ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

Similar documents
Electrical connection

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Electrical connection

Electrical connection

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Electrical connection

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Electrical connection

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Technical data. General specifications. Indicators/operating means

Amplifier for fiber optics. Dimensioned drawing

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines

Capacitive sensor BCT5-S18-UP6X2T-H1151

SU17 Series Fiber Optic Sensors

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Operating Instructions

Photoelectrics Through-beam Type PA18C.T..., DC

Amplifier for fiber optics. Dimensioned drawing

Sensor technologies Proximity sensors Series ST4. Brochure

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Your Global Automation Partner. Ultrasonic Sensors

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

ULTRASONIC. Distance and Proximity Sensors. UFP / UPA Series. Key-Features:

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Photoelectric sensor Photoelectric Sensor for Plastic Fibers DF-G1-KS-Q7

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

ultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

CML 700i Measuring light curtain with integrated control unit and interfaces for even simpler operation

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor NI10-M18-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

SERIES 400 SERIES 620

Photoelectric Sensors E3F2

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

SPECTRO Series. SPECTRO-1-30-UV/VIS-9x1. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

SPECTRO Series SPECTRO-1-50-DIL. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

SPECTRO Series SPECTRO-1-30-UV/UV. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

>Inductive. REFERENCE guide. Proximity

V 180 Series Photoelectric Switches

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

SPECTRO Series SPECTRO-3-50-COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:

Position transmitter SDAT-MHS NH [ ]

SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

SPECTRO Series SPECTRO-3-50-FCL-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-FCL-JR (incl. software SPECTRO3-Scope)

Transmitter optics with 9x white light LED (optics cover made of glass)

RLS Series RLS-GD-20/20 -UV. Design. RLS-GD Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

Safety Light Curtains GuardShield

WF next: Fork sensors for a wide range of applications

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Inductive sensor With analog output BI15-M30-LI-EXI

Operating instructions Electronic preset counter Type series 717

SPECTRO Series SPECTRO-3-50-UV-JR. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-UV-JR (incl. software SPECTRO3-Scope)

Absolute Encoders Multiturn

LUT Luminescence scanners: Seeing what no-one else can

Inductive Proximity Switches. Sensing Distance mm. Itemgroup 230

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

>Inductive and. REFERENCE guide. Capacitive Sensors

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

SPACESCAN SERIES SS 02

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

W100L: Laser Sensor in Mini- Format

Position transmitter SDAT-MHS f [ ]

W 9-2: A Versatile, Complete and Compact Series

BMOA Component Systems. Miniature Optical Sensors. c Features. Technical Description

Sensor technologies Distance measuring sensors Series SM6. Brochure

Q3X Laser Contrast Sensor

LD OEM/LD PDS/LD PeCo

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

Process transmitter RMA422

Transcription:

ADVANCED ultrasonic sensors with analog output Dimensioned drawing en 07-2017/02 50124880 4...20 ma 0...10 V 25 400mm 150 1300mm 15-30 V DC We reserve the right to make changes PAL_DMU418BX3LTVC_en_50124880.fm Function largely independent of surface properties, ideal for detection of liquids, bulk materials, transparent media, Small dead zone at long scanning range Temperature-compensated scanning range and measurement range 1 PNP switching output (NPN) and 1 analog output 0 10V / 4 20mA NEW Both outputs can easily be taught using a button NEW Stable, all-metal design NEW Process data and configuration via IO-Link interface NEW Five operating modes: scanning, synchronous, multiplex, activation and throughbeam operation Accessories: (available separately) IP 67 IEC 60947... IEC 60947... IP 68 Mounting systems Mounting adapter M18-M30: BTX-D18M-D30 (Part no. 50125860) Cables with M12 connector (K-D ) Teach adapter PA1/XTSX-M12 (Part no. 50124709) USB IO-Link master 2.0 (Part no. 50121098) A Control button 2 B Control button 1 C Indicator diodes D Active sensor surface Electrical connection DMU418B- X3/LTV-M12 DMU418B- X3/LTC-M12 Factory setting for pin 2 multi funct: teach input Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 info@leuze.com www.leuze.com DMU418B- X3/LT -M12-07

Specifications Ultrasonic specifications DMU418B-400.X3/ DMU418B-1300.X3/ Scanning range 1) 25 400mm 2) 150 1300mm 3) Adjustment range 25 400mm 150 1300mm Ultrasonic frequency 310kHz 200kHz Typ. opening angle 9 16 Resolution switching output 0.5mm 1mm Resolution analog output 0.1mm 0.1mm Direction of beam axial axial Accuracy (analog output) ± 0.5% of end value 1) ± 0.5% of end value 1) Reproducibility ± 0.15% of end value 1) ± 0.15% of end value 1) Switching hysteresis (OUT1) 5 mm 10mm Temperature drift ± 1.5% of end value 1) ± 1.5% of end value 1) operating modes IO-Link COM2 (38.4kBaud) SIO is supported Timing Switching frequency 7Hz 8Hz Response time 71ms 62ms Delay before start-up < 300ms < 300ms Electrical data Operating voltage U 4) B SIO mode: 15 30V DC (incl. ± 10% residual ripple), COM2 mode: 18 30V DC (incl. ± 10% residual ripple) Residual ripple ± 10% of U B Open-circuit current 50mA Switching output OUT1: 1 x PNP transistor output, IO-Link SIO mode Function (PNP) NO contact, reversible Output current SIO mode: max. 150mA per contact, COM2 mode: max. 100mA per contact Switching range adjustment OUT1: control button 1 or teach input Changeover NO/NC OUT1: control button 1 or teach input Analog output X3/LTV voltage output 0 10V, teachable, configurable, X3/LTC current output 4 20mA, teachable, configurable Error signal (analog output) distance too small: 3.8mA, distance too large: 11V / 21mA Indicators Yellow LED OUT1: object detected Yellow LED, flashing teach-in / teaching error for 1-point teach / cable short circuit Green LED object within the scanning range Green LED flashing IO-Link communication Yellow and green LEDs flash teach-in/teaching error for window-teach Mechanical data Housing all metal - brass, nickel-plated Weight 50g Ultrasonic transducer piezoceramic 5) Connection type M12 connector, 5-pin Fitting position any Environmental data Ambient temp. (operation/storage) -25 C +70 C/-30 C +85 C Protective circuit 6) 1, 2, 3 VDE safety class III Degree of protection IP 67 and IP 68 Standards applied EN 60947-5-2 Certifications UL 508, C22.2 No.14-13 4) 7)8) 1) At 20 C 2) Target: 20mm x 20mm plate 3) Target: 100mm x 100mm plate 4) For UL applications: for use in class 2 circuits according to NEC only 5) The ceramic material of the ultrasonic transducer contains lead zirconium titanate (PZT) 6) 1=short-circuit and overload protection, 2=polarity reversal protection, 3=wire break and inductive protection 7) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5A min, in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7); Use tool for buttons 8) Ambient temperature 85 C. Use same voltage supply for all circuits. Diagrams DMU418B-400 -M12 Width y of the sound cone [mm] Width y of the sound cone [mm] Typ. response behavior (plate 20x20mm) 150 100 50 0-50 -100 y2 y1-150 0 100 200 300 400 500 Object distance x [mm] Typ. response behavior (rod Ø 27mm) 150 100 50 0-50 -100 y2 y1-150 0 100 200 300 400 500 Object distance x [mm] DMU418B-1300 -M12 Width y of the sound cone [mm] Width y of the sound cone [mm] Width y of the sound cone [mm] Typ. response behavior (plate 20x20mm) 300 200 100 0-100 -200-300 0 200 400 600 800 1000 1200 1400 Object distance x [mm] 200 100 0-100 -200-300 0 200 400 600 800 1000 1200 1400 Object distance x [mm] y2 y1 Typ. response behavior (plate 100x100mm) 300 200 100 0-100 -200-300 0 200 400 600 800 1000 1200 1400 Object distance x [mm] y2 y1 Typ. response behavior (rod Ø 27mm) 300 Target (fixed): plate or rod Object distance [mm] y2 y1 Sound cone = f (α,x) Remarks Operate in accordance with intended use! This product is not a safety sensor and is not intended as personnel protection. The product may only be put into operation by competent persons. Only use the product in accordance with the intended use. DMU418B- X3/LT -M12-07 2017/02

ADVANCED ultrasonic sensors with analog output Part number code D M U 4 1 8 B - 1 3 0 0. X 3 / L T V - M 1 2 Operating principle HTU Ultrasonic sensor, scanning principle, with background suppression DMU Ultrasonic sensor, distance measurement Series 418B 418B Series, cylindrical M18 construction Scanning range in mm 400 25 400 1300 150 1300 Equipment (optional) X "Advanced" design 3 Teach button on the sensor Pin assignment of connector pin 4 / black cable wire (OUT1) 4 PNP output, NO contact preset P PNP output, NC contact preset L IO-Link communication or push-pull (SIO) Pin assignment of connector pin 2 / white cable wire (Teach-IN) T Teach input Pin assignment of connector pin 5 / gray cable wire (OUT2) 4 PNP output, NO contact preset P PNP output, NC contact preset V Analog voltage output 0 10V C Analog current output 4 20mA X Connection not assigned (n. c.- not connected) Connection technology M12 M12 connector, 5-pin Order guide The sensors listed here are preferred types; current information at www.leuze.com. Designation Part no. Scanning range / Analog output 25 400mm / 0 10V DMU418B-400.X3/LTV-M12 50124261 25 400mm / 4 20mA DMU418B-400.X3/LTC-M12 50124260 150 1300mm / 0 10V DMU418B-1300.X3/LTV-M12 50124264 150 1300mm / 4 20mA DMU418B-1300.X3/LTC-M12 50124263 Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 DMU418B- X3/LT -M12-07 info@leuze.com www.leuze.com

Device functions and indicators switching output The sensor has two buttons for adjusting switching output OUT1 and analog output OUT2. Alternatively, all adjustments can also be made via IO-Link. The multi funct teach input can be used to perform the 1-point teach and the changeover of the switching function (NO contact/nc contact). Switching output OUT1 1-point teach (1 switching point) Switching behavior NO contact Switching behavior NC contact DMU418B Switching point Switching point green LED ON Distance green LED ON Distance Scanning range Scanning range 2-point window-teach (2 switching points) Switching behavior NO contact Switching behavior NC contact Switching point 1 Switching point 2 Switching point 1 Switching point 2 green LED ON green LED ON Distance green LED ON Distance Scanning range Scanning range Notice! The switching behavior is not defined in the dead zone. Switching behavior with 2-point window-teach as a function of the switching function Switching function configured as First taught object distance Second taught object distance Output switching behavior NO contact NC contact Far Close Close Far Notice! In measurement operation, the yellow and green LED only indicate the behavior of output OUT1. The behavior of output OUT2 is not indicated. DMU418B- X3/LT -M12-07 2017/02

ADVANCED ultrasonic sensors with analog output Adjustment of the switching points (Teach) using the control buttons The switching point of the sensor is set to 400mm or 1300mm (static 1-point teach) on delivery. By means of a simple operating procedure, the switching point for output OUT1 can be individually taught to an arbitrary distance within the scanning range with 1-point teach (static) or 2-point window-teach (static). Moreover, the output function can be switched from NO contact (NO - normally open) to NC contact (NC - normally closed). For the adjustment, control button 1 is permanently assigned to output OUT1 (see dimensioned drawing). 1-point teach (static) 2-point window-teach (static) 1) 1. Place object at desired switching distance. 1. First, place object at desired switching distance for switching point 1. 2. To adjust output OUT1, press button 1 for 2 7s until the yellow LED 2. To adjust output OUT1, press button 1 for 7 12s until the yellow and flashes at 3Hz. green LED flash alternately at 3Hz. 3. Release the button at the end of the teach event. 3. Release button. The sensor remains in teach mode and the LEDs continue The current object distance has been taught as the new switching point. to flash. 4. Error-free teach: LED states and switching behavior according to the diagram 4. Then, place the object at the desired switching distance for switching shown above. point 2. Faulty teach (object may be too close or too far away please note scanning Notice: The minimum distance between the switching points is as follows: range): scanning range of 400mm: 40mm scanning range of 1300mm: 130mm yellow LED flashes at 5Hz until an error-free teach event is performed. The affected output is inactive as long as there is a teach error. 5. Briefly press the button again at the end of the teach event. The switching window has been taught. 6. Error-free teach: LED states and switching behavior according to the diagram shown above. Faulty teach (object may be too close or too far away please note scanning range): green and yellow LED flash at 8Hz until an error-free teach event is performed. 1) See table "Switching behavior with 2-point window-teach as a function of the switching function" Adjustment of the switching function (NO/NC) using the control buttons Control button 1 can be used to switch the switching function of output OUT1 from NO contact to NC contact (or vice versa). To do this, proceed as follows: Action / Description Changeover of the switching function: Switching output OUT1 is set as NO contact ex works. If the switching function is changed, the switching output is changed to the opposite state (toggled). Control button Press button 1 of the switching output for longer than 12s. Indicator diode GREEN YELLOW Both LEDs flash alternately for a short time at 3Hz. If the yellow LED is then ON, the output functions as an NO contact. If the yellow LED is then OFF, the output functions as an NC contact. Notice! For 2-point window-teach, the switching behavior is dependent on the selected object distances for switching points 1 and 2. See previous page! Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 DMU418B- X3/LT -M12-07 info@leuze.com www.leuze.com

Device functions analog output Analog output OUT2 Rising characteristic curve Falling characteristic curve Error 11V 21mA Start point 0V 4mA Measurement range End point 10V 20mA Error 11V 21mA Start point 10V 20mA Measurement range End point 0V 4mA Error 3.8mA Error 3.8mA Object distance Object distance Close error: Object outside of the measurement range Remote error: Object outside of the measurement range Close error: Object outside of the measurement range Remote error: Object outside of the measurement range Characteristic curve behavior as a function of the object distances for start/end of measurement range Characteristic curve configured as First taught object distance Second taught object distance Characteristic curve of the analog output Rising characteristic curve Close Far Falling characteristic curve Far Close Notice! In measurement operation, the yellow and green LED only indicate the behavior of output OUT1. The behavior of output OUT2 is not indicated. DMU418B- X3/LT -M12-07 2017/02

ADVANCED ultrasonic sensors with analog output Adjustment of the analog output (Teach) using the control buttons The choice of distances for start of measurement range and end of measurement range can be used to adjust the characteristic curve of the analog output. If an object is located outside of the taught measurement range, an error signal is output. A different analog signal is output here by the sensor for the errors "distance too close: object outside of the measurement range" and "distance too far: object outside of the measurement range". Rising characteristic curve 1) Falling characteristic curve 1) 1. Place object at desired distance for the start point of the measurement 1. Place object at desired distance for the end point of the measurement range. range. 2. To adjust analog output OUT2, press button 2 for 7 12s until the 2. To adjust analog output OUT2, press button 2 for 7 12s until the yellow and green LED flash alternately at 3Hz. yellow and green LED flash alternately at 3Hz. 3. Release button. The sensor remains in teach mode and the LEDs continue 3. Release button. The sensor remains in teach mode and the LEDs con- to flash. tinue to flash. 4. Then, place object at desired distance for the end point of the measurement 4. Then, place object at desired distance for the start point of the mea- range. surement range. Notice: The minimum distance between the start and end point of the measurement range is as follows: scanning range of 400mm: 40mm scanning range of 1300mm: 130mm 5. Briefly press the button again at the end of the teach event. The characteristic curve with rising curve has been taught. 6. Error-free teach: LED states acc. to table under "Device functions and indicators". Faulty teach: green and yellow LEDs flash at 8Hz until an error-free teach is performed. 1) See table "Characteristic curve behavior as a function of the object distances for start/end of measurement range" Notice: The minimum distance between the start and end point of the measurement range is as follows: scanning range of 400mm: 40mm scanning range of 1300mm: 130mm 5. Briefly press the button again at the end of the teach event. The characteristic curve with falling curve has been taught. 6. Error-free teach: LED states acc. to table under "Device functions and indicators". Faulty teach: green and yellow LEDs flash at 8Hz until an error-free teach is performed. Adjusting the sensor via the teach input multi funct connection pin 2 is configured ex works as a teach input. Via the teach input, you can - lock the control buttons. - perform a 1-point teach (static) of the switching output. - perform a 2-point window-teach (static) of the switching output. - perform a 2-point teach of the characteristic curve of the analog output. LOW signal level 0.191 U B or not connected Signal level HIGH 0.809 U B Locking of the control buttons Action Locking the control buttons Unlocking the control buttons Pin 2 (multi funct) HIGH signal (permanent) LOW signal or not connected (permanent) Description As long as the HIGH signal is continuously applied, the sensor cannot be adjusted with the control buttons. The control buttons of the sensor are disabled. As long as the LOW signal is continuously applied or pin 2 remains unconnected, the sensor can be adjusted with the control buttons. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 DMU418B- X3/LT -M12-07 info@leuze.com www.leuze.com

Teach of switching output and analog output Switching point 1 Switching point 2 U Teach HIGH Buttons locked U Teach LOW t Teach1 t Teach2 t Buttons can be operated After the delay before start-up ( 300ms) has elapsed, the control buttons of the sensor can be operated. 20ms Pulse duration t Teach1 Pulse duration t Teach2 20 ms 1-point teach (static) 20ms Switching output OUT1: t Teach1 = 20 80ms Place object. The current object distance is taken over as switching point 1 with the rising edge of t Teach2. Do not change the object distance! The falling edge of t Teach2 ends the teach event. 2-point window-teach (static) Switching output OUT1: t Teach1 = 120 180ms Analog output OUT2: t Teach1 = 120 180ms Place object. The current object distance is taken over as switching point 1 with the rising edge of t Teach2. remains in teach mode. Change the object distance now! The current object distance is taken over as switching point 2 and the teach event is ended with the falling edge of t Teach2. 2-point teach of analog characteristic (static) Place object. The current object distance is taken over as the start point of the measurement range with the rising edge of t Teach2. remains in teach mode. Change the object distance now! The current object distance is taken over as the end point of the measurement range and the teach event is ended with the falling edge of t Teach2. Notice! The procedure is identical for the 2-point window-teach for switching output OUT1 and for the 2-point teach of the characteristic curve of analog output OUT2 via the teach input. The characteristic curve and switching window can only be adjusted independently via the control buttons or the IO-Link interface. The changeover of the switching function (NC contact/no contact) and the characteristic curve (rising/falling) is not possible via the teach input. DMU418B- X3/LT -M12-07 2017/02

ADVANCED ultrasonic sensors with analog output IO-Link interface The ultrasonic sensor features an IO-Link interface acc. to specification V1.1. and satisfies the Smart Profile. As a result, the sensor can easily, quickly and, thus, economically be configured and diagnostic information read out. With a small amount of effort, the sensor can also be integrated in a control. Overview of the configuration options via IO-Link Function block Function Description Operating mode Standard operation The sensor operates as a scanner with background suppression. Multiplex operation A max. of 10 sensors 1 master and 9 slaves can be wired together in a network. To do this, the sensors must be electrically connected with one line. The master generates a timing signal and all networked sensors are activated with time-delay. Synchronous operation A max. of 10 sensors 1 master and 9 slaves can be wired together in a network. To do this, the sensors must be electrically connected with one line. The master generates a timing signal and all networked sensors are activated simultaneously. Activation operation The sensor can be activated through an external signal. Operation as throughbeam sensor The sensor can either be configured as a scanner or as a throughbeam sensor. Operation as a throughbeam sensor requires 2 sensors, which are electrically connected through one line. Switching output Switching point 1/2 The switching points can be directly entered as distance value in mm. OUT1 Switching output (OUT1 and OUT2) Adjustment as PNP or NPN switching output Switching function Adjustment as NC / NO contact. Switching behavior in the case of error The switching behavior of output OUT1 of the sensor, for objects which are located outside of the scanning range, can be adjusted. 2-point behavior If a switching output is to operate with 2 switching points, a choice can be made between 2-point window-teach (factory setting) or 2-point teach (e.g. for simple pump controls with minimum and maximum fill levels). Teach switching output OUT1 The switching output OUT1 can be taught via the IO-Link interface. Teach lock Adjustment for locking of control buttons Analog output OUT2 Analog start value The distance for the start point of the measurement range can be entered directly in mm. Analog end value The distance for the end point of the measurement range can be entered directly in mm. Direction of the characteristic curve Configuration option for rising or falling characteristic curve. Value range For devices with voltage output: 0 10V (factory setting); 0 5V; 1 6V. For devices with current output: 4 20mA (factory setting); 0 20mA. Temperature Temperature compensation Adjustment option for internal (sensor works with the integrated temperature sensor) or external (with a constant application temperature, this can be manually entered. The sensor then compensates the measured values at a fixed rate with this temperature). Unit Adjustment option to ºC or ºF. Temperature value Entry temperature value in ºC or ºF (if external temperature compensation is desired). In addition to the configuration functions, a range of sensor information, such as sensor status, sensor diagnostics as well as the process data, can be called up. Further information and the device-specific description of the IO-Link interface (IODD) can be found on the Internet at www.leuze.com in the Downloads area of the respective sensor. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 DMU418B- X3/LT -M12-07 info@leuze.com www.leuze.com

DMU418B- X3/LT -M12-07 2017/02