Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector

Similar documents
An extreme high resolution Timing Counter for the MEG Upgrade

TORCH a large-area detector for high resolution time-of-flight

A new Scintillating Fibre Tracker for LHCb experiment

SciFi A Large Scintillating Fibre Tracker for LHCb

HAPD and Electronics Updates

The hybrid photon detectors for the LHCb-RICH counters

The Scintillating Fibre Tracker for the LHCb Upgrade. DESY Joint Instrumentation Seminar

Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment

Status of the CUORE Electronics and the LHCb RICH Upgrade photodetector chain

Performance of the MCP-PMT for the Belle II TOP counter

The Silicon Pixel Detector (SPD) for the ALICE Experiment

THE TIMING COUNTER OF THE MEG EXPERIMENT: DESIGN AND COMMISSIONING (OR HOW TO BUILD YOUR OWN HIGH TIMING RESOLUTION DETECTOR )

Solid State Photon-Counters

Studies of large dynamic range silicon photomultipliers for the CMS HCAL upgrade

Large Area, High Speed Photo-detectors Readout

Liquid Xenon Scintillation Detector with UV-SiPM Readout for MEG Upgrade

Commissioning and Initial Performance of the Belle II itop PID Subdetector

A TARGET-based camera for CTA

CAEN Tools for Discovery

Commissioning and Performance of the ATLAS Transition Radiation Tracker with High Energy Collisions at LHC

Spatial Response of Photon Detectors used in the Focusing DIRC prototype

A pixel chip for tracking in ALICE and particle identification in LHCb

Prospect and Plan for IRS3B Readout

A fast and precise COME & KISS* QDC and TDC for diamond detectors and further applications

Sensors for precision timing HEP

The Alice Silicon Pixel Detector (SPD) Peter Chochula for the Alice Pixel Collaboration

Investigation of time-of-flight PET detectors with depth encoding

Updates on the Central TOF System for the CLAS12 detector

Production and Development status of MPPC

Silicon PhotoMultiplier Kits

The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications

Report from the 2015 AHCAL beam test at the SPS. Katja Krüger CALICE Collaboration Meeting MPP Munich 10 September 2015

Sensors for the CMS High Granularity Calorimeter

New gas detectors for the PRISMA spectrometer focal plane

A flexible FPGA based QDC and TDC for the HADES and the CBM calorimeters TWEPP 2016, Karlsruhe HADES CBM

Status of the Timing Detector Plastic+SiPM Readout Option

Atlas Pixel Replacement/Upgrade. Measurements on 3D sensors

Tests of Timing Properties of Silicon Photomultipliers

Frontend Electronics for high-precision single photo-electron timing

PoS(PhotoDet 2012)018

with Low Cost and Low Material Budget

Study of Timing and Efficiency Properties of Multi-Anode Photomultipliers

Quick Report on Silicon G-APDs (a.k.a. Si-PM) studies. XIV SuperB General Meeting LNF - Frascati

PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND. Doug Roberts U of Maryland, College Park

Imaging diagnostico in Sanità Stato attuale e prospettive

arxiv: v1 [physics.ins-det] 1 Nov 2015

Local Trigger Electronics for the CMS Drift Tubes Muon Detector

Single Photoelectron timing resolution of SiPM

PMT Gain & Resolution Measurements in High Magnetic Fields

SuperB- DCH. Servizio Ele<ronico Laboratori FrascaA

PicoScope 6407 Digitizer

PIXEL2000, June 5-8, FRANCO MEDDI CERN-ALICE / University of Rome & INFN, Italy. For the ALICE Collaboration

Imaging TOP (itop), Cosmic Ray Test Stand & PID Readout Update

Development of Ultra-High-Density (UHD) Silicon Photomultipliers with improved Detection Efficiency

Diamond detectors in the CMS BCM1F

Front End Electronics

Time Resolution Improvement of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals

CMS Upgrade Activities

Antenna system Status & progress report

An extreme high resolution Timing Counter for the MEG experiment Upgrade

The ATLAS Tile Calorimeter, its performance with pp collisions and its upgrades for high luminosity LHC

The Time-of-Flight Detector for the ALICE experiment

PicoScope 6407 Digitizer

R&D on high performance RPC for the ATLAS Phase-II upgrade

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

Minutes of the ALICE Technical Board, November 14 th, The draft minutes of the October 2013 TF meeting were approved without any changes.

MCP Signal Extraction and Timing Studies. Kurtis Nishimura University of Hawaii LAPPD Collaboration Meeting June 11, 2010

Lifetime of MCP-PMTs

CGEM-IT project update

RX40_V1_0 Measurement Report F.Faccio

THE WaveDAQ SYSTEM FOR THE MEG II UPGRADE

Drift Tubes as Muon Detectors for ILC

Design and test of an extremely high resolution Timing Counter for the MEG II experiment: preliminary results

First evaluation of the prototype 19-modules camera for the Large Size Telescope of the CTA

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

The ATLAS Pixel Detector

Precision measurements of beam current, position and phase for an e+e- linear collider

Beam test of the QMB6 calibration board and HBU0 prototype

FRANCO MEDDI CERN-ALICE / University of Rome & INFN, Italy. For the ALICE Collaboration

Front End Electronics

arxiv:hep-ex/ v1 27 Nov 2003

THE ATLAS Inner Detector [2] is designed for precision

Concept and operation of the high resolution gaseous micro-pixel detector Gossip

Ethernet Media Converters

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

Large photocathode 20-inch PMT testing methods for the JUNO experiment

First LHC Beams in ATLAS. Peter Krieger University of Toronto On behalf of the ATLAS Collaboration

TitleLarge strip RPCs for the LEPS2 TOF. Author(s) Chu, M.-L.; Chang, W.-C.; Chen, J.- Equipment (2014), 766:

DPD80 Visible Datasheet

Current status of Hamamatsu Si detectors mainly for High Energy Physics Experiments

Photo Multipliers Tubes characterization for WA105 experiment. Chiara Lastoria TAE Benasque 07/09/2016

APD modules. Operates an APD with single 5 V supply (standard type, short-wavelength type) C12702 series.

Development of an Abort Gap Monitor for High-Energy Proton Rings *

DAQ Systems in Hall A

Progress on the development of a detector mounted analog and digital readout system

The Status of the ATLAS Inner Detector

In-process inspection: Inspector technology and concept

HARDROC, Readout chip of the Digital Hadronic Calorimeter of ILC

Advanced Test Equipment Rentals ATEC (2832)

DPD80 Infrared Datasheet

Transcription:

Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector William Nalti, Ken Suzuki, Stefan-Meyer-Institut, ÖAW on behalf of the PANDA/Barrel-TOF(SciTil) group 12.06.2018, ICASiPM2018 1

Outline Introduction: PANDA & FAIR Barrel TOF Design Single Tile Performance Larger Scale Integration Tomorrow 11.45: Application of SiPMs and MCP-PMTs in the PANDA PID detectors - Albert Lehmann (Erlangen University) 2

PANDA Experiment at FAIR MVD<STT<B-DIRC<B-TOF<EMC Installation planned end-2021, with physics starting 2025 3

Barrel Time-of-Flight (TOF) Design 2.46m long, 1m diameter 16 Super modules 240 ch. /SM max. 40 khz /ch. Covers 22.5 < θ < 140 180x18 cm 2 scintillators (120x) area 2 ch./scint. Scintillator Tile rest is left for FEE Total: 1920 tiles, 3840 channels, 15360 SiPMs

Capabilities and Requirements Collision time determination event sorting 20 MHz interaction rate hits in detector particle identification (PID) collisions Requirement: σt<100 ps to keep the efficiency loss due to event mixing in a tolerable level 5

Single Tile Design

Dual Module single-sided double-sided MMCX connector 7

Performance - single tile Optimization of time-resolution in terms of material, wrapping, threshold, overvoltage Very fine position dependence measurement of the performance with the optimised condition with well collimated 90 Sr source In collaboration with Erlangen 8

Performance - single tile HV 240V, threshold -30 mv, 2000 events/position, 3069 positions Mean time resolution σ = 53.9 ps 9

Performance single Tile Side view of the Sensorboard Surface coverage = 1/4 scintillator (28.5x5 mm 2 ) SiPM (3x3 mm 2 ) LED Temperature sensor 10

Barrel Timing Hodoscope, New Design.. SciTil proposal SciTil MEG2 Scintillator Tile Signal Transmission Line 30x30 90x30 120x40/50 σ~90 ps σ~90 ps ASIC 11

Micro Stripline Technique Coaxial-like structure to transmit signals over a PCB board, realised on a multilayer PCB board, that feature: High density Good shielding from external noise High bandwidth Low crosstalk Mechanical strength sidecut First prototype 2 GND per line

Crosstalk between the Micro Striplines (Prototype n 1) Tested in realistic condition. 1ns rise-time = 350 MHz Crosstalks can be reduced e.g. by using via and/or by optimizing the channel sequence 13

Probable Best Design single ground layer interconnected at the board ends lines shuffled to minimize the distance they share as direct neighbour design not tested yet, due to considerable manufacture delay. Delivered last week. This design = crosstalk reduction? Less copper as prototype 1 = material budget reduction. due to some spare space on the railboard and no extra cost, few other designs were added and will be tested for comparison

Front End Electronics 66cm allocated for FEE TOFPET2 ASIC readout TOFPET2 ASIC test board (64ch) Test assembly with SiPM and ASIC board SiPM + LYSO crystal

Summary Barrel Time-of-Flight Detector for PANDA 240cm long, 5m 2 sensitive area, 15.360 SiPM, 2.000 Tiles, 4.000 channels series connection of 4 SiPMs Cable-less design with transmission lines over PCB board σt~50 ps, lab test. Beam test, see talk Albert Lehman (tomorrow 11:45) Detector installation ~ 2022 16

Backup 17

Performance - single tile Time resolution depend of Pole Zero Cancelation PZC = 1200Ω 230V bias Reproduced in 2017: 63.2ps for 1200Ω and 53.4ps for 500Ω Bias voltage also has slight impact on time resolution Threshold scan: 11.3mV : 49,7 +/- 1,9 ps 20mV : 47.0 +/- 2.8 ps 40mV : 48.3 +/- 3.4 ps 50mV : 50.3 +/- 5.0 ps 75mV : 50.3 +/- 3.4 ps Best time-resolution for 20mV threshold PZC = 500Ω 230V bias PZC = 500Ω 240V bias 18

Capabilities and Requirements, and Detector Layout between the Barrel DIRC and the EMC SciTil DIRC high efficiency to charged particles blind to γs 19

Super Module - a half length prototype

Large PCB (railboard) production issue & Delivery Delay (3.5 months late) 2400 660 1800 660-X 1800+X D A 900 900 Half-length was not a problem. Full length is. Production at CERN? 21

Monitoring and Calibration Voltage and current monitoring the primary parameter that influences the characteristics of SiPM general health check Temperature SMD PTC on the sensor-board relative: 200 mk, absolute: 4 K Gain DCR: 10-100 khz/mm 2 LED calibration system SMD LED on the sensor-board

SciRod (Erlangen) cont d 23

The best time precision when triggering on the first photon? Analog SiPM Time resolution of a scintillator tile read-out with the Hamamatsu SiPMs No, the trigger threshold should not be set to the first detected photon, due to electronics noise and the SPTR of the SiPM. 24

The best time precision when triggering on the first photon? Analog SiPM analog SiPMs, this behaviour is changed due to electronics noise and the SPTR Time resolution of a scintillator tile read-out with the Hamamatsu SiPMs No, the trigger threshold should not be set to the first detected photon 25

SPTR of SiPMs 2 options: Hamamatsu or Ketek (3x3 mm2) AdvanSiD: worse timing, low PDE SPTR SensL: also lower PDE Ketek with optical trenches showed best results Time resolution follows 1/ N We expect ~ 60 photons per SiPM: Hamamatsu 100P σ ~ 40 ps KETEK PM3350 σ ~ 25 ps Time resolution below 100 ps for the SciTil detector of PANDA employing SiPM S.E. Brunner, L. Gruber, J. Marton, H. Orth, K. Suzuki with picosecond pulsed laser (400 nm) 26

Micro Stripline Technique Coaxial-like structure to transmit signals over a PCB board, realised on a multilayer PCB board, that features High density Good shielding from external noise High bandwidth Low crosstalk Mechanical strength

Complementary Designs Railboard v2.

Rate Capability Max. tile hit rate 29

Signal Attenuation on the Micro Striplines ation can be reduced by increasing the cross section of the signal m 30

Crosstalks between Micro Striplines 1 ns rise time 3.9 % 1.4 % Crosstalks can be reduced e.g. by using via and/or by optimising the ch. sequence 1 6 11 16 21 26 2 7 12 17 22 27 3 8 13 18 23 28 4 9 14 19 24 29 5 10 15 20 253130

Efficiency design A design B 100 MHz assumed Sensor recovery time: ~50 ns, TOF-PET chip >300 khz average through-put, Max tile hit-rate is ~40 khz, TOF-PET chip has a buffer (4 hits) to cope with locally high-rate events 32

TOF-based Particle Identification from simulation 33

Relative TOF 34

Relative TOF 37

Radiation Hardness of SiPMs 38

Radiation Hardness of SiPMs 39

Radiation Hardness of SiPMs 40

Radiation Hardness of Scintillator Material Expected dose ~8.4 krad 41

Front End Electronics, DCS 42

Monitoring and Calibration Voltage and current monitoring the primary parameter that influences the characteristics of SiPM general health check Temperature SMD PTC on the sensor-board relative: 200 mk, absolute: 4 K Gain DCR: 10-100 khz/mm 2 LED calibration system? SMD LED on the sensor-board