AS09..S 3-pole Contactors - Spring Terminals

Similar documents
TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

A V 50Hz / V 60Hz

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Type: DILM25 10(24V50HZ) Article No.:

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Type: DILM12 10(24VDC) Article No.:

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Minicontactorrelay,2NO/2NC,DCoperated

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

Series CT7N Bimetallic Overload Relays

Bulletin 190 IEC Modular Starter System

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Manual Motor Starter Specifcations

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME. Main. Device short name. Device application

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Magnecraft Power Relays

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

GV2P05. Main. Device short name. Device application

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

GV2ME. Main. Device short name. Device application

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

02/11/2015

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

Datasheet - SRB301LC 24VAC/DC

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

TeSys circuit-breakers

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

AC1036. Definite Purpose Contactors

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Ordering details. Approval. Classification

Kuhnke Technical Data. Contact Details

Interface Relays and Optocouplers Product group picture

Series CDP2 Definite Purpose Contactors

TeSys contactors LC1-D09pp (5) LC1-D12pp (5) 0.325

Accessories Order No. Page Individual parts Order No. Page K1 1) K3 2) K2 2) 14 Auxiliary switch block, front. 3/105 terminals.

ALLEN BRADLEY TIMING RELAY

Series CDP2 Definite Purpose Contactors

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

Data Sheet Definite Purpose Contactors Ex9CK Series

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Contactors and Contactor Assemblies

Pluggable interface relays CR-M Miniature relays

Bulletin 100-G IEC Contactors

Modular pulse operated latching relay 16 A

Datasheet - SRB-E-201ST

8 Installation Equipment

Power Circuit of a UL508A Panel. Typical UL489 Application

Pluggable interface relays CR-M Miniature relays

llen-bradley 194R-HM4-NFPA3

Selection guide siemens.com/sirius-modular-system

16 A and 25 A power contactors with or without handle

LED Driver Linear / area fixed output

MILLITARY SPECIFICATION SHEET

Bulletin 100-G IEC Contactors

Safety dialogue solutions

Generator protection relay

LED Driver Compact dimming

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Features XT SC 012 B B A

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

Features XT SC 012 B B A

LED control gear Compact fixed output

Transcription:

4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional surge suppressor which does not increase overall dimensions. Main accessories available: - Up to 2 add-on CA3..S 1-pole auxiliary contact blocks, - VM3 mechanical interlocking without additional width, - RV5 or RC5-1 surge suppressor. IEC AC-3 rated operational power 4 kw 400 V UL/CSA 3-phase motor power 5 hp 440-480 V culus CCC CE Ordering Details Main poles + Built-in aux. contacts A1 A2 A1 A2 1L1 3L2 5L3 2T1 4T2 6T3 1L1 2T1 3L2 4T2 5L3 6T3 13 NO NO 14 21 NC NC 22 For other coil voltage see 1SBC101023S0201.pdf Control coil voltage Type Order code Pack (ing) Weight 50 Hz 60 Hz pieces kg (1 pce) 24 V 24 V AS09-30-10S-20M 1SBL 101 004 M2010 40 0.22 110 V 110 V AS09-30-10S-23M 1SBL 101 004 M2310 40 0.22-120 V AS09-30-10S-16M 1SBL 101 004 M1610 40 0.22 230 V 230 V AS09-30-10S-26M 1SBL 101 004 M2610 40 0.22 24 V 24 V AS09-30-01S-20M 1SBL 101 004 M2001 40 0.22 110 V 110 V AS09-30-01S-23M 1SBL 101 004 M2301 40 0.22-120 V AS09-30-01S-16M 1SBL 101 004 M1601 40 0.22 230 V 230 V AS09-30-01S-26M 1SBL 101 004 M2601 40 0.22 Mounting positions Main For complete technical data see.pdf Main poles Rated operational voltage U e max. 690 V IEC AC-3 Utilization category (for 1500 r.p.m., 50 Hz or 1800 r.p.m., 60 Hz, 3-phase motors) for air temperature close to contactor θ 55 C AC-3 rated operational power 400 V 4 kw I e / AC-3 max. rated operational current 400 V 9 A I e / AC-1 rated operational current 20 A (Ue max. 690 V, 50/60 Hz for air temperature close to contactor θ 40 C) I e / AC-8a rated operational current 12 A (without thermal overload relay - Ue 400 V - θ 40 C) UL/CSA 3-phase motor (for 1500 r.p.m., 50 Hz or 1800 r.p.m., 60 Hz) Motor power 440-480 V 5 hp Amp rating 440-480 V 7.6 A General use Amp rating 600 V 12 A Magnet system Coil operating limits (acc. to IEC 60947-4-1) 0.85... 1.1 x U c (θ 60 C) Average pull-in coil consumption value 50/60 Hz 33 VA Average holding coil consumption value 50/60 Hz 6.5 VA / 1.5 W Built-in aux. contacts Rated operational voltage U e max. 690 V IEC I e / AC-15 rated operational current 400-415 V 3 A acc. to IEC 60947-5-1 I e / DC-13 rated operational current 24 V DC 6 A (144 W) UL/CSA Pilot duty A600, Q300 Max. electrical AC-3 1200 cycles/h switching frequency AC-1 600 cycles/h Connecting Main pole terminals Rigid capacity Flexible with AWG 1 or 2 AWG 18-12 Coil and built-in Rigid auxiliary contact Flexible with terminals AWG 1 or 2 AWG 18-14 Degree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 IP 20 Pos. 2 +30-30 Pos. 4 Pos. 3 45 1.77" 7 0.28" 72.5 2.85" 10 0.39" 2 x M4 8-32 UNC 35 1.38" ø 4.2 0.17" Pos. 5 Pos. 1 Pos. 1 ± 30 68 2.68" 35 mm EN/IEC 60715 5.5 0.22" 60 2.36" 50 1.97" Dimensions: mm, inches 1SBC101002S0202 9

Main Pole - Utilization Characteristics according to UL/CSA NEMA size 00 00 0 00 00 00 General use rating Amp rating 600 V A 20 20 20 12 12 15.2 3-phase motor rating Amp rating M 3 200-208 V A 7.8 7.8 11 7.8 7.8 11 220-240 V A 6.8 9.6 15.2 6.8 9.6 15.2 440-480 V A 7.6 11 14 7.6 11 14 550-600 V A 9 11 11 9 11 11 Motor power 200-208 V hp 2 2 3 2 2 3 M 220-240 V hp 2 3 5 2 3 5 1500 r.p.m. 50 Hz 3 1800 r.p.m. 60 Hz 440-480 V hp 5 7 1/2 10 5 7 1/2 10 3-phase motors 550-600 V hp 7 1/2 10 10 7 1/2 10 10 Short-circuit protection for contactors without thermal O/L relay - Motor protection excluded Fuse rating A 40 50 60 40 50 60 Fuse type, 600 V J 1-phase motor rating Amp rating 120 V A 7.2 9.8 13.8 7.2 9.8 13.8 240 V A 8 10 12 8 10 12 Motor power 120 V hp 1/3 1/2 3/4 1/3 1/2 3/4 240 V hp 1 1 1/2 2 1 1 1/2 2 Max. electrical switching frequency for general use cycles/h 600 for motor use cycles/h 1200 General Rated insulation voltage U i according to IEC 60947-4-1 V 690 according to UL/CSA V 600 Rated impulse withstand voltage U imp. kv 6 Standards Devices complying with IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 Air temperature close to contactor without thermal O/L relay C -40... +70 for storage C -60... +80 Climatic withstand Category B according to IEC 60947-1 Annex Q Operating altitude m 3000 Shock withstand acc. to IEC 60068-2-27 and EN 60068-2-27 Mounting position 1 1/2 sinusoidal shock for 11 ms: no change in contact position AS contactors - AC operated ASL contactors - DC operated C1 Shock direction Closed position Open position Closed position Open position A 20 20 20 10 A A B1 B2 B1 10 5 15 5 B2 15 15 10 10 C2 C1 20 9 15 8 C2 20 14 14 8 Mounting positions Pos. 2 +30-30 Pos. 4 Pos. 3 Pos. 1 Pos. 1 ± 30 Mounting distances The contactors can be assembled side by side Fixing on rail acc. to IEC 60715 and EN 60715 35 x 7.5 35 x 15 with screws (not supplied) 2 x M4 screws placed diagonally Pos. 5 22

Built-in Auxiliary Contacts - Utilization Characteristics according to IEC Rated operational voltage U e max. V 690 Conventional free air thermal current I th θ < 40 C A 10 Rated frequency limits Hz 25... 400 Rated operational current I e / AC-15 acc. to IEC 60947-5-1 24-127 V 50/60 Hz A 6 220-240 V 50/60 Hz A 4 400-415 V 50/60 Hz A 3 500 V 50/60 Hz A 2 690 V 50/60 Hz A 2 Rated operational current I e / DC-13 acc. to IEC 60947-5-1 24 V DC A / W 6 / 144 48 V DC A / W 2.8 / 134 72 V DC A / W 1 / 72 110 V DC A / W 0.55 / 60 125 V DC A / W 0.55 / 69 220 V DC A / W 0.3 / 66 250 V DC A / W 0.3 / 75 Making capacity acc. to IEC 60947-5-1 10 x I e AC-15 Breaking capacity acc. to IEC 60947-5-1 10 x I e AC-15 Short-circuit protection gg type fuse A 10 Rated short-time withstand current I cw for 1.0 s A 100 for 0.1 s A 140 Minimum switching capacity V/mA 12 / 3 with failure rate acc. to IEC 60947-5-4 10-7 Non-overlapping time between N.O. and N.C. contacts ms 1.5 Heat dissipation per pole at 6 A W 0.1 Built-in Auxiliary Contacts - Utilization Characteristics acc. to UL/CSA Max. rated voltage 600 V AC, 250 V DC Pilot duty A600, Q300 23

Magnet System Characteristics for AC Operated Contactors Rated control circuit voltage U c - at 50 Hz V 24... 415 - at 60 Hz V 24... 415 Coil operating limits acc. to IEC 60947-4-1 0.85... 1.1 x U c (at θ 60 C) ; U c (at θ 70 C) Drop-out voltage in % of U c approx. 30... 50 % Coil consumption Average pull-in value 50 Hz VA 33 60 Hz VA 33 50/60 Hz VA 33 Average holding value 50 Hz VA / W 6.5 / 1.5 60 Hz VA / W 5 / 1.2 50/60 Hz VA / W 6.5 / 1.5 Operating time between coil energization and: N.O. contact closing ms 9... 24 N.C. contact opening ms 6... 18 between coil de-energization and: N.O. contact opening ms 5... 19 (1) N.C. contact closing ms 7... 22 (1) (1) The use of RC5-1 surge suppressor increases opening time by a factor of 2 to 3. Magnet System Characteristics for DC Operated Contactors Contactor types: Rated control circuit voltage U c V DC 12... 240 Coil operating limits acc. to IEC 60947-4-1 0.85... 1.1 x U c (at θ 60 C) ; U c (at θ 70 C) Drop-out voltage in % of U c approx. 10... 40 % Coil consumption Average pull-in value W 3 Average holding value W 3 Coil time constant open L/R ms 12 closed L/R ms 40 Operating time between coil energization and: N.O. contact closing ms 36... 59 N.C. contact opening ms 31... 53 between coil de-energization and: N.O. contact opening ms 13... 17 (2) N.C. contact closing ms 15... 20 (2) (2) The use of RT5 surge suppressor increases opening time by a factor of 1.1 to 1.2. 24

Connecting Characteristics M3 with cable clamp Delivered in open position. Screws of unused terminals must be tightened. Connecting capacity (min.... max.) Main conductors (poles) Rigid solid 1 x mm² 0.75... 4 0.75... 2.5 2 x mm² 0.75... 4 0.75... 2.5 Flexible with noninsulated 1 x mm² 0.75... 2.5 0.75... 2.5 Flexible with insulated 1 x mm² 0.75... 2.5 0.75... 1.5 2 x mm² 0.75... 1.5 0.75... 1.5 Bars and lugs L mm 7.7 - l L l mm > 3.2 - Capacity acc. to UL/CSA 1 or 2 x AWG 18-12 18-12 Auxiliary conductors (built-in auxiliary terminals + coil terminals) Rigid solid 1 x mm² 0.75... 2.5 0.75... 2.5 Flexible with noninsulated 1 x mm² 0.75... 2.5 0.75... 2.5 Flexible with insulated 1 x mm² 0.75... 2.5 0.75... 1.5 2 x mm² 0.75... 1.5 0.75... 1.5 Bars and lugs L mm 7.7 - l L l mm > 3.2 - Capacity acc. to UL/CSA 1 or 2 x AWG 18-14 18-14 Degree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 IP 20 IP 20 Screwdriver type Flat Ø 6.5 / Pozidriv 2 Flat Ø 3.5 Stripping length mm 9 10 Tightening torque All terminals recommended Nm / lb.in 1.00 / 9 - max. Nm 1.20-25