Furcation of a Central Tube Ribbon, Gel-Free, Non-Armored, 96- to 192-Fiber Cable into an OSE-UD

Similar documents
MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

Water blocking tape. Locator ridge HPA-0486

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

Splice Closure Fiber (SCF) Family

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

Instructions. Cable with Armor F CAUTION. October Rev A

IP-LINX. Installation Guide

FREEDM Loose Tube Interlocking Armored Cables

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

Medium Box for Cable Termination

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

IP-LINX Fiber :: X-XXXX

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

FOSC 450 C6 and D6 Closures

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

Gel-sealed in-line fiber optic closure

INSTALLATION INSTRUCTIONS

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

3M Cold Shrink Splice Kit QS-III 5416A

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

Cable Installation Tips

Cable Installation Tips

FIST-GCO2 GCO2-BC8 GCO2-BD8 GCO2-BE8 GCO2-BF8. 5 Heatshrink installation. 1 Introduction. Content. 6 Fiber routing. 2 General. 7 Fiber routing on tray

FOSC 400 A4 Fiber Optic Splice Closure

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

GCO2-BC6/16-XX GCO2-BD6/16-XX GCO2-BE6/16-XX

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

3M Cold Shrink Splice Kit QS-III 5515A

HCS - HES Cabling Systems

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

3M Cold Shrink Splice Kit QS-III 5514A

FOSC 400 B2/B4. Fiber Optic Splice Closures. Table of Contents. Page 1

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

FOSC-450 Product Range Ordering Guide

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

INSTALLATION INSTRUCTIONS

Panduit Recommended Best Case Practice Split Fibre

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

SLiC Fiber Aerial Closure System

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

Optical Distribution Box 300 Installation Guide. Version : R0.0

Extreme Density Networks Are You Ready?

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

3M Fiber Optic Splice Closure 2178-L/S Series with Gasket

18mm ECAM Cable Entry Port

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

3M Fiber Optic Wall Mount Enclosure 8430 Series

CATV Hybrid Fiber Coax Solution Guide

Keyed LC Connector Solution A LANscape Solutions Product

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

FusionLink Central Tube Ribbon Preparation & handling procedure

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

SOLO ADSS Short-Span Cables, Fibers

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

FOSC 400 C5 & D5 Fiber Optic Splice Closures

Public Works Division Lighting District Fiber Optic Specifications April 2009

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

SLICE6 3-CHANNEL SENSOR CONNECTOR ASSEMBLY DOCUMENT

3M Cold Shrink QS4 Integrated Splice Kit QS4-15SP-2-4/0

Crimp & Cleave Termination Instructions for SEL ST Connectors

2178-L/S Series Fiber Optic Splice Case with Gasket

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

The FiberMark1 offers an ideal solution for

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

2178 L/S Series Fiber Optic Splice Cases and Accessories

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

SUMITOMO RECOMMENDED PROCEDURE SRP SP-F Ribbon Indoor/Outdoor Riser Cable Preparation

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)

Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2

TECHNICAL SPECIFICATION

3M Distribution Box (DDB)

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

Aerospace Fiber Optics

Next Generation Frame (NGF) Fiber Combination Block (FCB) User Manual)

3A TC 699/SIP/UK/12

GCO2-BC6/16-MC-XV GCO2-BD6/16-MC-XV GCO2-BE6/16-MC-XV. 3.1 Installation of the workstand 3.2 Opening the FIST-GCO2

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

27mm ECAM Double Cable Entry Port

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

DIY. How to install a PL-259 connector. Parts list: Tools list: Worthwhile projects you can build on your own

Industrial Loadbreak Elbow

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

E2O6CMRXP-1T9 drop fiber leg preparation

Buffer Tube Midspan Access Tool Accessing fibers in buffer tube procedure

Mining and Petrochemical Fiber Optic Cables

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

Transcription:

Furcation of a Central Tube Ribbon, Gel-Free, Non-Armored, 96- to 192-Fiber Cable into an OSE-UD P/N 004-277-AEN Issue 1 related literature Search www.corning.com/opcomm. Click on Resources. 1. Initial Decisions 1.1 Measure Access Length Route a piece of braided mesh tubing ¼-in ID inside the Optical Splice Enclosure (OSE) following the path the fiber will take from the entry point to the splice tray location and measure the length as shown in Figure 1. Then add 4 ft to that measured length. This will be the cable access length. Write down the access length =. 2. Material Preparation 2.1 Kit Contents 2.1.1 HFC-FURC-KIT-C The kit contents are shown in Figure 2. TPA-5788 Figure 1 Figure 2 1. Ribbon funnel kit (1) 2. Heat-shrink tubing 34/7 X 160-mm (2) 3. Silicone DC 734 sealant (1) 4. Ribbon transport tubing (50 ft) 5. 3M 4460-D ground clamp (1) 6. Adhesive aluminum foil 100-mm X 250-mm (1) 7. 60 grit sandpaper (1) 8. Braided mesh tubing ¼-in ID (20 X 10 ft) 9. Heat-shrink tubing 13-mm ID X 2-in L (1) Standard Recommended Procedure 004-277-AEN Issue 1 June 2017 Page 1 of 6

2.2 Other Materials (not included in furcation kit) 2.3 Tools Viscous silicone with syringe applicator Electrical tape Masking tape Friction tape Book of electrical numbers Cable access tool: hook-blade, universal access tool (UAT3-000), large coaxial cutter Ribbon splitting tool (RST-000) 2.4 Cut Materials 90 percent or higher isopropyl alcohol Cable solvent or cleaner Shop towels 4-in cable ties Cable retention strap Scissors/snips Permanent marker black/silver Heat gun Extension cord Cut 3 piece(s) of ribbon transport tubing 5 in long as shown in Figure 3. Hold the ribbon transport tubing as flat as possible while cutting as it is subject to preferential bending. Cut braided mesh tubing ¼-in ID to access length measured in Section 1. Cut 3 pieces. 3. Cable Access Refer to Corning Optical Communication s Standard Recommended Procedures (SRPs) 004-072 for cable access and stripping instructions. Install cable and Cable Entry Kit into OSE per SRP 003-1032-AEN (Ultra-Density Optical Splice Enclosure) and SRP 003-1036-AEN (Cable Entry Kit OSE-UD). Mark the cable with the permanent marker at the access length measured in Section 1. Access the cable per the instructions in SRP 004-072. 4. Ribbon Splitting and Grouping 4.1 Ribbon Splitting If the cable only has 12-fiber ribbons proceed to the next section. Split ribbons into 12-fiber ribbons. Refer to SRP 004-098 for directions on using the ribbon splitting tool (RST-000). Figure 3 Use the ribbon splitting tool (RST-000) to split the 24-fiber or 36-fiber ribbons into 12-fiber ribbons for the first 6 in. Standard Recommended Procedure 004-277-AEN Issue 1 June 2017 Page 2 of 6

Step 4: Place your finger in between the two 12-fiber ribbons you want to split with one ribbon on top and one ribbon on the bottom of your finger. Then drag your finger between the ribbons towards the access point of the cable furthering the split between the ribbons. Alternate the ribbons on your finger about each foot or if you see the ribbon matrix peeling up, see Figure 4. 4.2 Ribbon Grouping Figure 4 As you group the ribbons it is recommended to keep the groups in the order that they come out of the cable. Notice how the ribbons form a stack and try to maintain this stack. This will be helpful during the furcation process later on. Group the ribbons into as many bundles of six ribbons as possible. Group any remaining ribbons together in the final bundle. Group in ascending order starting with ribbon 1 then 2 until you get to 6 for the first bundle. Bundle them together with masking tape as seen in Figure 5. Step 4: Step 5: Step 6: Figure 5 Continue grouping in groups of 6 until you have grouped all ribbon(s). Secure the end of each bundle with masking tape to preserve the ribbon order. Slide heat-shrink tubing 34/7 x 160 mm past cable jacket for use later in the process. Leave the cap off of ribbon funnel kit when installing it on the cable. Standard Recommended Procedure 004-277-AEN Issue 1 June 2017 Page 3 of 6

5. Furcation 5.1 Furcation Plug Step 4: If the cable is outside plant cable, use the 60 grit sandpaper to scratch up 1 in of the end of the cable jacket. Feed the ribbon bundles through the ribbon funnel kit and slide the ribbon funnel kit down so it overlaps with the cable jacket ½ in. If the ribbon funnel kit inside diameter is larger than the outside diameter of the cable, use electrical tape to build up the outside diameter of the cable jacket so the ribbon funnel kit fits on the cable jacket. Use electrical tape to secure the end of the ribbon funnel kit to the cable jacket. Step 5: Step 6: Insert the bundles of ribbon into the funnel cap in the positions shown in Figure 6. This ordering is required to prevent the ribbons from twisting inside the ribbon funnel kit which will induce binding and cause attenuation issues. Slide the funnel cap down the ribbons and press it into the ribbon funnel kit. The cable should now appear as in Figure 7. Figure 6 Figure 7 Step 7: Slide a piece of 5-in long ribbon transport tubing down the length of each ribbon bundle and insert it inside the cap. The cap may need to be taken out of the ribbon funnel kit for this step and then put back in when all the 5-in long ribbon transport tubing are inserted. The 5-in long ribbon transport tubing should extend ½ in inside the ribbon funnel kit as in Figure 8. Double check that there are no bends or twists on the ribbon(s) inside the ribbon funnel kit. Figure 8 Standard Recommended Procedure 004-277-AEN Issue 1 June 2017 Page 4 of 6

5.2 Furcation Bundling Slide a piece of braided mesh tubing ¼-in ID cut-to-access-length down the length of each ribbon bundle and over the 5-in long ribbon transport tubing. The braided mesh tubing ¼-in ID cut-to-accesslength should slide all the way down until the end is about 1 in from the ribbon funnel kit (Figure 9). Figure 9 Use electrical tape to tape the braided mesh tubing ¼-in ID cut-to-access-length to the 5-in long ribbon transport tubing (Figure 10). The 5-in long ribbon transport tubing may need to be pulled back out of the ribbon funnel kit one at a time to make it easier to apply the electrical tape Fill any empty holes in the funnel cap with silicone DC 734 sealant. 6. Cable Completion 6.1 Splice Trays Secure ribbon groups into OSE splice trays following the instructions per SRP 001-285 (OSE Splice Trays). Make sure the method used to secure the ribbons is covered by the mesh and then secured with electrical tape. Use 4-in cable ties to secure the ribbon groups into the splice trays. Take into account if splicing blue-blue or blue-aqua when positioning ribbons. Route ribbons in tray and label the tray for later reference. Figure 10 Standard Recommended Procedure 004-277-AEN Issue 1 June 2017 Page 5 of 6

6.2 Shrink the Tubing Starting from the base of the cable, use a heat gun to shrink the heat-shrink tubing 34/7 x 160-mm over the ribbon funnel kit as shown in Figure 11. Starting from one end and working all the way around the cable and moving to the other end of the heat-shrink. Use the adhesive aluminum foil 100-mm x 250-mm as a shield around the mesh to keep the heat from melting the mesh. Route the ribbon legs into the OSE per SRP 003-450 (Optical Splice Enclosure) (Figure 12), and place splice tray in the splice tray holder location. Secure ribbon legs with cable retention strap. Figure 11 For questions and comments about the procedures or contents of this document please call Corning Optical Communications Customer Service line at 1-800-743-2671 and ask for Technical Support. Figure 12 Corning Optical Communications LLC PO Box 489 Hickory, NC 28603-0489 USA 800-743-2675 FAX: 828-325-5060 International: +1-828-901-5000 www.corning.com/opcomm Corning Optical Communications reserves the right to improve, enhance, and modify the features and specifications of Corning Optical Communications products without prior notification. A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. 2017 Corning Optical Communications. All rights reserved. Standard Recommended Procedure 004-277-AEN Issue 1 June 2017 Page 6 of 6