Do you need to replace discontinued instrumentation?

Similar documents
R&S FSV-K40 Phase Noise Measurement Application Specifications

Five Reasons to Upgrade from Legacy VNAs to a R&S ZNB Vector Network Analyzer

Test Port Adapter Rohde & Schwarz Interchangeable Port Connector Application Note

RF amplifier testing from wafer to design-in

Test and measurement solutions for electronics manufacturers

R&S WMS32 Wireless Measurement System Software Specifications

R&S FS-Z60/75/90/110 Harmonic Mixers for the R&S FSP/FSU/ FSQ/FSUP/FSV

DOCSIS 3.1 Full channel loading Maximizing data throughput

Fast. Accurate. USB-capable. Power sensors from Rohde & Schwarz

Rohde & Schwarz Service that adds value

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

Fast. Accurate. USB-capable. Power sensors from Rohde & Schwarz

Multi-port calibration by using a two port calibration unit. Application Note. Products: R&S ZVT R&S ZNB

R&S ZNrun Automated Test Software PC-based server platform for automated VNA tests

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

R&S RSC Step Attenuator Where precise signal levels count

R&S FSW-K160RE 160 MHz Real-Time Measurement Application Specifications

R&S FSV-K73 3G FDD UE (UL) Measurements incl. HSUPA Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

Concise NFC Demo Guide using R&S Test Equipment Application Note

R&S FPS-K18 Amplifier Measurements Specifications

Rohde & Schwarz Service that adds value

Pre-5G-NR Signal Generation and Analysis Application Note

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

R&S FSV-K8 Bluetooth /EDR Measurement Application Specifications

R&S ZN-Z85 Switch Matrix Specifications

All doors in flight. Terrestrial air navigation test and measurement solutions.

R&S FSW-K54 EMI Measurement Application Detecting and eliminating electromagnetic

R&S FSW-K144 5G NR Measurement Application Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

History for R&S Spectrum Analyzer IVI-COM Driver. Driver Documentation

Be ahead in 5G. Turn visions into reality.

R&S GX460 Digital Wideband Storage Device Recording and replaying device for I/Q data with up to 40 MHz bandwidth

R&S ELEKTRA EMI Test Software Easy to use software for measuring electromagnetic disturbances

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter

LabWindows/CVI, VXIpnp driver history for the R&S Vector Network Analyzers Driver Documentation

R&S ZN-Z154 Calibration Unit Specifications

Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

R&S FSV-K76 TD-SCDMA BS (DL) Measurements Specifications

Rohde & Schwarz Service that adds value

R&S GX465 Digital Wideband Storage Device Recording and replaying of I/Q data with up to 80 MHz bandwidth

R&S InstrumentView Release Notes Software Version 1.70

Dynamic re-referencing Microvolt-level measurements with the R&S RTO oscilloscopes

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S Spectrum Rider FPH Handheld spectrum analyzer

R&S FPC-Z10 Teaching Kit Getting Started

Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

R&S PSL3 Industrial Controller The powerful industrial controller

R&S SMBV-Z1 Reference Frequency Converter Specifications

R&S VENICE On air. 24/7.

R&S FSQ-K91/K91n/K91ac WLAN a/b/g/j/n/ac Application Firmware Specifications

Your partner in testing the Internet of Things

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

R&S SFD DOCSIS Signal Generator Signal generator for DOCSIS 3.1 downstream and upstream

Test Device Containment Module (TCM) Optimal conditions for reliable results

Scope of the art Scope Rider Handheld digital oscilloscope

Product Brochure Version R&S TSML-CW Radio Network Analyzer Powerful scanner for CW applications

R&S ZN-ZTW Torque Wrench Specifications

Iterative Direct DPD White Paper

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

R&S VENICE The ingest and playout platform.

Oscilloscopes for debugging automotive Ethernet networks

R&S ZND Vector Network Analyzer Basic, solid-performance network analysis

R&S TS-ISC In-System Calibration Kit On-site calibration solution for R&S CompactTSVP

R&S HF907DC SHF Downconverter Specifications

R&S CONTEST ITS Test cases and applications

R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications

R&S FSV Signal and Spectrum Analyzer Specifications

EUTRA/LTE and LTE-Advanced Signal Analysis Transmitter measurements on LTE signals

Efficient analysis of power and signal integrity and EMC

LabWindows/CVI, VXIpnp driver history for the R&S Spectrum Analyzers Driver Documentation

The Future of EMC Test Laboratory Capabilities. White Paper

EUTRA/LTE Downlink Specifications

Mastering Phase Noise Measurements (Part 3)

R&S RT-ZM Modular Probe System

R&S VSE Vector Signal Explorer Base Software Specifications

R&S FSW Signal and Spectrum Analyzer Resolving Security Issues When Working in Secure Areas

NPR Noise Power Ratio Signal Generation and Measurement Application Note

R&S NESTOR-FOR Crime Scene Investigation

R&S SGMA Product Family Compact fast reliable

LabWindows/CVI, VXIpnp driver history for the R&S SGMA Vector RF Source

R&S CA210 Signal Analysis Software Offline analysis of recorded signals and wideband signal scenarios

Radar signal interception moves into the digital age. Innovative ELINT solution from Rohde & Schwarz. Radar signal interception

EX-IQ-Box Digital Signal Interface Module Specifications

This application note is a simple step-by-step guide that introduces a practical method to perform reliable small cell planning.

R&S RT-Zxx High-Voltage and Current Probes Specifications

Remote Emulation with the R&S SMF100A Microwave Signal Generator Application Note

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

Product Brochure Version R&S AdVISE Visual Inspection Software A new way to eliminate human inattention

Stream Libraries For broadcasting T & M equipment from Rohde & Schwarz

The new benchmark for efficiency in the field The ZVH cable and antenna analyzer

R&S TS-PMB Switch Matrix Module High-density, 90-channel, full matrix relay multiplexer module

Massive MIMO Eight things to consider when testing antenna arrays

Configuring the R&S BTC for ATSC 3.0 Application Note

Transcription:

Do you need to replace discontinued instrumentation? Rohde & Schwarz offers signal generators as well as spectrum and network analyzers that understand the existing code written for your test system. Retain your current test system software Benefit from our experience in code emulation Rely on our long-term support

Legacy Pro: What it is all about Are you looking for a technology refresh? Overcoming test equipment obsolescence is paramount in military and aerospace applications. Test system support equipment often has a service life of more than 20 years and managing obsolescence over these extended periods is a critical part of the total life cycle support effort. However, replacing one or more obsolete instruments in a test system can have major consequences for the deployed test program set (TPS). An emulation strategy can help you incorporate new test instruments, providing a migration path from old obsolete instruments. The major challenge is managing this replacement without changing the existing TPS as the cost of a TPS rewrite dwarfs the cost of instrument replacement. Challenges in replacement There are important aspects related to replacing obsolete instruments which must be carefully considered. When legacy models are replaced, new versions are not necessarily compatible with the previous ones, either in terms of functionality or remote control command sets. The requirement of having minimal or no change to the TPS confronts instrument vendors with different challenges. In order to achieve backward compatibility, the emulation of obsolete instrumentation must include not only code compatibility but also behavioral compatibility. Lessons learned Over the years, Rohde & Schwarz has acquired extensive experience related to the requirements and challenges of emulating complex instruments such as network analyzers and spectrum analyzers. For example, in order to achieve behavioral compatibility the emulation capabilities of modern spectrum analyzers must appropriately handle different mixer levels, analog vs. digital resolution bandwidth filters, swept frequency spans vs. digital FFTs, etc. To solve your problem, Rohde & Schwarz can bring to bear its vast amount of knowledge and the lessons learned from its experience with automatic test equipment (ATE). Not only can we help mitigate migration risks, we can also suggest improvements in the areas of throughput and yield that have worked in similar applications. Backward compatibility requires command compatibility and true functional/behavioral compatibility. Rohde & Schwarz is a tried-and-tested partner for migrating, upgrading or modernizing your ATE. Does your ATE system consist of obsolete models from a variety of suppliers? Rohde & Schwarz spectrum and network analyzers and signal generators emulate a comprehensive set of legacy test equipment from HP/Agilent, IFR/Aeroflex, Anritsu and others. Are ATE instrument specifications and form-factor issues a concern? Rohde & Schwarz offers a broad range of instrument solutions to meet your ATE specification, application and architectural requirements. Legacy Pro instruments can also assist in reducing your overall ATE form factor by combining multiple instrument functionality into one single-box solution. Do you have any concerns regarding risk mitigation and total cost of ownership? Rohde & Schwarz has a long and successful history of working directly with customers whom we helped to replace legacy instrumentation. Our local application engineering expertise ensures seamless legacy code migration. Since we work to solve even the toughest corner-case code emulation problem, we continually receive positive customer feedback. We are committed to reducing total cost of ownership and actively work with A&D self-maintainer organizations by providing excellent and flexible support tools to make sure our equipment will meet the very long product life cycle demands on your military ATE systems.

Legacy Pro: Compatibility matrix Spectrum Analyzers FSU, FSQ FSV FSW HP 8560E HP 8561E/EC HP 8562E HP 8563E HP 8564E HP 8565E HP 8566A HP 8566B HP 8568A HP 8568B HP 8591E HP 8594E HP 8594L HP 71100C/P HP 71200C/P HP 71209C/P PSA 1) FSEA/B/M/K FSP/U/Q 1) Support of IQ read-out Network Analyzers R&S ZVL R&S ZVB, R&S ZVA R&S ZNB, R&S ZNC PNA 1) HP 8714 HP 8719C/D/ES/ET HP 8720C/D/ES/ET HP 8722C/D/ES/ET HP 8730A HP 8753C/D/ES/ET/A/B HP 8510C HP 8510SX HP 85106D HP 85107B HP 8510XF HP 85108A ENA 1) 1) Development ongoing FSV ZVA FSW ZVL Spectrum Analyzer Network Analyzer Spectrum Analyzer Network Analyzer

Signal Generators SMA100A SMB100A (1.1 GHz/2.2 GHz/ 3.2 GHz/6 GHz) R&S SMB100A (12.75 GHz/20 GHz/ 40 GHz) R&S SMBV100A R&S SMC100A R&S SMF100A HP 8642 HP 8643/8644/8645 HP 8647/8648 HP 8656/8657 HP 8662/8663 HP 8664/8665 HP 8673 HP 8340/8341 HP 83620/83622/83623/83624/83630 HP 83711/83712 HP 83731/83732 Agilent E4428C (ESG analog) Agilent E4438C (ESG vector) Agilent E8257D (PSG analog) Agilent E8663B/D (PSG analog) Agilent N5161A (MXG analog) Agilent N5162A (MXG vector) Agilent N5181A (MXG analog) Agilent N5182A (MXG vector) Agilent N5183A (MXG microwave) Aeroflex 2030/2031/2032 Aeroflex 2040/2041/2042 Aeroflex 2050/2051/2052 Anritsu 68017/68037 Racal-Dana 3102 Racal-Dana 9087 SMGU SMHU SML SMT SMY SMV SMR SME SMP PA8303 SMA 100A SMB 100A SMC 100A SMBV 100A Signal Generator RF and Microwave Signal Generator Signal Generator Vector Signal Generator

Power Meters Agilent/HP 436A Agilent/HP 437B Agilent/HP 438A Agilent E4418B/E4419B Agilent N1911A/N1912A NRP RNVD R&S NRP2 Audio Analyzers R&S UPV R&S UPP HP 8903B Legacy Pro: Achieving code compatibility Migrating from obsolete instrumentation requires new instruments that emulate the legacy instruments to achieve code compatibility. Usually this requires the same interface (GPIB) that was used in the existing test system and an adoption of the existing command language. SCPI (Standard Commands for Programmable Instruments) has reduced the problem of interchangeability significantly. Since the late 1990s, remote control of most instruments is based on the common SCPI standard. Before that, legacy instruments used a vendor-specific command set which differed in syntax and semantics. However, the situation is quite different if these instruments need to be compatible with those of the earlier generations. This requires switching from the SCPI parser to a parser for the legacy commands which can understand the old syntax. During the development of code compatibility for legacy instruments, a number of issues came up that challenge developers of the emulation mode. Simply translating the legacy commands into SCPI is not enough. The emulation mode has to be activated first together with the selection of the emulated instrument model. While most of the legacy instruments share a common set of remote commands, each model may respond to the commands quite differently. With R&S Legacy Pro, not only does the new instrument understand the legacy commands for correct implementations, it also makes the responses from the instrument, such as measurement results and query results, understandable to the legacy remote program. Read more on the R&S Legacy Pro web page! Drop-down menu list with all emulated HP analyzers (shown here: the FSV). SMF 100A NRP2 UPV UPP Microwave Signal Generator Power Meter Audio Analyzer Audio Analyzer

Customer Support Europe, Africa, Middle East +49 89 4129 123 45 customersupport@rohde-schwarz.com North America 1 888 837 87 72 (1 888 TEST RSA) customer.support@rsa.rohde-schwarz.com Latin America +1 410 910 79 88 customersupport.la@rohde-schwarz.com Asia / Pacific + 65 65 13 04 88 customersupport.asia@rohde-schwarz.com China +86 800 810 8228/+86 400 650 5896 customersupport.china@rohde-schwarz.com www.rohde-schwarz.com is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners Data without tolerance limits is not binding Subject to change September 2013 PD 5214.5603.62 V01.05