Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

AC1036. Definite Purpose Contactors

Series CDP2 Definite Purpose Contactors

Series CDP2 Definite Purpose Contactors

Data Sheet Definite Purpose Contactors Ex9CK Series

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

Definite Purpose Contactors

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

AS09..S 3-pole Contactors - Spring Terminals

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Series CT7N Bimetallic Overload Relays

Magnecraft Power Relays

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Magnetic and Hydraulic-Magnetic Circuit Breaker

Minicontactorrelay,2NO/2NC,DCoperated

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Bulletin 190 IEC Modular Starter System

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Bulletin 100-G IEC Contactors

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Type: DILM25 10(24V50HZ) Article No.:

Features XT SC 012 B B A

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

Features XT SC 012 B B A

SQM40/41 Actuators for air and gas dampers

MILLITARY SPECIFICATION SHEET

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

GR circuit breaker - hydraulic magnetic, Datasheet

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

ALLEN BRADLEY TIMING RELAY

Part-Turn Electric Multi-Turn Electric

59.1. Motor Control and Protection. For Immediate Delivery or Tech Support call KMParts.com at (866) Product Overview.

Dimensions and Weight Size 2.79 HEIGHT X 1.6 WIDTH X 1.19 DEPTH IN, HEIGHT X WIDTH X DEPTH MM

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Bulletin 100-G IEC Contactors

GR circuit breaker - hydraulic magnetic, Datasheet

XT IEC Power Control Combination Motor Controllers

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

Power Circuit of a UL508A Panel. Typical UL489 Application

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Type: DILM12 10(24VDC) Article No.:

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Modular Lube Lubrication Systems System Controls

INCH-POUND MIL-PRF-55629/21G 10 March 2010 SUPERSEDING MIL-PRF-55629/21F 21 September 2005 PERFORMANCE SPECIFICATION SHEET

XT Line Replacement Coils 16.1 NEMA Contactors and Starters Freedom Line... A200 Line IEC Contactors and Starters XT Line...

Type Contact form Model

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Power Transformers & High Frequency Magnetics Your one source for all your magnetics needs!

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

llen-bradley 194R-HM4-NFPA3

Product Data Sheet 4656 ZW

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

A V 50Hz / V 60Hz

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Product Data Sheet 8506 VW-691

High performance circuit breakers

Ultra Quiet Series Electric Air Handler

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

TeSys circuit-breakers

Bulletin 190 Compact. Combination Starters

30 mm Push Buttons 9001 K and SK Selector Switches

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Single Point Flow Monitor SW118 SW119

Features. Specifications. Finish. Notes

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

Pluggable interface relays CR-M Miniature relays

Split System Air Conditioner

MaxiBridge mm Connectors. Ed Full-scale MaxiBridge 8 Pins Catalog E

Cast Aluminum Circuit Breaker Interlocked Receptacle (Cutaway View)

Bulletin 305 AC Starters

30 mm Push Buttons 9001K and SK Selector Switches

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Transcription:

11 Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business machines Resistive heating Air conditioning Refrigeration equipment Welding Agency approvals UL 508 Guide No. NLDX2, File # E224401 CE/Semko Certified EN60947-4-1:1991 IEC 947-4-1 Features Available as: 30A, 1, 2, 3 or 4 pole 40A, 2, 3 or 4 pole 60A, 3 pole Industry standard mounting plate provides easily accessible mounting holes Coil terminals are provided with #6-32 screws and (1).250 quick connect or dual.250 quick connect terminals Exclusive hex, slotted, phillips #10-32 terminal screws for main terminals Coil is Class B (130 C) Insulation system with wide range of voltages and 50/60 Hz ratings Double E Magnet Assembly provides optimal performance with reduced power consumption Snap-in auxiliary switch with 1 SPDT or 2 SPDT contacts available as an option 1 NO & 1 NC auxiliary contact block with 600 VAC rating available as an option Base assembly is made from high arc-resistant plastic Catalog number explanation DP 30 C 3P - 1 /B Frame size 30 = 30A 40 = 40A 60 = 60A Bulk pack quantities Coil voltage (See coil voltage selection chart) Power poles 1P = 1 NO 2P = 2 NO 3P = 3 NO 4P = 4 NO Contactor type C = Non-reversing Low Voltage Products & Systems 1.97

11 30A, 40A & 60A 30A, 40A & 60A DP30C3P-F DP40C4P-F DP60C3P-F Locked rotor amps Maximum HP Maximum HP Full Number 1 phase 3 phase Bulk Catalog Individual Bulk load of Resistive 240/ 200/ 240/ pack number pack pack amps poles amps qty. list price list price 277V 480V 600V 120V 240V 208V 277V 480V 600V 1 30 1 150 75 50 40 1 2 50 DP30C1P-F $ 30 $ 27 30 2 150 125 100 40 2 3 50 DP30C2P-F 38 34 30 3 180 150 120 40 2 5 10 10 15 20 25 DP30C3P-F 55 50 30 4 180 150 120 40 2 5 10 10 10 20 DP30C4P-F 75 68 40 2 240 200 160 50 2 3 50 DP40C2P-F 46 42 40 3 240 200 160 50 3 7.5 10 10 20 25 25 DP40C3P-F 60 54 40 4 240 200 160 50 3 7.5 10 10 10 20 DP40C4P-F 100 90 60 3 360 300 240 75 2 10 25 25 30 30 10 DP60C3P-F 147 140 Coil voltage selection chart Voltage 24VAC 120VAC 208/240VAC 277VAC 480VAC 575VAC Suffix # F 1 2 C 4 5 Coil voltage selection All catalog numbers include a 24VAC coil. To select other coil voltages, substitute the code from the Coil Voltage Selection Chart for the first digit after the dash in the catalog number. Auxiliary contact blocks (3 pole only) Catalog Catalog List Description number number price 30A - 40A 60A NO or NC SPDT CADP40-10 CADP60-10 1 NO & 1 NC CADP40-11 $ 10 Ordering bulk quantities To order bulk package quantities add /B to the end of the catalog number. Example: For quantities of 25 of a 30A 3 pole contactor with 24VAC coil, the catalog number would be: DP30C3P-F/B Mechanical interlock Frame Catalog List size number price DP30 DP40 VMDP-1 $ 7 Contact rating of 1 NO & 1 NC Contact rating of SPDT Voltage Current rating 125VAC 10A, 1/3 HP 120VAC 4A on lamp load 250VAC 10A, 1/3 HP 125VDC.5A 250VDC.25A 120V 240V 480V 600V Break A 3.0 1.5.75.6 Make A 30 15 7.5 6 Continous A 10 10 10 10 Quick connect terminals on all auxiliary switches are.250 wide. 1 Must be ordered in standard pack quantities as shown. Add suffix /B to the catalog number. 1.98 Discount schedule DP Low Voltage Products & Systems

Technical data 30A 60A 1, 2, 3, & 4 Pole 11 30A 40A 1 & 2 pole Coil technical data DP30C1P DP30, DP40C2P Nominal coil voltage 24 120 208/240 277 24 120 208/240 277 Maximum pickup volts 18 88 177 221 18 88 177 221 Drop-out volts range 6 15 20 70 40 170 50 165 6 15 20 70 40 140 50 165 Nominal inrush VA 50 Hz 31 31 35 31 22 22 22 22 Nominal inrush VA 60 Hz 28 28 32 28 20 20 20 20 Nominal sealed VA 50 Hz 6 6 7 6 5.5 5.5 5.5 5.5 Nominal sealed VA 60 Hz 5 5 6 5 4.5 4.5 4.5 4.5 Nominal DC resistance Ohms 17.5 450 1800 2252 13 275 1056 1772 Other specifications DP30C1P DP30, DP40C2P Line and load terminals # 10 32 screw 1 Box lug 1 Wire size AWG min max 16 82 14 4 Cu/Al Tightening torque (recommended) 25 in. lbs. 40 in. lbs Coil termination Dual.250 QC (2) Dual.250 QC (2) Quick connects.250 std. 1 1.5 pole Quad Quad Quick connects.250 std. 2 pole Dual or quad Dual or quad Covers Optional Standard Insulation system 130 C Class B 130 C Class B 30A- 60A 3 pole Coil technical data DP30, DP40C3P DP60C3P Nominal coil voltage 24 120 208/240 277 480 24 120 208/240 277 480 Maximum pickup volts 18 88 177 220 384 18 93 177 235 374 Drop-out volts range 6 15 20 70 40 140 65 185 150 270 6 15 20 70 40 135 50 180 150 286 Nominal inrush VA 50 Hz 65 65 65 65 65 140 140 140 140 140 Nominal inrush VA 60 Hz 60 60 60 60 60 132 132 132 132 132 Nominal sealed VA 50 Hz 7.5 7.5 7.5 7.5 7.5 20 20 20 20 20 Nominal sealed VA 60 Hz 6 6 6 6 6 14 14 14 14 14 Nominal DC resistance Ohms 6.6 165 660 880 1320 2.4 45 180 280 852 Other specifications DP30C3P DP40C3P DP60C3P Line and load terminals # 10 32 Screw 1 Box lug 1 Box lug 1 Wire size AWG min max 16 8 2 14 7 Cu/Al 14 2 Cu/Al Tightening torque (recommended) 25 in. lbs 40 in.lbs 50 in. lbs Quick connects: power terminals Dual.250 QC Dual.250 QC Dual.250 QC Coil terminals Dual.250 QC (2) Dual.250 QC (2) #6 35 screw &.250 QC (2) Covers Optional Standard Standard Insulation system 130 C Class B 130 C Class B 130 C Class B 30A 40A 4 Pole Coil technical data DP30, DP40C4P Nominal coil voltage 24 120 208/240 277 480 Maximum pickup volts 19.2 88 177 220 384 Drop-out volts range 6 15 20 70 40 140 65 185 150 270 Nominal inrush VA 50 Hz 68 68 58 58 48 Nominal inrush VA 60 Hz 60 60 55 52 52 Nominal sealed VA 50 Hz 14 14 11 11 11 Nominal sealed VA 60 Hz 9 9 9.5 9.5 9 Nominal DC resistance Ohms 5 148 550 750 2100 Other specifications DP30C4P DP40C4P Line and load terminals # 10 32 screw 1 Box Lug Wire size AWG Min Max 16 8 2 14 4 Cu/AL Tightening torque (recommended) 22 in. lbs 40 in. lbs Quick connects: power terminals Dual.250 QC Dual.250 QC Coil terminals Dual.250 QC (2) Dual.250 QC (2) Covers Optional Standard Insulation system 130 C Class B 130 C Class B 1 See page 1.82 to 1.85 for description and approximate dimensions. 2 Stranding must be split for #8 wire. Low Voltage Products & Systems 1.99

11 Approximate dimensions 30A 1, 2 & 3 Pole 00.00 00.00 Inches [Millimeters] DP30C1P 3.30 84 2.31 59.87 21 1.62 41 2.44 62 1.62 41 2.00 51 Ø.21 TYP. 4 5 DP30C2P 3.30 84 2.31 59.87 21 1.62 41 2.44 62 1.62 41 2.00 51 Ø.21 TYP. 4 5 DP30C3P 2.98 76 3.09 78 2.41 61.203 5 2.00 51.203 6 3.39 86 Auxiliary contact 3.75 95 3.25 83 3.12 79.203 5 2.41 61 1.100 Low Voltage Products & Systems

00.00 00.00 Inches [Millimeters] Approximate dimensions 30A 4 Pole 40A 2 & 3 Pole 11 DP30C4P DP40C2P DP40C3P Low Voltage Products & Systems 1.101

11 Approximate dimensions 40A 4 Pole 60A 3 Pole DP40C4P DP60C3P 1.102 Low Voltage Products & Systems

Approximate dimensions Terminations 11 Screw Lugs Standard on DP30 Standard on DP40 Standard on DP60 14-4AWG,Cu/Al 0.25 6 14-2AWG, Cu/Al 0.32 8 # 10-32 Combination Phillips, slotted & 5/16 Hex Head Low Voltage Products & Systems 1.103

11 Notes 1.104 Low Voltage Products & Systems