Dohse Aquaristik GmbH & Co. KG

Similar documents
Operating Manual. Basic Control BC16. two-channel for eco moon

EC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

TVAC20000 User manual

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

USER MANUAL Full HD Widescreen LED Monitor L215ADS

USER MANUAL Full HD Widescreen LED Monitor L215IPS

ST-4000 SIGNAL LEVEL METER

USER MANUAL Full HD Widescreen LED Monitor L236VA

ST-4000D SIGNAL LEVEL METER

Operating instructions. Universal timer switch display

Smart Control SC16 3-Channel for matrix

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

Tube Roller Shakers. User Guide. Version 1.2

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

HD-CM HORIZON DIGITAL CABLE METER

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Tube Rotator. User Guide. Version 1.2

Advanced Digital Melting Point Apparatus

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2

3G/HD/SD-SDI to HDMI Converter

Magnetic Field Generator 1000

Product Identification

KHT 1000C HV-Probe Calibrator. Instruction Manual

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

INSTRUCTIONS FOR USE Pro-Ject Receiver Box S

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Spectra Batten (Order code: LEDJ95)

19 / 20.1 / 22 WIDE SCREEN TFT-LCD MONITOR

QLOCKTWO CLASSIC. Instructions for use

Sevenlogic Comfort Timer Switch

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Operating Instructions

MT03A Electronic converter for flow rate transmitters

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

PLL2210MW LED Monitor

Electronic converter for level transmitters MT03L Instructions manual

PL2410W LCD Monitor USER'S GUIDE.

17" & 19" Color TFT LCD Monitor

Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown then fax: 44 (0)

OPERATING AND SAFETY INSTRUCTIONS for DIGITAL TEMPERATURE CONTROLS (PLSM SERIES)

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

PR FESSIONAL PROFESSIONAL TERRESTICAL FM-FM PTFF Grundig SAT Systems

Programmable Room Thermostat With RF

DC162 Digital Visualizer. User Manual. English - 1

USER MANUAL. VP-501N UXGA Scan Converter MODEL: P/N: Rev 5

2.0 Wall Mount TV Soundbar Instruction Manual

FOOT CONTROLLER USER S GUIDE

DPM 942-FPSI 4-20mA Loop Meter with Programmable Backlighting

HD/SD-SDI Pattern Generator

Fusion 120 Zoom. User Manual. Order code: EQLED068

8 Port HD/SD-SDI Switch

Subwoofers ENGLISH FRANCAIS SPANISH DEUTSCH OWNER S MANUEL MODE D EMPLOI MANUEL DEL USUARIO BEDIENUNGSANLEITUNG

USER MANUAL Model: A5

EVD-L04/100A1-960, EVD-L08/200A1-960 and. EVD-L16/400A1-960 DVRs. Quick Operation Guide

Winmate Communication INC.

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

Professional 4-channel Thermocouple Thermometer plus Infrared Thermometer

Colour Control48 Order Code: Control48

Operating Instructions. Room temperature controller with clock

Assembly. Front view. LEDs. Parametrization interface. Power Bus

GESTRA Steam Systems NRR 2-50 NRR English. Installation & Operating Manual Level Controller NRR 2-50 Level Controller NRR 2-51

INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING:

M2CBRIDGE COMPANY LLC

VGA to DVI Extender over Fiber SET

Made for LEDs. Quick Start. Version 1.3 Software

KACO-display. Wireless Solar Monitoring System. Operating Instructions KACO-display. full of energy...

LIGHT AIR SWITCH. User Manual and Troubleshooting Guide WIRELESS LIGHTING MODULE ACKNOWLEDGEMENTS SAFETY WARNINGS EQUIPMENT DESCRIPTION

Controller DMX DC-1224

8 Port HD/SD-SDI Video Switch with 2 Port Splitter

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

Single cable multiswich programmer PC102W

of Switzerland of Switzerland Re:source FM Tuner Module Dominating Entertainment. Revox of Switzerland.

DMX192S Controller INSTRUCTION MANUAL. Ref. nr.: V2.1

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

User Guide Stand-Alone Metering for OptiPlant

Contents Introduction Safety Cleaning Connections Cartridge gain and loading Technical specification Fig.1 PS.30R/ PS.30RDT rear panel Fig.

This document courtesy of:

DLP200M 2 Relay Module for Heating and Cooling Plants

UC1000 Universal Controller

Broadcaster Instruction Manual

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

Controller, Scheduler-Timer Model UCS-01. User Guide


M2 Instruction Manual

DMX OPERATOR PRO. User Manual

TriLIN Program Utility TPU_ TriLIN Programming Manual

Transcription:

A trademake of Dohse Aquaristik Instructions for use ph-control eco Item nr. 43000 Dohse Aquaristik GmbH & Co. KG www.dohse-aquaristik.com

1. Introduction 1. Introduction... 3 1.1 Display 1.2 Safety instructions 2. Description of the Basic Functions... 4 2.1 Function monitoring of external devices 2.2 Safety shutdown during programming 2.3 Safeguard function 2.4 Return function 2.5 Malfunction display 3. Description of the Programmable Functions... 4 3.1 Clock programming 3.2 ph Set Point 3.3 CO ² -Night off function 3.4 ph Alarm 3.5 ph Electrode Calibration 3.6 Calibration Reminder 4. Quick Start Guide to Programming... 6 5. Programming Instructions... 7 5.1 Clock programming 5.2 ph Set Point programming 5.3 CO ² -Night off function (de)acitvation 5.4 ph Alarm programming 5.5 ph Electrode Calibration 5.6 Calibration Reminder (de)acitvation 6. Reset... 13 7. Factory Presetting... 13 8. Source of Fault... 13 9. Technical Specifications... 14 10. EC Declaration of Conformity... 14 2

1. Introduction 1.1 Display = Numeric display = Time in hours = Time in minutes = ph value = Night programming active = CO ² supply to aquarium active + = ph alarm + = Calibration memory = Activation or deactivation of functions = CLOCK (displayed, when starting the real time programming) = Calibration (displayed, when starting the calibration or calibration alarm programming) = Night (displayed, when starting the night off function programming) 1.2 Safety instructions The HOBBY ph-control eco is designed exclusivly for use in enclosed rooms. All electronic components of the device must only be operated whilst they are free from defects. Should product be damaged, please return to your dealer for repair. Continued operation of the device may cause fatal injury from an electric shock. Ensure that the HOBBY ph-control eco can not come into contact with water. This technical products must only be operated as supplied. Electronic components must not be modified in any way. Housing must not be opened. If the product is damaged cease useage or shut down immediatly by pulling from mains. 3

2. Description of the Basic Functions 2.1 Function monitoring of external devices The housing is fitted with an LED. In operating mode this indicates the active control of the external device. 2.2 Safety shutdown during programming When entering into programming mode, the slot is deactivated for safety reasons. 2.3 Safeguard function To protect electronic components, a delay of 60 seconds is set between 2 switching states before the slot becomes active again. 2.4 Return function The HOBBY ph-control eco automatically returns to operating mode when no button is pressed for a period of 90 seconds while in programming mode. 2.5 Malfunction displaying In case of an ph-electrode defect is displayed. 3. Description of the Programmable Functions In programming mode, the functions can be configured in the following sequence. 3.1 Clock programming The HOBBY ph-control eco has a built-in real-time clock. The factory presets the time at. The time setting is cleared during a resetting procedure. 4

3.2 ph Set Point The ph set point can be adjusted within the limits of 4.0-9.9. If the measured ph value is outside the display range, values lower than 4.0 are displayed as LO, values higher than 9.9 are displayed as HI. Outside of these limits, the ph channel is switched off. The ph-controlled CO ² fertilisation is carried out through permanent measuring by a connected ph electrode and switching of a connected CO ² magnetic valve with a switch hysteresis (the difference between the switching point and the triggering point) of 0.1 and a control accuracy is +/- 0.1. The switch hystereris is ph 0.1, the control accuracy is +/- 0.1 (reference value). Please note: If no ph electrode is connected to the Dupla ph-control pro, so that the BNC socket is open, fictitious ph values will be displayed. 3.3 CO ² -Night off function This enables to stop supplying CO ², controlled by a magnetic valve, into your aquarium during the night if desired. 3.4 ph Alarm When the programmed ph set-point is either not met or exceeded, the flashing LED light indicates an alarm. The alarm window can be set between 0.1 and 4.0 deviation from the set point. By default, a deviation of ph 0.5 is preset. The alarm function can be disabled by setting 0.0. 3.5 ph Electrode Calibration The factory setting of the calibration points are ph 7, ph 4 and ph 9, the calibration sequence first is ph 7, then ph 4 or alternatively ph 9. The calibration process can be cancelled by pressing the and button simultaneously. 3.6 Reminder of Calibration Function With this feature enabled, every six-weeks the LED light and on the display 5

flashes as a reminder to check the ph electrode calibration. If you prefer not to carry out a calibration, the memory display clears after activating any button and reappears in another 6 weeks. 4. Quick Start Guide to Programming Single mode (manufacturer presetting): Optionally either ph value or current time are displayed continuously Toggle mode: ph-value and current time are displayed alternately in a 3 second rhythm. Changing between toggle and single mode: Press the button while in operation mode. Switching to programming mode: A) Pressing the main programming menu. button enters the Moving within the menu structure: B) With the or buttons you can scroll through the menu items. Modifying programming: C) Pressing enables the modification of programmed values, the changeable value flashes. D) Increase or decrease required values with the or button. E) Acknowledge by activating the button. Quitting the programming mode: F) After 90 seconds of inactivity you automatically access the operational mode. From the main level you can access the operational mode as well by holding down the button for 3 seconds. All changed values will be saved. Cancelation of programming: By pressing the and button simultaneously it is possible to quit the programming mode at any time without saving. 6

Manual activation / deactivation: The slot can be turned on and off manually. To activate hold, then press. Press these buttons a second time to deactivate. If you press a third time, program mode is reactivated. Please note: You will find a graphical quick start guide here: www.dohse-aquaristik.de/pdf/gebrauchsanweisungen/43000_ph-control_eco_kurzanleitung_gb.pdf 5. Programming Instructions Connect the ph electrode to the HOBBY ph-control eco. To start the programming mode press button Please note: Without connected ph-elctrode the error displayed. will be 5.1 Clock programming Entering the programming mode, flashes. Press the button, the hours digits flashes Use the and buttons to set the hours between 0 and 23. Press the button, the minutes digits flashes. Use the and buttons to set the minutes between 0 and 59. Acknowledge with the button. When finished, will flash again. Scroll to the next main menu item with the button, then press the button. 7

Please note: Once the clock has been set, you can use or to directly access the other settings. Attention: The HOBBY ph-control eco does not automatically switch between summer time and winter time. This change must be entered manually. 5.2 ph Set Point Programming When flashing was acknowledged with, or your last set value flashes. Set the required value with the or button, then acknowledge with the button. Please note: ph Set Point presetting is 7.00. Depending of water values from where your fishes come, higher or lower values could be required. When finished, will flash again. Scroll to the next main menu item with the button, then press the button. 5.3 CO ² -Night off function (de)activation When and are flashing and you want to supply CO ² to your aquarium in the night, scroll with button to next main menu item and acknowledge by pressing. 8

When flashing and was acknowledged with, flashes.if you do not want to supply CO ² to your aquarium in the night, press or button to change to and acknowledge by pressing. Presetting value or your last programmed value flashes in the display. Set the desired start of night time in hours with the or button, then acknowledge with. Presetting value or your last programmed value flashes in the display. Set the desired start of night time in minutes with the or button, then acknowledge with. Caution: Here (displayed right down site) is the time when the stop of CO ² supply should beginn, for example at when your lighting is switched off. Presetting value or your last programmed value flashes in the display. Set the desired end of night time in hours with the or button, then acknowledge with. Presetting value or your last programmed value flashes in the display. Set the desired end of night time in minutes with the or button, then acknowledge with. Caution: Here (displayed right down site) is the time when the stop of CO ² supply should end, for example at when your lighting is switched on. Please note: When the night off beginning time is reached the display shows a measured but not regulated ph value. Left below and right below is displayed. When finished, will flash again. Scroll to the next main menu item with the button, then press the button. 9

5.4 ph alarm programming When flashing and was acknowledged with, flashes. Use the and buttons to set the +/- alarm between 0.5 and 4.0. Acknowledge with button. Advice: means that no alarm is set. When finished, and will flash again. Scroll to the next main menu item with the button, then press the button. 5.5 ph Electrode Calibration When flashing was acknowledged with,. To calibrate the ph Electrode go on as described: 1. Remove the protective cap from the electrode tip. 2. Rinse electrode tip briefly with destilled water. 3. Dip the electrode into the ph 7 solution and press. Then a measured running value is displayed. 10

When this value has settled, press the button for three seconds until the LED light flashes one time as confirmation of acceptance. Then is displayed for one second. 4. flashes. Take the elctrode out of the ph 7 solution and press to proceed calibration. 5. Rinse the electrode tip briefly with destilled water. 6. To calibrate the ph Electrode for freshwater aquaria, dip the electrode into the ph 4 solution for freshwater and acknowledge with. (To calibrate the ph Electrode for saltwater aquaria, use the or button until flashes, dip the electrode into the ph 9 solution for saltwater and acknowledge with.) Then a measured running value is displayed. 7. When this value has settled, press the button for three seconds until the LED light flashes one time as confirmation of acceptance. The calibration is finished. 8. Rinse the electrode tip briefly with HOBBYdest. 9. Fix the electrode in the aquarium with suction cups. Please note: The calibration can be interrupted at any time by pressing the or button at the same time. Caution: Used electrodes which top has been dried completly in the protection cover need to be put in water over night before the calibration is done. New electrodes need a 14 days run-in period. After that a second calibration is necessary for precise mesurement. When finished,, and are flashing. 11

Please note: Normally you would expect to flash again. Exceptionally here it does not. In case of pressing by mistake you would delete your just finished calibration and start again. So for safety reason after calibration is finished you directly access the calibration reminder function. 5.6 Calibration Reminder (de)activation The factory presetting is an activated visual calibration reminder alarm. If you want to keep it, press for 3 seconds while, and are flashing. You return to operating mode. To deactivate the reminder press briefly while, and are flashing. Use the and buttons to change into and acknowledge with. When finished,, and will flash again. If you want to finish programming, press and hold the display returns to operating mode. for 3 seconds until 12

6. Reset Should your HOBBY ph-control eco not function correctly, please perform a reset: 1. Unplug from mains 2. Plug the mains plug back in while keeping the button pressed 3. Release the button Please note: All programmed settings, except those for the clock, are lost. The HOBBY ph-control eco will regulate with factory s presettings. 7. Factory Presetting After the event of a power failure, the HOBBY ph-control eco starts with the factory presetting again. Clock setting: 12:00 Single / toggle mode: Single mode ph point: 7.0 ph Alarm: OFF (0.0 means no alarm ) ph calibration memory function: ON CO ² -Night off function: Off (CO ² is supplied during the night) 8. Source of Fault In the case of a problem, first reset to the factory settings. If this does not solve the problem, please search for the fault in the following table: 13

Replace ph electrode Possible cause Solution is displayed ph electrode defect Replace ph electrode Fluctuating ph value ph electrode cable too close to a mains cable or a CO ² reactor Re-locate ph electrode cable In the event of a warranty or repair issue, please return to the place of purchase. 9. Technical Specifications Operating voltage: 230 V, 50 Hz Load capacity: Max. 2,000 W (ohmic load) ph control range: 4.0 9.9 ph control accuracy: +/- 0.1 (reference value) ph switch hystereris: 0.1 (the difference between the on and off switching point) ph alarm range: +/- 0.1 4.0 adjustable in 0.1 ph increments ph calibration memory: Six-week BNC Adaptor cable length: 20 cm 10. EC Declaration of Conformity The manufacturer declares that the devices comply with the requirements of the relevant EMC and LVD standards and are therefore in conformity with EC directives 2004/108/EC and 2006/95/EC. 14

A trademake of Dohse Aquaristik Flora Fit Adds to the aquarium water all the micro- and macronutrients required for optimum plant growth without encouraging algae growth at the same time. Flora Fit contains iron, potassium, manganese and molybdenum, as well as other elements. These are multiple-stabilised and are absorbed directly through the leaves. Flora Fit can be used for weekly fertilization and as a daily fertilizer. Free of nitrates and phosphates. 100 ml / 250 ml / 500ml Item nr. 41030 / 41035 / 41040 Dohse Aquaristik GmbH & Co. KG www.dohse-aquaristik.com 15

Dohse Aquaristik GmbH & Co. KG Otto-Hahn-Str. 9 D-53501 Gelsdorf Telefon: +49 (0)22 25-94 15 0 Fax: +49 (0)22 25-94 64 94 E-Mail: info@dohse-aquaristik.de Internet: www.dohse-aquaristik.de HOBBY Aquaristik Hobby Terraristik Dupla DuplaMarin