Magnescale Co., Ltd. Digital Readout General Catalog. Ihr Fachhandelspartner:

Similar documents
Digital Readout Systems

MAGNESCALE. digital magnetic scale. Series GB-ER. Key-Features:

GB-ER series. Direct connection to LH70/71 series

MAGNETIC TAPE. Series MB. incremental scale. Key-Features:

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

ENC - LKE51 - L I B

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

Three Axis Digital Readout System

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Ø50mm Shaft Multi-Turn Absolute Type

G5-series AC Servo Drives with Built-in EtherCAT Communications Linear Motor Type

Capacitive sensor BCT5-S18-UP6X2T-H1151

Quick-disconnect cables. Adjustable mounting brackets

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

RESOLUTE absolute optical encoder with Panasonic serial communications

Mechanical flow switch for On/Off control

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

Absolute Encoders Multiturn

DKS 40: Incremental Encoder

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Cylindrical Photoelectric Sensor CY-100 SERIES

OM2000N INSTALLATION MANUAL

LH1D Series Surface Mount Indicators

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

02/11/2015

Inductive sensor NI10-M18-Y1X-H1141

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Linear encoders without bearings incremental System for linear motion feedback

IMPAC Infrared Thermometers

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

LD OEM/LD PDS/LD PeCo

Inductive sensor NI3-EG08K-Y1-H1341

Technical data. General specifications. Indicators/operating means

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Scanning System S-2100

Product Information. LIC 4113 LIC 4193 Absolute Exposed Linear Encoders

ABS AT1100 Series. Assembly Type ABS AT Series Absolute Scale Unit (Standard Type) ABS AT Effective length Interface specifications

MAP110 AC-DC Series Data Sheet

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Documentation. Magnetic Encoder System (MES) Version: Date:

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

LM10 linear magnetic encoder system

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

Safety Light Curtains

Absolute Rotary Encoder E6CP

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Material: Weight: IP Rating: Cable: Connector:

USER S Manual NGLT104WPD NGLT150WPD LCD TV / Monitor (IP67 Grade)

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ

LED control gear Compact fixed output

Sensor technologies Proximity sensors Series ST4. Brochure

Engineered to meet your needs T he oldest name in stud welding,

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Panel-mounting thermostats, type series EM

STC-TC152USB-AT/AS/BTC/BSC STC-TB152USB-AT/AS/BTC/BSC Product Specification. Software Trigger USB 2.0 Color / Monochrome SXGA CCD Camera

Linear flow control with actuator IFC

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Safety Light Curtains GuardShield

Gurley Models LA18, LA20, LA25, High Resolution - Industrial Ruggedness

Magnetic Sensor - Incremental EHP

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

ABS ST700 Compact Type Series

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

Digital Readout Display

RKSlimlift / EM. Two-stage lifting column

Product Guide. Analog Panel Meters for use in Electrical Engineering Systems. M Series. Instruments clamping to 35 mm DIN rails W/P/ LSP BWQ BGQ

SMT Encoder for High Performance, High Volume Designs Small Size High Resolution Low Cost ChipEncoder Reflective Surface Mount Encoder Features

Quick-disconnect cables. Adjustable mounting brackets

LED-Strip C12 MK2.6. Product Sheet

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Transcription:

Digital Readout General Catalog Ihr Fachhandelspartner: GeBoTech GmbH Industriestaße 24 778 Bühl Tel. 7223/9249-3 Fax. 7223/9249-9 www.gebotech.de info(at)gebotech.de Magnescale Co., Ltd. Shinagawa Intercity Tower A-8F, 2--, Konan, Minato-ku, Tokyo 8-8, JAPAN Headquaters Tokyo Office Nagoya Office Osaka Office International Sales Department Magnescale Americas Inc. Magnescale Europe GmbH : 4 Suzukawa, Isehara-shi, Kanagawa 29-4, Japan TEL.+8()43-92- : 4 Suzukawa, Isehara-shi, Kanagawa 29-4, Japan TEL.+8()43-92-7972 : 2-3-, Meieki, Nakamura-ku, Nagoya Aichi, 4-2, JAPAN TEL.+8()2-87-823 : 2-4-, Nishi-Nakajima, Yodogawa-ku, Osaka 32-, JAPAN TEL.+8()-3-3 : 4 Suzukawa, Isehara-shi, Kanagawa 29-4, Japan TEL.+8()43-92-797 : 74 Warland Drive, Cypress, CA 93, USA TEL.+(949)77-84 : Antoniusstrasse 4, 73249 Wernau, Germany TEL.+49() 73 934 29 FAX.+8()43-92-2 FAX.+8()43-92-7978 FAX.+8()2-87-848 FAX.+8()-34-8 FAX.+8()43-92-7978 FAX.+(949)77-848 FAX.+49()73 934 24 http: // www.mgscale.com The contents of this literature are as of Mar. 2 This catalog is printed with soy ink. MGS-DR-4-EN-C Magnescale Co., Ltd.

Serial No. GB GB-ER SERIES (SR38R) The GB-ER series combines original Magnescale technology and legendary durability with a built-in reference point. System configuration Milling machine unit GB-ER series LH7/7 series Excellent durability against workshop conditions - resistant to oil, dirt, shock and vibration. Compact design for a space-saving installation. Accuracy: (+L/)μm :.μm Simple structure should be conducive to long life. Digiruler + head cable (option) Extension cable (option) Used by connecting to the cable part of the scale unit. CE-C (m) -3C (3m) -C (m) -C (m) Lathe unit GB-ER series LH7/7 series SR38R ( name of the scale itself)..2" 9./.37" (C) Measuring length mark =(A) Mounting hole pitch=(b) Measuring length=(l) Mounting hole pitch x /2 D x 7 Elongated hole 2/.79" * Center footplate mtg hole L=mm or more /.97" /2.3" 7/2.9" 8/3.3" 3/.42" Reference mark 2-ø, ø9 SF Slider center Slider holder /.2"./.4" (C) Alignment mark Serial No. 2-4. x. Elongated hole (Mounting hole) /.24"..2" 2/.98" 42/." 2/.83" 3./.44" 2 9.47".3" 2/.98" CH4 ( name of accessory cable) ø8/.7" 44/.72" (3m) (9/3.8") ø9/.3" Round waterproof connector (female) 3/.8" 3/.8" 3/.4" COMBINATION No.** ****** (8./3.4") 38/." 2.79" (7.7/.7") D-Sub 9-pin(male) Digiruler + head cable (option) table LZ7 (option) LZ8 (option) LZ9 (for lathe) (option) =.3m 44/.73" ø8/.7".9" Round waterproof connector(male) (3/.22") (7/.28") ø..22" GB series connection example Head/Cable Adapter (L) length (A) Max.travel With or without Centerfootplate Mounting hole pitch(b) (C) GB-ER ////2/3/3/4/4/////7/8/9//2/4//8/2/2 mm L + 4mm ( to mm) L + 2mm (2 to 2mm) L + 4mm ( to mm) L + 3mm (2 to 2mm) Without ( to 9mm) With ( to 2mm) L + 9mm( to mm) L + 7mm (2 to 2mm) 4.mm ( to mm) 3.mm (2 to 2mm) GB-ER SR38R SR38R CH4 CH4 CH4 CE3 SZ-AB LH7/7 LY7/72 LG2 LH/2/4-3 LY/2 LG Accuracy at 2 C Reference point Mounting parallelism (D) L + /2 ( to 2mm) mm (3 to 2mm) ( + L / ) μm Standard:Center point, User-selected point (AB quadrature) ±.mm GB-A SR28 CH SZ7- LH7/7 LY7/72 LG2 Expansion coefficient (±) x - / C to 4 C -2 to C SR28 CH LH/2/4-3 LY/2 LG Head cable length.3m 3m CH-LW LH3 Protective design grade Input/Output signal Output signal Connector :IP Interface unit:ip3 AB/ quadrature signal, Z signal DC + V ± % D-sub 9 pin. μm GB (SR8) SZ-MS LH/2/4-3 LY/2 LG LH3 Response speed signal Reference signal m/min m/min Max. ma 2 3

SJ SJ7A SERIES Cost-effective scale for Digital readout. SJ SJ3 SERIES legendary Magnescale technology has been improved! Magnetic based encoder Excellent resistance to workshop conditions Same coefficient of expansion as that of machine tools Measuring length: mm to mm /.9" to 2.9" Accuracy: ± μm, ± μm : μm SJ7A L:mm(inch) Maximum travel LH7/7, LH72 LY7, LY72, LG2 9. 37. Measuring length mark (A) 3. Slider holder 3 3 (3) =Measurng length+2 Mounting hole pitch=measuring length +7 Mounting hole pitch x /2 x 7 long hole *Center foot plate (Measuring length _(L) 2) Measuring length (L) 8 4 (8.) (9) (3) 2-M3 x 3 2 Alignment mark Slider center 2-ø hole, ø9 hole (Slider mounting hole) 2-M4 x 8 (Tap of mounting slider) (38) 2 (7) Serial No. SJ7A (.9"), 2 (9.8"), 3 (3.7"),4 (.7"), (9."), (2."),8 (3."), 9 (37.4"), (4.3"), 2 (49.2"),4 (."), (2.9") Measuring length + 2 (4.73") Measuring length + 2 (.78")( (.39") each at right and left). (7) (7.7) 3.. 2-ø4. x ø. (Mounting hole) Measuring length mark 4 2 (3.) 2 24 4 9 (27) 2 3 4 8 9 2 4 4. Measuring length (L) (A) 3 Flexible Reader Head mounting provides wider installation tolerances and less installation time. Excellent resistance to workshop conditions (IP4) Classic Magnescale benefits: No cleaning or maintenance, and no scratched or broken glass. No machined surface or backer bar required. Reader Head Status lamp provides visual signal status. mounting brackets slide and rotate to accommodate a wide range of installation configurations. Removable cable for easy replacement. (2./.8) SJ3 CH33 CPD/CED L:mm Accuracy(2 C) Max. response speed Output signal Min. output phase difference Expansion coefficient Status lamp functions Max. cable length voltage Vibration resistance Shock resistance Protective design grade Cable CH33 (7/.7) (3./.4) = 3///(m) connector LH7/7, LH72 LY7, LY72, LG2 /3.94 /3.94 Conduit (Ø.3/Ø.44) (Ø8/Ø.3) (4/.77) (/.9) D-sub 9P (33/.3) 38/. 4.3/ 2.3.2 SJ3 24/.94 48./.9 3./.4 8/.7 9 3/.3.2./.4 3/.42 = ML+8/.22 Mounting pitch = ML+8/3.39 3/.42 43/.9 Measuring length = ML 43/.9 (7/.28) SJ3- to SJ3-22 Maximum operating length = ML+8/.3(4each for left and right) 8/3. 9/3.4 (2./4.94) /2. (4.8/.9) (4.4/.) 2-M4 8/.3 (4.8/.9) Cable:CH33- CPD/CED(Sold separately) 2-M(ø./ø.9) (7/.28),,,,2,3,3,4,4,,,,,7,8, 8,9,,2,4,,8,2,2 L+8mm ±μm/m μm m/min AB quadrature (compliant with EIA-422) ns (7±)x - / C Low signal / Low power supply voltage m V±% 2.W or less(with load) to 4-2 to 2m/s 2,Hz to 2kHz m/s 2,mm/s IP(Or equivalent) 3./.4 8/.7 (MIN / MIN 2.3) 3/.2 22/.87 9 3/.3.2 M8 3./.3 ø./.9 28/. 27./.8 93/3. 34./.3 33./.32 8./.73 /.2 22/.87 7./.3./. ø./.9 /.43 /.9./.22 72./2.8 2/.83 8.3/.3. Accuracy (at 2 C/8 F) ± μm (Measuring length 2 (49.2") or less) ± μm (Measuring length 4 (.2") or more) Thermal expansion coefficient (2 ±) x - / C 3 m (9.8 ft) (SJ7A- to 8), m (.4 ft) (SJ7A-9 to ) 3CPD CPD CPD CPD CH33-3CED CED CED CED to + 4 C ( + 32 to + 4 F) L(m) 3 3-2 to + C (4 to + 4 F) Cable sheath PVC Polyurethane Operating humidity Condensation allowed Cable armor Yes Storage humidity 9 % Protective design grade IP( Side Connector) 4

SL SL/SL3 Non-contact detection and a long measuring range PL PL2C Head cable unit Magnetic principle Excellent resistance to workshop conditions (PL2C equivalent to IP). Resistant to oil, dirt, vibration, and shock. : μm Max. response speed: 3 m/ min (varies with the read head and settings). Available in lengths up to 3 m (SL3) High cost efficiency. Easy installation on all types of machines from wood working to metal cutting. SL3 Output signal: AB quadrature signal : μm Max. response speed: 3 m/min (varies with the read head and settings). Excellent resistance to workshop conditions (IP). Resistant to oil, dirt, vibration, and shock. SL/3 Head/Cable PL2C LH7/7, LH72 LY7, LY72, LG2 SL DIGIRULER SL/3 Head/Cable PL2C LH7/7, LH72 LY7, LY72, LG2 DIGIRULER SL SL3./.4 /.97 Measuring length (L) /.97 (.3)/(.) PL2C-**C(Metal armar added) SL/3 L mm (inch)./ 2.3 name SL-2 SL-3 SL-4 SL- SL- SL-7 SL-8 SL- SL-2 SL- SL- SL-7 SL-8 SL- Accuracy (at 2 C /8 F) Max. response speed Expansion coefficient Compatible read head 4./. x /.23 oval Clamp N x 3/.8 P (included) Measuring length (L)./2.3 : L + 3/ 4. 3 4 7 8 7 8 N 2 2 2 3 4 *Accuracy shows the value when used with PL2C read head. SL P -2 to - /3/4///7/8/// //7/8/ (7.8/.8/.7/9./23./27./3.4/39.3/47.2/ 9./2.9/.9/7.8/78.7) L+3 mm/ 4." (. ± ) x - / C 4/.77 3/.38 24.4/.9 9/.3./.4 Number of Clamps 4 4 8 8 2 4 4 4 ± (2 + L/ ) μm (4/.) (4/.) SL3-2 to -7-8 to -3 /3/4///7/8/// //7/8//2/3/ 4///7 (7.8/.8/.7/9./23./27./3.4/39.3/ 47.2/9./2.9/.9/7.8/78.7/98.4/8./ 7.4/9.8/23.2/27.) μm 3 m/ min name SL3-2 SL3-3 SL3-4 SL3- SL3- SL3-7 SL3-8 SL3- SL3-2 SL3- SL3- SL3-7 SL3-8 SL3- SL3-2 SL3-3 SL3-4 SL3- SL3- SL3-7 SL3-8 - C to 4 C / 23 F to 3 F - C to C / 4 F to 22 F PL2C 3 4 7 8 7 8 2 3 4 7 8 L+ mm/ 3.9" (.4 ± ) x - / C Movable length 23 33 43 3 3 73 83 3 23 3 3 73 83 23 23 33 43 3 3 73 83 3 4 7 8 9 3 7 8 9 2 2 3 4 7 8 9/.3 8/9///3 (34.9/34.3/393.7/787.4/8.) /.39 ± (2 + L/ + N) μm N=when L=8 /9/, N=2 when L=, N=3 when L=3 7 PL2C-** Output signal Max. response speed Head mtg. screw tightening torque 2 2 2.4 2.4 7 7 29. 28 PL2C-3/-3C 3 m 2 x7. Mouting hole 3 3 3 2 3 9 8.2 4.9 4 2 x7. Mouting hole 28 3 3 29. 9 (4) 8.2.9 4 PL2C-/-C m 9 3 2 4 7. 3 (3) 8. 9 PL2C-/-C PL2C-/-C m m AB quadrature signal um 3m/min.7~.N. m to 4 C/32 to 3 C - to C/-4 to 22 F (8.) (9) (3) (7) (38) Depth 2 (3) (7) 2 M3 Depth3 2 (38) PL2C-2/-2C 2 m 7 7.7 (7) (7.7) PL2C-3 3 m Unit : mm

LH LH7/7 SERIES High performance counter for Mille and Lathe applications. LH LH72 High performance Lathe specific counter. for Milling machine (LH7/7) and Lathe (LH7-3/LH7-3) Switching Machine error compensation Data Storage. Reset/Preset Detecting Reference Point of Measurement Unit Program function Multi datum point Scaling Milling function (Bolt hole circle / Easy R cutting / Line hole) Lathe function (Tool coordinating / Adding function) for Lathe (LH72-3) Switching Machine error compensation Data Storage. Reset/Preset Detecting Reference Point of Measurement Unit Program function Scaling Lathe function (Tool coordinating / Adding function) Common LH7/7- LH7/7-2 LH7/7-3 Connectable measuring unit Measuring unit input resolution resolution Input signal Minimum input phase difference Quantization error Alarm display Reset Preset Reference point detection Data storage Linear error compensation Segmented error compensation Scaling Program Angle display Sleep range range Mass Multi datum point Bolt hole circle Simple R cutting Line hole 7 digits and minus display, Color amber GB-ER, SJ3 series, SJ7A, PL2C series (Direct) DG-B (Necessary to use the conversion adaptor which is sold separately.) Standard:. μm,. μm, μm, μm, μm, s, s, min, min Expanded: μm, μm, 2 μm, 2 μm, 2 μm,. μm and degree can be added. Measuring unit input resolution or higher and diameter display (except for angle display) A/B quadrature signal, Z signal (Conforms to EIA-422.) ns ± count Measuring unit disconnected, Excess speed, Maximum display amount exceeded, Power failure, Error in stored data Resettable by key switch It is possible to store/call 3 kinds of numbers. The reference point of the measuring unit can be detected, and the datum point can be relocated (during connection of measuring unit with a reference point) The value displayed before the power was turned off and setting values are stored A fixed compensation is applied to the measuring unit's count value. Compensation amount Standard: ± um/m (Expanded: ± um/m) The movement range of the measuring unit with a reference point can be divided into amaximum of 32 sections, and error compensation is performed for each of these sections. Compensation amount: ± um (at each section)(lh7 only) Scaling factor:. to 9.999999(LH7 only) Machining coordinates can be programmed (number of program steps: 8 max.). Manual programming by key switch 2. Automatic programming by playback 3. Mirror image during program execution 4. A canned cycle (bolt hole, line hole, simple R cutting) can be inserted in the program. (LH7 only) Can be displayed as an angle value when the Digiruler is pasted to the arc surface, and the diameter and Digiruler resolution are entered The display is turned off when no operations are made for a preset time. (The time can be set.) DC 2 V Rating.7 A Max. A AC V to 24 V ± % When using the AC adaptor PSC-22 (For U.S. only) or PSC-23 (For Europe and other countries) *Option MAX. 32 VA connected at the AC adaptor. to 4 C (no condensation) -2 to C (no condensation) Approx.. kg When the LH7/7 general-purpose applications or milling machine function are selected (General setting in the model type selection mode of the basic settings) LH7- -axis LH7- LH7-2 2-axis LH7-2 LH7-3 s coordinates for opening equidistant holes along the perimeter of a designated diameter coordinates for simple R cutting s coordinates for opening equidistant holes along a designated straight line(lh7 only) 3-axis LH7-3 Common Connectable measuring unit Measuring unit input resolution resolution Input signal Minimum input phase difference Quantization error Alarm display Reset Preset Reference point detection Data storage Linear error compensation Segmented error compensation Scaling Program Angle display Sleep axes Tool offset Measuring unit input addition hold range range Mass LH72-3 7 digits and minus display, Color amber GB-ER, SJ3 series, SJ7A, PL2C series (Direct) DG-B (Necessary to use the conversion adaptor which is sold separately.) Standard:. μm,. μm, μm, μm, μm, s, s, min, min Expanded: μm, μm, 2 μm, 2 μm, 2 μm,. μm and degree can be added. Measuring unit input resolution or higher and diameter display (except for angle display) A/B quadrature signal, Z signal (Conforms to EIA-422.) ns ± count Measuring unit disconnected, Excess speed, Maximum display amount exceeded, Power failure, Error in stored data Resettable by key switch or remote reset. It is possible to store/recall 3 kinds of numbers. The reference point of the measuring unit can be detected, and the datum point can be relocated (during connection of measuring unit with a reference point) The value displayed before the power was turned off and setting values are stored A fixed compensation is applied to the measuring unit's count value. Compensation amount Standard: ± um/m (Expanded: ± um/m) The movement range of the measuring unit with a reference point can be divided into amaximum of 32 sections, and error compensation is performed for each of these sections. Compensation amount: ± um (at each section) Scaling factor:. to 9.999999 Machining coordinates can be programmed (number of program steps: 8 max.). Manual programming by key switch 2. Automatic programming by playback 3. Mirror image during program execution Can be displayed as an angle value when the Digiruler is pasted to the arc surface, and the diameter and Digiruler resolution are entered The display is turned off when no operations are made for a preset time. (The time can be set.) 2-axis display (2-axis or 3-axis input) 99 2-axis addition display is available The displayed value can be held and the tool coordinate entered. DC 2 V Rating.7 A Max. A AC V to 24 V ± % When using the AC adaptor PSC-22 (For U.S. only) or PSC-23 (For Europe and other countries) *Option MAX. 32 VA connected at the AC adaptor. to 4 C (no condensation) -2 to C (no condensation) Approx.. kg When the LH7/7 lathe function is selected (Lathe setting in the model type selection mode of the basic settings) LH7-3 axes 2-axis display (2-axis or 3-axis input) Tool offset 2 Measuring unit input addition hold 2-axis addition display is available The displayed value can be held and the tool coordinate entered. LH7-3 99 LH7/7, LH72 24 *Please refer to P.2 panel cut-out diagram. 4 8 (.) (9.) 28. 3 3 8. 22 3. 7. 88. 98. 23. 3. 23 3. 4 M Max depth7 7 289 2 M4 Max depth8 23 (23.7).7 44 8 Unit : mm AC adapter The AC adapter for LH7/7, LH72 and LG2 counter unit. PSC-2 (For Japan only) PSC-22 (For U.S. only) PSC-23 (For Europe and other country.) AC adaptor (option) 8 9

LG Selectable display resolution input signal : A/B quadrature signal Machine Error Compensation Data Storage Preset / Recall Flicker Control LG2 SERIES of standard function. Safety No compromise for high-accuracy products The total quality control system that operates throughout the entire design and production process ensures products with enhanced safety, high quality, and high reliability that match our customers requirements. The company is certified for length calibration in compliance with the traceability system required by the Weights and Measures Act, and has been granted ISO 9 certification, which is the international standard for quality assurance. 24 4 8 (.) (9.) 7 2-M4 289 Max depth8 23 23.7.7 44 8 Our products comply with CE Marking requirements, have acquired UL certifications and meet other regulations, ensuring safe use the world over. We have met: EMC Directives(CE) FCC regulation EMI: EN Group Class A / 9 FCC Part Subpart B Class A EMS: EN --2 for Products with built-in AC power supply: for Products with Laser: UL - DHHS Class (2CFR4.) * When using our devices with machines to which the European Machinery Drirective applies, please make sure that the devices when installed on the machines fulfil the applicable requirements of the Directive. * Standards or regulations to be complied with may vary by product. 4 R3 or less axes Connectable measuring unit Measuring unit input resolution resolution Input signal Minimum input phase difference Quantization error Alarm display Preset Data storage Linear error compensation Sleep range range Mass 22 24. Panel cut-out diagram 23.3 4 ø. 3.3 (3) LG2- -axis 28. 3 3 8. LG2-2 2-axis 22 3. 7. 88. 98. 23. 4-M Max depth7 LG2-3 3-axis 7 digits and minus display, Color amber GB-ER, SJ3, SJ7A, PL2C Series (Direct), unit DG-B (Requires a conversion adaptor which is sold separately.). μm,. μm, μm, 2 μm, μm, μm, 2 μm, 2 μm, μm, μm Measuring unit input resolution or higher and diameter display A/B quadrature signal (Conforms to EIA-422.) ns ± count Measuring unit disconnected, Excess speed, Maximum display amount exceeded, Power failure, Error in stored data It is possible to store/recall 3 kinds of numbers. The value displayed before the power was turned off and setting values are stored A fixed compensation is applied to the measuring unit's count value. Compensation amount: ± μm/m) The display is turned off when no operations are made for a preset time. (The time can be set.) DC 2 V Rating.7 A Max. A AC V to 24 V ± % When sssusing the AC adaptor PSC-22 (For U.S. only) or PSC-23 (For Europe and other countries) *Option MAX. 32 VA connected at the AC adaptor. to 4 C (no condensation) -2 to C (no condensation) Approx.. kg 3. 23 3. Unit : mm Traceability Traceability Flow Chart (Length) National Primary Standards National Secondary Standards Practical Standards National Institute of Advanced Industrial Science and Technology (AIST) Iodine saturation absorption stabilized He- Ne laser at 33nm Speed of light (laser) C=29979248m/s National standards Iodine saturation absorption stabilized He-Ne laser at 33nm Stabilized He-Ne Laser (33nm) Magnescale Corporation International Committee for Weights and Measures (CIPM) International Bureau of Weights and Measures (BIPM) Calibration product (Customer, s equipment)