Film Capacitors Power Factor Correction

Similar documents
Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction

Power over Ethernet Transformers 60 W series

3 line filters for converters and power electronics

Film Capacitors AC Capacitors Application note

EMC filters. 4-line filters for installations and systems Rated current 6 to 125 A. Date: January 2006

SAW components. SAW RF filter. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Base stations LTE band 27. Date: October 31, 2016 Version: 2.

Power Factor Correction Power Quality Solutions

Power Factor Correction Power Quality Solutions

KRF EMC Filters Installation, Operation and Maintenance Manual

POWER FACTOR CORRECTION

MIKRO POWER FACTOR CORRECTION COMPONENTS

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Filters for Power Lines (Low Leakage Current)

Surface Mount Multilayer Ceramic Capacitors for RF Power Applications

Surface Mount Multilayer Ceramic Capacitors for RF Power Applications

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Surface Mount Multilayer Ceramic Chip Capacitors for High Temperatures 200 C

Surface Mount Multilayer Ceramic Chip Capacitors for High Frequency

LED Driver Compact fixed output

LED control gear Compact fixed output

LED Driver Linear / area fixed output

LED MODULES READYLINE DL

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Capacitors and banks 50 Hz 0 400/415 V network voltage

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

LED Driver Compact fixed output

AS09..S 3-pole Contactors - Spring Terminals

02/11/2015

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

LED Driver Compact dimming

MILLITARY SPECIFICATION SHEET

3M Sensored Termination (15 kv) QX-T15I-vi1-E

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

TRISHALA ELECTROLYTICS PVT LTD BANGALORE

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Technical Information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Recommended Land Pattern: [mm]

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

Installation Guide VL-MV10. Model No.

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Model Number Structure

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Recommended Land Pattern: [mm]

TRF STEP-DOWN TRANSFORMER USER MANUAL

R.2. Power capacitors, LV. Power factor correction and harmonic filtering. Homepage : Circutor-NRW Büro Köln

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Power Injector 1520 Series

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

llen-bradley 194R-HM4-NFPA3

Indoor Linear 80W Driver SI-C215280N2KR

Type: DILM25 10(24V50HZ) Article No.:

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

AC Line Rated Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

CAMTO LTD. Arc detecting system DC/AC

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

LED Driver Compact fixed output

Kuhnke Technical Data. Contact Details

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

SQM40/41 Actuators for air and gas dampers

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Jul03 Rev C EC

Series CT7N Bimetallic Overload Relays

Datasheet - SRB301LC 24VAC/DC

Photovoltaic Module Installation Manual (IEC)

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Modular Power System acc. VG MoFess Module for Military Ground Vehicles

Price List. AC-mfd Capacitors.

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Datasheet - SRB-E-201ST

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Type: DILM12 10(24VDC) Article No.:

Phono Amplifier brinkmann «EDISON» Manual.

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

PERFORMANCE SPECIFICATION SHEET

Transcription:

Series/Type: Ordering code: Date: November 2010 Version: 4 entered in headers and footers! Please fill in the Film Capacitors Power Factor Correction Identification/Classification 2 (header 2 + bottom left header bar): Ordering code: (top right header bar) Series/Type: (top right header bar) Preliminary data (optional): (if necessary) FILM PFC PM EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company.

Construction Dielectric: Polypropylene film Internally insulated, no grounding required Soft polyurethane resin, non PCB (NPCB) Aluminum can Features Self-healing properties Low dissipation factor Overpressure disconnection device High insulation resistance Typical applications Residential power factor correction unit Mounting Threaded stud at bottom of can (max. torque for M12 = 10 Nm) Product composition Cable Plastic terminal protection cover Capacitor file 106388 Cable Cross section: 1.5 mm 2 (14AWG) Length: 300 mm Rated voltage: 600 V AC Operation temperature: +105 ºC Material: Electrolytic copper with PVC insulation Please read Cautions and warnings and Page 2 of 10

Technical data and specifications Characteristics Rated capacitance C N According to dimension table, 5 to 33 µf Tolerance 5 / +10% Connection Cables Rated voltage V R 400 V (application voltage 127 400 V) Rated frequency f N Output 50 Hz / 60 Hz According to dimension table 0.02 1.66 kvar Rated current I R tan δ 0 (dielectric) According to power rating 0.5 W / kvar Maximum ratings V max (up to 8 h daily) V max (up to 1 min) I max I S 1.1 VR 1-3 VR 1.3 IR (A) 100 I R (A) Test data V TT 2.15 x V R, 60 s (type test) V TC *tan δ (120 Hz) at 20 C 1.0 x 10-3 * Without discharge resistor 3000 V AC / 50 Hz during 60 s Design data Dimensions (d x h) Weight approx Impregnation Fixing Max. torque (Al can stud) Mounting position d1: 42.5 ± 1 mm h: see product table L1: 10 ± 1 mm L2: 58 ± 1 mm L3: 50 ± 5 mm L4: 10 ± 2 mm See product table Non PCB, soft polyurethane resin Al can stud or bracket 4 Nm Any mounting position possible Please read Cautions and warnings and Page 3 of 10

Mean life expectancy t LD up to 100 000 hours Max. 5000 switchings per year acc. to IEC 60831 Terminals Protection degree IP53, indoor mounting Terminal cross section 16 mm 2 Maximum terminal current Creepage distance (min) Clearance (min) 15 A 12.7 mm 9.5 mm Safety Mechanical safety Max. short circuit current Overpressure disconnector (AFC: 10 ka) Climatic category 25/D min 25 ºC max +55 ºC Storage temperature 40 ºC.+85 ºC Humidity av. rel. < 65% Maximum altitude 4 000 m above sea level Degree of protection IP 20 Reference standards IEC 60831 1/2, UL 810-5th edition Discharge resistors are available upon request. Discharge resistor time according to IEC specification for specific types. Please read Cautions and warnings and Page 4 of 10

C R 400 V AC kvar 240 V AC kvar 230 V AC kvar 220 V AC kvar 127 V AC kvar Dimensions d x h μf 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz mm kg Weight Ordering Code * 5 0.25 0.30 0.09 0.11 0.08 0.10 0.08 0.09 0.025 0.030 40 x 70 0.15 B32340C4056J000 7 0.35 0.42 0.13 0.15 0.12 0.14 0.11 0.13 0.04 0.04 40 x 70 0.15 B32340C4076J000 10 0.50 0.60 0.18 0.22 0.17 0.20 0.15 0.18 0.05 0.06 40 x 70 0.15 B32340C4106J000 15 0.75 0.90 0.27 0.33 0.25 0.30 0.23 0.27 0.08 0.09 40 x 80 0.16 B32340C4156J000 20 1.00 1.21 0.36 0.43 0.33 0.40 0.30 0.36 0.10 0.12 40 x 105 0.18 B32340C4206J000 25 1.25 1.51 0.45 0.54 0.42 0.50 0.38 0.46 0.13 0.15 40 x 105 0.18 B32340C4256J000 30 1.50 1.81 0.54 0.65 0.50 0.60 0.46 0.55 0.15 0.18 40 x 125 0.20 B32340C4306J000 33 1.66 1.99 0.60 0.72 0.55 0.66 0.50 0.60 0.17 0.20 40 x 125 0.20 B32340C4336J000 *)Types of products range by code identity. Without studs in the aluminum can, cable length 300 mm: Jxx0. Without studs in the aluminum can, aluminum can with PVC cover 180 um thickness, cable length 300 mm: Jxx1. Without studs in the aluminum can, cable length 500 mm: Jxx2. Without studs in the aluminum can, aluminum can with PVC cover 180 um thickness, cable length 500 mm: Jxx3. With studs in the aluminum can, cable length 300 mm: Jxx4. With studs in the aluminum can, aluminum can with PVC cover 180 um thickness, cable length 300 mm: Jxx5. With studs in the aluminum can, cable length 500 mm: Jxx6. With studs in the aluminum can, aluminum can with PVC cover 180 um thickness, cable length 500 mm: Jxx7. Please read Cautions and warnings and Page 5 of 10

Please read Cautions and warnings and Page 6 of 10

Cautions and warnings In case of dents of more than 1 mm depth or any other mechanical damage, capacitors must not be used at all. In case of oil leakages, capacitors must not be used at all. To ensure the full functionality of the overpressure disconnector, elastic elements must not be hindered and a minimum space of 12 mm has to be kept above each capacitor. Do not handle the capacitor before it is discharged. Resonance cases must be avoided by appropriate application design in any case. Handle capacitors carefully, because they may still be charged even after disconnection due to faulty discharging devices. Protect the capacitor properly against overcurrent and short circuit. Failure to follow cautions may result, worst case, in premature failures, bursting or fire. Discharging Capacitors must be discharged to a maximum of 10% of rated voltage before they are switched on again. This prevents an electric impulse discharge in the application, influences the capacitor s service life, and protects against electric shock. Service life expectancy Electrical components do not have an unlimited service life expectancy; this applies to self-healing capacitors, too. The maximum service life expectancy may vary depending on the application the capacitor is used in. Safety Electrical or mechanical misapplication of capacitors may be hazardous. Personal injury or property damage may result in bursting of the capacitor or in expulsion of oil or melted material due to mechanical disruption of the capacitor. Ensure good, effective grounding for capacitor enclosures. Provide means of disconnecting and insulating a faulty component/bank. The terminals of capacitors, connected bus bars and cables as well as other devices may also be energized. Follow good engineering practice. Thermal load/over-temperature After installation of the capacitor, it is necessary to verify that maximum hot-spot temperature is not exceeded at extreme service conditions. Please read Cautions and warnings and Page 7 of 10

Overpressure disconnector To ensure full functionality of an overpressure disconnector, the following must be observed: 1. The elastic elements must not be hindered, i.e. Connecting lines must be flexible leads (cables). There must be sufficient space (min. 12 mm) for expansion above the connections. This will enable a longitudinal extension of the can to secure the overpressure disconnector work. Folding beads must not be retained by clamps. 2. The maximum allowed fault current of 10000 A in accordance with UL 810 standard must be assured by the application. 3. Stress parameters of the capacitor must be within the IEC60831 specification. Overcurrent and short circuit protection Use HRC fuses or MCCBs for short circuit protection. Short circuit protection and connecting cables should be selected so that 1.5 times the rated capacitor current can be permanently handled. HRC fuses do not protect a capacitor against overload they are only for short circuit protection. The HRC fuse rating should be 1.6 to 1.8 times rated capacitor current. Do not use HRC fuses to switch capacitors (risk of arcing). Use thermal magnetic over current relays for overload protection. Resonance cases Resonance cases must be avoided by appropriate application design in any case. Maximum total RMS capacitor current (incl. fundamental harmonic current) specified in technical data must not be exceeded. Re-switching vs. phase-opposition In case of voltage interruption, a sufficient discharge time has to be ensured to avoid phaseopposition and resulting high inrush currents. Vibration resistance The resistance to vibration of capacitors corresponds to IEC 68, part 2 6. Max. test conditions: Test duration 6 h* Frequency range 1 10... 55 Hz* Displacement amplitude 0.75 mm* *corresponding to max. 98.1 m/s or 10 g Please read Cautions and warnings and Page 8 of 10

These figures apply to the capacitor alone. Because the fixing and the terminals may influence the vibration properties, it is necessary to check stability when a capacitor is built in and exposed to vibration. Irrespective of this, you are advised not to locate capacitors where vibration amplitude reaches the maximum in strongly vibrating equipment. Mechanical protection The capacitor has to be installed in a way that mechanical damages and dents in the aluminum can are avoided. Grounding The threaded bottom stud of the capacitor has to be used for grounding. In case grounding is done via metal chassis that the capacitor is mounted to, the layer of varnish beneath the washer and nut should be removed. The maximum tightening torque is 4 Nm. Maintenance In case of current above the nominal current, check your application for modifications. If a significant increase in the amount of non-linear loads has been detected, then a consultant has to be called in for a harmonic study. Check the temperature of capacitors directly after operation for a longer period, but make sure that the capacitors have been switched off. In case of excessive temperature of individual capacitors, it is recommended to replace these capacitors, as this should be an indication for loss factor increase, which is a sign for reaching end of life. Storage and operating conditions Do not use or store capacitors in corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like are present. In dusty environments, regular maintenance and cleaning especially of the terminals is required to avoid conductive path between phases and/or phases and ground. Please read Cautions and warnings and Page 9 of 10

Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the General Terms of Delivery for Products and Services in the Electrical Industry published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, MiniBlue, MiniCell, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 10 of 10