Air cooled Outdoor installation R-410A Hermetic Scroll Ice protection system FREE-COOLING HydroPack ECOBreeze Electronic expansion valve

Similar documents
Air cooled water chillers with screw compressors From 134 kw to kw

Split System Air Conditioner

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

Küba comfort DP. Draught-free ventilation and extremely quiet operation

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Model KT 115 Cooling incubators with thermoelectric cooling

EVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow

YVAA Air-cooled VSD screw chiller

Model KBF 115 Constant climate chambers with large temperature / humidity range

Model KT 53 Cooling incubators with thermoelectric cooling

Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade

Model KBF 1020 Constant climate chambers with large temperature / humidity range

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

Fluid Cooling P-BAR b Industrial BOL Series

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

Agilent High Capacity RV Pumps & Roots Pumping Systems

Features. Specifications. Finish. Notes

Series description: Wilo-Jet HWJ

GENESIS Indoor Air Conditioners

2.9 Sigma/ 2 Plunger Metering Pumps

Optical Cryostat - Omniplex TM

E-VENT. The turnkey plasma cutting machine. Technica l progress in the design

Series description: Wilo-Sub TWU 3 HS

Model KT 170 Cooling incubators with thermoelectric cooling

New Eppendorf Freezers Sample security meets the latest in energy efficiency. Stay Cool. CryoCube ULT Freezers: Efficiency has a new name

Just cool with green: GEA Küba market SP. The new standard for basic refrigeration applications

WCHE BTU/Hr Watts

Model KBF P 240 Humidity test chambers with ICH-compliant light source

YLAA YLAA0175 AIR-COOLED SCROLL CHILLERS STYLE A, B or C (60 Hz) TON KW

Ultra Quiet Series Electric Air Handler

Scan-Line 8. PRICE LIST 2017 EN (VAT EXCLUDED) Valid from

TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments

A3H series. Energy and cost efficient solutions for the most demanding applications. Multi-stage. Roots pumps

GENESIS Indoor Air Conditioners

Thermo Scientific Merlin Recirculating Chillers

User interface. Abbreviations / Meanings

CR BTU/Hr. 469 Watt. CR and 4000 BTU/Hr. 791 and 1172 Watts CR & 8000 BTU/Hr and 2344 Watts.

Roof-mounted Blue e+ cooling unit Integration solution VX25

T BTU/Hr Watts. T BTU/Hr Watts. Finish. Accessories. Options

ECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor

New. Large tank 25l Manual start/electric starter. New New New New. Electric starter/ Electric starter/ 2x 230 V shock-

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

WCHE BTU/Hr Watts

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

CME500 SERVICE PARTS

AC diagonal module Ø 200 mm

Küba Blue Line Aircoolers Küba SG commercial

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

WCHE BTU/Hr Watts

MAW218D7. User s manual. Pol.Ind.Norte-Perpinyà, TERRASSA (Barcelona-SPAIN)

Variable speed drives Altivar 38 Mastering elements for more comfort

LED MODULES READYLINE DL

Color mixing or White-light LED (Light Emitting Diode) ERS-style product

MICROPROCESSOR CALCULATION MODULE - S2000

Cooling systems for ORBIMAT

Optical Cryostat - Economy

ULTRALOW TEMPERATURE FREEZERS -86 C

PANEL RADIATORS - TECHNICAL MANUAL

All-Glass Sliding-System SF20

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

Sigma 3-16L Sigma 3-16KL

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

P Output Ratings. Dimensions and Weights. Prime Rating

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

User Guide Stand-Alone Metering for OptiPlant

P Output Ratings. Dimensions and Weights. Prime Rating

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Engineered to meet your needs T he oldest name in stud welding,

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

T BTU/Hr Watts

MultiZone reverse cycle systems

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

Climate Solutions Handbook

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

R407C compressors. New: Semi-hermetic compressors for air-conditioning applications with R407C

Forced Convection Laboratory Ovens

T BTU/Hr Watts

Product Data Sheet 4650 N-465

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

P550-3L. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

SPINNER BROADCAST EXPLANATION OF THE MULTI CHANNEL COMBINER SPECIFICATIONS

P Output Ratings. Dimensions and Weights. Prime Rating

P88-3. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P400-3L. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

T-Series Indoor/Outdoor Air Conditioners. Keeps its cool during peak heat loads and hot weather. Product Overview. T-Series A/C

P Output Ratings. Dimensions and Weights. Prime Rating

T BTU/Hr Watts

Optimized Cooling Solution, Horizon. SU48X Series mm Pixel Pitches. Long Lifetime.

-1.1/49 0 C. 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 06TS**

M BTU/Hr Watts. Finish. Options

P65-5. Output Ratings. Dimensions and Weights. Prime Rating

Model KBF 720 Constant climate chambers with large temperature / humidity range

Transcription:

WSAT-XEE WSAN-XEE Water chiller WSAT-XEE: cooling only WSAN-XEE: reversible heat pump Air cooled Outdoor installation Capacity from 90 to 216 kw 352 802 ELFOEnergy Large² new generation ELFOEnergy Large 2 water chillers and heat pumps provide the highest seasonal efficiency. They re designed to be installed outdoor and feature uneven scroll compressors mounted in the same circuit, electronic expansion valves and high efficiency plate type evaporators. ELFOEnergy Large 2 shows an unmatched seasonal efficiency ESEER and is available in two versions: EXCELLENCE and PREMIUM. The standard version EXCELLENCE offers the highest efficiency both at full and at part load. Also the PREMIUM version offers high efficiency at part load but favour also the compact dimensions being therefore extremely competitive. Thanks to its features, ELFOEnergy Large 2 offers: self-adaptability in different load conditions, thanks to the availability of several capacity steps and the adjustment logic developed for maximum efficiency and minimum wear very high overall reliability, thanks to the consolidated construction choices and the use of industrially-made products lower sound emissions, achieved thanks to the optimal sizing of the exchange surfaces and the use of high efficiency fans with winglets quick and easy installation thanks to the quick connections with the main circuit, electrical wiring enablement and complete functional testing before delivery. The units can also be supplied with pump assemblies, partial heat recovery and inertial storage tank already installed on board, bringing together all the system s main components in a single solution. Unit listed on www.eurovent-certification.com functions and features AIR R-410A FC HYDRO PACK ECO BREEZE EEV Cooling only (WSAT-XEE) Heat pump (WSAN-XEE) Air cooled Outdoor installation R-410A Hermetic Scroll Ice protection system FREE-COOLING HydroPack ECOBreeze Electronic expansion valve dimensions and clearances B1 B B2 A1 C A A2 CAUTION! For trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas. Size WSAT-XEE SC-EXC A - Length mm SC-EXC B - Width mm SC-EXC C - Height mm SC-EXC A1 mm SC-EXC A2 mm SC-EXC B1 mm SC-EXC B2 mm SC-EXC Operating weight kg SC-PRM Operating weight kg 3075 3075 3075 4025 4025 4025 4025 5025 5025 1097 1097 1097 1097 1097 1097 1097 1097 1097 1805 1805 1805 1805 1805 1805 1805 1805 1805 1000 1000 1000 1000 1000 1000 1000 1000 1000 700 700 700 700 700 700 700 700 700 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 896 933 1024 1207 1234 1256 1302 1497 1544 778 802 892 924 963 984 1087 1295 1324 Size WSAN-XEE A - Length mm 3075 3075 3075 3075 3075 4025 4025 5025 5025 B - Width mm 1097 1097 1097 1097 1097 1097 1097 1097 1097 C - Height mm 1805 1805 1805 1805 1805 1805 1805 1805 1805 A1 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 A2 mm 700 700 700 700 700 700 700 700 700 B1 mm 1350 1350 1350 1350 1350 1350 1350 1350 1350 B2 mm 1350 1350 1350 1350 1350 1350 1350 1350 1350 SC Operating weight kg 915 975 1059 1101 1126 1326 1341 1549 1564 EN Operating weight kg 915 975 1059 1101 1126 1326 1341 1549 1564 The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations, refer to the relative Technical Bulletin. SC-EXC Compressors soundproofing (SC)-Excellence SC-PRM Compressors soundproofing (SC)-Premium SC Compressors soundproofing (SC) EN Extremely low noise (EN)

versions and configurations Low temperature: - Low temperature: not required (Standard) B Water low temperature Energy recovery: - Energy recovery: not required (Standard) D Partial energy recovery R Total energy recovery Acoustic configuration: SC Acoustic configuration with compressor soundproofing (Standard) EN Extremely low noise acoustic configuration double set point: - Double set point: not required (Standard) DSP Double set point DSPB Double set point for water low temperature Version (wsat-xee only): EXC Excellence (Standard) PRM Premium free-cooling (wsat-xee only): - FREE-COOLING: not required (Standard) FCD Direct FREE-COOLING External section fan consumption reduction: CREFB Device for consumption reduction of the external section ECOBREEZE fans (Standard) CREFP Device for consumption reduction of the external section at variable speed (phase-cutting) technical data REF-DG13A001GB-00 Size WSAT-XEE SC-EXC Cooling capacity (EN14511:2011) (1) kw SC-EXC Total power input (EN14511:2011) (1) kw SC-EXC EER (EN 14511:2011) (1) - SC-EXC ESEER (1) - SC-PRM Cooling capacity (EN14511:2011) (1) kw SC-PRM Total power input (EN14511:2011) (1) kw SC-PRM EER (EN 14511:2011) (1) - SC-PRM ESEER (1) - SC-EXC Sound pressure level (2) db(a) SC-PRM Sound pressure level (2) db(a) Refrigerant circuits Nr No. of compressors Nr Type of compressors - Standard power supply V Size WSAN-XEE SC Cooling capacity (EN14511:2011) (1) kw SC Total power input (EN14511:2011) (1) kw SC EER (EN 14511:2011) (1) - SC eseer (1) - SC Heating capacity (EN14511:2011) (3) kw SC Total power input (EN14511:2011) (3) kw SC cop (EN 14511:2011) (3) - SC Refrigerant circuits Nr SC No. of compressors Nr SC Type of compressors - SC Standard power supply V SC Sound pressure level (2) db(a) EN Sound pressure level (2) db(a) 95,6 109 120 129 140 152 174 195 216 30,6 34,8 38,8 40,9 45,0 49,0 55,8 62,3 69,6 3,12 3,13 3,10 3,15 3,12 3,10 3,12 3,13 3,11 4,22 4,30 4,22 4,21 4,24 4,10 4,26 4,16 4,32 89,7 101 111 119 130 143 159 185 203 32,6 37,7 42,0 44,2 48,0 53,2 61,0 66,9 75,9 2,75 2,67 2,64 2,70 2,71 2,69 2,61 2,76 2,67 3,91 3,95 3,90 4,03 4,02 3,99 3,90 3,99 3,79 67 67 68 68 68 69 69 70 70 67 67 67 67 68 68 68 69 69 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 84,4 96,7 105 114 122 140 156 183 202 32,7 36,5 41,3 43,6 48,5 51,3 60,8 66,9 76,5 2,58 2,65 2,55 2,61 2,52 2,73 2,56 2,73 2,64 3,43 3,56 3,54 3,54 3,56 3,49 3,40 3,35 3,31 100 116 127 136 147 165 183 212 234 32,6 36,7 40,4 42,1 45,8 51,0 57,1 65,3 72,6 3,08 3,16 3,14 3,23 3,20 3,24 3,21 3,25 3,23 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 67 67 67 67 67 68 68 71 71 62 63 64 64 64 65 65 66 66 Notes (1) Data calculated in compliance with Standard EN 14511:2011 referred to the following conditions: Internal exchanger water temperature = 12/7 C; External exchanger air temperature = 35 C (2) The sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refers to a distance of 1m from the external surface of the units operating in an open field. Measures according to UNI EN ISO 9614-2 regulations, with respect to the EUROVENT 8/1 certification. Data referred to the following conditions: Internal exchanger water = 12/7 C; Outdoor air temperature 35 C (3) Data calculated in compliance with Standard EN 14511:2011 referred to the following conditions: Internal exchanger water temperature = 40/45 C. External exchanger air temperature 7 D.B. /6 ( C) W.B. SC-EXC Compressors soundproofing (SC)-Excellence SC-PRM Compressors soundproofing (SC)-Premium SC Compressors soundproofing (SC) EN Extremely low noise (EN)

accessories 1PUS Standard pump 1PU1SB Standard pump with emergency pump 2PM Hydropack with 2 pumps IFWX Water steel mesh strainer A300 300-litre storage tank (sizes 352 602) A300RPS 300-litre storage tank with primary circuit onboard (sizes 352 602) A500 500-litre storage tank (sizes 702 802) A500RPS 500-litre storage tank with primary circuit onboard (sizes 702 802) ABU Flush hydraulic connections CCCA Copper / aluminium condenser coil with acrylic lining CCCA1 Copper / aluminium condenser coil with Energy Guard DCC Aluminum AMMX Spring antivibration mounts PGCCH Anti-hail protection grilles PGFC Finned coil protection grill PSX Mains power supply CONTA2 Energy meter RCMRX Remote control via microprocessor control CMSC8 Serial communication module to BACnet supervisor CMSC10 Serial communication module to LonWorks supervisor CMSC9 Serial communication module to MODBUS supervisor SCP4 Compensation of set point with signal 0-10 V SPC2 Set point compensation with outside temperature probe ECS ECOSHARE function for the automatic management of a group of units PFCP Power factor correction capacitors (cosfi > 0.9) Key to symbols and notes Accessories supplied separately. For compatibility between the various accessories, please refer to the dedicated Technical Bulletin or our website in the Systems and Products section. SFSTR Disposal for inrush current reduction MHP High and low pressure gauges AEG1 Antifreeze protection with 10% ethylene glycol AEG2 Antifreeze protection with 20% ethylene glycol AEG3 Antifreeze protection with 30% ethylene glycol AEG4 Antifreeze protection with 40% ethylene glycol AEG5 Antifreeze protection with 50% ethylene glycol WSAT-XEE only: CCCAG Copper / aluminium condenser coil with gray acrylic lining (sizes 802) MF2 Multi-function phase monitor DML Demand limit RE-20 Electrical panel antifreeze protection for min. outdoor temperature down to -20 C RE-25 Electrical panel antifreeze protection for min. outdoor temperature down to -25 C RE-30 Electrical panel antifreeze protection for min. outdoor temperature down to -30 C RE-35 Electrical panel antifreeze protection for min. outdoor temperature down to -35 C RE-39 Electrical panel antifreeze protection for min. outdoor temperature down to -39 C FANQE Electrical panel ventilation SDV Compressor discharge and suction shut-off valve WSAN-XEE only: PM Phase monitor OHE Limit extension kit in heating up to -10 C (W.B.)

Data contained in this document are not binding and may be changed by the Manufacturer without notice. www.clivet.it