DA MHz Series of Narrowband or Wideband Distribution Amplifiers

Similar documents
DA : Series of Narrowband or Wideband Distribution Amplifiers

DA E: Series of Narrowband or Wideband Distribution Amplifiers

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

MULTIBAND 1/3 RACK-MOUNTED

1/3 RACK-MOUNTED BLOCK CONVERTERS

Signal Stability Analyser

Indoor Dual Converter

SYNTHESIZED COMMUNICATION CONVERTERS

Multiple Band Outdoor Block Up- and Downconverters

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

High Performance Outdoor Test Translators

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

X-Band Redundant LNB Systems

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

Synthesized Clock Generator

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

R-1580A Microwave Downconverter. Product Brochure

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

Orbital Ka-ISO. Ext Ref Ka LNB with integrated isolator. Orbital Research Ltd Marine Drive, White Rock, BC. Canada V4B 1A9

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

Typical applications:

Ku-Band Redundant LNB Systems

Modular Block Converter Systems

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

C-Band Redundant LNB Systems

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

Inmarsat Downconverter Narrowband Downconverter

Instruction Manual Model # Block Upconverter

4400X Series. Orbital. X-Band Ext Ref LNB. MIL Spec MIL-STD A, 45 db internal filter LNB630S-500X-WN60-G12. Orbital Features: Orbital Specs:

Instruction Manual Model BlockUpconverter

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

ThinkRF D GHz RF Downconverter

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

High-Value 100 Series (Outdoor)

Orbital 4400X & 4400XI Series X-Band Ext Ref LNB

Wideband LNB: 2.4 GHz

Datasheet SHF A

R3267/3273 Spectrum Analyzers

Synthesized Block Up- and Downconverter Indoor / Outdoor

Synthesized Block Up- and Downconverter

Redundant LNB Systems

THE ART OF ENGINEERING

SIDC-5009 Series VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

Technical Data. HF Tuner WJ-9119 WATKINS-JOHNSON. Features

VM-100R. 1 RU HEIGHT PROGRAMMABLE 70 AND 140 MHz HIGH-PERFORMANCE VIDEO/AUDIO MODULATOR

Redundant LNB Systems

SIDC-5004 VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

clipping; yellow LED lights when limiting action occurs. Input Section Features

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

National Park Service Photo UTAH-1OO/3. MADI Terminal.

11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS

SATCOM FIBER OPTIC PRODUCTS

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

DVO700 P FIBRE OPTIC TRANSMITTER

SCR Series Synthesized Converters L, C, X, Ku, and DBS Bands

SIR MICROWAVE WIDEBAND DSP RECEIVERS UP TO 26.5 GHz. WIDE FREQUENCY RANGE: GHz

The Art of Engineering

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

OPTICAL DISTRIBUTION STATION -

Redundant LNB Systems

Satellite Up- and Downconverter Indoor / Outdoor


USB-TG124A Tracking Generator User Manual

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS

Satellite Up- and Downconverter

Advanced Test Equipment Rentals ATEC (2832)

ACION 8000 Series. A8KFR1 1RU Forward Receiver

INT-DS2 DVB-S/S2 SATELLITE MODULATOR DVB MODULATOR

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure. 1

RF Semiconductor Test AXRF RF Port Upgrade Kits

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

2 MHz Lock-In Amplifier

PiMPro Portable Analyzer PiMPro Classic 1821

PONA 3000 Series Erbium Doped Fiber Amplifier

Technical Description

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

ModuMAX SSPA Systems. C, X, and Ku Bands. Completely modular solid-state power amplifier systems for world-wide satellite communications

PONA 3000 Series Erbium Doped Fiber Amplifier

EX04-000D. DVB-T/2xT/T2 MODULATOR DVB MODULATOR

Agilent E5100A Network Analyzer

L-Band Block Up- and Downconverter Indoor / Outdoor

Power Amplifier 1.5 MHz to 18 GHz, Split Bands. Now with smart digital monitoring and control options 19 Rack Mount Family Data Sheet

PiMPro Rack Mount Analyzer

LT-82 Stationary IR Transmitter

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

PAM-1840 Preamplifier Operation Manual

! "#$ ' % & % & ' ( )!' *!+, ( *-"(! './ 0 / 0/ $ 1/ 2$3 1

Microwave Counter, Power Meter and DVM in One Portable Package

DVM-3000 Series 12 Bit DIGITAL VIDEO, AUDIO and 8 CHANNEL BI-DIRECTIONAL DATA FIBER OPTIC MULTIPLEXER for SURVEILLANCE and TRANSPORTATION

IRT Eurocard. Type RWA RF Distribution Amplifier for 70 MHz IF signals

GPON EDFA with WDM for IP(OLT) Wavelengths Multiple Optical Outputs

Transcription:

DA1-100-10-10MHz Series of Narrowband or Wideband Distribution Amplifiers Key Features 1-10 MHz wideband Operation. Other band frequencies from 100 khz to 200 MHz are available AGC Level Controlled. Output level remains stable to 0.02 db even if input varies AGC can be disabled if required. Amplifier then has fixed gain. Different gains can be made upon request 5 to 40 sinewave outputs. Each output can be independently set to 0 dbm to > +10 dbm (option +20 dbm) Alarm monitoring. All outputs have alarm monitoring. Indication by LEDS or rear panel DC outputs Ultra low phase noise. Typically, < -140 dbc @ 1 Hz offset. Floor noise to -171 dbc/hz available. Excellent Allan Deviation. 2 x10-14 at 1 sec, 2 x10-17 at longer time intervals. >90 db channel isolation and >130 db reverse isolation. Protects reference input and prevents cross-talk. BNC Connectors standard. SMA or TNC or N type connectors optionally available. Optional second frequency Back-up input. Automatically switched in, if first input fails. Optional internal back-up oscillator. Automatically switched in, if external input fails. Optional Redundancy (two units with automatic switchover) Many other options and customized options. Bespoke design service available. General Description The DA1-100-10-10MHz is a 1 to 10 MHz distribution amplifier. It can be used to synchronize from five to forty instruments to a 10 MHz frequency reference input. The reference input will typically be an OXCO, Rubidium, Caesium or Hydrogen Maser Frequency Standard. The DA1-100-10-10MHz has features not found in any competitive unit. This makes this amplifier the industry s leading 10 MHz distribution amplifier. It has outstanding low phase noise, meaning no additional phase noise will be added to the reference input. Phase noise is typically <-140 dbc @ 1 Hz offset. This low phase noise enables units to be cascaded for over 1000 outputs. Amplifier with Gain and Automatic Gain Control (AGC) Unlike most competitive units, this amplifier accepts inputs from +7 dbm to +20 dbm (-20 dbm to +30 dbm optional) and provides outputs from 0 dbm to > +10 dbm (up to +20 dbm optional). The output will not vary with input variations. This is very useful when long cable runs are being used or equipment has different input level requirements. The AGC can be disabled, if required, making the unit a fixed gain amplifier. Different gains are available upon request.

Outputs There are five to forty sinewave outputs depending upon what option is ordered. Each output is completely isolated from the input and each other. Therefore, the reference oscillator connected to the amplifier s input is protected against load variations, short circuits etc. that may be applied to the outputs. Channel to channel isolation is > 90 db @ 10 MHz. Output to input isolation is > 130 db @ 10 MHz Each output port can be independently set to any level from 0 to > +10 dbm on the standard unit and outputs to +20 dbm are optional available. The ability to set every output to a different level is very useful when dealing with equipment that has different input level ranges. This is a unique feature of this amplifier not found on any other unit. Phase Noise The DA1-100-10-10MHz has very low phase noise and Allan deviation. This enables units to be connected in series without adding any appreciable noise to the reference input. Up to 1000 outputs can be derived from one input using multiple amplifiers, without the need of cascading more than three amplifiers at a time. This keeps the phase noise to a minimum. A typical plot of phase noise at 10 MHz is shown below in blue. Note this is an amplifier with 0 db gain. The standard DA1-100-10-10MHz has 3 to 6 db of gain which raises the noise by a few db. Allan Deviation Plot The plot below shows the Allan deviation plot of the DA1-100-10-10MHz. Allan Deviation is typically 1.8 x 10-14 for tau = 1 second with the noise floor less than 2 x 10-17.

Phase Stable with matched outputs The wide frequency bandwidth allows the outputs to have stable phase. The phase stability is typically 5 ps/ C. Also the delay match between outputs is better than 2.2 ns overall and typically less than 350 ps between groups of five outputs. Alarms Every output has alarm monitoring. Should the RF level drop on any output, an alarm will be raised. Also, front panel LED s show the status of the alarms. The alarm signals are also available on the rear panel as DC level outputs. Applications The DA1-100-10-10MHz Distribution Amplifier is ideal for use in calibration or standard laboratories, space research, satellite systems, communication systems or anywhere where ultimate performance is needed. Miscellaneous Information This amplifier is a highly reliable unit. It is housed in a fully screened 19 rack mount case and operates from a 100 to 240 VAC supply (usable 90 to 260 VAC). The amplifier is CE marked for sale within the EEC. It is guaranteed for three years. Options and Other Amplifiers available from Precision Test Systems Fully DC isolated outputs. Useful in preventing ground loops on long cable runs. Squarewave outputs. Either at the same frequency as the input, or at different frequencies. Multiplied or divided outputs. E.g. 10 MHz, input with 5 MHz output. 10 MHz input with 100 MHz output. Any type of multiplication / division can be incorporated. Guaranteed phase noise specifications. Measured phase noise specifications supplied with unit. Higher output levels, up to +30 dbm. Different amplifier gains allowing different input levels from -20 dbm to +30 dbm to be accommodated. Additional outputs. Up to 20 outputs in a 1U case or 40 outputs in a 2U case. External DC Power Input. The DA1-100-10-5MHZ can also have an external 12VDC input. This can be used to provide back up power. If AC power is lost, the DA1-100-10-5MHZ will immediately switch to the DC supply.

Redundancy. Two units operate together. If one unit fails, the outputs are automatically switched to the secondary unit. Internal backup oscillator. This oscillator is automatically enabled should the input signal fail. Two reference inputs. Each reference input with have five isolated outputs derived from it. So the amplifier can operate at two different frequencies at the same time. E.g. 10 MHz and 5 MHz, 10 MHz and 1 MHz. Amplifier Rear view (with option 04 TNC Connectors). Precision Test Systems also manufacturers the PTS50 and DA1010 series of distribution amplifiers. These models are lower cost alternatives but still give very good performance. DA1-100-10-10MHz SPECIFICATIONS Specification Parameter Specification Comments Input Frequency 1-10 MHz See model list below for actual frequencies Bandwidth (2-100 MHz) ± 3 db Impedance / Input VSWR 50 Ω / < 1.5:1 @ 10 MHz Typically, < 1.2:1 @ 10 MHz Input Level (standard unit) +7 dbm to + 20 dbm AGC Controlled. Optional -20 to +30 dbm Gain (standard unit) 3 db (optional -5 to +30 db) AGC controlled or fixed gain options. Sinewave Outputs Output Waveform Sinewave 50 Ω BNC Connector on rear panel Output Frequency Output VSWR Exactly the same as the input < 1.15: 1 @ 10 MHz Output level (individually adjustable) Adjustable 0 dbm to > +10 dbm Outputs to +20 dbm optionally available Output Level Stability < 0.05 db / C Typically, < 0.02 db / C Harmonic Distortion (10 dbm input) -20 dbc Typically -25dBc (optional; -50 dbc) Spurious Outputs (> 500 khz) -125 dbc Typical Channel to Channel Isolation Input to Output Isolation > 90 db @ 10 MHz > 130 db @ 10 MHz Delay match between outputs < 2.5 ns (<500 ps / 5) < 500 ps within group of 5 outputs Temperature Stability of delay 10 ps/ C Typically 5 ps/ C Slave Output Slave Output Passive output derived from input Level = input level - 7 db. Allan Deviation (typical @ 10 MHz) Allan Deviation < 4 x 10-14 (1 sec) < 2 x10-13 at 0.1 sec. Floor < 3 x 10-17 Phase Noise (@ offset frequency) with +10 dbm input and +10 dbm output Phase Noise (@ offset frequency) with +13 dbm input and +13 dbm output Phase Noise for standard unit (typical @ 10 MHz) @ 1-135 @ 1-140 @10-148 @10-157 @100-157 @100-166 @1k -163 @1k -170 @10k -165 @10k -171 @100k -166 @100k -171 General Power (AC) 100-240 VAC (usable 90-260) 50 Watts max This is for a unit with ten outputs and a gain of 3 to 6 db This is for a unit with five outputs and a gain of 0 db

Size and weight (5 to 20 outputs) 483 x 300 x 44 mm and 2.8 kg Width x Depth x Height Size and weight (20 to 40 outputs) 483 x 300 x 88 mm and 3.5 kg Width x Depth x Height Operating / Storage Temperature -10 to +50 C / -20 to +80 C Humidity < 90% non-condensing Alarm Output Alarm Outputs on rear panel Options (not all options can be fitted at the same time) Option 01 Dual changeover alarm relay Activated in the event of an alarm Option 02A / B Ground Isolated Input / Outputs Option 03 Redundancy Requires two units Option 04 / 05 / 05B TNC / SMA/ N type connectors Replaces standard BNC connectors Option 06 Guaranteed Phase Noise Plots supplied with unit Option 07 UKAS traceable certificate Option 08 Increased Output levels Various options to +20 dbm available Option 09, 09A, 09B, 09C, 09D Additional sinewave outputs 20 o/p s in all in 1 U case. 40 outputs in 2U case. AGC range 10-19dBm Option 10 Squarewave outputs TTL/CMOS or ECL output levels Option 11 Divided frequency output E.g. 2.048 MHz, 1MHz, 10 MHz, 1 pps etc. Option 12 Multiplied output E.g. X2, X5, X10, X100. Option 13 Low Pass filter on output Improved harmonic rejection Option 14 External DC input Nominal 12V external DC. Option 16-XXX Internal backup oscillator XXX = frequency in MHz. Option 17-XXX Different Gain Levels Customer to advise gain requirement Option 18 Delete five outputs Negative option. Reduces price. Option 19 Second External Input Automatic switchover if 1 st input is lost Option 20 Two reference inputs With two sets of five outputs Option 22 Additional internal amplifier Increases sensitivity to -20 dbm Option 23 Bandwidth optimized Specify actual frequency bandwidth Option 25 2 inputs with 8 outputs each. Customer special option Option 26 / 26B Option 27 Fiber optic input and outputs Ethernet interface for alarms Precision Test Systems Head Office - UK South Africa USA Precision Test Systems cc Randburg Gauteng South Africa Fax: 08651 58198 Email: sasales@ptsyst.com Web: www.ptsyst.com Precision Test Systems LTD The Studio, Whitehouse Farm New Hall Lane, Mundon Maldon, Essex, CM9 6PJ, UK Tel: +44 (0) 870 368 9608 Fax: +44 (0) 1245 330030 Email: sales@ptsyst.com Web: www.ptsyst.com Precision Test Systems 304 S. Jones Blvd, Suite # 807 Las Vegas Nevada, 89107 USA Tel: 1 888 876 4804 Fax: 1 832 201 6564 Email : usasales@ptsyst.com Web : www.ptsyst.com Further information available from www.ptsyst.com. Specifications and features subject to change without notice (090816)