Brain Activities supporting Finger Operations, analyzed by Neuro-NIRS,

Similar documents
Investigation of Digital Signal Processing of High-speed DACs Signals for Settling Time Testing

Finger motion in piano performance: Touch and tempo

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

Tutorial 3 Normalize step-cycles, average waveform amplitude and the Layout program

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Lab experience 1: Introduction to LabView

Measurement of overtone frequencies of a toy piano and perception of its pitch

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0

Robert Alexandru Dobre, Cristian Negrescu

Vascular. Development of Trinias FPD-Equipped Angiography System. 1. Introduction. MEDICAL NOW No.73 (2013.2) Yoshiaki Miura

The Measurement Tools and What They Do

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

"shell" digital storage oscilloscope (Beta)

Zero Crossover Dynamic Power Synchronization Technology Overview

Study of White Gaussian Noise with Varying Signal to Noise Ratio in Speech Signal using Wavelet

Iterative Direct DPD White Paper

Department of Electrical & Electronic Engineering Imperial College of Science, Technology and Medicine. Project: Real-Time Speech Enhancement

Signal Stability Analyser

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5

Experiment 13 Sampling and reconstruction

D-Lab & D-Lab Control Plan. Measure. Analyse. User Manual

LA-1440 and LA-4440 Sound Level Meter

Precision testing methods of Event Timer A032-ET

For the SIA. Applications of Propagation Delay & Skew tool. Introduction. Theory of Operation. Propagation Delay & Skew Tool

Pole Zero Correction using OBSPY and PSN Data

Getting started with Spike Recorder on PC/Mac/Linux

BioGraph Infiniti Physiology Suite

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1

Inter-Player Variability of a Roll Performance on a Snare-Drum Performance

Patchmaster. Elektronik. The Pulse generator. February 2013

Application Note 11 - Totalization

Good playing practice when drumming: Influence of tempo on timing and preparatory movements for healthy and dystonic players

technical note flicker measurement display & lighting measurement

ECE 4220 Real Time Embedded Systems Final Project Spectrum Analyzer

BER MEASUREMENT IN THE NOISY CHANNEL

1 Ver.mob Brief guide

Analysis of AP/axon classes and PSP on the basis of AP amplitude

Analog Discovery Scope and Waveform Generator Edited 11/15/2016 by Eric Scotti & DGH

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Pitch correction on the human voice

MindMouse. This project is written in C++ and uses the following Libraries: LibSvm, kissfft, BOOST File System, and Emotiv Research Edition SDK.

Using an Expressive Performance Template in a Music Conducting Interface

LeCroy Digital Oscilloscopes

A HIGHLY INTERACTIVE SYSTEM FOR PROCESSING LARGE VOLUMES OF ULTRASONIC TESTING DATA. H. L. Grothues, R. H. Peterson, D. R. Hamlin, K. s.

4.9 BEAM BLANKING AND PULSING OPTIONS

The BAT WAVE ANALYZER project

T ips in measuring and reducing monitor jitter

ECG SIGNAL COMPRESSION BASED ON FRACTALS AND RLE

Doubletalk Detection

What is Statistics? 13.1 What is Statistics? Statistics

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Digital Storage Oscilloscopes 2550 Series

Rec. ITU-R BT RECOMMENDATION ITU-R BT * WIDE-SCREEN SIGNALLING FOR BROADCASTING

USB Mini Spectrum Analyzer User s Guide TSA5G35

Detection and demodulation of non-cooperative burst signal Feng Yue 1, Wu Guangzhi 1, Tao Min 1

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

HITACHI. Instruction Manual VL-21A

Specification of interfaces for 625 line digital PAL signals CONTENTS

Removing the Pattern Noise from all STIS Side-2 CCD data

Advanced Test Equipment Rentals ATEC (2832)

Lesson 1 EMG 1 Electromyography: Motor Unit Recruitment

Thought Technology Ltd Belgrave Avenue, Montreal, QC H4A 2L8 Canada

PulseCounter Neutron & Gamma Spectrometry Software Manual

The Cathode Ray Tube

Towards Culturally-Situated Agent Which Can Detect Cultural Differences

STAT 113: Statistics and Society Ellen Gundlach, Purdue University. (Chapters refer to Moore and Notz, Statistics: Concepts and Controversies, 8e)

m RSC Chromatographie Integration Methods Second Edition CHROMATOGRAPHY MONOGRAPHS Norman Dyson Dyson Instruments Ltd., UK

DDA-UG-E Rev E ISSUED: December 1999 ²

Receiver Testing to Third Generation Standards. Jim Dunford, October 2011

K-BUS Dimmer Module User manual-ver. 1

Audio Compression Technology for Voice Transmission

Agilent DSO5014A Oscilloscope Tutorial

Getting Started with the LabVIEW Sound and Vibration Toolkit

Algebra I Module 2 Lessons 1 19

ORTHOGONAL frequency division multiplexing

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

Pattern Based Attendance System using RF module

KNX 1-10V dimmer 4 channels

Vocoder Reference Test TELECOMMUNICATIONS INDUSTRY ASSOCIATION

Improved Synchronization System for Thermal Power Station

Spectrum Analyser Basics

Brain-Computer Interface (BCI)

Development of an Abort Gap Monitor for High-Energy Proton Rings *

Experiment P32: Sound Waves (Sound Sensor)

E X P E R I M E N T 1

Understanding the Limitations of Replaying Relay-Created COMTRADE Event Files Through Microprocessor-Based Relays

iworx Sample Lab Experiment AM-9: Crayfish Gut Pharmacology

Standard Operating Procedure of nanoir2-s

PHYSICS OF MUSIC. 1.) Charles Taylor, Exploring Music (Music Library ML3805 T )

Type-2 Fuzzy Logic Sensor Fusion for Fire Detection Robots

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

Colour Reproduction Performance of JPEG and JPEG2000 Codecs

Subjective evaluation of common singing skills using the rank ordering method

Short Manual. ZX2 Short Manual.doc Page 1 of 12

Real-time QC in HCHP seismic acquisition Ning Hongxiao, Wei Guowei and Wang Qiucheng, BGP, CNPC

Practice makes less imperfect: the effects of experience and practice on the kinetics and coordination of flutists' fingers

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

INTEGRATED CIRCUITS DATA SHEET. TDA4510 PAL decoder. Product specification File under Integrated Circuits, IC02

Operating Instructions

Transcription:

Brain Activities supporting Finger Operations, analyzed by euro-irs, Miki FUCHIGAMI 1, Akira OKAA 1, Hiroshi TAMURA 2 1 Osaka City University, Sugimotocho, Osaka City, Japan 2 Institute for HUMA ITERFACE, C1803 Portpia plaza, 6-14 Minatojima nakamachi, Chuoku, Kobe City, JAPA 650-0046 (tamura@mobilergo.com) Abstract. Brain activities are analyzed for the button selection task using euro-irs, which is analysis method of quick component of IRS. Quick component of IRS is numerically quantifies by short time average of absolute value. The average is represented by, maximum and density. Since button selection task is short time event, it seems the instantaneous activities, like maximum is playing major roles in finger selection to operate button. Keywords: neural activities, IRS, quick components, finger selection, button operation 1 Introduction Working brain needs more oxygen supply. Thus hemodynamic studies expect the areas supplied with rich oxygen are tentatively working. But this is only an expectation, but no evidence. We have to find evidences related to parts of the brain actually functioning. Hemodynamic studies are interested in slow components of IRS, especially oxyhb. People engaged in hemodynamics, however have realized the existence of quick signal while recording IRS. So far the signal is regarded as noise, and skill of IRS measurement is to find the location where the noise can be minimized. So called noise is so large to be regarded as measurement noise, it must be substantial physiological signal, which we named quick component of IRS. Attempts have been made to analyze the signal and to make the model of the signal source [5]. Evidence are convincing that the quick component is result of neural activities under recording and successful results are promising in relation to daily human activities, like hand up/down, finger sign, and text entry, etc., to which hemodynamic studies are powerless. Hemodynamic and neural functions are both significant aspects of brain studies. Cerebral infarction might cause hemodynamic problems, which might result in neural dysfunctions. Rehabilitation is the process of recovering hemodynamics and neural function. euro-irs is a new significant aspect of IRS studies.

Analysis of button operation by IRS. 2 Quick components 2.1 IRS coordinates Fig. 1 is showing Oxy, eoxy, and Total Hb ( hemoglobin) recording of 6 channels from IRS. The upper trace corresponds to oxy, the middle to total, and the lower to deoxy Hb. The channel number is indicated at the middle of the left side of each chart. Looking to the channel 26, oxy and deoxy Hb contains big high frequency components, which we call quick components, the total Hb contains less. The traces of 29 and 32 contain less quick components, in both oxy and deoxy, as well as total Hb. ynamics of Oxy and deoxy Hb can be represented by total and difference Hb as below: Total Hb: Total=Oxy +eoxy (1) ifference Hb: O_= Oxy eoxy (2). Fig. 2 is showing traces of above variables. The quick components of Oxy Hb and eoxy Hb are in opposite phases, thus by the addition of quick components, they are almost compensated each other, while by subtraction, the quick component is almost doubled in amplitude. Applying moving average of 2 second, quick and slow components of Total and O_ can be Fig. 1 Raw traces of IRS derived. Slow total Hb: slow total=average (Total) (3) Slow difference Hb: slow O_= Average (O_) (4) Quick total Hb: Quick T= Total -Average(Total ) (5) Quick difference Hb: Quick O_ = O_-Average(O_) (6) 0.1 ch- 8 O_ ch- 8 AVC_O ch- 8 TTL TASK 0 0.1 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 15 Fig.2 Total Hb(red) and difference Hb(green) and the slow O_ (blue) among the middle of difference Hb (O_) trace. Square trace indicates on and off of task. 2 4/10/2009 21:03:19

M. Fuchigami: Finger selection 0.2 0.1 0-0.1 TTL ch-3 Quick Task RESP -0.2 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 Fig. 3 Traces of Quick O_ and Quick total, sampled at every 0.1 sec. Thus the analysis of quick components of IRS can be concentrated to the quick O_. The quick components derived from eq. (5) and (6) are shown in Fig. 3. The magnitude of quick total is about 1/10 of quick O_. 3 Button Selection Task 3.1 Experimental Systems IRS (ear Infra-Red Spectroscopy) facility was a product of Shimadzu co. (OMM3000/12) which is installed in Future ITC Research Center, KARC (Kansai Advanced ICT Research Center, Akashi, Kobe, Japan). The authors were honored by Joint Research Treaty with the center to use the IRS facility. The IRS had 12-16 light transmitter and receiver pairs and was capable of processing up to 54 channels of brain activities depending on transmitter and receiver arraignment. The arraignment we adopted in measurement is shown in Fig. 4. By this arraignment, 48 channel brain activities are collected at every 0.1 second interval. Beside IRS data, the machine is capable of 8 external analogue signals, which are used to record start, stop, button operations and task completion signals together with IRS data. Experimental task design and the analysis methods are developed by authors. At this moment, the subjects participated in the measurement are graduate students, F Emitter Reciever 1 1 1 2 2 9 23 9 24 10 3 4 5 25 26 27 2 6 3 7 3 10 28 11 29 11 8 9 10 30 31 32 4 11 4 12 5 45 8 46 12 33 12 34 13 13 14 15 35 36 37 L 5 16 6 17 6 13 38 14 39 14 R 18 19 20 40 41 42 7 21 7 22 8 47 16 48 15 43 15 44 16 L F Fig. 4. Transmitter/receiver arraignment 48 channel data are collected at 0.1sec. interval. R 3 4/10/2009 21:03:19

Analysis of button operation by IRS. volunteered with informed consent in accordance with the Institutional Review Board of Kobe Women s University. Analysis for larger population should be reported elsewhere. 3.2 Finger Selection Task (Button Selection) Subject rest her hand (left or right) on the button box. Subject operated a button in accordance to the instructions generated by computer and presented either on visual display or by computer reproduced voice. Instructions were to choose a button either one of right, left, up or down. The subject fingers are allocated at home position, in which middle finger stay in the location of center. Fig. 5 shows the case, the box is operated by left hand from left side. In case of up or down instruction, index or ring finger might be selected 0.07 0.06 0.05 0.04 0.03 0.02 0.01 Fig. 5 Button selection by left hand ( side entry) to operate a red button. In case of right or left, middle finger has to change its location by changing the bending angle. The change in necessary action might be related to different brain activities to be analyzed in this paper. Two methods of visual presentation are used in case of visual display, i.e. by letter ( 上, 下, 左, 右 ) and by pictogram (,,, ). An instruction to operate is presented once by 3 second in average; the order of instruction is randomized. The instruction is presented on display for 1.1 second. The operator completed the button push tasks almost within 1.1 second. The average response time was in between 0.4-0.8 second depending on the instruction. The responses were all correct. Analysis of this paper will be limited within the left hand, side entry data (20 trials). The essential bases of quick component analysis will be explained by applying the method to the button selection data. Total analysis and comparison of all the data are beyond the scope of this paper. Q O_ 0 1 3 5 7 9 11131517192123252729313335373941434547 田辺 _20080331_1510_QQR L side Pict FIC48 Fig. 6 Quick component distribution around the channels. Ordinate scale in mmol/l cm. 4 4/10/2009 21:03:19

M. Fuchigami: Finger selection 3.3 Analysis of Quick Components Unified quantitative formulation of quick component is necessary, for the comparison of quick components, derived from various channels at various tasks. An appropriate function applicable to noise like signal as quick components is Avedev ( Microsoft Excel function), which is average of absolute difference of data and their mean value. In our analysis, slow component is subtracted from O_ signal, thus the mean value of quick component is assumed to be zero. In short, avedev is time average of absolute value of quick components. In the previous papers, long term (>30second) distributions of quick components around different channels and their changes related to tasks are reported [4]. A distribution proper to the case of this paper is shown in Fig. 6, where pictogram is used for instruction display, and operator used left hand at side entry position. Avedev is stable in value, when averaging interval is taken 10 seconds or longer. It change considerably as averaging interval is shorten, reflecting change of brain activities under the recording. In this paper, a method to evaluate short term change in brain activities is analyzed by introducing two parameters, M (magnitude) and (density), related to Q.( avedev of quick component). The relation of these parameters is formulated as below. Here Q = M * (7) M = max (max (member), -min (member)) (8) member: data within averaging interval. enoting : the number of data in the interval, inequality below is derived. 0< 1/ < < 1 (9) Inequality (9) states that the density remains within the bound of 0 and 1. Further studies are concentrated to the change of M and, in succession of averaging cycles. 4 Response Analyses Video on off Instruction Fig.7a Video on/off (- up/down), button instruction (,,, ) and the button responses (+). Quick component is analyzed below taking the averaging interval 1.1 second. Some time traces of specific channels are shown in Fig. 7 b) - e). otations for video on/off and button selection are explained in Fig. 7 a). Instruction display is on when - symbol is in higher position, and while instruction is off, the - symbol is in lower position. Result of button selection is shown by distance from display interval line (-). 5 4/10/2009 21:03:19

Analysis of button operation by IRS. Instruction is shown by pictogram (,,, ) adjacent to corresponding + symbols in Fig. 7a). Symbol (+) touching just above video on sign is correct response to right ( ) instruction, while one touching just below is corresponding to ( ) instruction. Symbol (+) above and below apart from video on sign is corresponding to up( ) and down ( ) instruction. 4.1 Visual Analysis Fig 7b) illustrates -min. and 0.1 (density) of each averaging interval in succession, together with display and response detail while performing button selection task. Blue trace illustrates the min. Readers might realize many peaks of blue trace are synchronized to the video and the response sign. The peaks synchronized to response signs are illustrated by filled symbol of enlarged size. Time location of synchronization is denoted by letter. 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 35 -min 0.1 max MARK R Video on Instruction off 0.00 0.0 10.9 21.2 31.7 41.9 52.4 62.7 73.1 83.4 Fig. 7b) Response synchronization of min. wave form to various instructions, denoted by. In general synchronizations of peaks and responses occur frequently in response to various instructions, but not consistently to a definite instruction. But ch.35 is a specific channel, which shows synchronization to one specific instruction. 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 35 -min 0.1 max MARK R Instruction Video on off 0.00 0.0 10.9 21.2 31.7 41.9 52.4 62.7 73.1 83.4 Fig. 7c). Response synchronization of max. wave form to various instructions, denoted by. 6 4/10/2009 21:03:19

M. Fuchigami: Finger selection Fig. 7c). is the similar trace as Fig.7b). The only difference is replacement of min. by max. waveform. Synchronization also happens with max. Synchronization points are indicated by marks, and square notations of enlarged size. Total 10 marks are indicated in the figure. Five of them are in responses to up instructions. All the up instructions are responded by synchronization of max. waveform. This is what we mean by consistency. Certain channel of the brain seems to respond consistently to certain instruction response combination. 0.25 0.20 3 M 0.1 Video R 0.15 0.10 0.05 0.00 0.0 10.9 21.2 31.7 41.9 52.4 62.7 73.1 83.4 Fig.7d) Response synchronization of magnitude (max. min) and density () wave forms of ch. 3 to various instructions, denoted by, and. ouble synchronizations (+) and (+) are identified in time zone between 10.9 and 21.2. 15 M 0.1 Video Resp 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0.00 0.0 10.9 21.2 31.7 41.9 52.4 62.7 73.1 83.4 Fig. 7e) Response synchronization of magnitude (max. min) and density () wave forms of ch. 15 to various instructions, denoted by, and. ouble synchronizations, two (+) and one (+), are identified in time zone between 31.7 and 62.7. Without saying, channels with large magnitude of quick components might show synchronization. It is true. Two major channels, ch. 3, and 15 are selected out from channels of large magnitude of quick components and the synchronization points are shown by colored notation on magnitude trace in Fig.7d) and e). Synchronization happens not always with one waveform. When max. and min waveforms are close to each other temporarily, double synchronization happens. ouble synchronization cannot be indicated by a mark in the graph. Thus synchronization are denoted by text and, beside notation mark. In many cases, marks often overlaps with other 7 4/10/2009 21:03:19

Analysis of button operation by IRS. marks, double indications are useful. ouble synchronizations also happen between density waveform and max. or -min. Some cases of double synchronization between and, and between and are shown in Fig. 7d) and in Fig.7e). Prominent synchronizations are remarkable but consistency is not found in Fig. 7d) and e). 4.2 Computer Analysis Table 1 Channels with large quick components. Channel / Instr TIME 3 7 9 10 15 30 35 29.5 23 5 37.8 14 11 50.2 7 62.7 9 9 79.3 10 29.5 5 37.8 7 8 50.2 12 11 62.7 23 8 9 79.3 6 21.2 8 46.1 12 58.5 5 15 75.1 6 7 21.2 18 17 46.1 11 9 58.5 14 9 75.1 12 11 8.7 9 8 8 17 14 11 41.9 9 70.9 8 12 87.6 12 16 8.7 10 17 7 6 41.9 10 7 70.9 6 10 9 87.6 13 8 10 11 6 12.9 10 10 25.3 12 33.6 8 12 54.4 23 6 10 13 66.8 7 8 83.4 10 8 12.9 16 7 8 8 25.3 8 8 11 33.6 10 54.4 14 12 66.8 11 83.4 7 9 For the further minute studies, visual analysis of every one peak is powerless. The computer algorithm, shown below, is applied to1920 data points, which are 48 channels*20 trials*2 wave forms (max,-min). The results are shown in Table 1 and 2. Table 1 is concerned with 7 channels with big magnitude, and Table 2 is concerned with 18 channels with some consistency. Other 23channels not belonging to either groups are to be mentioned elsewhere. The consistency is graded in three levels, full ( >80%), fair (80~60%) and low (<60%). In Table 1, channel 35 showed full consistency to up ( ) instruction. Channel 2 to right ( ) and 9 down( ) showed fair consistency. There were no candidate channels for consistency in synchronization. Algorithm for synchronization detection m = max or -min of current interval m E : m of previous interval m : m of succeeding interval m = IF(and(m*g> m E, m*g> m ), m*100, ) g= 0.9: peak margin In order to avoid decimal point, m s in the table are shown after multiplied by 100. 8 4/10/2009 21:03:19

M. Fuchigami: Finger selection Table 2 Channel group related to response consistency CHAEL / Instr TIME 1 2 3 4 9 11 20 21 22 27 31 33 34 35 38 39 40 46 29.5 2 23 1 5 37.8 4 3 2 50.2 2 2 3 4 6 62.7 1 9 2 2 4 5 79.3 3 5 3 29.5 3 4 5 1 4 2 5 2 6 37.8 6 7 3 8 2 50.2 1 12 4 2 2 6 11 2 5 62.7 23 2 3 1 9 79.3 3 5 2 4 6 6 2 2 3 4 21.2 5 2 3 8 2 3 46.1 4 7 2 3 58.5 4 2 5 7 7 3 75.1 1 1 4 2 7 2 6 21.2 1 18 5 3 2 3 1 4 3 46.1 1 11 2 5 3 58.5 1 14 2 3 8 7 75.1 1 12 4 4 8.7 4 4 1 5 8 8 2 3 17 1 14 2 3 2 6 2 3 41.9 2 1 7 9 3 2 3 70.9 2 4 4 6 87.6 7 3 1 7 5 8.7 3 5 10 2 1 6 3 6 17 6 6 3 1 5 6 2 6 41.9 7 6 7 70.9 5 2 6 2 9 3 87.6 1 13 5 10 2 3 6 4 6 12.9 3 10 6 3 3 2 25.3 3 1 5 3 33.6 4 2 4 4 5 2 3 7 54.4 4 23 7 8 2 2 66.8 4 2 3 6 2 8 3 3 6 83.4 2 1 3 4 1 5 8 3 3 4 12.9 16 4 7 2 8 25.3 8 2 3 11 33.6 2 6 54.4 6 4 2 6 66.8 5 2 2 5 2 2 3 83.4 2 2 6 1 full consistancy full consistancy. fair consistancy fair consistancy 5. Consistency Channels In the Table 2 are collected synchronization distributions of consistent group. First five line from the above are synchronization for up instruction( ). Full consistency channels are not found in these lines. In the second 5 lines from the above, synchronization for up instruction( ) shows full consistency in 11 and 35 channels. Fair consistency is also found in 22 and 39 channels. 9 4/10/2009 21:03:19

Analysis of button operation by IRS. In the third 4 lines from the above, synchronization for right ( ) instructions are shown. Full consistency channels are not found, but fair consistency is found in channel 20. In the next 4 lines from the above, synchronization for right ( ) instructions are shown. Full consistency is found in channel 2, and fair consistency is found in channel 3 and 31. In the 5 five lines by the middle of the Table2, synchronization for down( ) instructions are shown. Full consistency is found in channel 33 and fair consistency is found in channel 27. ext 5 lines below are synchronization for down( ) instructions are shown. o full synchronization but two fair synchronization channels are found in channel 4 and 9. In the bottom of Table 2, and synchronization for left ( ) instruction are shown. o full consistency channels but fair consistency is found in some channels. One question is why no full consistency for left ( ) instruction. It may be related to the experimental set. This experiment used the left hand, side entry task as explained in chapter 3. In this set up, to touch left and right button middle finger of left hand has to be extended or constricted. These actions will be more complex compared to up and down action which is simple touching to a button. The effects of different finger selection and actions can be examined by changing hand rest position, and by comparing results of left and right hands. * Emitter Actions Recepter # Channel F 1 * 2 23 * 24 3 4 5 25 26 27 * 6 7 * * 28 29 * 8 9 10 30 31 32 11 * 12 45 * 46 33 * 34 13 14 15 35 36 37 L * 16 17 * C * 38 39 * R 18 19 20 40 41 42 21 * 22 47 * 48 43 * 44 full consistancy full consistancy fair consistancy fair consistancy Fig.8 Allocation of full and fair consistency channels for left hand side entry operation. Instruction and action direction are indicated by arrows. In conclusion of synchronization analysis, consistency allocation for the left hand side entry operation is illustrated in Fig. 8. Table 1 is channel group with active quick components and effecting to almost all activities but not always specifically related to certain tasks. Table 2 is the channel group which are not always active in quick component but certain consistency to finger selection is confirm by this analysis. Some more channels are supposed to be included to Table 2 group based on further analysis related to left/right hand and top/side entry variations. Still more channels are expected 10 4/10/2009 21:03:19

M. Fuchigami: Finger selection to enter the group based on instruction presentation variations. At the moment 23 more channels remain out of either group. Further analysis is done with the density related to finger selection. The IRS analysis[7] of continuous events so far suggests that the channels actually working are less variable, so that standard deviations are small, while channels out of work show large deviation. Similar trend are observed also in finger selections task. 6. Conclusion Button operation by finger is still most essential activities supporting human computer interactions, to which not much is known about the brain functions. Quick component analysis is successfully applied to finger selection of button operation task. Magnitude and density analysis will extend the scope of brain function studies to real time activities. References [1] Tamura, H., Omori, M., Choui, M.: IRS trajectories in Oxy-eoxy Hb plane and the trajectory map to understand brain activities related to human interface, pp. 994-1003, Proc. HCII 2007, Springer-Verlag, 2007/7 [2] Fuchigami, M., Okada, A., Tamura, H., Omori, M.: A Comparative Study of Brain Activities Engaged in Interface Operations by Means of IRS Trajectory Map, pp. 830-839, Proc. HCII 2007/7, Springer-Verlag 2007. [3] Tamura, H., Fuchigami M., Okada A., Omori M., Hasegawa S., Fujikake K., Choui M. : On Physiological Roles of Quick Components in ear Infrared Spectroscopy (in Japanese), Proc. Mobile Interactions 08, pp. 97-102, Society of Mobile Interactions, 2008/7 [4] Tamura, H., Fuchigami M., Okada A.,: On Physiological Roles of Quick Components in ear Infrared Spectroscopy (in Japanese), Proc. Mobile Interactions 08, pp. 97-102, Society of Mobile Interactions, 2008/7 [5] Tamura, H., Fuchigami M., Okada, A.: Analysis of Text Entry behavior by IRS Quick Components, Proc. Mobile Interactions 09, pp. 109-114, Society of Mobile Interactions, 2009/3 [6] Fuchigami M., Okada, A., Tamura, H.,: Analysis of IRS Quick Components in directionselective button operations, Proc. Mobile Interactions 09, pp. 115-120, Society of Mobile Interactions, 2009/3 [7] Tamura, H., Fuchigami, M., Okada, A., euro-irs: Analysis of eural Activities using IRS, HCII2009 11 4/10/2009 21:03:19