Detect Color and Shape for various inspection

Similar documents
F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

SERIES. Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button.

Electrical connection

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Electrical connection

Photoelectric Sensors E3F2

Basic Information Before Use. Display on LCD Screen. Distinction by. Patterns Recognition. Use of Applied Functions. Changing Set Value

Electrical connection

Progressive Scan CCD Color Camera KP-FD30M. Specifications ( Revision.1 )

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

Type F70AB F70ABPN. Digital display. Simple operation featured

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

YSC -HD-AK1 HDMI / HD-SDI

Vision Sensor Short Manual

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Electrical connection

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

Operating instructions Electronic preset counter Type series 717

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Safety Light Curtain Type4 SIL3 PLe

Absolute Rotary Encoder E6CP

Operating Instructions

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

SERIES 400 SERIES 620

CDX series. World s No. 1 Linearity OPTEX FA CO., LTD. New models added. Ultra High-Accuracy Laser Displacement Sensor

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

EZ Encoder : Optical Incremental (P Series)

True Color Sensor with Analog and Digital Outputs

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

Pressure Sensor. PSAN Series. Compact Digital Pressure Sensors. Features Pressure Measurement Range (Negative, Standard, Compound)

Standard RS232 RS ma

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

Cylindrical Photoelectric Sensor CY-100 SERIES

Material: Weight: IP Rating: Cable: Connector:

SPACESCAN SERIES SS 02

L-LAS Series L-LAS-LT-50-SL-... Design. L-LAS Series Laser Line Sensors. Product name:

Automatic Camera Tracking System

Broadcast A/V Division M-LYNX-702 V.3. Dual 7 LCD Display. User Manual

Broadcast A / V Division M-LYNX-702 V.3. Dual 7 LCD Display. User Manual

Multifunction devices

Smart-Encoder : Optical Incremental

L-LAS Series L-LAS-LT-2500-XL. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-2500-XL

Hour Meters / Timers, electronic

DH5e-V2. Delta 5 On-Camera 4K HDMI Monitor with 3D LUTs. Quick Start Guide. What s Included

DIGITAL PANEL METER DISPLAY FOR 15mm MOSAIC - LPDSA SERIES

VTC-BHOCR MP HD-SDI Vandal Resistant WDR Bullet Camera with mm & 70 IR LEDs VITEK

SA1J-F: Full Color Fiber Optic Sensors

F70series. Variation. Excellent detection performance

RACKMOUNT 7'' 3G-SDI DUAL LCD MONITORS USER MANUAL UMEN V1.0

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

NEXT/RADIUS Shelf Mount CCU

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

SENSORS S60. Compact Sensors - S60. Extended range of standard One for All photoelectric compact sensors

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

Quad Picture Display (one big window with three small windows), press this button again to change 4 video sequence.

43 Professional Monitors

PIXEL TOUCH PCB KEEP THIS MANUAL FOR FUTURE NEEDS

Electrical connection

Digital Flow Switch for Large Flow

User Guide

SPECTRO Series. SPECTRO-1-30-UV/VIS-9x1. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

SPECTRO Series SPECTRO-1-30-UV/UV. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Analogue HD Monitoring Set: 8-Channel Video Recorder + 4 Outdoor Cameras

RLS Series RLS-GD-20/20 -UV. Design. RLS-GD Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

VISION. Data VS2 DATAVS2. Phone: Fax: Web:

Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button. Teaching button

Amplifier for fiber optics. Dimensioned drawing

Electronic Pulse Counter Combination device

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Safety Light Curtains GuardShield

Q3X Laser Contrast Sensor

SU17 Series Fiber Optic Sensors

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

Marshall Electronics. Pro A/V Communications VMV-402-SH. 3G/HD/SD-SDI Quad-viewer/Switcher with Audio Meter Display. User Manual.

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

SPECTRO Series SPECTRO-1-50-DIL. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

HDMI 4 input 1 output Quad/Multi-viewer & Seamless Switcher. ITEM NO.: HM41E 4 x 1 HDMI Multiviewer & Seamless Switcher

HITACHI. Instruction Manual VL-21A

EVENT INPUT/OUTPUT MODULE [PUME]

02/11/2015

DH5e QUICKSTART GUIDE. 5" 4K Support HDMI On-Camera Field Monitor w/ Touch Screen

FCB-H10-FG HD-SDI/Analog

SIMATRIX NEO V2 Modular Video Matrix

Transcription:

CVS2-RA SERIES MVS Series APPLICATI CVSE1-RA CVS1-RA CVS2-RA CVS3-RA CVS-R OPTIS Wide range line-up CVS2-N20-RA Standard type CVS2-N10-RA Long range type CVS2-N0-RA Macro view type CVS2-N21-RA Narrow view type Correct background brightness CVS2-RA has a function that corrects evenness of background brightness. You register just the background for reference. Up to 15 Bank 15 Banks are available in small all in one package. Detect Color and Shape for various inspection - All in one color vision sensor - For Pattern matching and Color inspection - Better sensitivity by Masking function Pattern matching mode and Color inspection mode are available Inspection of shape and direction of the object is available by pattern matching mode. You can use CVS2-RA as simple Color inspection sensor as well. Sorting by color is also available. Captured image Registered image All in one Comparing its shape Pattern matching mode Color inspection mode O K Check size of area The sensor has a built-in Camera, LED Lighting, Display monitor and Controller. This structure enables water resistance IP67. Camera Lighting Monitor Controller Orange/Black Yellow/Black LCD display Pink Purple Red/Black Blue NPN Type Processor 0V N G Lighting Lens Image sensor Wide coverage line-up You can choose from inspection range/field of view according to inspection target condition.

Pattern Matching mode CVS2-RA detects up to 65,536 colors and checks its shape to compare with registered image. Captured image Comparing its shape Registered image Color Inspection mode Determine when the area that the color matches exceeds the threshold. O K N G Determine when the area that the color matches is in two thresholds. N G O K N G Two Color Inspection at a time CVS2-RA can inspect two colors for one application at a time. Checking Two Color Masking function Sorting function You can set Upper and Lower threshold for two colors to inspect. You can choose a logic from combination. Two bar graphs for two colors Two threshold for two colors each You can mask the area you don't want to detect the color freely in position. Blue part is masked area Sorting is available by utilizing two outputs up to 3. You can also increase the sorting number up to 15 by utilizing RS-232C controlling. When this parameter is 1, you can sort in two criteria. 5

MVS Series APPLICATI Features Masking function You can mask the area that doesn't have to be checked so that you can get better sensitivity of color inspection. Downloading setup parameters to PC You can download setup data and image data into PC. You can use the image data on PC and can copy setup to other CVS2-RA. Please use I/F cable CVS-C2C. Zoom function CVS2-RA has Zoom function so you can zoom in up to twice size. Masking area CVSE1-RA CVS1-RA CVS2-RA CVS3-RA CVS-R OPTIS Setup Adjustable while line is running CVS2-R provides output with the setup parameters given even while you are adjusting setup. You don't have to stop the line. Correct background brightness CVS2-RA has a function that corrects evenness of background brightness. You register just the background for reference. Vision processor Read/Write CPU for controlling CVS2-RA has two processing unit individually so it can change parameters while vision processing is running without delay. Before correction x 2 After correction 6

Masking You can mask the area that doesn't have to be checked so that you can get better sensitivity of color inspection. Setup You can setup the area to mask as follows. a b Move the cursor on the color you want to mask or not to mask. You can set the area of cursor as mask area. Mask area turns to purple. Then, you can add the area or remove from the area to mask. You also magnify or shrink the area easily. a + b You can set the area "a" and "b" combined easily. Color inspect area Area to detect the color You can limit the area to inspect color from. This prevents miss-detection of color at the edge of the FOV. Area to be neglected Standard screen Limit the area to detect Example of masking Example 1 Example 3 Wrong direction Lack Direction Lack Example 2 Example Positioning Displacement Disposition Leaning You can get better result by masking the area that doesn't show characteristics of the target object. 7

MVS Series APPLICATI Display 2 3 Pattern matching mode 7 Response time Shows response time. Unit : 0.1ms. Example : 266 = 26.6ms Switches Specifications 1 5 6 7 8 1 Captured image Image captured by the camera Shows parameters 3 Display mode UP 2 Parameters You can change display mode by VIEW button Bar graph Shows how big the area that the color matches. Threshold is at the border of green and orange. 5 Bank No. Shows current Bank. 6 Auxiliary output Status of auxiliary output. means 8 Color match area Shows area that color matches. Orange :, Green : Move cursor up and increase parameter value DOWN Move cursor down and decrease parameter value 2 3 8 CVS1 compatible mode When sorting is active VIEW Change the display mode F: Dark Compensated image EXIT 2: Shows only chosen color area D: Shows original image Use this button when you quit changing parameter and going back to previous menu. SET Change to setup mode. Choose the parameter by pressing 3 sec. or more. 1 5 6 7 7 1 Captured image Image captured by the camera 2 Parameters Shows parameters 3 Display mode Shows display mode Display mode Shows how big the area that the color matches. 5 Registered color Min. Center and Max. color 6 Bank No. Shows current Bank. 7 Output/Sorting status Orange:, Green: Shows sorting No. when it's active. 8 Monitoring Bank No. Shows Bank No. for sorting. CVSE1-RA CVS1-RA CVS2-RA CVS3-RA CVS-R OPTIS Model Detection angle Field of view Light source Image sensor Supply Voltage Power consumption Resolution LED light duration Response Pattern matching mode time CVS1 compatible mode Output Input Operating temperature Operating humidity Storage temperature/humidity Vibration/shock resistance Material Protection structure Weight CVS2-N10-RA CVS2-P10-RA 10 210 to 270mm 0 x 50mm to 55 x 65mm White LED 12 pcs built-in CVS2-N20-RA CVS2-P20-RA 20 90 to 150mm 0 x 50mm to 65 x 75mm CVS2-N21-RA CVS2-P21-RA 31 to 39mm 17 x 20mm (±10%) CVS2-N0-RA CVS2-P0-RA 0 50 to 100mm 50 x 65mm to 100 x 115mm 330,000 Pixel CMOS color image sensor 12 to 2V DC±10% Max. 10mA/2V DC 8 x16 to 200 x 20 Approx.50,000 hours(in normal temperature and humidity. Brightness level down by 1/3 of the initial level) 9.2/15.2/21.2/27.3ms (Standerd mode) 6.7/10.9/15.2/19.5ms (Double speed mode) 8.7/1.8/20.8/26.8ms (Standerd mode) 5.7/9.7/13.5/17.3ms (Double speed mode) NPN or PNP open collector output x 2 max. 100mA Residual voltage 1.0V or less Bank select 0 to 1, Bank select 2 (switchable to Teach input), Bank select 3 (switchable to Sync input), Teach in (switchable to Bank select 3 or Auxiliary output) 0 to 0 (No condensation) 35 to 85%RH -20 to 70, 35 to 95%RH(No condensation) 10 to 55Hz Amplitude 1.5mm / 50G(500m/s 2 ) Case:ABS / Display and Lens : Acryl or Polycarbonate IP67 Approx.200g (including cable) 8

Connection diagram (NPN) (PNP) Photo coupler 7.5k 15k 12-2VDC (Brown) Bank select 0 (Orange/Black) Bank select 1 (Yellow/Black) Bank select 2/Teach in (Pink) Bank select 3/Sync input (Purple) Photo coupler 7.5k 15k 0V (Blue) Bank select 0 (Orange/Black) Bank select 1 (Yellow/Black) Bank select 2/Teach in (Pink) Bank select 3/Sync input (Purple) Protection diode Teach in/bank select 3/ Auxiliary output (Red/Black) Protection diode Teach in/bank select 3/ Auxiliary output (Red/Black) Output (Black) 0V (Blue) Output (Black) 12-2VDC (Brown) Auxiliary output Bank table AUX OUT=0: Ready - Turns after switching Bank. Turns when Output is ready AUX OUT=1: Judge timing - Turns when Judge timing AUX OUT=2: Light timing - Turns when Lighting AUX OUT=3: Searching result - Turns when each search result is in its criteria, MAGNIFY%, POSIT% X, POSIT% Y, ROTATE%. Set up External Input BANK SYNCHR Bank select 0 Bank select 1 Bank select 2 Bank select 3 Sorting output You can get sorting output from following table that shows which bank matches by combination of Output (Black) and Auxiliary output (Red/Black) signals. Bank No. Current Bank +1 +2 Field of View CVS2-N10-RA Long range type 0~1 15 16 0~3 0~3 0~3 NA NA Active Active External Teach-in Active NA Synch.In Active Synch.In Active Synch.In Output(Black) Auxiliary output(red/black) Bank No. Bank select input 3(Purple) 2(Pink) 1(Yellow/Black) 0(Orange/Black) 0 1 2 3 5 6 7 8 9 10 11 12 13 1 CVS2-N0-RA Macro view type NPN: OPEN or connect with the brown line. PNP: OPEN or connect with the blue line. NPN: connect with the blue line. PNP: connect with the brown line. CVS2-N20-RA Standard type 210mm 270mm 0 50mm 55 65mm CVS2-N21-RA Narrow view type 50mm 100mm 50 65mm 100 115mm 35mm 17 20mm 90mm 150mm 0 50mm 65 75mm * Input/Output selectable by setup 9

MVS Series APPLICATI CVS3-RA CVSE1-RA CVS1-RA CVS2-RA CVS3-RA CVS-R OPTIS Dimensions Cable for I/F and Power supply Remote monitor CVS-M1-R Cable for I/F and Power supply 2 13.2 15.5 Tips for mounting CVS series 2 95 11 I/F connector 11.2 95 11 87 Fastening torque: 0.8N*m Max. 87 Fastening torque: 0.8N*m Max. - Please determine and Field of View so that you choose correct model number of CVS series. - Please use M * 50mm screws to mount CVS series - Please take care about distance between CVS and target object to get stable size of Field of View. - Please mount CVS at 15 to 5 degree to prevent specular reflection from the object especially from glossy object. - When the object moves fast, you have to set shutter speed shorter. Then, you will need brighter lighting to get better image. Please try external lighting in this case..2.2 33.8 33.8 28.2 21 Cable (2m) 5mm 8 core x 0.08mm 2 (CVS1: 7 core) Cable (300mm) 5mm 15 ~ 5 (unit: mm) 60