HCS - HES Cabling Systems

Similar documents
3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

INSTALLATION INSTRUCTIONS

Medium Box for Cable Termination

3M Distribution Box (DDB)

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

IP-LINX Fiber :: X-XXXX

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

FOSC 450 C6 and D6 Closures

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

IP-LINX. Installation Guide

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

Optical Distribution Box 300 Installation Guide. Version : R0.0

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

3M Fiber Optic Wall Mount Enclosure 8430 Series

3M Fiber Optic Splice Closure 2178-L/S Series with Gasket

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

2178-L/S Series Fiber Optic Splice Case with Gasket

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

SLiC Fiber Aerial Closure System

18mm ECAM Cable Entry Port

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

INSTALLATION INSTRUCTIONS

27mm ECAM Double Cable Entry Port

2178 L/S Series Fiber Optic Splice Cases and Accessories

Fiber Cable Preparation, Splicing, and Termination Instructions (CFDP210-EL24 Charlesr Fiber CFDP2 Pedlockr OSP Pedestal)

CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories

LGX Compatible (LSX) Connector Module) User Manual)

Gel-sealed in-line fiber optic closure

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

LANmark-OF ENSPACE Patch Panel

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

LANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU. empty. Clip-on. with Sliding mechanism. Black or white INSTALLATION GUIDE

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

Next Generation Frame (NGF) Fiber Combination Block (FCB) User Manual)

RACKS, ENCLOSURES AND CABLE MANAGEMENT

Public Works Division Lighting District Fiber Optic Specifications April 2009

Section Communications Optical Fiber Backbone Cabling

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

Fiber Optic Splice Closure GPJ Instruction Manual. [Escribir texto]

Crimp & Cleave Termination Instructions for SEL ST Connectors

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

Ordering Guide. for FIST-GSS2 product range

AUDIO ROOF KIT P/N , , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

Modular Six pack Patch Panel. for 24 Snap-in Connectors. Clip-on and Shutters. with Sliding mechanism INSTALLATION GUIDE

Cable and Power Management Open-Frame Rack Cable Managers

3M Coupling Tray FDTC-10S-COUPLINGTRAY

Fiber Optic Splice Closure GPJ Instruction Manual

Panduit Recommended Best Case Practice Split Fibre

NGF optical distribution frame

Clearview. Classic Cassettes. Installation Manual. Clearview Classic (HD) High Density. Part #: Rev: A Updated:

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

3M Better Buried Compound Compression Closure System

3 SLiC Aerial Closure with Rubber End Seal

Customer-Owned Outside Plant

GENUINE PARTS. SIRIUS Under Glass Antenna Kit

FOSC 400 A4 Fiber Optic Splice Closure

The FiberMark1 offers an ideal solution for

SCdefault. 900 Installation instructions. Accessories Part No. Group Date Instruction Part No. Replaces :36-29 Sep

TITLE: FIBER OPTIC SHOCK FIXTURES

SPECIAL SPECIFICATION 6559 Telecommunication Cable

FOSC-450 Product Range Ordering Guide

SPECIAL SPECIFICATION 8540 Telecommunication Cable

FOSC 400 B2/B4. Fiber Optic Splice Closures. Table of Contents. Page 1

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

Aerospace Fiber Optics

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

GENUINE PARTS CAUTION

Seal Kits for BUDI Enclosures

Fiber ICT. Optical Fiber Catalogue

Water blocking tape. Locator ridge HPA-0486

GENUINE PARTS SATELLITE RADIO INSTALLATION INSTRUCTIONS. 1. DESCRIPTION: Satellite Radio System 2. APPLICATION: Frontier (2006~)

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

INSTALLATION INSTRUCTIONS

Michigan State University Construction Standards EXTERIOR FIBER OPTIC CABLE SYSTEM PAGE

Installation instructions, accessories. Subwoofer. Volvo Car Corporation Gothenburg, Sweden. Page 1 / 29

INSTALLATION INSTRUCTIONS MO023A

SECTION COMMUNICATIONS HORIZONTAL CABLING

3A TC 699/SIP/UK/12

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

RetractaNet XS. Extractable Solutions for OSP. October 2012

DLMP Installation Instructions

Caution. Hanging the Screen:

Cable ISOBUS Active Termination

Transcription:

HCS - HES Cabling Systems Installation Manual for HCS High-Capacity Fiber-Optic Rack-Mount Cabinets Be sure to read and completely understand this procedure before applying product. Be sure to select the proper HCS product before application. This manual provides installation manual for the following items: HCS P/N Product Description PFO-07P01-2U High capacity FO Rack Mount 19 Panel 36/48/72 Fibers PFO-07P02-2U High capacity FO Rack Mount 23 Panel 36/48/72 Fibers PFO-07P03-2U High capacity FO Rack Mount 19 Panel 72/94/144 Fibers PFO-07P04-2U High capacity FO Rack Mount 23 Panel 72/94/144 Fibers PFO-07P05-3U High capacity FO Rack Mount 19 Panel 144/192/288 Fibers PFO-07P06-3U High capacity FO Rack Mount 23 Panel 144/192/288 Fibers CONTENTS PAGE 1. NOMENCLATURE...1 2. DESCRIPTION...2 3. MOUNTING ON RACK...2 4. FIELD TERMINATION APPLICATIONS...2 5. PIGTIAL/SPLICING APPLICATIONS...3 6. PREPARATION AND ROUTING OF FEEDER CABLE...3, 4 CONTENTS PAGE 7. PIGTAIL PREPARATION AND ROUTING...4, 5 8. FIBER SPLICING AND SPLICE TRAY...5, 6 9. JUMPER ROUTING...7 10. ACCESSORIES...6, 7 11. SAFETY CONSIDERATIONS...7 1.00 NOMENCLATURE 1. Rack Mount Cabinet Assembly 2. Small Parts Bag (mounting screws, tie wraps, splice holder) 3. Mounting Brackets (2) 4. 5. Universal Coupler Plate (sold separately) Transition Assembly 6. Splice Tray(s) 7. Splice Tray Hold Down Strap 8. Transport Tubes 9. Pigtail Tube Assemblies 10. Studs and Nuts 3. 2. 5. 6. 4. 1. 9. 7. 8. FIGURE 1A - CABINET Page 1 of 6

2.00 DESCRIPTION 2.01 HCS FO Rack Mount Cabinets are designed to protect and organize optical fiber splices and connectors in a standard equipment rack in the central office, equipment room, and CEV. 2.02 3 sizes of cabinets are available to accommodate from 36 to 288 fiber splices and connectors. 2.03 The Splicing Kits which are purchased separately, provide the Splice Trays and associated components required to splice pigtails (sold separately) to the fibers of the feeder cable. Each Splice Tray accommodates 24 splices. 2.04 The Mounting Brackets allow mounting the cabinets to either 19 or 23 equipment racks. 2.05 Universal Coupler Plates are available with all standard fiber optic connectors (6 connectors per plate) and are ordered separately. (See Section 10.00) 3.00 MOUNTING ON RACK 3.01 Attach the appropriate Mounting Bracket to each side of the cabinet using the screws provided. Shorter brackets are included for mounting to a 19 equipment rack. The longer brackets are used for mounting to a 23 equipment rack. 3.02 Mount the cabinet to the equipment rack at the desired height with the screws provided. 4.00 FIELD TERMINATION APPLICATIONS 4.01 Remove the following minimum length of jacket from the cable: 07P01 & 02: 1.8m 07P03 & 04: 2.0m 07P05 & 06: 2.3m 4.02 Remove the rear cover from the cabinet by turning the 1/4 turn fasteners counterclockwise. 4.03 Slit the grommet in the cable entry at the rear of the cabinet on the side being used for cable entry, and position the cable into the entry. 4.04 Install the L-Bracket Assembly adjacent to the entry being used with the 1/4 bolt, nut, and lock washer provided. 4.05 If required, install a bond connector at the end of the cable bracket and secure it to the L-Bracket Assembly. 4.06 Capture the central strength member or any other strength member into the clip on the L-Bracket Assembly. 4.07 Install the Universal Coupler Plates (purchased separately) in the cabinet bulkhead. Push the locking fasteners at the ends of the Coupler Plates to secure them in place. 4.08 Route the individual jacketed fiber elements around the Fiber Radius Hoops 1 ½ times, for a cable entering the left side of the cabinet, and 1 time for a cable entering the right side, then to the Coupler Plates. Note: Be sure to maintain a 45 to 50mm bending radius on the individual fiber elements as they go around the top or bottom Radius Hoops and to the Coupler Plates. 4.09 Mark the jacketed fiber elements at a point about 25mm beyond where they contact the bulkhead (this provides additional fiber length for application of the connectors). 4.10 Field install the connectors to the jacketed fiber elements according to your accepted company practices, and the recommendations from the connector supplier. 4.11 Install the connectorized fiber elements to the bushings on the Universal Coupler Plates. 5.00 PIGTAIL/SPLICING APPLICATIONS 5.01 Sections 6.00 through 8.00 detail the steps required where pigtails are used, and spliced into the feeder cable fibers within the cabinet. 5.02 Loosen the nuts, and remove the Fiber Radius Hoops from the inside of the cabinet. 5.03 Screw the 1/4 studs provided with the Splicing Kit into the PEM nuts on the bottom of the cabinet. 5.04 Install the Transition Assembly provided with the Splicing Kit over the 1/4 studs, and secure in place with the 1/4 nuts provided. Page 2 of 6

6.00 PREPARATION AND ROUTING OF FEEDER CABLE 6.01 Remove a minimum of 2.3m of sheath from the cable, and clean cable according to accepted company practices. 6.02 Remove the rear cover from the cabinet by turning the 1/4-turn fasteners counterclockwise. 6.03 Slit the grommet in the cable entry at the rear of the cabinet on the side being used for cable entry, and position the cable into the entry. 6.04 Lay the buffer tubes or single-tube into the Transition Assembly. For single-tube application, skip to Step 6.10. Note: The retaining tabs on top of the Transition Assembly are removable to facilitate placement of buffer tubes. Transition Assembly and then around to the back wall). 6.06 Starting with one of the buffer tubes, remove the buffer tube up to the mark, and clean the fibers per your accepted company practices. 6.07 Feed the fibers from this buffer tube into one of the Transport Tubes provided with the cabinet. Insert the end of the buffer tube 12mm into the Transport Tube. 6.08 Repeat Steps 6.06 and 6.07 for the remaining buffer tubes. 6.09 Using two of the tie wraps supplied with the Splice Tray(s), secure the buffer tubes and Transport Tubes to the back wall of the Transition Assembly. (Figure 3) Proceed to Step 6.15. 6.05 Mark the buffer tubes at the back wall center-line of the Transition Assembly as shown in Figure 2. (Note that for cable entry into the right side of the cabinet, the buffer tubes are routed against the front of the FIGURE 3- SECURE BUFFER TUBES & TRANS- PORT TUBES TO TRANSITION ASSEMBLY 6.10 Mark the single-tube at a point 50mm from where it enters the Transition Assembly (for either right or left side cable entry). FIGURE 2A- MARK BUFFER TUBES FOR RIGHT SIDE CABLE ENTRY 6.11 Remove the single-tube and clean the fibers per you accepted company practices. Make sure to maintain the identity of each bundle of twelve fibers. 6.12 Secure the single-tube to the Transition Assembly with the tie wraps provided. Use two sets of the tie down holes in the side of the Transition Assembly. FIGURE 2A- MARK BUFFER TUBES FOR LEFT SIDE CABLE ENTRY 6.13 Feed each bundle of fibers into one of the Transport Tubes provided with the cabinet so that the end of the Transport Tubes will be located just beyond the center-line of the back wall of the Transition Assembly. (Figure 4) Page 3 of 6

7.03 Select six pigtails, clean the fiber connector, and connect them to the rear side of the Coupler Plate. 7.04 Route the pigtails along the Transition Assembly toward the right side of the cabinet, while maintaining a smooth bending radius behind the Coupler Plates. (Figure 5) FIGURE 4A - FIBER ROUTING & TRANSPORT TUBE LOCATION FOR RIGHT SIDE CABLE ENTRY 7.05 Mark the jacket of each of the pigtails at a point 50mm beyond the bending radius as shown in Figure 6. 7.06 Carefully remove the jacket on each pigtail FIGURE 4B - FIBER ROUTING AND TRANSPORT TUBE LOCATION FOR LEFT SIDE CABLE ENTRY 6.14 Secure the Transport Tubes to the back wall of the Transition Assembly with two of the tie wraps provided. Be sure that the fibers are not bent as they enter the Transport Tubes. If necessary, use some of the felt tape provided to secure the fibers to the Transition Assembly. FIGURE 5 - ROUTE THE PIGTAILS up to the mark. Number or color code the connector strain relief and the 900 micron tight buffer for fiber identification. 6.15 Carefully coil the Transport Tubes and bare fibers into the base of the Transition Assembly until a later step in this procedure. 7.00 PIGTAIL PREPARATION & ROUTING 7.01 The required pigtail length for all types of Rack Mount Cabinet is 3m. 7.02 Select one of the Universal Coupler Plates (purchased separately) and install it in one of the locations in the cabinet bulkhead. Push the locking fasteners at the ends of the Coupler Plate to secure it in place. FIGURE 6 - MARK PIGTAILS Note: HCS has pigtails available with different colored 900 micron tight buffer coating to simplify fiber identification. Page 4 of 6

7.07 Feed the group of six buffered fibers into the end of one the Pigtail Tube Assemblies with the larger diameter tube section, until the pigtail jackets are within the larger tube about 10 to 12mm. (Figure 7) Note: Moisten the ends of the pigtail jackets to ease insertion into the tube. 7.08 Repeat Steps 7.05 through 7.07 for each group of pigtails. 8.00 FIBER SPLICING AND ROUTING 8.03 Place a Splice Tray on the threaded studs over the Transition Assembly. Note: Install the tie wraps into the Splice Tray tie down holes prior to installing the Splice Tray. (Figure 9) 8.04 Select four Pigtail Assembly Tubes within the wide entry slot of the Splice Trays and the Transport Tubes and two Transport Tubes for installation onto the Splice Tray. 8.05 Lay the Pigtail Assembly Tubes within the FIGURE 7 - INSERT PIGTAILS INTO PIGTAIL TUBE ASSEMBLY 8.01 Route the Transport Tubes with the feeder cable fibers and the Pigtail Tube Assemblies within the Transition Assembly so that they will exit at the front left corner of the Transition Assembly. (Figure 8). 8.02 Use two tie wraps to gently secure the Pigtail Assemblies to the back right side fo the Transition Assembly as shown in Figure 8. FIGURE 9 - INSTALL TIE WRAPS INTO SPLICE TRAY wide entry slot of the Splice Trays and the Transport Tubes within the first two narrow slots, and mark the tubes slightly beyond the tie down locations. (Figure 10) 8.06 Carefully cut the tubes at the marks, and remove the excess length. 8.07 Secure the Pigtail Tubes and Transport Tubes to the Splice Tray with the tie wraps. (Figure 11) FIGURE 8 - ROUTE TRANSPORT AND PIGTAIL TUBES WITHIN TRANSITION ASSEMBLY FIGURE 10 - MARK TUBES IN SPLICE TRAY 8.08 Route the Pigtail and Feeder Cable fibers one complete turn around the Splice Page 5 of 6

Tray and into the splice groove furthest from the entry point of the tubes. (Figure 12) FIGURE 13 - SECURE SPLICE TRAYS WITH SPLICE TRAY HOLD DOWN STRAP FIGURE 11 - SECURE TUBES TO SPLICE TRAY Note: Temporarily remove the retaining tabs from the Splice Tray to ease fiber placement. 8.09 Splice Feeder Cable fibers to Pigtail fibers per accepted company practices. Place each splice in a groove, starting from the furthest groove from the tube entry. 9.02 Gently bend the jumpers toward and through the grommet on either side of the cabinet. 9.03 Lightly secure the jumpers to the tie down post with the tie wraps provided. 9.04 Lightly secure the jumpers to the equipment rack with the tie wraps. 10.00 ACCESSORIES 10.01 All Coupler Plates and Pigtail Assemblies can be found in HCS available for the FIBER OPTICX Rack Mount Cabinets. 11.00 SAFETY CONSIDERATIONS 11.01 This application procedure is not intended to supersede any company construction or safety standards. This procedure is offered only to illustrate safe application for the individual. Failure to follow these procedures may result in personal injury. FIGURE 12 - ROUTE FIBERS WITHIN SPLICE TRAY 8.10 Repeat Steps 8.03 through 8.09 for additional Splice Trays. 8.11 Secure Splice Trays in place with Splice Tray Hold Down Strap. (Figure 13) 9.00 JUMPER ROUTING 11.02 When working in the area of energized lines, extra care should be taken to prevent accidental electrical contact. 11.03 For proper performance and personal safety, be sure to select the proper size HCS Product before application. 11.04 This product is intended for use by trained technicians only. The product should not be used by anyone who is not familiar with, and not trained to use it. 9.01 Clean the fiber connectors and attach the jumpers to the front side of the Coupler Plates. Page 6 of 6