MXE " 3 Cell MXC "

Similar documents
WHAT IS MAXCELL 300% MORE CABLE 2X AS FAST CUTS TOTAL PROJECT COSTS

FIBER OPTIC CABLE PULLING

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

White Paper. Next Generation of Fiber Optic Loose Tube Cable. ABSTRACT INTRODUCTION. Stephen Martin, Product Line Manager, RCDD

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE

OCC Installation Figure 8 Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

GenSPEED 10 MTP Category 6A Cable An Unshielded 6A Cable with Superior Protection Against Alien Crosstalk

PREMIUM 5e F/UTP PRODUCTS

Tab 10 - The NESC and Underground Applications. Restricted Siemens Industry, Inc All rights reserved.

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

STRUCTURED CABLE SYSTEM (SCS)

Underground Installation of Optical Fiber Cable by Pulling

1 1/2 13.5, 625 JCASS)

Triax TechInfo. Installing and pulling Fibre Optic cables

TECHNICAL SPECIFICATION

WIRE CABLES PULL CABLES WR CONTROLS FLEXBALL ITALIANA CONDUIT FOR PULL CABLES WIRE FOR PULL CABLES

FIBER OPTIC CABLE CUT TO YOUR EXACT SPECS TO SAVE YOU TIME AND MONEY

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

Mining and Petrochemical Fiber Optic Cables

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

Micro duct Cable with HDPE Sheath for Installation by Blowing

FREEDM Loose Tube Interlocking Armored Cables

The MTS FiON Network. for Multiple Dwelling Units (MDUs) Greenfield/Brownfield Renovations

A IR-BL O W N SOLUTION C O D. M I C R O C O D. M I C R O D U C T

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

Ø 1000 * 588 mm 50 kg

Twin City Fan & Blower

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

Flexible Cord. Inside this section

OCC Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

HDMI Over IP Extender Kit - 4K

SECTION FIBER OPTIC STATION CABLES

Power cable accessories catalogue

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIAL SPECIFICATION 1438 Fiber Optic Cable (Single mode and Multimode)

SUMITOMO RECOMMENDED PROCEDURE SRP SP-F Ribbon Indoor/Outdoor Riser Cable Preparation

10G 6A F/UTP SYSTEM PRODUCTS 10G 6A F/UTP

Safe, Accurate, and Repeatable

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

COLORED CATEGORY 5e BULK CABLE, SOLID-CONDUCTOR PATCH CABLE, & CATEGORY 5e BACKBONE CABLE

VISION. Our Vision of what 120V LED Linear Should Be.

DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, RECEPTACLE, THREADED, JAM-NUT MOUNTING, REMOVABLE CRIMP CONTACTS, SERIES III, METRIC

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

Placing Fiber Optic Cable in Underground Plant

SECTION O FIBER OPTICS

SECTION TESTING OF COPPER CABLES

Product Catalogue. Fibre Optic Cable

Empowering businesses through innovative network solutions.

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

Splice Closure Fiber (SCF) Family

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

TechLogix Media over Fiber Optics. Connecting AV at the Speed of Light

CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories

Ultra Quiet Series Electric Air Handler

Fiberglass - Technical Data

FIBER OPTICS. UNDERGROUND FIBER OPTICS IX Page 1 of 18. Underground Electric Distribution Standards I. ENGINEERING

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

GenSPEED Category 5e Cables 3

SPECIFICATION. Optical Fiber Cable

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

Specification DNA Tracking Resistant ADSS Cable AC024AP6821BD0

10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP

J-Pro Cable Support System Let Panduit Support Your Cables

Special Specification 6242 Special Fiber Optic Cable

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

SPECIFICATION FOR FIBER OPTIC SPLICE CLOSURE

Part Number: 7940A Cat 6 DataTuff, (4 pr) 23 AW G Solid BC, PO/PVC, EtherNet/IP, CMR, CMX-Outdoor

Tape and Reel Packaging for Semiconductor Devices. Technical Data

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

System 500. Non-fire-rated, mineral insulated copper sheathed wiring cable

Michigan State University Construction Standards EXTERIOR FIBER OPTIC CABLE SYSTEM PAGE

Installation Guide OvalSox TM Cable

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

KEL 24 Cable entry frames

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

Tools & Accessories JackEasy Termination Tool TAS. Tools & Accessories

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

Aerial Cable Installation Best Practices

MANUAL CABLE MARKING SYSTEM PMP-30 PUSH-IN CABLE MARKERS WITH HOLDERS

LD OEM/LD PDS/LD PeCo

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

1672A. Product Description. Product Specifications. Technical Specifications. Conductor. APAC Standard. Bend Radius.

CUSTOM-LENGTH PATCH CABLES CUT-TO-LENGTH BULK FIBER PRE-TERMINATED FIBER MULTI-COLORED FIBER

SECTION 7 -- CROSS-CONNECT SYSTEMS

Transcription:

MAXCELL EDGE 4.00 MaxCell Edge is a fabric innerduct designed to enable installation of up to 300% more cables than rigid HDPE innerduct in conduit based network infrastructure. MaxCell Edge products can be used to create additional pathways in conduit. Solves cabling issues for conduits, allowing a range of cable sizes Enables overlay of cables in occupied conduits Reduces or eliminates number of conduits required in new construction Melting point of 419 F (almost twice that of HDPE) Resistant to ground chemicals and petroleum products Constructed of PET multifilament and Nylon 6 monofilament yarns Patented fabric design may reduce pulling tension by up to 20% over previous MaxCell versions Features color coded, pre-installed 1250LB pull tape in each cell Pre-lubed for lower friction during MaxCell and cable installation * Manufactured in the U.S.A. *Additional lubrication is recommended to further decrease friction during cable installation. MaxCell Edge, Plenum, Riser, and Detectable are available in multiple sizes and configurations. Contact customer service for more information on your specific application. PRODUCT # MIN CONDUIT ID CELLS REPLACES MXE8638: 4 MAX CABLE DIAMETER PER CELL TYPICAL PULL LENGTH MAX PULL LENGTH** MXE86383 4.00" 3 Cell MXC4003 1.50" 1250 2000 ** Use of OFNR cable may result in reduced pulling lengths. Designers should make every effort to conform to industry standards with regard to distances between any two pull points (generally 600 to 1,000 ft), number of bends (maximum of two 90 bends or a total of 180 ) between any two pull points, and proofing of conduit pathway using appropriately sized mandrels (normally ¼ to ½ less than the inside diameter of the conduit). MXE86383 APPLICATION GUIDE CONDUIT SIZE MAX. # OF PACKS MAX. # OF CABLES 4 2 6 5 3 9 6 4 12 IMPORTANT INSTALLATION TIPS Swivels must be used when pulling MaxCell The factory installed pull tapes in each cell must free-float during installation WATCH INSTALLATION VIDEO SCAN QR CODE www.maxcell.us/installation.aspx Please see reverse side for additional ordering information and part number configuration.

4.00 ORDERING GUIDELINE How do MaxCell part numbers work? MX E 8638 3BK 1000 MX: Standard prefix to identify the product as a MaxCell item. E: Product Line Code: E-Edge; ED-Edge Detectable; P-Plenum; R-Riser 86: Product Width (Millimeters) 38: Maximum Outside Diameter of Cable (Millimeters) 3: Number of Cells BK: Thread Identification Color (Varies Per Product): BK-Black (Standard); BL-Blue; GR-Green; RD-Red; YL-Yellow 1000: Standard Length (Feet)*: 250 ft; 500 ft; 1,000 ft; 2,650 ft; 5,300 ft; 10,000 ft * Contact customer service regarding custom lengths of MaxCell (available in 5 increments). Reel sizes may vary. PROJECT WORKSHEET Project Name: BASE PRODUCT # # OF CELLS THREAD COLOR LENGTH (FT) EXAMPLE: MXE8638 3 BK 1000

MAXCELL EDGE 3.00 MaxCell Edge is a fabric innerduct designed to enable installation of up to 300% more cables than rigid HDPE innerduct in conduit based network infrastructure. MaxCell Edge products can be used to create additional pathways in conduit. Solves cabling issues for conduits, allowing a range of cable sizes Enables overlay of cables in occupied conduits Reduces or eliminates number of conduits required in new construction Melting point of 419 F (almost twice that of HDPE) Resistant to ground chemicals and petroleum products Constructed of PET multifilament and Nylon 6 monofilament yarns Patented fabric design may reduce pulling tension by up to 20% over previous MaxCell versions Features color coded, pre-installed 1250LB pull tape in each cell Pre-lubed for lower friction during MaxCell and cable installation * Manufactured in the U.S.A. *Additional lubrication is recommended to further decrease friction during cable installation. MaxCell Edge, Plenum, Riser, and Detectable are available in multiple sizes and configurations. Contact customer service for more information on your specific application. PRODUCT # MIN CONDUIT ID CELLS REPLACES MXE6428: 3 MAX CABLE DIAMETER PER CELL TYPICAL PULL LENGTH MAX PULL LENGTH** MXE64283 3.00" 3 Cell MXC3456 1.05" 1250 2000 ** Use of OFNR cable may result in reduced pulling lengths. Designers should make every effort to conform to industry standards with regard to distances between any two pull points (generally 600 to 1,000 ft), number of bends (maximum of two 90 bends or a total of 180 ) between any two pull points, and proofing of conduit pathway using appropriately sized mandrels (normally ¼ to ½ less than the inside diameter of the conduit). MXE64283 APPLICATION GUIDE CONDUIT SIZE MAX. # OF PACKS MAX. # OF CABLES 3 2 6 4 3 9 5 4 12 6 5 15 IMPORTANT INSTALLATION TIPS Swivels must be used when pulling MaxCell The factory installed pull tapes in each cell must free-float during installation WATCH INSTALLATION VIDEO SCAN QR CODE www.maxcell.us/installation.aspx Please see reverse side for additional ordering information and part number configuration.

3.00 ORDERING GUIDELINE How do MaxCell part numbers work? MX E 6428 3BK 1000 MX: Standard prefix to identify the product as a MaxCell item. E: Product Line Code: E-Edge; ED-Edge Detectable; P-Plenum; R-Riser 64: Product Width (Millimeters) 28: Maximum Outside Diameter of Cable (Millimeters) 3: Number of Cells BK: Thread Identification Color (Varies Per Product): BK-Black (Standard); BL-Blue; GR-Green; RD-Red; YL-Yellow 1000: Standard Length (Feet)*: 250 ft; 500 ft; 1,000 ft; 2,650 ft; 5,300 ft; 10,000 ft * Contact customer service regarding custom lengths of MaxCell (available in 5 increments). Reel sizes may vary. PROJECT WORKSHEET Project Name: BASE PRODUCT # # OF CELLS THREAD COLOR LENGTH (FT) EXAMPLE: MXE6428 3 BK 1000

MAXCELL EDGE 2.00 MaxCell Edge is a fabric innerduct designed to enable installation of up to 300% more cables than rigid HDPE innerduct in conduit based network infrastructure. MaxCell Edge products can be used to create additional pathways in small conduits and are designed for applications where space is limited. Solves cabling issues for smaller ducts, allowing a range of cable sizes Enables overlay of cables in occupied conduits Reduces or eliminates number of conduits required in new construction Melting point of 419 F (almost twice that of HDPE) Resistant to ground chemicals and petroleum products Constructed of PET multifilament and Nylon 6 monofilament yarns Patented fabric design may reduce pulling tension by up to 20% over previous MaxCell versions Features color coded, pre-installed 1250LB pull tape in each cell Pre-lubed for lower friction during MaxCell and cable installation * Manufactured in the U.S.A. *Additional lubrication is recommended to further decrease friction during cable installation. MaxCell Edge, Plenum, Riser, and Detectable are available in multiple sizes and configurations. Contact customer service for more information on your specific application. PRODUCT # MIN CONDUIT ID CELLS REPLACES MXE5222: 2.00 MAX CABLE DIAMETER PER CELL TYPICAL PULL LENGTH MAX PULL LENGTH** MXE52221 2.00" 1 Cell MXC2001.85" 800 1500 MXE52222 2.00" 2 Cell MXC2002.85" 800 1500 MXE52223 2.00" 3 Cell MXC2003.85" 800 1500 MXE52224 2.00" 4 Cell N/A.85" 800 1500 ** Use of OFNR cable may result in reduced pulling lengths. Designers should make every effort to conform to industry standards with regard to distances between any two pull points (generally 600 to 1,000 ft), number of bends (maximum of two 90 bends or a total of 180 ) between any two pull points, and proofing of conduit pathway using appropriately sized mandrels (normally ¼ to ½ less than the inside diameter of the conduit). IMPORTANT INSTALLATION TIPS Swivels must be used when pulling MaxCell The factory installed pull tapes in each cell must free-float during installation WATCH INSTALLATION VIDEO SCAN QR CODE www.maxcell.us/installation.aspx Please see reverse side for additional ordering information and part number configuration.

2.00 ORDERING GUIDELINE How do MaxCell part numbers work? MX E 5222 3BK 1000 MX: Standard prefix to identify the product as a MaxCell item. E: Product Line Code: E-Edge; ED-Edge Detectable; P-Plenum; R-Riser 52: Product Width (Millimeters) 22: Maximum Outside Diameter of Cable (Millimeters) 3: Number of Cells BK: Thread Identification Color (Varies Per Product): BK-Black (Standard) 1000: Standard Length (Feet)*: 250 ft; 500 ft; 1,000 ft; 2,650 ft; 5,300 ft; 10,000 ft * Contact customer service regarding custom lengths of MaxCell (available in 5 increments). Reel sizes may vary. PROJECT WORKSHEET Project Name: BASE PRODUCT # # OF CELLS THREAD COLOR LENGTH (FT) EXAMPLE: MXE5222 3 BK 1000

MAXCELL EDGE 1.10 TO 1.75 MaxCell Edge is a fabric innerduct designed to enable installation of up to 300% more cables than rigid HDPE innerduct in conduit based network infrastructure. MaxCell Edge products can be used to create additional pathways in small conduits and are designed for applications where space is limited. Solves cabling issues for smaller ducts, allowing a range of cable sizes Enables overlay of cables in occupied conduits Reduces or eliminates number of conduits required in new construction Melting point of 419 F (almost twice that of HDPE) Resistant to ground chemicals and petroleum products Constructed of PET multifilament and Nylon 6 monofilament yarns Patented fabric design may reduce pulling tension by up to 20% over previous MaxCell versions Features patented 1250LB Vis Glide Rope in each cell Pre-lubed for lower friction during MaxCell and cable installation * Manufactured in the U.S.A. *Additional lubrication is recommended to further decrease friction during cable installation. MaxCell Edge, Plenum, Riser, and Detectable are available in multiple sizes and configurations. Contact customer service for more information on your specific application. PRODUCT # MIN CONDUIT ID CELLS REPLACES MXE2810: 1.10 MAX CABLE DIAMETER PER CELL TYPICAL PULL LENGTH MAX PULL LENGTH** MXE28101 1.10 1 Cell N/A.40 800 1500 MXE28102 1.10 2 Cell N/A.40 800 1500 MXE28103 1.10 3 Cell N/A.40 800 1500 MXE3212: 1.25" MXE32121 1.25" 1 Cell MXCM3301.45 800 1500 MXE32122 1.25" 2 Cell MXCM3302.45 800 1500 MXE32123 1.25" 3 Cell MXCM3303.45 800 1500 MXE3614: 1.50" MXE36141 1.50" 1 Cell N/A.55" 800 1500 MXE36142 1.50" 2 Cell N/A.55" 800 1500 MXE36143 1.50" 3 Cell N/A.55" 800 1500 MXE4418: 1.75" MXE44181 1.75" 1 Cell N/A.70" 800 1500 MXE44182 1.75" 2 Cell N/A.70" 800 1500 MXE44183 1.75" 3 Cell N/A.70" 800 1500 MXE44184 1.75" 4 Cell N/A.70" 800 1500 ** Use of OFNR cable may result in reduced pulling lengths. Designers should make every effort to conform to industry standards with regard to distances between any two pull points (generally 600 to 1,000 ft), number of bends (maximum of two 90 bends or a total of 180 ) between any two pull points, and proofing of conduit pathway using appropriately sized mandrels (normally ¼ to ½ less than the inside diameter of the conduit). Please see reverse side for additional ordering information and part number configuration.

1.10 TO 1.75 ORDERING GUIDELINE How do MaxCell part numbers work? MX E 2810 2BK 1000 MX: Standard prefix to identify the product as a MaxCell item. E: Product Line Code: E-Edge; ED-Edge Detectable; P-Plenum; R-Riser 28: Product Width (Millimeters) 10: Maximum Outside Diameter of Cable (Millimeters) 2: Number of Cells BK: Thread Identification Color (Varies Per Product): BK-Black (Standard) 1000: Standard Length (Feet)*: 250 ft; 500 ft; 1,000 ft; 2,650 ft; 5,300 ft; 10,000 ft * Contact customer service regarding custom lengths of MaxCell (available in 5 increments). Reel sizes may vary. PROJECT WORKSHEET Project Name: BASE PRODUCT # # OF CELLS THREAD COLOR LENGTH (FT) EXAMPLE: MXE2810 2 BK 1000