Amplifier Measurement Wizard Operation Manual

Similar documents
Mixer Measurement Wizard Operation Manual

Basic RF Amplifier Measurements using the R&S ZNB Vector Network Analyzer and SMARTerCal. Application Note

Agilent MOI for HDMI 1.4b Cable Assembly Test Revision Jul 2012

Keysight Technologies High Power Ampliier Measurements Using Nonlinear Vector Network Analyzer. Application Note

USB-TG124A Tracking Generator User Manual

Keysight Method of Implementation (MOI) for VESA DisplayPort (DP) Standard Version 1.3 Cable-Connector Compliance Tests Using E5071C ENA Option TDR

Procedures to Characterize Maury s Automatic Tuner Using ATS Software Version 5.1 or above

Keysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer. Application Note

Keysight Technologies Method of Implementation (MOI) for BroadR-Reach Link Segment Tests Using E5071C ENA Option TDR

Wireless Studio. User s Guide Version 5.1x Before using this software, please read this manual thoroughly and retain it for future reference.

De-embedding Gigaprobes Using Time Domain Gating with the LeCroy SPARQ

DATASHEET ISL Features. Ordering Information. Applications. Typical Application Circuit. MMIC Silicon Bipolar Broadband Amplifier

Why Engineers Ignore Cable Loss

Practical De-embedding for Gigabit fixture. Ben Chia Senior Signal Integrity Consultant 5/17/2011

IMPORTANT NOTICE. Company name - STMicroelectronics NV is replaced with ST-NXP Wireless.

RF Level Test System +20 dbm to 130 dbm

Agilent Technologies. N5106A PXB MIMO Receiver Tester. Error Messages. Agilent Technologies

Application Note No. 146

Extension kit for R&S Vector Network Analysers

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

Yellow Frog. Manual Version 1.1

DATASHEET ISL Features. Applications. Ordering Information. Typical Application Circuit. MMIC Silicon Bipolar Broadband Amplifier

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

The high-end network analyzers from Rohde & Schwarz now include an option for pulse profile measurements plus, the new R&S ZVA 40 covers the

Agilent 8720E Family Microwave Vector Network Analyzers

Agilent FieldFox RF Analyzer N9912A

GaAs, MMIC Fundamental Mixer, 2.5 GHz to 7.0 GHz HMC557A

Application Note DT-AN DTU-315 Verification of Specifications

R&S FS-Z60/75/90/110 Harmonic Mixers for the R&S FSP/FSU/ FSQ/FSUP/FSV

STEVAL-IKR001V7D. Sub Ghz transceiver daughterboard with power amplifier based on the SPIRIT1. Features. Description

STEVAL-CCM003V1. Graphic panel with ZigBee features based on the STM32 and SPZBE260 module. Features. Description

QPC6222SR GENERAL PURPOSE DPDT TRANSFER SWITCH. Product Overview. Key Features. Functional Block Diagram. Applications. Ordering Information

R&S ZVB Vector Network Analyzer High measurement speed up to 20 GHz with two or four test ports

Auro 11.1 update for ICMP. Installation manual

ME1000 RF Circuit Design. Lab 10. Mixer Characterization using Spectrum Analyzer (SA)

R&S ZND Vector Network Analyzer Specifications

GTT LTE RRU ADD- ON USER GUIDE

Application Note AN39

RF Characterization Report

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Mainline Pin (plug) Connector Return Loss

Crestron Room Scheduling Panels. User Guide Crestron Electronics, Inc.

Keysight FieldFox Microwave Analyzers

ATA8520D Production and EOL Testing. Features. Description ATAN0136 APPLICATION NOTE

Vector Network Analyzers

QPL GHz GaN LNA

Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note

Application Note DT-AN-2115B-1. DTA-2115B Verification of Specifations

TGP2109-SM GHz 6-Bit Digital Phase Shifter. Product Description. Functional Block Diagram. Product Features. Applications. Ordering Information

U SER S G UIDE. TS2002A Fiber Optic Test Kit

Obsolete Product(s) - Obsolete Product(s)

RF Semiconductor Test AXRF RF Port Upgrade Kits

Mid Frequency Antennas Comparison in GaiaSpectrum Standard

R&S ZNBT Vector Network Analyzer Specifications

Keysight Technologies De-Embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer. Application Note

HMC412BMS8GE MIXER - SINGLE & DOUBLE BALANCED - SMT. Typical Applications. Features. Functional Diagram. General Description

AMIS LIN Transceiver Application Note EMC Conducted Susceptibility, IEC , Direct Power Injection

DEMO MANUAL DC2668A LTC5552 3GHz to 20GHz Microwave Mixer with Wideband DC to 6GHz IF BOARD PHOTO

N5264A. New. PNA-X Measurement Receiver. Jim Puri Applications Specialist March Rev. Jan Page 1

STEVAL-TDR007V1. 3 stage RF power amplifier demonstration board using: PD57002-E, PD57018-E, 2 x PD57060-E. Features. Description

Obsolete Product(s) - Obsolete Product(s)

R&S ZNBT Vector Network Analyzer Network analysis with up to 24 test ports

Agilent CSA Spectrum Analyzer N1996A

MaxView Cinema Kit Quick Install Guide

Keysight PXA Signal Analyzer

STANC0. Stereo HD-PA digitally programmable active noise cancelling audio engine. Features. System. Input and output.

GT Dual-Row Nano Vertical SMT High Speed Characterization Report For Differential Data Applications

General purpose low noise wideband amplifier for frequencies between DC and 2.2 GHz

EAN-Performance and Latency

JD725A Cable and Antenna Analyzer - Dual Port

Features. Parameter Min. Typ. Max. Units

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5

Parameter Symbol Units MIN MAX. RF Input power (CW) Pin dbm +23

R&S ZND Vector Network Analyzer Basic, solid-performance network analysis

ENGINEERING COMMITTEE

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

Agilent M9330A Series PXI-H Arbitrary Waveform Generator

ARRIS Solutions Inc. TERMS OF USE ARRIS SOFTWARE APPLICATIONS

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

1.5 GHz to 4.5 GHz, GaAs, MMIC, Double Balanced Mixer HMC213BMS8E

Agilent Migration from 8712/8714 Series to ENA-L Network Analyzers

PiMPro Rack Mount Analyzer

STEVAL-ICB004V1. Advanced resistive touchscreen controller demonstration board based on the STMPE811. Features. Description

HIGH-LINEARITY TRIPLE-BALANCED MIXERS T3-0838

General purpose low noise wideband amplifier for frequencies between DC and 2.2 GHz

Broadcast Television Measurements

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

Tech Note: How to measure additive phase noise of amplifiers using the 7000 Series

Certificate of Calibration

XviewerEYE Video and Waveform Viewer Feature

PiMPro Portable Analyzer PiMPro Classic 1821

Capstone screen shows live video with sync to force and velocity data. Try it! Download a FREE 60-day trial at pasco.com/capstone

PIM Master. Maintenance Manual

Q-Rex Absolute Quantification HID Plug-in User Manual

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1

RXT OSA Test Module

General purpose low noise wideband amplifier for frequencies between DC and 2.2 GHz

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

General purpose low noise wideband amplifier for frequencies between DC and 750 MHz

Transcription:

Agilent ENA Series Network Analyzers Amplifier Measurement Wizard Operation Manual Rev. 01.40 January 2011

Notices The information contained in this document is subject to change without notice. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Agilent Technologies. Microsoft, MS-DOS, Windows, Visual C++, Visual Basic, VBA and Excel are registered trademarks of Microsoft Corporation. Java is registered trademark of Sum Microsystems Corporation. Copyright 2009-2011 Agilent Technologies Sample Program The customer shall have the personal, non-transferable rights to use, copy, or modify SAMPLE PROGRAMS in this manual for the customer s internal operations. The customer shall use the SAMPLE PROGRAMS solely and exclusively for their own purpose and shall not license, lease, market, or distribute the SAMPLE PROGRAMS or modification of any part thereof. Agilent Technologies shall not be liable for the quality, performance, or behavior of the SAMPLE PROGRAMS. Agilent Technologies especially disclaims any responsibility for the operation of the SAMPLE PROGRAMS to be uninterrupted or error-free. The SAMPLE PROGRAMS are provided AS IS. AGILENT TECHNOLOGIES DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Agilent Technologies shall not be liable for any infringement of any patent, trademark, copyright, or other proprietary right by the SAMPLE PROGRAMS or their use. Agilent Technologies does not warrant that the SAMPLE PROGRAMS are free from infringements of such rights of third parties. However, Agilent Technologies will not knowingly infringe or deliver software that infringes the patent, trademark, copyright, or other proprietary right of a third party. 2

Overview of the program The ENA Amplifier Measurement Wizard VBA macro assists setting measurement conditions for amplifier tests.. Program Description Program title VBA File Name Revision Amplifier Measurement Wizard EnaAmplifierWizard_0140.vba Rev.01.40 Supported ENA models and firmware Models E5071C 2-port/4-port Firmware Rev.8.00 or later Required external instruments Power meter and power sensor (for harmonics and gain compression measurement) Measurements supported in the Wizard S-parameter measurements Harmonic measurements (ENA Opt 008 FOM is required) Gain compression measurements (CW / Swept) Starting VBA Program Step1. Copy VBA file to local drive of ENA. Step2. Press Macro Setup on the front panel. Step3. Press Load Project and load VBA file. Step4. Press Macro Run on the front panel. 3

VBA Procedure: Startup Dialogue The VBA starts with following dialogue. The measurement type can be selected with this dialog. The procedure of the wizard and measurement result for each measurement type is described below. (Note: If the measurement wizard dialogue gets behind the ENA application during the operation, press [Focus] hard key on ENA.) 4

VBA Procedure: S-parameter Measurements Introduction If you check K-factor-measurement check box, you can measure the K-factor as well as the S-parameters. By pressing the K-factor definition button, the definition of the K-factor is displayed. [step1/4] Stimulus Parameter Setup [step2/4] Calibration [step3/4] De-Embedding If there is an unwanted network between the DUT and the calibration plane, you can remove it with de-embedding feature. The touchstone file (*.s2p) should be prepared beforehand. If you don t need to do this, just press the Next button. 5

[step3/4] Connect Device and Measure Measurement result (Without K-factor) Measurement result (With K-factor) The K-factor measurement is performed every time after the sweep. The K-factor is drawn on the Ch2 by the VBA. 6

VBA Procedure: Harmonics Measurements Introduction [step1/3] Stimulus Parameter Setup The harmonics of the fundamental frequency can be set on this step. If the frequency for the measurement is not enough, the checkbox for the harmonics is disabled automatically. [step2/3] Calibration On harmonics measurement, the power calibration and the receiver calibration is required for the accurate measurement. As for the power calibration, you can choose either of Power Meter & Power Sensor or USB Power Sensor. The Receiver Calibration button is activated after the power calibration is performed. 7

[step3/3] Connect Device and Measure Measurement result On the ch1, absolute power [dbm] of fundamental frequency is displayed. Also, the VBA draws the absolute power [dbm] of each harmonics frequency on the Ch2-Ch5. On the Ch6, the VBA overlays the harmonics value compared to the fundamental power [dbc]. 8

VBA Procedure: Compression Measurements (CW) Introduction First off, you need to select CW frequency on this step. On the CW frequency, the ENA performs power sweep on single frequency, then calculate the P1dB. [step1/4] Stimulus parameter setup [step2/4] Calibration On P1dB measurement, the power calibration and the full-2port calibration is required for the accurate measurement. As for the power calibration, you can choose either of Power Meter & Power Sensor or USB Power Sensor. 9

[step3/4] De-Embedding If there is an unwanted network between the DUT and the calibration plane, you can remove it with de-embedding feature. The touchstone file (*.s2p) should be prepared beforehand. If you don t need to do this, just press the Next button. [step4/4] Connect Device and measure Measurement result You can choose either of input level or output level for the P1dB calculation. The input level simply shows the input power for the DUT (source power of the ENA) where the P1dB compression occurs. If you select the output level, it shows output power where the P1dB compression occurs. Note that the P1dB calculation uses marker on the Tr1, and the Tr1 should be activated when the VBA calculates the P1dB. If you change the active trace to Tr2, the VBA does not work properly. 10

VBA Procedure: Compression Measurements (Swept frequency) Introduction You need to select Swept frequency on this step. On the Swept frequency, the ENA performs power sweep on single frequency for each frequency point, then calculates the P1dB for each frequency, and then plots the frequency dependency of the P1dB. Introduction (Swept Frequency) [step1/4] Stimulus parameter setup [step2/4] Calibration On P1dB measurement, the power calibration and the full-2port calibration is required for the accurate measurement. As for the power calibration, you can choose either of Power Meter & Power Sensor or USB Power Sensor. 11

[step3/4] De-Embedding If there is an unwanted network between the DUT and the calibration plane, you can remove it with de-embedding feature. The touchstone file (*.s2p) should be prepared beforehand. If you don t need to do this, just press the Next button. [step4/4] Connect Device and measure Measurement result The Ch1 shows the power sweep for single frequency. The VBA program performs P1dB search on this measurement. On the Ch2, the VBA plots the input level [dbm] or output level [dbm] of the P1dB over the frequency. Same as the CW mode, the input level simply shows the input power for the DUT (source power of the ENA) where the P1dB compression occurs. If you select the output level, it shows output power where the P1dB compression occurs. 12

Revision History Revision Date Description 01.00 Mar 2008 Initial revision 01.01 Apr 2008 Modified frequency range check function 01.10 Oct 2008 Added 20GHz Option support 01.11 Mar 2009 Revised the image of the K-factor definition 01.20 Oct 2009 Added following features: - USB power sensor for power calibration - De-embedding wizard - P1dB power calculation on either input absolute power or output absolute power 01.30 July 2010 Added option TDR support 01.40 Jan 2011 Added the calibration kits: (85038A/F/M, 85054D, 85056D, 85056K, 85039B) 13