Operating pressure should be 6000 psi or better suitable for both analytical and semi-preparative applications

Similar documents
ICS-3000 System Installation Qualification

HPLC Tips and Tricks. Tiziana Ladisa Sales Support Specialist for Chromatography Italy Thermo Fisher Scientific, Rodano (MI)

Tender Notification for the procurement of a Scanning Electron Microscope" at IISc (Last Date for submission of tenders: 3 rd October 2018)

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Speed Performance Reliability. Medicinal Chemistry Natural Products Peptides & Polymers Organic Synthesis Purifications

Achieving More Efficient Data Review with OpenLAB CDS

ChromQuest 5.0 Chromatography Data System

Control Unit CU 2.1 User Manual V6850A HPLC

Liquid Chromatography- Mass Spectrometer Manual

PAL LSI - Robust and Reliable Sample Handling

PAL LSI - Robust and Reliable Sample Handling

LC-4000 Series. Integrated HPLC and UHPLC systems

Performance. Reliability. Productivity. Automated Flash Chromatography Systems

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

Online Process Control using Modular Fluid Delivery and Fast Process Gas Chromatography: From the Sample Point to the DCS Connection

ABB MEASUREMENT & ANALYTICS. MB3600 The most reliable FT-NIR laboratory analyzer designed for QA/QC

Technical Note. High-speed Agilent 1100 Series diode-array detector SL for optimization of resolution, sensitivity, spectral sensitivity and linearity

ABB MEASUREMENT & ANALYTICS. MB3000 The most reliable FT-IR laboratory analyzer

Monitor QA Management i model

Delivery, installation, commissioning and warranty of multi-channel Programmable High Voltage Supply System

Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer

If you have questions or problems in providing anything described as Customer

Customer Responsibilities. Important Customer Information. Agilent 1260 Infinity Clinical ed. LC Site Preparation Checklist

LAUREL ELECTRONICS, INC.

Advanced Test Equipment Rentals ATEC (2832)

Instrument Control and Data Acquisition with Chromeleon

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

BR2517B. 168 Diode Array & 166 Programmable Detector Modules. Packaging Processing. Bid on Equipment

potentiostat/galvanostat

GCxGC Comprehensive Two-Dimensional Gas Chromatography

GCxGC Comprehensive Two-Dimensional Gas Chromatography

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

Operating Instructions

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

Operation Manual for the Refractive Index detector VE-3580

Model KT 53 Cooling incubators with thermoelectric cooling

Request for Proposals

UNIGAS Hand-held combustion gas analyzer with 3 sensors

EXPRESSION OF INTREST

Detailed Design Report

800 Displaying Series Flowmeter

Our History. Experience since Today

Corporate Headquarters Dionex Corporation 1228 Titan Way P.O. Box 3603 Sunnyvale, CA Tel: (408) Fax: (408)

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

KENYA ELECTRICITY GENERATING COMPANY PLC. KGN-HYD

4 MHz Lock-In Amplifier

Our Mission. Towards the future

More reliable zeta potential measurements. without dilution. Agilent Particle Analysis Solutions. Agilent 7020 ZetaProbe Zeta Potential Analyzer

AIM INTRODUCTION SIMPLIFIED WORKFLOW

SPECIFICATION NO NOTE

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

Procurement of IC TESTER & TRAINER KITS, OSCILLOSCOPES, FG S, DECADE BOXES AND ANALOG METERS

SPECIFICATION NO Model 207 Automatic GTAW Welding System

BUREAU OF ENERGY EFFICIENCY

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

FLOMAT Electromagnetic Insertion Flowmeter

Introduction to System Suitability Tests Michael Wright Bioanalytical Services LGC Fordham, UK

Quick Start Operating Instructions

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Ranger Simplifying Even the Most Complex Industrial Applications. Compact Bench Scales. Standard Features Include:

Model 4700 Photodiode Characterizer

Model KT 115 Cooling incubators with thermoelectric cooling

SmartMix Manual V5350A

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Table of Contents. Amplifiers Broadband Telecommunications Line Extender [BLE-75**] FEATURES

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

IKA Analytical line Calorimeters C 2000

The extremely compact laser head is approximately 480 mm long and can

Tekna evo. innovation technology future 03

STANDARD OPERATING PROCEDURE:

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

m RSC Chromatographie Integration Methods Second Edition CHROMATOGRAPHY MONOGRAPHS Norman Dyson Dyson Instruments Ltd., UK

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

AU5800 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU5800 Weekly (Analyzer and ISE) Maintenance

INSTRUCTIONS TO BIDDERS

General Specifications

Magnetic Stirrers Magnetic Stirr

Modular Lube Lubrication Systems System Controls

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Humidity and Temperature Controllers (Product Code To ) DTH-966 with HYGROTX

Model KBF 115 Constant climate chambers with large temperature / humidity range

2 MHz Lock-In Amplifier

Model KBF P 240 Humidity test chambers with ICH-compliant light source

SAN ANTONIO WATER SYSTEM CENTRAL WATER INTEGRATION PIPELINE TERMINUS TREATMENT FACILITY SAWS Job No SAWS Solicitation No.

Agilent High Capacity RV Pumps & Roots Pumping Systems

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

s w i t c h i n g c o n t r o l l i n g c o u n t i n g

OPTICAL POWER METER WITH SMART DETECTOR HEAD

Tender Notification for the procurement of a "Dual beam (FIB - FE SEM) system" at IISc (Last Date for submission of tenders: 31st March 2016)

FLIR Daylight and Thermal Surveillance (P/T/Z) Multi-Sensor systems

GFT Channel Digital Delay Generator

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Ultimate quality control. No compromise. PROCESS / QUALITY CONTROL

Transcription:

S. No. NIPER-G/PUR/GLOBAL/2018/01 Technical Specification for Analytical HPLC with PDA & Fluorescence detector Fully automated analytical high performance liquid chromatography system with single point software control for all the modules of HPLC with the following specifications and the model quoted should be of latest configuration by the company Specification as per the Tender Notification Amended Specifications as per the in Chapter 4 Pre Bid meeting held on 22-02-2018 1. Solvent delivery system (Pump, Quaternary Gradient) in Chapter 4 The system should have Quaternary gradient pump and support minimum of four solvents. The system should work in isocratic and gradient modes. The system should have capability to perform low pressure quaternary gradient mixing ability. Vacuum degassing (5 channel): The built in online degasser with at least one channel per solvent and one channel for sample manager wash solvents should be quoted. The degassing has a provision to effective remove/reduce ghost peaks. Operating pressure should be 6000 psi or better suitable for both analytical and semi-preparative applications Flow rate should be 0.1 to 10 ml/min with at least 0.01 ml increments or better It should have leak sensors as standard and safe leak handling Flow accuracy should be ±1% or better Flow precision should be ±0.06% RSD or better Vacuum degassing (4 channel): The built in online degasser with at least one channel per solvent and one channel for sample manager wash solvents should be quoted. The degassing has a provision to effective remove/reduce ghost peaks. Operating pressure should be 5000 psi or better suitable for both analytical and semi-preparative applications

Should have pump seal wash function which will be equipped with wash system to flush the rear of the high pressure seal & the plunger Injection synchronization between pump and sample manager for retention time reproducibility System should work in the ph range of 2 to 12 or more Suitable solvent tray that can accommodate four solvents bottles of capacity and the solvent spill from this tray must not affect the instrument. The auto sampler vials/test tubes for fraction collection with variable volume capacity should be provided in addition to the vials/test tubes coming long with the instrument (500 Nos). Suitable Rheodyne manual injection valve with sensing switch and with loops of 5, 10, 20, 50 and 100 μl for analytical applications. Additionally these injections loops should be quoted of (Each 2 Nos) apart from the loops comes with the instrument. The manual syringes of 50 μl syringe (5 Nos) and 100 μl syringe (5 Nos) should be quoted separately in addition to the syringes comes along with the instrument. 2. Auto sampler/sample manager and column temperature compartment The auto sampler tray should have capacity to hold minimum of 200 Nos of 1.5 ml vials. Should quote as optional items Should quote as optional items The auto sampler tray should have capacity to hold minimum of 100 Nos of 1.5 ml vials or more

Injection volume range should be 0.1 to 1000 µl as standard loop or better with at least 0.1 µl increments Accuracy should be less than ±1% or better The injection precision should be less than ±0,25% or better Auto sampler with auto-dilution and auto-addition capabilities is preferable The automated pre/post column derivatization assembly/kit should be provided It should have capacity to hold two or more columns in column compartment The sample carryover should be less than 0.003% or better Design must ensure isolation of electrical components from liquid flow path Column temperature range should be programmable from ambient (25 o C) to 80 o C in 1 o C increments or more Safe leak handling must be provided with leak sensors There should be some option to track the column usage information Column temperature stability should be ±0.1 o C or better Column temperature accuracy should be ±0.5 o C or better Auto sampler vials (500 Nos each of 1.5 ml or equivalent) should be provided in addition to the vials comes along with the instrument Injection volume range should be 0.1 to 100 µl as standard loop or better with at least 0.1 µl increments

The columns C 18, C 8, HILIC or equivalent columns specific to pharmaceutical compounds, biomolecules such as carbohydrates, amino acids, fatty acids and chiral separations for analytical applications should be quoted separately (A total of 10 columns should be provided) Necessary guard columns with respect to above said columns should be quoted separately (A total of 12 Nos should be provided) Autosampler syringes (5 Nos each for analytical and semi-preparative injections) should be provided 3. PDA detector Wave length should be in the range of 190-800 nm or more settable in 1 nm increment The temperature controlled flow cells of detector for analytical applications (2 Nos) should be quoted in addition to the ones comes along with the instrument. The D 2 lamps (2 Nos) and W lamps (2 Nos) should be quoted separately in addition to the ones comes along with the instrument The columns C 18, C 8, HILIC or equivalent columns specific to pharmaceutical compounds, biomolecules such as carbohydrates, amino acids, fatty acids and chiral separations for analytical applications should be quoted separately (A total of 12 columns should be provided) C18 column 5µ particle 4.6 x 150mm: 3 number C8 column 5µ particle 4.6 x 150mm: 3 number Hilic column 5µ particle 4.6 x 150mm: 3 number Carbohydrate column: 1 number Aminoacid and fatty acid column: 1 number Chiral column: 1 number Suitable Guard column for above mentioned column Autosampler syringes (5 Nos each for analytical injections) should be provided The temperature controlled flow cells/suitable flow cell of detector for analytical applications (2 Nos) should be quoted in addition to the ones comes along with the instrument.

The detector must have linearity of 5% at 2.0 AU The detector must have wavelength accuracy of ±1 nm The detector must have guaranteed lamp life of not less than 2000 hours The detector should have lamp optimization software facility which guarantees low noise performance without lamp change and compensates for lamp degradation over time Data acquisition range should be 80 Hz or more The detector must able to operate in 3D and 2D simultaneously The detector should have low volume long path length flow cells for optimum performance and to achieve highest sensitivity. 4. Fluorescence detector Wavelength range should be 200 to 800 nm The low volume flow cell of 8 or 10 µl or less should be provided The band width should be 20 nm Wavelength accuracy should be ±2 nm Data acquisition range should be 70 Hz or more The suitable flow cells for analytical applications should be quoted (2 Nos) The detector should have leak sensor facility Sensitivity should be S/N>1000 (Raman spectrum of H 2 O) Wavelength repeatability should be ±0.25 nm

Two spare lamps should be provided separately Lamp life of 2000 hours or more should be guaranteed 5. Other specifications The chromatography software should be capable to control all modules such as pump, auto sampler, PDA and Fluorescence detector without any up gradation and have capability to robust peak integration, report formatting, qualitative and quantitative processing with effective detection of low level peaks on noisy or sloping baseline. The system should have software to automatically calculate the HPLC conditions from analytical to semipreparative and UHPLC applications. A latest suitable and compatible computer (i7/i5 processor, 1 TB HDD, 16GB RAM or more) with 26 TFT monitor and multifunctional laser printer with scanning and auto duplex printing facility for HPLC chromatographs and data (One set) Necessary tool kit for routine maintenance of quoted system Compatible UPS system with at least 10 KVA with built-in isolation transformer capable of taking inductive loads with at least 2 hours backup from Libert/APC with vertical batteries stand to support the whole system (One) Optional items: A stand-alone automated solid-phase extraction system of latest model with at least 6 samples per hour extraction efficiency will all accessories, including computer and software with 21 CFR part Computer and software can be omitted

11 compliance should be quoted separately as an optional item Important Note(s): The system should have GLP/GMP compliance and should strictly meet 21 CFR Part 11 guidelines. The system should enable for audit trails, electronic signature and other requirements related to GLP compliance. Further, required IQ and OQ reports should be generated to meet GLP regulatory requirements during installation and operation by your service personnel. All the necessary accessories, consumables, software etc should be quoted On-site training should be provided and off-site training at the vendors authorized training centre in India should be provided for two persons. All logistics and travel costs should be borne by the vendor. A good after sales service by the Indian agent/supplier/manufacturer should be guaranteed All the specifications mentioned above should be in the printed brochure of the company or on the company website and the technical specifications should be quoted with the manufacturer part number. Full system from the single vendor and no refurbished parts should be added to the system Cost of accessories and/or spares if required should be quotes item-wise separately Three years comprehensive warranty

should be provided. The warranty shall cover the maintenance of the instrument along with replacement of spares, accessories, consumables etc as and when required for the said warranty period. Two years AMC should be quoted for the whole instrument including software workstation, HPLC modules etc. Misc ellan eous Cost of accessories should be quoted item-wise separately 1. If the bidder is unable to show the proof for the technical compliance of specified points in the tender either in the brochure or technical data sheet or instruction manuals the specific point will be considered as does not complies the institutional specification. 2. Supplier should assure the shifting of the equipment to the new campus within the warranty period without any additional cost System should quote for ECD detector as optional item with specifications mentioned below Specifications for ECD detector Pulsed Electrochemical Detector: Operating Modes: Direct Current, Pulsed Amperometric Detection Scan. Potential Range : ±2000 mv in mv steps(dc, PAD Scan) Analog Signal output: ±1 Volt or ±10 Volt Selectable. Output Resolution: Analog 20 bit DAC, 24 bit RS232 digital communication to chromatography software personal workgroup or client computer. Analog signal offset : ±50% of analog signal output, in 10% steps.

Autozero : Maximum Autozero determined by analog signal potential range, triggered by keypad, event in signal or software control. Integrated flowcell & Column volume : 7ºC Above ambient to 45 ºC, 0.1 ºC Resolution. DC Range: Filter Time Constant : 0.1 to 5.0s in 1, 2, 5 sequence steps. Noise : <2pA, Drift : <8pA/hour. PAD Mode: Range : 10 na to 200 μa 1, 2, 5 sequence steps Scan Mode : Scan Range : 10 na to 200 μa 1, 2, 5 sequence steps Flow Cell: Design : Confined Wall Jet Standard Flow Cell : 0.080 μl minimum Volume, flow rates from 25.000 μl/min to 2000.00 μl/min Working Electrode Material : Glassy Carbon, Gold, Platinum, Silver. Sd/- Purchase officer

General Terms and Conditions applicable to all 13 tenders published in newspaper on 19 th February 2018 and exhibited in NIPER Guwahati website. Following additional information is provided for the information of prospective bidders for 13 different items for which tender inquiry is issued: 1. Payment terms: Considering the request made by few prospective bidders during the pre-bid conference held in the institute on 22 nd February 2018, regarding payment terms related with foreign suppliers it is clarified that the indicated payment terms in the tender documents still remains unchanged. However Director, NIPER Guwahati at his own discretion can consider any other mode of payment requested by suppliers based on the reputation, credentials of foreign suppliers in the field and also protecting the interests of NIPER Guwahati. No request for advance payment will be considered. 2. Clarification with regard to projecting the cost implications of free delivery of the item at NIPER Guwahati premises. Subsequent to the Pre-bid conference with regard to projection of price for items coming from abroad, the following guidelines may be followed: A) The F.O.B. C.I.F., C.I.P. prices as per the suppliers quote should be indicated in foreign currency only B) The additional cost towards payments of custom duty against duty exemption certificated provided by the institute, clearance charges, forwarding consignment from port of clearance to NIPER Guwahati premises etc. can be quoted in Indian currency. For comparing the price with other bids, the institute at the time of preparing comparative chart for the tenders, the total F.O.B., C.I.F., C.I.P. cost will be converted into equivalent Indian currency at the exchange rate prevailing on the date of tender opening i.e. 13 th February

2018 at 1500 hours IST and add the equivalent Indian currency value to the clearance and forwarding charges indicated by the supplier.