Tucker Theatre Policies and Procedures MTSU Department of Theatre 205 Boutwell Dramatic Arts Murfreesboro, TN 37132

Similar documents
* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Performing Arts Theatre

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

THEATRE PROJECTS. Parts of a Theatre Building

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

Technical Specifications and Inventory Spring 2018

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

Technical Specifications. Taylor Little Theater

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Technical Specifications

Sandusky State Theatre Technical Specifications

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Technical Specifications

DEREHAM MEMORIAL HALL

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

Technical Specifications

Concert Hall Technical Specifications

ARTPARK MAINSTAGE THEATER TECHNICAL PACKET

Marjorie S. Deane Little Theater

THE BELDING THEATER. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

TECHNICAL PACKAGE.

Concert Hall Technical Specifications

Technical Information

Technical Services and Specification

Technical Specifications

Princess of Wales. General Info and Technical Package

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Arcadia Performing Arts Center Technical Specifications and Information

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

SAINT ANSELM COLLEGE DANA CENTER

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

FOX THEATRE ST. LOUIS

SECREST AUDITORIUM TECHNICAL PACKAGE

Downtown Arts Center Tech Packet. General Information

TECHNICAL SPECIFICATIONS AND INVENTORY PANTAGES THEATER

P.O Box 1171 Box Office & Theatre: (903) Main St Texarkana, TX TRAHC Office: (903) Texarkana, TX Fax: (903)

Facility Information

1/16 Virginia Tech/Blacksburg, VA/Haymarket Theatre

FIVE FLAGS THEATER SERVICES STATEMENT

Technical Information

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Facility Rental Reservation & Contract

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Theatre Technical Specifications

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

SHUBERT THEATER 247 College Street, New Haven, CT

PRODUCTION INFORMATION

Lighting Information

Martin W. Kappel Theater TECHNICAL INFORMATION Revision D February 25, 2013

Jacoby Auditorium - Technical Rider UCC Special Events Office Phone:

PRODUCTION PHONE NUMBERS:

NORTH CHARLESTON PERFORMING ARTS

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

TECHNICAL INFORMATION DRIVING DIRECTIONS

Studio 180. Electronic and Print versions of the venue ground plan are available from the Technical Director.

VENUE TECHNICAL REQUIREMENTS

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

TECHNICAL INFORMATION

Reynolds Performance Hall Facility Regulations and Fee Schedule

TECHNICAL INFORMATION & SERVICES

Patriots Theater at the War Memorial Technical Data

Technical Specifications

Technical Specifications

The Breen Center for the Performing Arts Saint Ignatius High School

Dinkelspiel Auditorium - Technical Specifications

CENTRE FOR PERFORMING ARTS

Technical Specification Pavilion Dance

Master Electrician Handbook

Live From Nashville TECHNICAL RIDER

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115

ADDENDUM A / TECHNICAL RIDER

NORTH CHARLESTON PERFORMING ARTS

Paramount Theatre Production Recap

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

The ACT Facility Technical Specifications Main Stage Information

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

Smothers Theatre Rental Technical Specifications

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

Rentals Friedman Auditorium

Bartlesville Community Center

Dale F. Halton Theater Technical Specifications

University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts

Directions. Driving directions and other UCSD maps

Smothers Theatre Technical Specifications Pepperdine University

Ordway for the Performing Arts Concert Hall Technical Information

Struthers Library Theatre

Contact Information. Karen Jones Accounting Specialist Phone:

Performance Dates and Times Date Time You Arrive Time Audience Arrives Performance Time Anticipated End Time

Dr JOHN GALLAGHER CONCERT CHAMBER

JERWOOD VANBRUGH THEATRE

HUECO / Technical Rider

Our History. Clara Hughes Brott Music Festival Gail Vaz-Oxlade Jimmie Vaughan CBC Townhalls Hamilton Philharmonic Youth Orchestra Wild Kratts

Transcription:

Tucker Theatre Policies and Procedures MTSU Department of Theatre 205 Boutwell Dramatic Arts Murfreesboro, TN 37132 GENERAL INFORMATION Tucker Theatre is a proscenium theatre with two side stages. Auditorium Capacity o Main Floor: 549 seats o Balcony: 290 seats o Total: 855 seats (see seating plan) Load-in point: Loading dock at stage level is outside of the scene shop located off stage left. A load-in to the stage is through the shop. The loading door is 9'-0" wide by 10'-0" high. Orchestra Pit: Located under the apron, its use requires significant advance notice. There is no lift system of any kind installed. Floor of the pit is 10'-0" below stage deck level. STAGE INFORMATION Proscenium opening: 40'-0" wide and 20'-0" high Height of stage from auditorium floor: 3'-7" Front edge of apron to curtain line: 18'-0" O.C. Curtain line to back wall: 38'-0" O.C. Wing space stage left: 7'-0" and opens into shop. Wing space stage right: 4'-0" off stage of cyc. Height of grid: 50'-5 1/2" Usual trim height: 20'-0" to 22'-0" Crossover: Through hallway behind stage. Stage Floor: Wood floor, slightly resilient, over cement beam support structure. Traps: Three 3'-0" x 6'-0" removable traps (see Floor Plan) Floor surface condition: Fair Side Stages: Proscenium: 11 0 (h) x 16 0 (w); Black velour draw curtain manually operated: Operating lines are D.S.- Curtain Closes to U.S. These positions are difficult to light well. Orchestra Pit: Tucker Theatre has an orchestra pit that can be uncovered upon adequate advance request. MASKING A. Main Curtain: NAVY Velour - Fly and Draw manual operation - Two panels 26'-0" x 24'-0" high B. Teaser Black velour 5 Available 6'-0" x 48'-0" C. Side Stage Curtains (2) Black Velour Manual draw operation (Lines DS) D.S. full open, U.S. full closed 11'-0" X 12'-0" D. Legs Black velour 5 sets 10'-0" x 22'-0" E. Traveler Two Black Velour sets (One at half Stage and one at Upstage) Each panel 26'-0" X 24'-0" Printed: 11:22 AM, Tuesday, September 27, 2016

F. Cyclorama Unbleached muslin -- off-white color Hung on curved batten 25'-0" X 44'-0" Encloses stage space of 59'-0" X 31'-0" with all pipes flying within this space Cyc is hung on line 25, 31'-0" from plaster line, O.C. LOBBY Lobby Location: Tucker Theatre contains one lobby located in front of the auditorium. Lobby Facilities: The lobby provides a large seating/lounge area furnished with couches, chairs and tables. To the lobby right is a men's restroom and drinking fountain and to the lobby left are a women's lounge and restrooms and a drinking fountain. Please arrange all use of the lobby through the house technician. Box Office: There is one box office with three ticket windows. Decorations: The lobby may be decorated by the visiting group for their performance but all materials must be removed by the group afterward. No double-sided tape is permitted in hanging decorations. In addition, any permanent marring of the lobby surfaces will be charged to the user group. Food and drink are NOT allowed in the auditorium. Chairs & Tables: Folding tables and chairs are available for visitor's use. Please notify the Theatre Manager in advance of these needs. Marquee: The marquee may be used for advertising and promotion of individual events. All material must be presented to the theatre technician two weeks in advance of event. Handicapped Access: There is no handicapped access directly to the lobby. Access is from house left outside doors into auditorium and up house left aisle. Lobby restrooms are handicapped accessible. Crowd Control: Stanchions are available for crowd control and limiting access to areas. GREEN ROOM Location: BDA 112, Off the back stage hallway. Description: Room is furnished with chairs, couches and tables. DRESSING ROOMS Quantity & Capacity: Total Number of Rooms: 2 (one male, one female) contains restrooms with two showers each. Maximum capacity: Male - 16, Female - 14 Location: In hall behind stage on stage level. Access is from U.S.L. and down the hallway, or from U.S.R. and across the hallway. Description: Each dressing room is furnished with one full length mirror, racks to hang costumes and a separate room containing a sink with lighted mirror, toilet and two showers. MAKEUP ROOM There is one (1) Make-up room with a maximum capacity of 20 persons. Location: In hallway behind stage, on stage level. Description: One large room containing counters, chairs, lighted individual makeup mirrors and a sink with hot and cold water. Supplies: No makeup or makeup supplies are provided in house. This includes tissues and soap. PAGE 2 OF 6

Communication System A. Theatre Communication System 4 wired ClearCOM units with headsets Single Channel 1 Auxiliary power unit for ClearCOM 4 Wireless ClearCOM units with Headsets 1 Wired ClearCOM Headset and control unit for each: Stage Management, Lighting, Sound B. Other Telex in Orchestra pit, balcony, and catwalk. FLY SYSTEM A. Tucker Theatre is equipped with a single purchase, counter-weight system. Total line sets: 25 Unavailable line sets: 4 and 5, 10 and 11, & 19 and 20 are electrical line sets used for lighting. Lines 2 and 3 are act curtain and teaser/legs. Line 25 is the cyc. Line 23 is the rear projection screen. Lines will fly approx. 51'-0". Low pipe trim: 4'-7" B. Line Set Labeling Lines may be marked on the rail with 3x5 cards and ropes may be spiked with spike tape only. All cards and tape must be removed at strike. C. Strike All curtains must be returned to their original storage positions during strike. D. Operators Only qualified personnel may operate this system. These must be employees of MTSU for insurance reasons. E. Weight Regular brick 22 lbs Large brick - 44lbs Small Brick 12 lbs Lighting A. System Dimmers Strand CD-80 2400 watts Total number: 192 Dimmer per circuit, distributed throughout the space. Control Board ETC EOS - Fully Digital Console. Patch Soft patch on board, hard patch is dimmer per circuit. Power Source OSL Circuit breaker box 100A quick disconnect for bare tail hook-up University electrician is required to tie into this power source. **Must notify house technician two weeks in advance. Connectors All stage circuits are 20A, stage pin circuits. PAGE 3 OF 6 Gel

Tucker Theatre maintains a small assortment of gel in stock. Given adequate notice, Tucker Theatre may supply gel at cost to groups. Please note Some equipment may not be available due to routine maintenance rotation. To insure that equipment is available for your use, check with House Technician. B. Positions On stage First Electric pipe Pipe number 5 6'-0" from plaster line, O.C. Circuits numbered 81-102 and repeated 81-102 Second electric pipe Pipe number 9 11'-0" from plaster line, O.C. Circuits 103-128 and repeated 103-128 Third electric pipe Pipe number 12 15'-0" from plaster line, O.C. Circuits 129-144 and repeated 129-144 Fourth Electric Pipe Number 17 21-0 from plaster line, O.C. Circuits 147-156 and repeated 147-156 Fifth Electric Pipe Number 20 24-0 from plaster line, O.C. Circuits 157-169 and repeated 157-169 This pipe holds the far cyc units used to light the cyc. Cove Position (vertical pipes 21'-0" high with one side arm, positioned to be used as frontal-side lighting for the apron) 15'-0" In front of plaster line, apron L. & R. Curcuits: SR cove 81-83 and repeated. SL Cove 84-86 and repeated. Wall Pockets Tucker Theatre has two wall pockets located SL and SR on the proscenium wall. SL circuits 172-174, SR circuits 169-171. Rear Wall Pockets Rear Wall pockets are positioned on the back wall of the theatre behind the cyc. Each rear wall pocket contains three different circuits. The numbering runs consecutively from 175-188. C. Front of House (FOH) AP Pipe 3'-0" from plaster line, O.C. 20'-0" above stage level Circuits 64-78 and repeated 64-78 First beam position 29'-0" from plaster line, O.C. 34'-6" above stage level Circuits 19-48 and repeated 19-48 Second beam position (See Tucker Theatre Sectional Drawing) 49'-6" from plaster line O.C. PAGE 4 OF 6

33'-6" above stage level Circuits 1-18 and repeated 1-18 D. Follow Spots Located at rear of auditorium Two follow spots (see lighting inventory)are available for use See Theatre Manager to arrange for spot operators. ***** Due to Fire and safety Regulations, Lights may never be used on the front railing of the balcony. AUDIO / VISUAL EQUIPMENT Tucker Theatre can supply the following audio/visual equipment A. 1 - movie screen (15'-5" wide x 12'-6" high), rear projected and must be suspended from a pipe within the flyrail system B. 1 Video Screen 18 x 45. Rear or front projected. Must be suspended from the fly system. C. Any other equipment must be requested 2 weeks in advance and is subject to availability of MTSU production services. MISCELLANEOUS EQUIPMENT A. Ladders Visiting groups may use the following ladders only with permission of the Theatre Manager platform ladders 1-6'-0" 1-8'-0" 2-12'-0" 2 - Hydraulic Lift, 25-0 platform height MTSU and its employees assumes no responsibility for accidents. F. Lectern G. Piano (Baby Grand (black matte finish) Permission must be obtained in advance to use the piano The visiting group will be charged for tuning H. Telephones A telephone may be made available if requested. These phones may be used for local calls only. All long distance calls must be made on calling cards. Tucker Theatre cannot accept any phone charges. ADDENDUM A. ALTERATION OF PHYSICAL PLANT Please note that the user is not authorized to alter the physical plant, structure, or mechanical operation of Tucker Theatre or any of its support areas. This includes, but is not limited to: Modification, repair, or reassignment of any part of the rigging system of the theatre. Modification, repair, or adjustment to any part of the electrical system of the theatre. Structural changes to the facility, such as the addition or deletion of rigging positions, lighting positions; the rerouting of wiring, cabling, or conduit. Drilling, boring, or in any way penetrating cinder block, brick, concrete, steel, or any other such structural material located within the facility, where structural integrity will be jeopardized or visible scarring of the facility will result. B. REPAIRATION / MAINTENANCE OF EQUIPMENT PAGE 5 OF 6

Please note that any major repairs needed within the theatre plant must be contracted though an outside licensed and bonded contractor. Due to insurance and safety risks, none of the following type of repairs / maintenance may be performed by the user group or any of its technicians or staff: Any electrical work at the circuit level. This includes (but is not limited to): tapping off breaker boxes, rerouting existing wiring, adjusting connect panels, altering dimming systems, opening manufacturer sealed devices, removing electrical panel covers, or any other item that the departmental Technical Director deems as hazardous to the current and future safety of the employees, students, and physical plant of MTSU. Any structural rigging within the theatre plant. This includes (but is not limited to): replacing head blocks, loft blocks, cabling, battens, arbors, or any other part of the counterweight system; adding or deleting line sets; permanent or semi-permanent installation of rigging of any kind, or any other item that the Theatre Manager deems as hazardous to the current and future safety of the employees, students, and physical plant of MTSU. PAGE 6 OF 6