K-EYE K10 HCR - K-EYE K20 HCR K-EYE S10 HCR - K-EYE S20 HCR

Similar documents
K-EYE K10 HCR - K-EYE K20 HCR K-EYE S10 HCR - K-EYE S20 HCR

AXCOR BEAM 300 INSTRUCTION MANUAL INDEX

K-EYE K10 HCR K-EYE K20 HCR

HEPIKOS INSTRUCTION MANUAL. INDEX Page Contents

AXCOR SPOT 300 INSTRUCTION MANUAL INDEX

SUPERSHARPY INSTRUCTION MANUAL. INDEX Page Contents

SCENIUS PROFILE INSTRUCTION MANUAL. INDEX Page Contents

SHARPY WASH 330 SHARPY WASH 330 PC

EVERY COLOR, EVERY NUANCE AND EVERY SHADE WITH THE HIGHEST CRI

SHARPY INSTRUCTION MANUAL. INDEX Page Contents

ALPHA BEAM 700 INSTRUCTION MANUAL. INDEX Page Contents

ALPHA SPOT HPE 700 INSTRUCTION MANUAL. INDEX Page Contents

A.LEDA B-EYE K10 EASY A.LEDA B-EYE K10 A.LEDA B-EYE K20

INSTRUCTION MANUAL INDEX

A.LEDA B-EYE K10 CC A.LEDA B-EYE K20 CC

ALPHA BEAM 700 INSTRUCTION MANUAL INDEX

INSTRUCTION MANUAL INDEX

SHARPY WASH 330 INSTRUCTION MANUAL INDEX

SHARPY WASH 330 SHARPY WASH 330 PC

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

SCENIUS SPOT INSTRUCTION MANUAL. INDEX Page Contents

SCENIUS SPOT INSTRUCTION MANUAL. INDEX Page Contents

aorun manual V2.0 MARCH 2018

INSTRUCTION MANUAL INDEX

LED Thunder S-150 Code 1097

STORMY STORMY CC. The latest LED technology meets the charm of a classic strobe STORMY C71090 STORMY CC C71091 INSTRUCTION MANUAL.

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

INSTRUCTION MANUAL INDEX

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

SHOWLINE SL BEAM 100 LED LUMINAIRE SPECIFICATIONS.

SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

Spiider THE NEXT BIG THING FROM ROBE!

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

www. eklights.com Guangzhou Liangyi Lighting Equipments Co.,Ltd. 37 Gongyedadao, Xinhua, Huadu, Guangzhou PC:510800

pixelpatt Light source 7x 30W RGBW multichips Effects Individual control of each RGBW pixel, Tungsten lamp emulation

A.LEDA B-EYE K10 EASY A.LEDA B-EYE K10 A.LEDA B-EYE K20

LED Spot 300W. Please read this user manual before your operation

SHOWLINE SL PUNCHLITE 220 LED LUMINAIRE SPECIFICATIONS.

L5-C LED Fresnel L I G H T I N G - P R O D U C T S P E C I F I C A T I O N V2.2

Altman Lighting AP-150 RGBW Par Specification

aorun manual V1.0 OCTOBER 2017

Fusion 120 Zoom. User Manual. Order code: EQLED068

AuraBeam 150 LED. User Manual KEEP THIS MANUAL FOR FUTURE NEEDS

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

INSTRUCTION MANUAL INDEX

Spectra Batten (Order code: LEDJ95)

LED MOVING HEAD LedWash. 36 x 10w RGBW 4in1 Zooming USER MANUAL. Version 1.0 beta

Color mixing or White-light LED (Light Emitting Diode) ERS-style product

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

WASH MOVING HEAD M7W15RGBW USER MANUAL. For safety, please read this user manual carefully before initial use.

SHOWLINE SL PAR 155 LED LUMINAIRE SPECIFICATIONS.

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

SOFT LED 4 Vari-White INSTRUCTION MANUAL

LED SPOT HEAD USERS GUIDE

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

BSL HELIOS USERS GUIDE

Hex-color RGBAW+UV LED strip light

PRODUCT SPECIFICATIONS

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

LED SPOT HEAD USERS GUIDE

S30-C LED Soft Light LIGHTING - PRODUCT SPECIFICATION V1.0

Altman Lighting Spectra Cyc 50 Specification

Stratos Duo RGB. User Manual. Order code: EQLED371

The ideal replacement solution to the VL3500 Series (profile) spot or any other 1,000W to 1,500W lamped professional moving profile light.

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

minipointe is a tiny agile air cutter specifically designed to produce sharp beam and aerial effects especially in venues constrained by size.

DMX LED light effect with 4 lenses

2002 Martin Professional A/S, Denmark.

BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE

SHOWLINE SL epar 180 LUMINAIRE SPECIFICATIONS.

Sirio 150 / 150DV. Code 02E010 - Sirio 150 Code 02E011 - Sirio 150DV OPERATING INSTRUCTIONS. COEF srl. Revision 1

TABLE OF CONTENTS PART 5 APPENDIX TROUBLE SHOOTING MAINTENANCE A CTIVATE THE PASSWORD...13.

G-SPOT MOVING HEAD PROFILE

LED ZOOM PAR Please R ead O ver T his M anual B efore O perating T he L ight F ixture.

PRODUCT SPECIFICATIONS

SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS.

USER MANUAL. B-EYE Light. Please Read Over This Manual Before Operating The Light Fixture

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

Quick Reference Guide

ORDER CODE: EQLED65 USER MANUAL

PART 1 PRODUCT (GENERAL)...1.

LED Moving Head GTD-LMZ1512. User s Manual

LED BEAM HEAD USERS GUIDE

S30-RP LED Soft Light

MHL-1410WISPOT 14X 10W QUAD DMX 2.4GHZ

Stage Wash 7x 10W LED Moving Head (RGBW)

BROTHER, BROTHER & SONS

USER MANUAL (SSDL-3201RGB)

PRODUCT SPECIFICATIONS

LEDWash RGBW USER MANUAL

MAC ALLURE PROFILE ONE BEAM. 7 SEGMENTS. LIMITLESS COLORS. SPEC SHEET KEY MESSAGES BRIGHT VIBRANT COLORS FIRST PIXELATED SPOT BROADCAST SAFE

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

SquareLED - Aura Bar & Matrix Beam Light 100

User Manual MAINTENANCE AND CLEANING. CAUTION Disconnect from mains before starting maintenance operation. KEEP THIS MANUAL FOR FUTURE NEEDS

HEX16 Strip User Manual

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating

Transcription:

ENGLISH K-EYE K0 HCR - K-EYE K20 HCR K-EYE S0 HCR - K-EYE S20 HCR C6430 C6440 C7320 C730 INSTRUCTION MANUAL PRELIMINARY INDEX Page Contents 2 Safety information 3 Unpacking and preparation 4 Installation and start-up Congratulations on choosing a Claypaky product! We thank you for your custom. Please note that this product, as all the others in the rich Claypaky range, has been designed and made with total quality to ensure excellent performance and best meet your expectations and requirements. 5 Control panel 9 Maintenance Technical information

SAFETY INFORMATION EN SAFETY INFORMATION IMPORTANT: Claypaky recommends you carefully read and keep the safety information on this product, also available in digital format at the following link: http://www.claypaky.it/en Ref: [FIS06 - Safety Information A.leda K-EYE series] IT INFORMAZIONI DI SICUREZZA IMPORTANTE: Claypaky raccomanda di leggere accuratamente e conservare le informazioni di sicurezza relative a questo prodotto, sempre reperibili in versione digitale al seguente link: http://www.claypaky.it/en/download Rif: [FIS06 - Safety Information A.leda K-EYE series] DE INFORMATIONEN ZUR SICHERHEIT WICHTIG: Claypaky empfiehlt, die Sicherheitsinformationen bezüglich dieses Produkts genau zu lesen und aufzubewahren. Sie sind in Digitalversion immer unter folgendem Link auffindbar: http://www.claypaky.it/en/download Ref: [FIS06 - Safety Information A.leda K-EYE series] ES INFORMACIONES DE SEGURIDAD IMPORTANTE: Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este producto. Además, está disponible una versión digital de la misma en el siguiente enlace: http://www.claypaky.it/en/download Ref: [FIS06 - Safety Information A.leda K-EYE series] FR CONSIGNES DE SÉCURITÉ IMPORTANT: Claypaky recommande de lire attentivement et de conserver les informations de sécurité relatives à ce produit, disponibles en version digitale au lien suivant: http://www.claypaky.it/en/download Réf. : [FIS06 - Safety Information A.leda K-EYE series] RU ИНСТРУКЦИЮ ПО ТЕХНИКЕ БЕЗОПАСНОСТИ ВАЖНО: Claypaky рекомендует внимательно прочитать и сохранить инструкцию по технике безопасности данного изделия, которая всегда доступна в электронном формате по следующей ссылке: http://www.claypaky.it/en/download Наименование: [FIS06 - Safety Information A.leda K-EYE series] 2

UNPACKING AND PREPARATION 2 x 8302/805 Packing contents - Fig. 2 3 LOCKED UNLOCKED 45 45 45 45 45 45 90 90 90 90 PAN Mechanism Lock and Release (every 90 ) - Fig. 2 TILT Mechanism Lock and Release (every 45 ) - Fig. 3 3

INSTALLATION AND START-UP 4 Installing the projector - Fig. 4 The projector can be installed on the floor resting on special rubber feet, on a truss or on the ceiling or wall. WARNING: with the exception of when the projector is positioned on the floor, the safety cable must be fitted. (Cod. 0504/003 available on request). This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base. 5 2 2 3 Connecting and disconnecting power cable - Fig. 5 4

CONTROL PANEL 6 Mains Connecting to the mains supply - Fig. 6 7 DMX 52 5 PIN 5 4 3 2 SCREEN SIGNAL SIGNAL Connecting to the control signal line (DMX) - Fig. 7 Use a cable conforming to specifications EIA RS-485: 2-pole twisted, shielded, 20Ohm characteristic impedance, 22-24 AWG, low capacity. Do not use microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 3/5-pin male/female connectors. A terminating plug must be inserted into the last projector with a resistance of 20Ohm (minimum /4 W) between terminals 2 and 3. IMPORTANT: The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the shield braid and to pin of the connectors. 8 Fixture ID 2 Dmx Address Warning Message Switching on the projector - Fig. 8 Press the switch. The projector starts resetting the effects. At the same time, the following information scrolls on the display: Model... Firmware Version X.X.X Date - Hour xxx (Fixture ID) Dmx Address xxx System errors E:... W:... On conclusion of resetting in case of absence of the dmx signal, Pan and Tilt move to the Home position (Pan 50% - Tilt 50%). The control panel (Fig. 7) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two conditions: rest status and setting status. When it is in the rest status, the display shows the projector s DMX address and the Fixture ID address (if set). During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status. It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the key will be cancelled. F 5

9 Reversal of the display - Fig. 9 To activate this function, press UP B and DOWNCkeys simultaneously while the display is in the rest mode. This status will be memorised and maintained even for the next time it will be switched on. To return to the initial state, repeat the operation all over again. Setting the projector starting address On each projector, the starting address must be set for the control signal (addresses from to 52). The address can also be set with the projector switched off. Setting the projector Fixture ID On each projector, the Fixture ID address must be set for an easy identification of the fixtures in an installation (ID from to 255). The Fixture ID address can be set with the projector switched off. Functions of the buttons - Using the menu F Confirms the displayed value, or activates the displayed function, or enters the successive menu. CDOWN Decreases the value displayed (with auto-repetitions) or passes to the next item in the menu. BUP Increases the value displayed (with auto-repetitions) or passes to the previous item in a menu. DLEFT Return to the top level. Commute from units, tens, hundreds, in the "Address", "Fixture ID" and "Calibration" menù. ERIGHT USING THE MENU: ) Press F once Main Menu appears on the display. 2) Use the UP B and DOWN C keys to select the menu to be used: Setup (Setup Menu): To set the setting options. Option (Option Menu): To set the operating options Informations (Informations Menu): To read the counters, software version and other information. Manual Control (Manual control Menu): To trigger the test and manual control functions. Test (Test Menu): To check the proper functionning of effects Advanced (Advanced Menu): Access to the "Advanced menu" is recommended for a trained technical personnel. 3) Press F to display the first item in the selected menu. 4) Use the UP B and DOWN C keys to select the MENU items. Setting addresses and options with the projector disconnected The projector s DMX address, as well as other possible operating options, can also be set when the appliance is disconnected from the electricity supply. All that is needed is to press F to momentarily activate the display and thus access the settings. Once the required operations have been carried out, the display will switch off again after a wait time of 30 seconds. 6

0 WARNING: no alcohol Light collimation system This product contains internal light collimation system. Avoid intense light from any angle. CAUTION: To avoid damage to the internal parts of the fixture when the fixture is not working, is recommended to turn the head down before turning the fixture off, so that the front lenses of the fixture are invested as little as possible from the sun. Set Zoom channel to 255-bit before turning off the projector to facilitate the packaging of the projector. It is recommended not to use compressed air with more than 4 atmospheres for cleaning the internal parts of the fixture, led board area. This is to avoid damaging electronic components. To ensure optimal operation and performance for a long time it is essential to periodically clean the parts subject to dust and grease deposits. The frequency with which the following operations are to be carried out depends on various factors, such as the amount of the effects and the quality of the working environment (air humidity, presence of dust, salinity, etc.). It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations: - General cleaning of internal parts. - Restoring lubrication of all parts subject to friction, using lubricants specifically supplied by Claypaky. - General visual check of the internal components, cabling, mechanical parts, etc. - Electrical, photometric and functional checks; eventual repairs. Cleaning the lenses Only use neutral soap and water to clean the lenses, then dry it carefully with a soft, non-abrasive cloth. (WARNING: the use of alcohol or any other detergent could damage the lenses). Continue 7

2 6 3 4 5 Battery removal - Fig. This product contains a rechargeable battery. To preserve the environment, please dispose the battery at the end of its life according to the regulation in force. 8

MAINTENANCE 2 3 4 2 Opening the covers - Fig. 2 3 2 Removing/Assembling the lens unit - Fig. 3 9 Continue

4 Replacing the line actuator - Fig. 4 0

Two accessories are available for additional control of the beam: ACCESSORIES TOP HAT Motorized Top Hat, which is applied to the front lens and pulls out automatically together with the zoom. It works as frost/gel holder as well. C2096 Kit Opzionale Top Hat K-EYE K0 HCR FROST/GEL HOLDER You can apply a frost diffuser or a gel by using the optional holder C2094 Kit telaio per filtro K-EYE K0 HCR C2097 Kit Opzionale Top Hat K-EYE K20 HCR C2095 Kit telaio per filtro K-EYE K20 HCR CAUSE AND SOLUTION OF PROBLEMS THE PROJECTOR WILL NOT SWITCH ON ELECTRONICS NON-OPERATIONAL DEFECTIVE PROJECTION REDUCED LUMINOSITY POSSIBLE CAUSES No mains supply. LED exhausted or defective. Signal transmission cable faulty or disconnected. Incorrect addressing. Fault in the electronic circuits. Lenses broken Dust or grease deposited. Check the power supply voltage. Call an authorised technician. Replace the cables. Check addresses (see instructions). Call an authorised technician. Call an authorised technician. Clean (see instructions). CHECKS AND REMEDIES PROBLEMS

TECHNICAL INFORMATION K-EYE K0 HCR POWER SUPPLIES AC power input Neutrik PowerCON TRUE (IP65) 5/230V 50/60 Hz INPUT POWER 450 VA @230V, 50Hz TOTAL LUMEN OUTPUT 5,500 lumen LIGHT SOURCE Source: 6-color LED module LED Type: R+G+B+Cyan+Amber+Lime Number of LEDs: 9 (K0) LED Life Expectancy: min. 50,000 hours Typical Lumen Maintenance: 70@50,000 hours CRI up to 97 MOTORS Stepper motors, operating with microsteps, totally microprocessor controlled CHANNELS 27 control channels INPUTS DMX 52 - Ethernet OPTICS Optics 6-color LED module + rod-bar mixing system + front lens Zoom 7-53, linear and motorized NOISE LEVEL 40.5 dba (background noise 34 dba) COLOR SYSTEM & EFFECTS Color system R+G+B+Cyan+Amber+Lime LED module CTO Linear from 7500K to 2500K (CTO controlled mode plus RAGCB correction) Control of the colors RAW mode, HSL mode, RGB mode, CMY mode - RAW mode Enable specific control of each color - HSL mode Color control function, based on algorithm - HSL parameters HUE, HUE fine, Saturation, Crossfade, Path, Tint - RGB mode The projectors works in the same way as a classical RGB fixture - CMY mode The projectors works in the same way as a classical CMY fixture Halo Emulation 750W, 000W, 200W, 2000W, 2500W lamp emulation Gamma Wave Different chromatic curves for each color Macro Dedicated color macro channel with 80 preselected colors Dimmer 6 bit electronic and linear Strobe 24 flash/sec. Electronic, instant open and blackout. Variable speed pulsation IP RATING IP 20 - Protected against the entry of solid bodies larger than 2mm (0.47 ); No protection against the entry of liquids. THERMAL SPECIFICATIONS Minimum distance of illuminated objects 0.2 meters (8 ) Minimum distance from flammable materials 0.2 meters (8 ) Max ambient temperature 40 C (04 F) Max temperature of the external surface 90 C (94 F) Safety devices Bipolar circuit breaker with thermal protection. Automatic break in power supply in case of overheating. Forced ventilation with axial fans. RIGGING AND INSTALLATION Working position Any Hanging system 2x fast-lock omega clamps (/4 turn) on the base Optional 48-5mm, max300kg clamps; Ø 4mm, length 680mm safety cable CONTROL AND PROGRAMMING DMX 52 control channels 27 Control signal USITT DMX 52 Protocols RDM, WebServer and Art-Net Display Graphic LCD backlit b/w Display Display battery Long life self-charging buffer battery 2 Pan/Tilt Resolution 6 bit Dimmer Resolution 6 bit Movement control vectorial DMX signal connection 5 pole XLR input and output Firmware update Software upload through DMX input CONSTRUCTION Structure in aluminum with die-cast plastic cover. Handles Two side handles for transportation Device locking PAN and TILT mechanisms for transportation. MOVEMENT PAN range 540 TILT range 244 PAN Resolution PAN = 2. - PAN FINE = 0.008 TILT Resolution TILT = 0.960 - TILT FINE = 0.004 ELECTRONICS Long life self-charging buffer battery Function reset from the lighting desk AUTOTEST function from menu Electronic monitoring with status error Cooling system monitoring DMX level monitoring on all channels Internal data transmission diagnostics Firmware Upgrade with no power - Firmware upload from another fixture Base colors control: primary colors in raw mode, CTO controlled mode plus RAGCB correction Additional Color control functions: HSL Protocols/Functions: RDM, Web Server, ArtNet Algorithm for HCR: CRI>99 over TC range from 2500 K to 8000 K Source calibration in the production line Flicker free Default silent mode Macro functions WEIGHT 6.5 Kg (36.4 lbs)

K-EYE K20 HCR POWER SUPPLIES AC power input Neutrik PowerCON TRUE (IP65) 5/230V 50/60 Hz INPUT POWER 750 VA @230V, 50Hz TOTAL LUMEN OUTPUT,000 lumens LIGHT SOURCE Source: 6-color LED module LED Type: R+G+B+Cyan+Amber+Lime Number of LEDs: 37 LED Life Expectancy: min. 50,000 hours Typical Lumen Maintenance: 70@50,000 hours CRI up to 97 MOTORS Stepper motors, operating with microsteps, totally microprocessor controlled CHANNELS 27 control channels INPUTS DMX 52 - Ethernet OPTICS Optics 6-color LED module + rod-bar mixing system + front lens Zoom 7-53, linear and motorized NOISE LEVEL 38.5 dba with FanSpeedMode Auto (background noise 35 dba) COLOR SYSTEM & EFFECTS Color system R+G+B+Cyan+Amber+Lime LED module CTO Linear from 7500K to 2500K (CTO controlled mode plus RAGCB correction) Control of the colors RAW mode, HSL mode, RGB mode, CMY mode - RAW mode Enable specific control of each color - HSL mode Color control function, based on algorithm - HSL parameters HUE, HUE fine, Saturation, Crossfade, Path, Tint - RGB mode The projectors works in the same way as a classical RGB fixture - CMY mode The projectors works in the same way as a classical CMY fixture Halo Emulation 750W, 000W, 200W, 2000W, 2500W lamp emulation Gamma Wave Different chromatic curves for each color Macro Dedicated color macro channel with 80 preselected colors Dimmer 6 bit electronic and linear Strobe 24 flash/sec. Electronic, instant open and blackout. Variable speed pulsation IP RATING IP 20 - Protected against the entry of solid bodies larger than 2mm (0.47 ); No protection against the entry of liquids. THERMAL SPECIFICATIONS Minimum distance of illuminated objects 0.2 meters (8 ) Minimum distance from flammable materials 0.2 meters (8 ) Max ambient temperature 40 C (04 F) Max temperature of the external surface 90 C (94 F) Safety devices Bipolar circuit breaker with thermal protection. Automatic break in power supply in case of overheating. Forced ventilation with axial fans. RIGGING AND INSTALLATION Working position Any Hanging system 2x fast-lock omega clamps (/4 turn) on the base Optional 48-5mm, max300kg clamps; Ø 4mm, length 680mm safety cable CONTROL AND PROGRAMMING DMX 52 control channels 27 Control signal USITT DMX 52 Protocols RDM, WebServer and Art-Net Display Graphic LCD backlit b/w Display Display battery Long life self-charging buffer battery Pan/Tilt Resolution 6 bit Dimmer Resolution 6 bit Movement control vectorial DMX signal connection 5 pole XLR input and output Firmware update Software upload through DMX input CONSTRUCTION Structure in aluminum with die-cast plastic cover. Handles Two side handles for transportation. Device locking PAN and TILT mechanisms for transportation. MOVEMENT PAN range 540 TILT range 244 PAN Resolution PAN = 2. - PAN FINE = 0.008 TILT Resolution TILT = 0.960 - TILT FINE = 0.004 ELECTRONICS Long life self-charging buffer battery Function reset from the lighting desk AUTOTEST function from menu Electronic monitoring with status error Cooling system monitoring DMX level monitoring on all channels Internal data transmission diagnostics Firmware Upgrade with no power - Firmware upload from another fixture Base colors control: primary colors in raw mode, CTO controlled mode plus RAGCB correction Additional Color control functions: HSL Protocols/Functions: RDM, Web Server, ArtNet Algorithm for HCR: CRI>99 over TC range from 2500 K to 8000 K Source calibration in the production line Flicker free Default silent mode Macro functions WEIGHT 22.5 Kg (49.6 lbs) 3

CLAY PAKY S.p.A. - Via Pastrengo, 3/b - 24068 Seriate (BG) Italy - Tel. +39-035-6543 - Fax +39-035-30876 - www.claypaky.it IST0/00 EN - PRELIMINARY 06 /207