10MHz Source/Inserter

Similar documents
MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model Downconverter

Instruction Manual Model BlockUpconverter

Instruction Manual Model # Block Upconverter

Instruction Manual Model Up/Downconverter

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model UHF, L-Band, Up/Downconverter

Instruction Manual Model Block Downconverter

Instruction Manual Model Block Upconverter

Model /29S RF Splitter

L-BAND MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model Upconverter

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model Translator

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

INSTRUCTION MANUAL. MODEL Downconverter

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model 2412-x08 Multi-Channel AGC Amplifier

Model P/03P Upconverters

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model Block Up/Downconverter

Instruction Manual Model

Instruction Manual Model

Instruction Manual Model Upconverter

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

Instruction Manual Model Ka-Band Block Downconverter

X-Band Redundant LNB Systems

C-Band Redundant LNB Systems

Ku-Band Redundant LNB Systems

Modular Block Converter Systems

DTV742 Installation Quick Start Guide

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

DTV744 Installation Quick Start Guide

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Noise Detector ND-1 Operating Manual

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

L-Band Block Upconverter

RCU101. 1:1 Converter Protection Switch Installation and Operation Manual. Part Number TM055 Revision 2.2. May, 2002

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

Inmarsat Downconverter Narrowband Downconverter

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

MULTIBAND 1/3 RACK-MOUNTED

Multiple Band Outdoor Block Up- and Downconverters

SYNTHESIZED COMMUNICATION CONVERTERS

ipump 622 Streaming Media Decoder Installation Quick Start Guide

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

Synthesized Block Up- and Downconverter Indoor / Outdoor

1/3 RACK-MOUNTED BLOCK CONVERTERS

Satellite Up- and Downconverter

L-Band Block Up- and Downconverter Indoor / Outdoor

High Performance Outdoor Test Translators

Synthesized Block Up- and Downconverter

SCR Series Synthesized Converters L, C, X, Ku, and DBS Bands

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

High-Value 100 Series (Outdoor)

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

MODEL Band Channels Up/Down IF In/Out RF In/Out Step Size Remote M&C Price

ST60-DVC VTR CONTROLLER ST60-AG57 VTR CONTROLLER

NS-3 RF Noise Source Operation Manual

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Satellite Up- and Downconverter Indoor / Outdoor

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS

Model R177M and R177S Baseband Switch

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

DESCRIPTION APPLICATIONS AGILE IF TO L-BAND/RF AZIMUTH SERIES UP/DOWN FREQ CONVERTER NTC/2142

Model No. ST100 VTR CONTROLLER

AVMU2-BHD+/3G Audio monitoring Unit

4X1 Gefen TV Switcher GTV-HDMI N. User Manual

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

AMU1-BHD+ Audio monitoring Unit

AMU2-2MHD+ Audio monitoring Unit

ACION 8000 Series. A8KFR1 1RU Forward Receiver

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

Satellite Up- and Downconverter

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

(Non-Radioactive Surge Arrester) OPERATION MANUAL RS232 TO RS485/RS422 BOX CHAPTERS APPENDICES. A. Warranty Information.. 11

SDC-500 Digital Optical Chopper Operating Instructions

clipping; yellow LED lights when limiting action occurs. Input Section Features

USER GUIDE. DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version DM Engineering

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

CardModule. Reference Manual. Series C DA Channel SDI to CVBS Converter. Version 1.0

DA E: Series of Narrowband or Wideband Distribution Amplifiers

For warranty service, please contact Microframe at: A technician will gladly assist you.

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

Model 5240 Digital to Analog Key Converter Data Pack

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

ModuMAX SSPA Systems. C, X, and Ku Bands. Completely modular solid-state power amplifier systems for world-wide satellite communications

Indoor Dual Converter

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Transcription:

Instruction Manual Model 2099-218 10MHz Source/Inserter Redundant 18V January 2011, Rev. A RX 0.32 A TX 0.86 A REF ON REF OFF MENU MODEL 2099 SOURCE/INSERTER CROSS TECHNOLOGIES INC. PS1 PS2 REMOTE ALARM OVEN EXT REF EXECUTE Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com

INSTRUCTION MANUAL MODEL 2099-218 10MHz Source/Inserter TABLE OF CONTENTS PAGE Warranty 2 1.0 General 3 1.1 Equipment Description 3 1.2 Technical Characteristics 4 1.3 Environmental Use Information 5 1.4 Monitors & Controls 6 2.0 Installation 9 2.1 Mechanical b 2.2 Rear Panel Outputs 10 2.3 Front Panel Indicators 11 2.4 Operation 12 2.5 Menu Settings 13 WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc. s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc. s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com 2099-218 Manual, Rev A. Page 2 01/19/11

MODEL 2099-218 10MHz Source/Inserter 1.0 General 1.1 Equipment Description The 2099-218 10 MHz Source/Inserter is a 10 MHz, ± 0.01 ppm oven controlled crystal oscillator (OCXO) with circuitry to insert the 10 MHz signal and DC voltage on L-band lines for an LNB and SSPB. Multi-function push button switches select Internal, Auto (Auto switches to internal when external source < -2 dbm), or External 10MHz and insertion of 10 MHz on the L-band lines. LEDs indicate DC power (green), alarm (red), remote operation (yellow), and OCXO oven warm-up (yellow). Remote control allows remote configuration of front panel commands and monitoring LNB and SSPB current. Parameter selection and LNB and SSPB current appear on the LCD display. Connectors are BNC female for RF and 10 MHz external input and output signals. LNB or SSPB +18 VDC can be inserted on the RF lines by installing the fuses. Redundant AC power is 100-240 ± 10% VAC, 47-63 Hz. The unit is 1 RU, 16 deep. RX 0.32 A TX 0.86 A REF ON REF OFF MENU MODEL 2099 SOURCE/INSERTER CROSS TECHNOLOGIES INC. PS1 PS2 REMOTE ALARM OVEN EXT REF EXECUTE FRONT PANEL AC GND RX - LNB RF IN LNB FUSE FROM LNB F1 VDC on RF RF OUT 10 MHZ REF OUTPUT MONITOR AND CONTROL 5 4 3 2 1 9 8 7 6 10 MHZ EXT REF INPUT RF IN TX - SSPB SSPB FUSE F2 VDC on RF RF OUT TO SSPB J2 DS8 J1 J18 J10 J3 J4 DS7 J5 REAR PANEL FIGURE 1.1 Model 2099-218 Front and Rear Panels L-BAND TX IN SSPB +18VDC fuse L-BAND TX OUT EXT 10MHz AUTO INT 10MHz OCXO RX 0.32 A TX 0.86 A REF ON REF OFF CONTROLLER L-BAND RX OUT LNB +18VDC fuse L-BAND RX IN FIGURE 1.2 Model 2099-218 10MHz Source/Inserter Block Diagram 2099-218 Manual, Rev A. Page 3 01/19/11

1.2 Technical Characteristics TABLE 1.0 2099-218 MHz Source/Inserter Specifications* ---------10 MHz REFERENCE--------- -------RX & TX L-BAND INSERTION------- Output Characteristics (on L-band RF) Input/Output Characteristics Level +2 dbm ± 2 db Frequency 950-2150 MHz Harmonics <-30 dbc, <-40 dbc typ Impedance 75 Level to non-insert end <-20 dbm, <-30 dbm typ Return Loss >12 db, 0.95-1.5 GHz >10 db, 1.5-2.15 GHz Input/Output Characteristics (on BNC connectors) Insertion Loss < 1 db, 0.95-1.5 GHz Impedance, Return Loss 50 /75, 16 db < 2 db, 1.5-2.15 GHz Level +3 dbm ± 3 db Frequency Response ±1.0 db, 950-2150 MHz; Harmonics (Output) <-30 dbc, <-40 dbc typ ± 0.5 db, 36MHz BW (In Auto, Auto switches to internal when external source < -2 dbm) Internal Oscillator Stability Aging, per day Aging, per year Warm-up, 4 minutes Warm-up, 1 hour Tuning Adjust ± 0.01 ppm max over temp ± 0.001 ppm ± 0.1 ppm ± 0.1 ppm ± 0.01 ppm ± 0.5 ppm Phase Noise @ Freq dbc/hz 10Hz -110 100Hz -140 1kHz -149 10kHz -149 LNB, SSPB DC Power Characteristics Voltage/Current LNB +18 VDC, ±10%, 0.5 A. max.; SSPB +18 VDC, ±10%, 1.0 A. max. Call for other voltages Load Regulation ±5 % ---------CHASSIS/OTHER--------- Controls & Indicators INT/AUTO/EXT 10M Sel. direct readout LCD; manual or remote selection 10 MHz Insert Select direct readout LCD; manual or remote selection LNB, SSPB Current direct readout LCD; remote monitor Power, Alarm, Remote Green LED, Red LED, Yellow LED Oven Warm-up, Ext Ref Yellow LED, Yellow LED Remote RS232C, 9600 baud (RS485, option Q) Available Options -Q RS485/RS422 Remote Interface -W8 Ethernet Remote Interface -W18 Ethernet with SNMP Remote Interface Connectors/Impedance -D 50 BNC (RF) Other RF Connectors F-Type, 75 (female); 50 BNC (RF), option D 10 MHz Connectors BNC, 75 /50 (female) Alarm/Remote Connector DB9 (female) - NO or NC closure on Alarm Size 19 inch, 1RU standard chassis 1.75 H x 16.0 D Power 100-240 ±10% VAC, 47-63 Hz, 90 Watts max. *+10 C to +40 C; Specifications subject to change without notice. 2099-218 Manual, Rev A. Page 4 01/19/11

1.3 Environmental Use Information A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack. B. Mechanical Loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution. C. Elevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature. Therefore, consideration should be given to Tmra. D. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional space between unit may be required. E. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring. Appropriate consideration of equipment name plate rating should be used when addressing this concern. F. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connection to the Branch (use of power strips). G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 2099-218 Manual, Rev A. Page 5 01/19/11

1.4 Monitor and Control Interface A) Remote serial interface Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit. (RS-232C, RS-422, or RS-485 - option -Q) M&C Cable Diagram - Cross Technologies Frequency Converters Female DB-9 PC Com Port Male DB-9 2015/16/17 M&C Port 1 2 3 RX TX RX TX 1 2 3 4 DTR 4 5 6 7 8 9 SG DSR RTS CTS SG 5 6 7 8 9 Connector: Rear panel, DB-9 female. J10 Pinouts (RS-232C/422/485) Pin Function 1 Rx- 2 Rx+ (RS-232C) 3 Tx+ (RS-232C) 4 Tx- 5 GND 6 Alarm Relay: Common 7 Alarm Relay: Normally Open 8 Not Used 9 Alarm Relay: Normally Closed 2099-218 Manual, Rev A. Page 6 01/19/11

B) Status Requests Table 1.1 lists the status requests for the 2099-218 and briefly describes them. * PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below, should be used ONLY when RS-485, (OPTION-Q), is selected. Table 1.1 2099-218 Status Requests Command Syntax* Description Command Status {aas2} Returns {aas2bcdefghi} where: b = 0 (Internal), 1 (External), or 2 (Auto) Reference c = 1-10MHz inserted on upconverter RF (J5) d = 1-10MHz inserted on downconverter RF (J2) e = 1 - FAULT condition in Auto Reference mode ** f = 1 - Oven Alarm g = 1 - Summary Alarm h = 1 - Power Supply 1 Alarm i = 1 - Power Supply 2 Alarm LNB Current {aas3} Returns {aas3bb} where: bb = LNB current, range 00 to 50 (0 to 500 ma) SSPB Current {aas4} Returns {aas4bbb} where: bbb = SSPB current, range 000 to 100 (0 to 1000 ma) Reference Offset {aas8} Returns {aas8bbbb} where: bbbb = Reference Offset, range 500 to -500 ** FAULT! occurs when in Auto Reference mode and the external reference fails. 2099-218 Manual, Rev A. Page 7 01/19/11

C) Commands Table 1.2 lists the commands for the 2099-218 and briefly describes them. After a command is sent the 2099-218 sends a return > indicating the command has been received and executed. General Command Format - The general command format is {aacnd...}, where: { = start byte aa = Address (RS-485 only) C = 1 character, either C (command) or S (status) N = 1 character command or status request D = 1 character or more of data (depends on command) } = stop byte * PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below, should be used ONLY when RS-485, (OPTION-Q), is selected. Table 1.2 2099-218 Commands Command Syntax* Description External 10MHz {aacex} where x =: 0 for Internal 10MHz Reference signal 1 for External 10MHz Reference signal 2 for Auto 10MHz Reference Insert 10MHz on TX RF {aac5x} where x =: 0 to disable 10MHz transmitter insertion on RF (J5) 1 to enable 10MHz transmitter insertion on RF (J5) Insert 10MHz on RX RF {aac6x} where x =: 0 to disable 10MHz receiver insertion on RF (J2) 1 to enable 10MHz receiver insertion on RF (J2) Frequency Offset Adjust {aac8xxxx} where xxxx =: xxxx = 3 or 4 characters Range: 2000 to -2000 Enable Remote # Just # sign Disable Remote {aacr0} {CR and zero} 2099-218 Manual, Rev A. Page 8 01/19/11

2.0 Installation 2.1 Mechanical - The 2099-218 consists of one RF PCB housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switching, ± 12, +24, +5 VDC power supply provides power for the assemblies. A separate +24VDC power supply (+48VDC, option V48) provides power for the SSPB. The 2099-218 can be secured to a rack using the 4 holes on the front panel. Figure 2.0 shows how the 2099-218 is assembled. POWER SUPPLY 10.0000 MHz OVEN XO POWER SUPPLY FIGURE 2.0 2099-218 Mechanical Assembly 2099-218 Manual, Rev A. Page 9 01/19/11

2.2 Rear Panel Output Signals - Figure 2.1 shows the input and output connectors on the rear panel. J2 - RF IN 950-2150 MHz input from LNB. Provides LNB voltage and 10MHz ref insertion. F-Type, 75 BNC female connector. F1 - LNB FUSE 0.5A, Fast Blo, 1/4 Fuse. Installing fuse places power (500 ma max) on the RF IN (J2) center i J10 - RF OUT 950-2150 MHz. Capacitively coupled and looped from LNB RF input. F-Type, 75 BNC female connector. AC1 AC2 RX - LNB GND RF IN FROM LNB LNB FUSE F1 RF OUT 10MHZ REF OUTPUT VDC on RF J2 DS8 J10 J1 AC1/AC2 - POWER IN AC input for switching power supply. 100-240 ±10% VAC, 47-60 Hz. J10 - MONITOR AND CONTROL DB9 female connector. see Table 2.0. DS8 - LNB VDC INDICATOR Lights yellow when LNB voltage is present on the RF IN (J2) center pin. J3-10 MHz EXT REF 10 MHz external reference input, +3 dbm ±3 db. 50 /75 BNC female connector. J1-10MHZ REF OUTPUT 10 MHz reference output, +3dBm ±3 db. F-Type, 75 BNC female connector. TX - SSPB MONITOR AND CONTROL 10 MHZ EXT REF INPUT RF IN SSPB FUSE F2 RF OUT TO SSPB 5 4 3 2 1 9 8 7 6 VDC on RF J10 J3 J4 DS7 J5 J4 - RF IN 950-2150 MHz input. Capacitively coupled. F-Type, 75 BNC female connector. F2 - SSPB FUSE 1A, Fast Blo, 1/4 Fuse. Installing fuse places power (1 amp max) on the RF OUT (J5 ) center pin. DS7 - SSPB VDC INDICATOR Lights yellow when SSPB voltage is present on the RF OUT (J5) center pin. J5 - RF OUT TO SSPB 950-2150 MHz output. Looped from RF IN. Provides SSPB voltage and 10MHz ref insertion. F-Type, 75 BNC female FIGURE 2.1 2099-218 Rear Panel Outputs 5 4 3 2 1 9 8 7 6 TABLE 2.1 J11 J Pinouts (DB9) Pin Function 1 Rx- 2 Rx+ (RS-232C) 3 Tx+ (RS-232C) 4 Tx- 5 GND 6 Alarm Relay: Common 7 Alarm Relay: Open=ALARM 8 Not Used 9 Alarm Relay: Closed=ALARM 2099-218 Manual, Rev A. Page 10 01/19/11

2.3 Front Panel Indicators -The following are the front panel indicators. DS1 - REMOTE LED Yellow LED indicates remote operation. DS3 - ALARM LED Red LED indicates alarm condition.. LCD DISPLAY Shows LNB and SSPB currents and RF insertion status. Also used in MENU mode. S1 - MENU/EXECUTE BUTTON Press this to get into Program mode and press again to execute any changes. RX 0.32 A TX 0.86 A REF ON REF OFF MENU PS1 PS2 REMOTE ALARM OVEN EXT REF EXECUTE PS1 - PS2 POWER LED Green LED indicates presence of power. on power supply 1, 2 DS5 - OVEN LED Yellow LED indicates OCXO oven warming-up. DS2 - EXT REF LED Yellow LED indicates external reference is selected. S2 - VERT. TOGGLE Vertical toggle switch that adjusts values in the various menus when in Program Mode. Does not function in the normal display d S3 - HORIZ. TOGGLE Horizontal toggle switch that controls which values are being adjusted when in Program Mode. Does not function in the normal display mode. FIGURE 2.2 2099-218 Front Panel Controls and Indicators 2099-218 Manual, Rev A. Page 11 01/19/11

2.4 Installation / Operation 2.4.1 Installing and Operating the 2099-218 10MHz Source/Inserter 1. Connect RF IN (FROM LNB), J2, to the LNB (Figure 2.1). 2. Connect RF OUT (TO SSPB), J5, to the SSPB (Figure 2.1). 3. Install 500 ma fast-blo fuse in LNB fuseholder, F1, if power is to be inserted on RX RF IN (FROM LNB), J2. 4. Install 1A fast-blo fuse in SSPB fuseholder, F2, if power is to be inserted on TX RF OUT (TO SSPB), J5. 5. Connect 100-240 ±10% VAC, 47-63 Hz to AC connector on the back panel. 6. Be sure DS1 (green, POWER) is on (Figure 2.2). 7. Wait for DS5 (yellow, OVEN) to go off and/or contact closure at DB9 ALARM connector, J11, to occur to insure that the oscillator oven is stabilized. 8. AC Fuse - The fuse is a 5 mm X 20 mm, 2 amp slow blow (Type T) and is inserted in the far slot in the drawer below the AC input as shown in Figure 2.3. There is a spare fuse in the near slot. If a fuse continues to open, the power supply is most likely defective. FUSE DRAWER SPARE FUSE DRAWER AC Fuse - 2 amp slow blow (Type T 2A GDC), 5 mm X 20 mm INPUT~ ~ 100-240± 10%VAC 47-63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100-240 V~ FIGURE 2.3 Fuse Location and Spare Fuse 2099-218 Manual, Rev A. Page 12 01/19/11

2.5 Menu Settings 2.5.1 Functions This section describes operation of the front panel controls. There are three operator switches, the LCD display and alarm indicator LEDs. All functions for the equipment are controlled by these components. The functions are (see Figure 2.4): Power Up Normal Display Menu 1 Set Unit to Remote Operation Menu 2 Select Internal, External, or Auto 10 MHz Ref Menu 3 Select Transmit Reference Out Menu 4 Select Receive Reference Out Menu 5 Set RS-485 mode (option Q) Menu 6 Set RS-485 address (option Q) Menu 7 Reference Offset Save Menu When R is selected from any above menu or at the end Alarm indications appear on the LED (see Figure 2.2). All program changes must start with the operation of the Menu/Execute switch and must also end with the operation of the Menu/Execute switch verified by the SAVE SETTINGS? Menu. If this sequence is not followed, none of the changes will take effect. No program changes will be evident until they are verified at the SAVE SETTINGS? Menu 2099-218 Manual, Rev A. Page 13 01/19/11

2.5.2 Power-On Settings NOTE: THE LAST STATUS OF A UNIT IS RETAINED EVEN WHEN POWER IS REMOVED. WHEN POWER IS RESTORED, THE UNIT WILL RETURN TO IT'S PREVIOUS SETTINGS. When power is first applied, the LCD display goes through three steps. 1. The LCD goes black to show all segments are functioning. 2. The software version will be displayed. REV 1.00 3. The present RX (LNB) and TX (SSPB) current and the 10MHz RF insertion status is shown. RX 0.32A TX 0.86A REF ON REF OFF The unit is now operational and ready for any changes the operator may desire. 2.5.3 Control Switches 1. Menu/Execute - Any change to the programming of the unit must be initiated by pressing the Menu/Execute switch and completed by pressing the Menu/Execute switch. 2. Horizontal Switch - This switch is mounted so its movement is horizontal and moves the cursor left or right. 3. Vertical Switch - This switch is mounted so its movement is vertical and will alternately turn any ON/OFF function (such as REMOTE) on or off regardless of the direction operated. In the case of the INT/EXT/AUTO reference setting, the vertical switch will scroll between the three selections. 2099-218 Manual, Rev A. Page 14 01/19/11

Power Up ON POWER UP REV 1.00 Normal Display NORMAL DISPLAY RX 0.32 A REF ON TX 0.86 A REF OFF PUSH BUTTON Menu 1 Set Unit to Remote Operation Menu 2 Select 10 MHz Reference INT, EXT, or AUTO Menu 3 Select Transmit Reference Out Menu 4 Select Receive Reference Out Menu 5 Set Remote Mode (option -Q) Menu 6 Set RS-485 Address (option -Q) PUSHING MENU/EXECUTE SEQUENCE REMOTE OFF R SCROLL <> SCROLL INT REF R SCROLL <> SCROLL TX REF OUT OFF R SCROLL <> SCROLL RX REF OUT OFF R SCROLL <> SCROLL RS 485 OFF R SCROLL <> SCROLL ADDRESS = 00 R SCROLL <> SCROLL PUSH BUTTON PUSH BUTTON PUSH BUTTON PUSH BUTTON PUSH BUTTON PUSH BUTTON Menu 7 Reference Offset FREQ ADJUST Offset = +000 R SCROLL <> PUSH BUTTON Save? When R is selected from any above menu or at the end SAVE SETTINGS? Y N SCROLL <> PUSH BUTTON Figure 2.4 Menu Display and Sequence 2099-218 Manual, Rev A. Page 15 01/19/11

CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com 2011 Printed in USA 2099-218 Manual, Rev A. Page 16 01/19/11