14 MANUAL STAGE DIMMER, Controls STAGE DIMMER Manually, Connected to Terminals 44, 45, 46. S15 LIGHT CURTAIN used for Light Curtain, or Intermission Slide Projector Control. In ON position the device will be ON at all times, in OFF, it will be OFF at all times in AUTO it will go OFF as the C.O. OPENS and come ON as the C.O. CLOSES. Leave in AUTO position for Automation Operation. * DENOTES SWITCH FURNISHED AS PART OF OPTIONAL ITEM, BASIC UNIT NOT PROVIDED WITH THIS SWITCH.

Page 8 Automation utilizes 3 different Cues: * KELMAR DELUXE AUTOMATION CUE PLACEMENT * GENERAL- The Kelmar Deluxe INBOARD CUE- Emulsion Side OUTBOARD CUE-Emulsion Side CROSS CUE-Base Side, Across Frame Line. CUES ARE TO BE USED AS FOLLOWS: CUE PLACEMENT: CROSS CUE- Directs Automation to Pre-Selected Feature Mode Format. Switches S1 and S3, and Dimmer Down. INBOARD CUE- Lights up early. (Dimmer MID). OUTBOARD CUE- Show End. (Dimmer UP). FOR PRESENTATION WITH SHOW START TRAILERS AND 1 FEATURE 1. Place a CROSS FRAME CUE Between the show start trailers and the Feature. This Cue should be placed 2-6 BEFORE the FEATURE. 2. Place an INBOARD CUE at the START of the CREDITS. 3. Place an OUTBOARD CUE l0-6 BEFORE the LAST frame of the show. SET switches S1 and S3 to Feature Format SET switch SS to NORMAL FOR PRESENTATIONS WITH 2 FEATURES: (NO INTERMISSION BETWEEN FEATURES) 1. Place a CROSS FRAME CUE between the show start trailers and the Feature. This Cue should be placed 2-6 BEFORE the FEATURE. 2. Place an INBOARD CUE at the START of the CREDITS (feature 1). 3. Place a CROSS FRAME CUE 2-6 BEFORE Feature 2. 4. Place an INBOARD CUE at the START of the CREDITS (feature 2). 5. Place an OUTBOARD CUE l0-6 BEFORE the LAST frame of the show (feature 2). SET switches 81 and S3 to Feature 1 Format Re-SET switches 51 and 83 during Feature 1 to Feature 2 Format. SET SW. 85 to NORMAL.

Page 9 ** KELMAR DELUXE AUTOMATION-CUE PLACEMENT Page 2 ** FOR PRESENTATIONS WITH 2 FEATURES (INTERMISSION BETWEEN FEATURES): 1. Place a CROSS FRAME CUE between the show start trailers and the feature. This cue should be 2-6 BEFORE feature 1. 2. Place an INBOARD CUE at the START of the CREDITS (feature 1). 3. Place an OUTBOARD CUE l0-6 BEFORE the END of feature 1. 4. Place a CROSS FRAME CUE 25-0 AFTER the START of Feature 2. 5. Place an INBOARD CUE at the START of the CREDITS (feature 2) 6. Place an OUTBOARD CUE l0-6 BEFORE the END of feature 2. SET Switches S1 and S3 to feature 1 Format. Switch SS to AUTO-STOP Interval Timer for Intermission length Switch S6 to INTER. START DURING FEATURE 1 Re-Set switches 51 and S3 to Feature 2 Format. DURING FEATURE 2 Re-Set switch SS to NORMAL. GENERAL- A CROSS Cue provides Lens/Masking and Audio Output from selector switches 51 and S3 and also a Dimmer Down Command. S1 and S3 have center OFF positions, if there is no format change, these switches may be left in the CENTER OFF position. An INBOARD Cue provides a Dimmer MID command. If it is desired, to raise and lower the House lights, cue the show accordingly.

Page 10 KELMAR DELUXE AUTOMATION OPTIONAL START TIMER GENERAL - The Optional Show Start Timer mounts in the center of the control panel and plugs in to the Automation chassis plug P2. Clock Option includes timer control switch S6. If the Clock option was ordered with the automation, it will be installed in the system at the factory. If a clock option is to be added to an existing unit, install as follows: 1. Remove Blank off plate from control panel. 2. Remove clock from housing by removing screw at bottom of dial face, lift up handle, slide clock out. 3. Mount Clock housing to control panel, note TOP. 4. Mount control switch S6, so that the MOMENTARY Side is to the right. 5. Plug harness into plug P2 on chassis. 6. Slide clock back into housing, fold handle, secure. OPERATION- The Interval Timer is used to start the show after a selected delay or it may be used to provide a timed intermission and then re-start. DO NOT SET CLOCK DIAL LOWER THAN 1 MINUTE ~ FOR SHOW START- Verify that the projector is properly threaded and the Fault light in stop button is OFF. Set clock to desired delay and press control switch S6 to the RIGHT (START). The indicator light in the clock will come on. As it times out, it will start the show. The clock may be stopped after it has been started by pressing the STOP BUTTON PB-2. If it is necessary to change the time setting, turn the clock OFF (PB-2) and then back ON (S6-START). DO NOT TURN THE DIAL ONCE THE CLOCK IS STARTED ~ To use the clock for a timed Intermission. Cue the show as called for in Show Make-up. Set Switch S6 to INTER. START position and SHOW END MODE switch SS to AUTO STOP. As the Automation cycles for the Intermission, the Clock will START and count down and restart the show. After the show has re-started, Switch SS should be set to NORMAL, so that the clock does not re-start at the end of the show.

Page 11 GENERAL- There are 2 kinds of relays used in the Kelmar Deluxe Automation. The small relays are 4 pole double throw 12 VAC and the large relays are 3 pole double throw 12 VAC. RELAYS ARE PLUG IN STYLE AND MAY BE INTERCHANGED. Designation Kl START RELAY 4PDT, LATCHES via. TM2~ Activated by Start Button or Interval Timer, Provides 120 VAC to timer motor, output to Latch K2 and K3 and 12 VAC to latch KS Hold relay. Drops out as TM2 opens. Will not activate with K6 activated (failsafe down) K2 START LATCH RELAY 4PDT, LATCHES via TM3, Activated by K1, energizes K7 ALARM Latch, Connects TM2 to Interlok plug, Connects TM4 to K11. Drops out as TM3 opens. K3 SHOW START RELAY 4PDT, LATCHES via TM3,- Activated by K1, Switches C.O. Pulse from TM5 to K14 or K15. Switches Stage and House light dimmer circuits for Show Start. Drops out as TM3 opens. K4 SHOW END RELAY 4PDT, LATCHES via TM3, Activated by OUTBOARD Cue Relay K17 via 55. Provides 120 VAC to timer motor, switches stage and house light dimmer circuits to Show End. Drops out as TM3 opens. K5 HOLD RELAY 4PDT, LATCHES via K6, Activated by K1, stays latched until K6 activates, Opens Non-Sync Circuit when latched, provides 12 VAC to POWER relay K12, and K9, K10 and term. 8 K6 FAILSAFE RELAY 4PDT, Activated by Failsafe Micro Switch or Stop button. Drops out KS, provides 12 VAC to Fault light, switches ground to Auto Intermission Circuit. K7 ALARM RELAY 4PDT, LATCHES via K11. Activated by K1, switches fault voltage to Alarm circuit, disconnects Interval Timer, connects Auto Inter. Circuit. Drops out when K11 opens or PB3 is pressed. KB AUTO STOP RELAY 4PDT, LATCHES via TM3. Activated by OUTBOARD Cue Relay K17 via 55. Energizes K4, provides 120 VAC to Interval Timer, connects Auto Stop circuit from K11 to K6. Drops out as TM3 opens. K9 CROSS CUE RELAY 4PDT, MOMENTARY, Activated by CROSS CUE, (term. 51) provides switching logic to Pre-Select switches S1 and S3. Provides Dimmer Output to terminal 41, latches K19 relay. Will only activate with KS latched. K10 INBOARD CUE RELAY 4PDT, MOMENTARY, Activated by INBOARD CUE, (term. 2) provides Dimmer output to terminal 42. Will only activate with KS latched. TM Relates to the timer module. The numerical designator is the deck in sequence from the drive end. K11 C.O. CLOSE LOGIC RELAY 4PDT, MOMENTARY, Activated by TM5 via K3 or TM4 via K2, or terminal 6. Provides Hold for; Interlok (term 12), Alarm Relay K7, and Exciter Relay K13. Provides Auto Stop logic to K8. K12 POWER RELAY 3PDT LATCHES activated when KS latched. Switches Motor (term. 29,30) and Lamp (term. 31,32) Activated as long as KS latched. K13 EXCITER RELAY 3PDT LATCHES via K11, Switches Exciter (term.37, 38) and Screen Projector (term. 47, 48). Activated by K14,drops out when K11 opens.

Page 12 Designation continued K14 C.O. OPEN RELAY 3PDT MOMENTARY, activated by TM5 via. K3. Provides C.O. Open, logic to K13, and provides a MONO audio pulse (term. 22) K15 C.O. CLOSE RELAY 3PDT MOMENTARY, activated by TM5 via K3 or TM4 via K2, or terminal 6. Provides C.O. Close (term. 3S), C.O. N.C. (term. 36), NON-SYNC (term. 24), and AUTO FLAT to board switch S1. K16 DIMMER OPTION RELAY 4PDT (OPTIONAL) K17 OUTBOARD CUE RELAY 4PDT MOMENTARY, Activated by OUTBOARD Cue, provides cue logic to SS, and Curtain Close (term. S6) K18 CURTAIN OPEN RELAY 4PDT MOMENTARY, Activated by TM5 via K3, provides Curtain Open logic (term. SS) K19 FEATURE LATCH RELAY 4PDT LATCHES via K9, provides logic to PL-l feature L.E.D. Stays latched until K5 opens. Will not activate unless K5 is latched.

Page 13 CINEMECCANICA V-5 FUNCTION KELMAR SERIES II TERM. No. TERM No. 4MOTOR 29 5 MOTOR 30 7 C.O. FEED 33 8 C.O. CLOSE 35 9 C.O. OPEN 34 14EXCITER 37 15 EXCITER 38 30 XENON LAMP 31 31 XENON LAMP 32 36 TURRET 16 37 TURRET 18* CINEMECCANICA V-8 FUNCTION KELMAR SERIES II TERM. No. TERM No. 4MOTOR 29 5 MOTOR 30 7 C.O. FEED 33 9 C.O. CLOSE 35 10 C.O. OPEN 34 15 EXCITER 37 16 EXCITER 38 30 XENON LAMP 31 31 XENON LAMP 32 36 TURRET 16 37 TURRET 18* * FOR LENS CHANGE, SET SERIES II SELECTOR SWITCH TO TURRET IS NOT ADDRESSABLE. THERE IS NO AUTO/FLAT

P3 P3 7 14 6 8 10 5 3 12 13 16 9 15 1 4 11 2 9 6 10 5 3 11 8 1 12 2 13 7 4 14 M S16 RE-START MONO S1 AUDIO S2 POWER P1 SYNC F1 3A. IN P7-3 P7-4 ST G PL1 S3 PB1 PB2 G B R FL LENS/MASK SC START STOP B S4 CROSS PB3 INBD CANCEL S5 MAN.CUE STOP MODE NORM IN P7-7 P7-5 OUT P7-8 P7-6 OPTION OMRON 9 10 A P2 3 4 1 2 5 P7 4 3 2 12 1 ST P2 S7 S8 MOTOR C.O. 6 8 1 1513 2 1610 9 12 11 3 7 P5 O C FL S9 LENS/ AC FEED MOTOR LAMP CHANGEOVER EXC. HOUSE DIMMER STAGE SCRN. N.S. 1 2 3 4 5 6 7 8 9 10 1 12 13 14 15 16 17 18 19 20 21 22 23 24 25 CUE DET. REM OTE LENS/MSK N.S. AUDIO SW. MASK SC S10 LAMP S11 U D S13 EXCITER S14 S15 3 9 12 1316 5 14 6 10 8 1 2 11 4 15 7 SERIES II CHASSIS SCHEMATIC Date: Scale: Drawn by: 4-10-01 1:1 T.A. Mohr D U ON SCRN PROJ AUTO G 6 4 3 Systems, Inc. 284 Broadway Huntington Station, NY 1174 631-421-1230 Rev: A N 1 P8 STATUS DWG.# XXXX Page 14 OUTBD. 1 2 3 4 5 6 7 INBD. FAILSAFE GROUND START C.O. CLOSE STOP RUN PL STOP PL FAULT PL ALARM I/L HOLD 12 VAC GROUND TM-4 FEED FLAT SCOPE LINE 120V NEUT. FEED MONO STEREO NON-SYNC P4 14 7 8 15 9 16 1 2 11 5 121310 6 4 3 P4 P5 LINE 120V NEUT GROUND 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 2 1 HOUSE STAGE P6 P6

K1 1 2 3 4 5 6 7 8 9 1011 12 13141516 1 2 3 4 5 6 7 8 91011 12 13141516 1 2 3 4 5 6 7 8 9 10 11 12 13 141516 1 2 3 4 5 6 7 8 9 10 11 12 13 1415 16 RELAY KEY 1 2 3 4 5 6 7 8 9 10 11 12 4PDT 1 2 3 4 5 6 7 8 9 A B 3PDT LEGEND 120 VAC 12 VAC GROUND WIRE HOLE CONNECTION 1 P2 6 RELAY LEGEND K1- START K2- START LATCH K3- SHOW START K4- SHOW END K5- HOLD K6- FAILSAFE K7- ALARM K8- AUTO. STOP K9- CROSS CUE K10- INBOARD CUE K11- C.O. CLOSE LOGIC K14- C.O. OPEN K15- C.O. CLOSE K16- DIMMER OPTION K17- OUTBOARD CUE K18- CURTAIN OPEN K19- FEATURE LATCH K15 7864 AUTOMATION LOGIC BOARD Auto FLAT For Series II,III, AM-7,8 Automations Date: Scale: Drawn by: 4-28-00 NONE T.A. Mohr S1 Systems, Inc. 284 Broadway Huntington Station, NY 1174 631-421-1230 Rev: A Page 15 K2 K3 K4 K5 K6 K7 K8 K9 K10 K11 K16 K17 K18 K19 K14 P3 P4 P5 P6 13 14

KELMAR PART# PC7864 AUTOMATION LOGIC BOARD K1 K2 K3 K4 K5 K6 P3 K7 K8 K9 K10 K11 K16 K17 K18 K19 K14 K15 P3 P4 P5 P6 TO ELEMINATE THE AUTO-FLAT COMMAND DURING CHANGEOVER CLOSE CUT THIS STRAP S1 Page 16