Owner Handbook Jupiter Blackhole LED UV Flood
For your Safety Follow all instructions to maintain Manufacturer Warranty and for your own safety. There are no user replacement parts inside the product. Do not open the product for any reason. This will invalidate your Manufacturer Warranty and may impair the safety features of the product. Do not expose this product to moisture, rain or other fluids. Do not use this product near water or other fluids. Do not use if the product if you suspect it has been damaged in any way, including being dropped, is malfunctioning, or has been exposed to liquids or moisture. The unit must be repaired by an authorised service centre only. Manufacturer Warranty is void if unit is opened or adapted in any way. Operator safety may be compromised if this product is not operated and maintained in accordance with the details contained in this Owner Handbook. This appliance must be earthed. Do not remove the earth connection in the plug or any other location- it is essential for user safety. Be aware that products are mains powered and may be capable of producing high voltages from its outputs and has mains voltages inside the cabinet. Product Installation, Use & Maintenance Keep this Owner Handbook safe for future reference. Clean the product with a clean and dry, non-abrasive cloth. Do not use solvents or liquids to clean the product. To prevent overheating, do not obstruct any ventilation opening, fan cover or vent. Do not install near any sources of heat such as radiators, heaters, other heat producing items such as amplifiers, power units etc. Power connection to the product is via a UK 240 Volt AC three-pin mains plug. Do not remove or adapt this plug. If necessary, only replace the plug top fuse with one of the same type, size and value. The mains lead must not be crushed or damaged. If any damage occurs, disconnect from the mains immediately. Replace the damaged cable, or if the mains lead is captive, return the product to an authorised repair centre for cable replacement. Do not attempt to repair the cable - it must be discarded and destroyed. To maintain the Manufacturer Warranty, only attach authorised accessories and external devices. This includes cables, connectors and other electrical and/or mechanical devices. Unplug the product from the mains during lightning storms or periods of mains fluctuations. If the product is going to be unused for long periods, unplug from the mains.
Product Quality & Compliance Products from Lanta Lighting meet all required safety standards in force at the time of manufacture and are fully compliant with them. Unpacking & Inspection Inspect the packaging before opening. If the packaging appears to have sustained significant damage, please take extra care before using the product. If you are in any doubt, consult a suitably qualified professional. If you suspect the product has been damaged, do not use it. Return it to your original supplier without delay. Keep all packaging in a safe place for storage or transport in future. Manufacturer Warranty This Manufacturer Warranty is valid in the UK only. Lanta Lighting warrants that this product is free from workmanship defects and material failure during normal use and operation for a period of 12 months from first use or from original date of sale (whichever is the earliest) providing all of the terms indicated in the warranty section have been fully complied with. Expressly excluded is our liability for any directly connected or indirectly connected item or items or any consequential loss associated with the failure of the product howsoever caused. If the product has been opened, modified, tampered with, incorrectly connected, used inappropriately or in conflict with the instructions herein, or the product model or serial number has been damaged, removed, tampered with, obliterated or made partly unreadable by any person or persons, the Manufacturer Warranty is irrevocably null and void. No extension, adaption, alteration or modification to the terms of this Manufacturer Warranty will be permitted, unless expressly authorised in writing (excluding email and fax) by a Director of Lanta Lighting. Warranty is transferrable during the Warranty period. For Further Information about Lanta Lighting Our website can be found at www.lantalighting.com and is available for the benefit of customers worldwide. Please consult for information, advice and support on this and other high quality products from Lanta.
About Lanta Lighting Based in the UK, Lanta are committed to providing high quality products at cost-effective prices to the professional lighting market. Since the first product was launched in 2006, Lanta has established a reputation for reliability, common sense design and customer support that has become the envy of others. The Lanta Lighting range includes:- Professional Lighting Focussing on the use of LED technology, Lanta offer distinctive lighting effects for install and mobile applications. From washes to floods, spots to projectors, LED technology now outperforms traditional lights while at the same time requiring significantly lower power and generating far less unwanted heat. Performance Lasers Recent advances have reduced the costs of Lasers, made them more portable and brought improved performance and reliability. With step and animation lasers in multi and single colour formats for mobile DJs and static installs, Lanta promise Lasers that won t burn a hole in your pocket. Atmospheric Effects When you need special atmospherics effects, Lanta have everything from bubble machines to fake snow, hazers and foggers. There s also a range of fluids and consumables specially designed to get the best from the range. Control Gear Lightweight and portable, Lanta Control Gear is robust enough to survive life on the road and smart enough to control DMX kit whatever the venue. Visit us at www.lantalighting.com for more details.
Getting to know your Lanta Product The Lanta Jupiter Blackhole is an indoor LED UV flood panel featuring ultraviolet LEDs. It has a built in flash facility and can be sound activated if required. Features can be DMX controlled from standard desks. LEDs DMX Control Control Connections Power Requirement Power Consumption Dimensions W x D x H Weight 288 10mm LEDs 3, 4, 6, 12 or 24 3 Pin Female XLR socket, 3 Pin Male XLR socket, 12v DC 240 Volt AC 50/60Hz 36 Watts 415mm x 270mm x 70mm 3.0Kg Power Input DC 12V Input DMX Input DMX Output Rear Panel
Operating Modes Five distinct operating modes are supported by the unit. To select, use the MODE button to enter the menu. The SETUP button steps through specific settings for each operating mode and the UP and DOWN buttons chooses from the values available. 1- In-built Program Mode One of the 12 in-built Effects is run. In this mode the LED Display will show values from PG.01 to PG.12. Effects are; LED Display Shows UV Effect PG.01 Static Flood PG.02 Slow Fade PG.03 Medium Fade PG.04 Fast Fade PG.05 Slow Flash PG.06 Spiral 1 PG.07 Spiral 2 PG.08 Spiral 3 PG.09 Spiral 4 PG.10 Fast Flash PG,11 Spiral 5 PG.12 Spiral 6
Static Flood (PG.01 Only) In this sub-mode a Static Flood can be chosen. With the LED Display reading PG.01, press SETUP again. The UP and DOWN buttons step between options. These are; LED Display Shows Static Flood C0L.0 Off C0L.1 Flood Pattern 1 C0L.2 Flood Pattern 2 C0L.3 Flood Pattern 3 C0L.4 Flood Pattern 4 C0L.5 Flood Pattern 5 C0L.6 Flood Pattern 6 C0L.7 Flood Pattern 7 Flash Frequency (PG.01 to PG.12) A press of the SETUP button changes the LED display to FS00 (for flash frequency). Speed can be set with the UP and DOWN buttons between FS01 (approx 0.5Hz) and FS99 (approx 40Hz). Speed Setting (PG.02 to PG.12) Pressing SETUP changes the LED display to SPA0 (for speed). Speed can be set with the UP and DOWN buttons between SP01 (slowest) and SP99 (fastest).
2- Auto Run Mode All series of UV Flood Effects are run one after another in a continuous loop. To select Auto Run Mode, use the MODE button to choose AUTO. Run Time Pressing SETUP changes the LED display to n.001. Run times can be set with the UP and DOWN buttons between n.001 (shortest) and n.100 (longest). 3- Slave Mode The unit will run in synch with another unit that has been set as the Master unit. To select, use the MODE button and choose SLA-.
4- Sound Activated Mode The unit responds to sounds picked up by the in-built microphone. To select, use the MODE button and choose S0.00. Sound Sensitivity Sensitivity can be set between S0.00 (least sensitive) and S0.31 (most sensitive) by using the UP and DOWN buttons. Change sub-mode Use the SETUP button to change the LED Display to nn-1. When a sound is detected, the current effect changes to the next in sequence. When set in this sub-mode, a continuous stream of music will create a series of shifting UV effects. Dimming sub-mode Use the SETUP button to change the LED Display to nn-2. When a sound is detected, the current effect flares then dims over ½ a second. The next sound input changes the effect to the next in the sequence, which then flares and dims again. When set in this sub-mode, a continuous stream of music will create a series of pulsing UV effects.
5- DMX Mode The unit supports 5 distinct DMX control modes from a standard desk. Setting DMX Addresses Use the MODE button to display Addr. Press SETUP to change the LED Display d.001. Use UP and DOWN buttons allows individual DMX addresses to be set from d.001 to d.512. Choosing between DMX Modes The LED display shows the chosen control mode when the SETUP button is pressed. Use UP and DOWN buttons to choose the appropriate DMX control mode. LED Display shows P4.Ch 03.Ch 06.Ch 12.Ch 24.Ch DMX Control Mode 4 3 6 12 24
DMX Control Settings 3 DMX 1 2 3 BankA 1-8 BankB 1-8 BankC 1-8 0-99 Off Off Off 100-150 151-200 201-255 Full On Full On Full On
DMX Control Settings 4 DMX Chan 1 * Chan 2A * Chan 2B * Chan 3A * Chan 3B * Chan 4A * Chan 4B Program Selection BankA 1-8 Sound Sensitivity BankB 1-8 Flash Frequency BankC 1-8 Background Colour 0-18 Master Dimming Off Least Sensitive Off 0.5Hz Off Off 19-37 Static Flood 38-56 Slow Fade 57-75 Medium Fade 76-94 Fast Fade 95-113 Slow Flash 114-132 Spiral 1 133-151 Spiral 2 152-170 Spiral 3 171-189 Spiral 4 190-208 Fast Flash 209-227 Spiral 5 228-246 Spiral 6 247-255 Sound Activated Full On Most Sensitive Full On 40Hz Full On Full On * Use s 2A (BankA), 3A (BankB), & 4A (BankC) when 1 DMX setting is 0-18. Use 2B (Sound Sensitivity) when 1 DMX setting is from 247-255. Use 3B (Flash Frequency) when 1 DMX setting is from 19-246. Use 4B (Background Colour) when 1 DMX setting is from 209-246.
DMX Control Settings 6 DMX 1 2 3 4 5 6 BankA 1-4 BankB 1-4 BankC 1-4 BankA 5-8 BankB 5-8 BankC 5-8 0-9 Off Off Off Off Off Off 10-19 20-29 30-39 40-49 50-59 60-69 70-79 80-89 90-99 100-109 110-119 120-129 130-139 140-149 150-159 160-169 170-179 180-189 190-199 200-209 210-219 220-229 230-239 240-255 Full On Full On Full On Full On Full On Full On
DMX Control Settings 12 DMX 1-100 101-200 1 2 3 4 5 6 BankA 1-2 BankB 1-2 BankC 1-2 BankA 3-4 BankB 3-4 BankC 3-4 0 Off Off Off Off Off Off 201-255 Full On Full On Full On Full On Full On Full On 12 DMX (continued) 1-100 101-200 7 8 9 10 11 12 BankA 5-6 BankB 5-6 BankC 5-6 BankA 7-8 BankB 7-8 BankC 7-8 0 Off Off Off Off Off Off 201-255 Full On Full On Full On Full On Full On Full On
DMX Control Settings 24 DMX Ch 1 Ch 2 Ch 3 Ch 4 Ch 5 Ch 6 Ch 7 Ch 8 BnkA 1 BnkB 1 BnkC1 BnkA 2 BnkB 2 BnkC 2 BnkA 3 BnkB 3 0 Off Off Off Off Off Off Off Off 1-100 101-200 201-255 Full On Full On Full On Full On Full On Full On Full On Full On 24 DMX (continued) Ch 9 Ch 10 Ch 11 Ch 12 Ch 13 Ch 14 Ch 15 Ch 16 BnkC 3 BnkA 4 BnkB 4 BnkC 4 BnkA 5 BnkB 5 BnkC 5 BnkA 6 0 Off Off Off Off Off Off Off Off 1-100 101-200 201-255 Full On Full On Full On Full On Full On Full On Full On Full On 24 DMX (continued) Ch 17 Ch 18 Ch 19 Ch 20 Ch 21 Ch 22 Ch 23 Ch 24 BnkB 6 BnkC 6 BnkA 7 BnkB 7 BnkC 7 BnkA 8 BnkB 8 BnkC 8 0 Off Off Off Off Off Off Off Off 1-100 101-200 201-255 Full On Full On Full On Full On Full On Full On Full On Full On
www.lantalighting.com