Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Similar documents
Type Contact form Model

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Magnecraft Power Relays

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

02/11/2015

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

LoopBack Relay. SGLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Multifunction Digital Timer

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Magnetic and Hydraulic-Magnetic Circuit Breaker

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Solid-State Digital Timer

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Model Number Structure

Absolute Rotary Encoder E6CP

Fibre Optic Modem ODW-611

MAP110 AC-DC Series Data Sheet

MILLITARY SPECIFICATION SHEET

Series CT7N Bimetallic Overload Relays

Self--powered Time Counter

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Fibre Optic Modem ODW-622

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

LONWORKS Fibre Optic Converter

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

ODW-621. RS-232 Point-to-point applications

A V 50Hz / V 60Hz

LONWORKS Fibre Optic Router

Lighted Pushbutton Switch (Square) Ultra Bright LED Type

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Fibre optic router for TP/FT-10 LRW-112PP

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Self-powered Totalizer

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Photoelectric Sensors E3F2

Interface Relays and Optocouplers Product group picture

D-B relay - High DC breaking capacity, Datasheet

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

Self-powered Totalizer New H7E

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Indoor Linear 80W Driver SI-C215280N2KR

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Ordering Information. Self-Powered Tachometer H7ER. Subminiature Tachometers With Improved Appearance and Features. H Large display with 8.

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Limiter RLM Ω Broadband 950 to 2050 MHz. The Big Deal

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

10 SERIES. Light dependent relays A

Ordering details. Approval. Classification

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

ALLEN BRADLEY TIMING RELAY

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

AQ-H SOLID STATE RELAY FEATURES

Pluggable interface relays CR-M Miniature relays

ADE-R3GLH+ CONVERSION LOSS 50. ISOLATION (db) 10 LO= +7 dbm LO= +10 dbm LO=+13 dbm FREQUENCY (MHz) RF VSWR

Pluggable interface relays CR-M Miniature relays

Minicontactorrelay,2NO/2NC,DCoperated

Datasheet - SRB-E-201ST

Bimetal Temperature Switch

LW Series offer flexibility in space-saving package

relays Electromechanical 2006 /2007

AS09..S 3-pole Contactors - Spring Terminals

Engineering Design Assurance Test Report ( Dual & Triple ) MODEL: SPS-100P-D2 V1 5 V 12 Amax

Photoelectrics Through-beam Type PA18C.T..., DC

GR circuit breaker - hydraulic magnetic, Datasheet

DPS-250AB-18 E. 電氣規格 (Electrical Specification) REV. Description Date DESCRIPTION : MODEL NO. : Date Drawn Desing(EE) Design(ME) DOCUMENT NO. : REV.

DSM Series Ultra Thin Surface Mount Single Digit 7-Segment LED Display

Datasheet - SRB301LC 24VAC/DC

Type: DILM12 10(24VDC) Article No.:

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Weighing Meter. Ordering Information. Highly Functional Weighing Meter with Easy-to-read LED. Base Units

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Data Sheet Definite Purpose Contactors Ex9CK Series

Linear encoders without bearings incremental System for linear motion feedback

Transcription:

Low Signal Relay G6E Subminiature 7.87 H x.1 W x 16 L mm (0.31 H x 0.3 W x 0.63 L in). High sensitivity with pick-up coil power of 8 mw. Surge withstand meets FCC Part 68 rule and Telcordia 2.5 kv Specifications. Packaged for automatic insertion. Unique moving loop armature reduces relay size, magnetic interference, and contact bounce time. Bifurcated crossbar contact assures high reliability. Minimal loss of latching capability due to highly efficient magnetic circuit; also, highly resistant to shock and vibration. Sealed construction allows automatic solder and cleaning; assures high reliability even in adverse environments. RoHS Compliant. Ordering Information To Order: Select the part number and add the desired coil rating, (e.g., G6E-134P-ST-US-DC6). Non-latching Type Contact form Model Standard Low sensitivity PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US Latching Type Contact form Model Single coil latching Dual coil latching Standard Low sensitivity Standard Low sensitivity PCB SPDT G6EU-134P-ST-US -- G6EK-134P-ST-US G6EK-134PL-ST-US Specifications Contact Data Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.4) (L/R = 7 ms) load 0.40 A at 5 VAC, 2 A at 30 VDC 0.20 A at 5 VAC, 1 A at 30 VDC Contact material Ag (Au clad) Carry 3 A Max. operating 250 VAC, 220 VDC Max. operating 3 A (AC), 3 A (DC) 1.50 A (AC), 1.50 A (DC) Max. switching capacity 50 VA, 60 W 25 VA, 30 W Min. permissible load 10 µa, 10 mvdc Low Signal Relay G6E 1

Data Standard Non-latching Type (G6E-134P-ST-US) Low-sensitivity Non-latching Type (G6E-134PL-ST-US) Pick-up Dropout % of rated 3 66.70 45 0.08 0.06 70% max. 10% min. 10% max. Approx. 200 5 40 5 0.18 0.17 6 33.30 180 0.31 0. 22.20 405 0.62 0.50 720 1.20 0. 8.30 2,880 4.70 3.0 48 8.30 5,760 5.35 5. Approx. 400 Pick-up Dropout % of rated 3 133 22.50 0.03 0.03 70% max. 10% min. 10% max. 5 7.40 63 0.08 0.07 6 66.60 0 0. 0.10 44.30 33.30 203 360 1,440 0.21 0.45 1.77 0.1 0.42 1.65 Approx. 400 Standard Single Latching Type (G6EU-134P-ST-US) % of rated 3 66.70 45 0.05 0.04 70% max. 70% min. 10% max. 5 40 5 0.13 0. 6 33.30 180 0.1 0.17 22.20 8.30 405 720 2,880 0.45 0.84 3.56 0.40 0.7 3.10 130% max. Approx. 200 Note: 1. The rated and coil are measured at a coil temperature of 23 C with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23 C. Standard Dual Latching Type (G6EK-134P-ST-US) % of rated 3 66.70 45 0.05 0.04 70% max. 70% min. 10% max. 5 40 5 0.0 0.08 6 33.30 180 0. 0.11 7 22.20 8.30 405 720 2,880 0.25 0.44 1.66 0.22 0.41 1.62 130% max. Approx. 200 2 Low Signal Relay G6E

Low-sensitivity Dual Latching Type (G6EK-134PL-ST-US) % of rated 3 133 22.50 0.02 0.01 70% max. 70% min. 170% max. 5 7.40 63 0.04 0.03 6 66.60 0 0.06 0.04 44.30 33.30 203 360 1,440 0. 0.21 0.80 0.0 0.15 0.58 Approx. 400 Note: 1. The rated and coil are measured at a coil temperature of 23 C with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23 C. Characteristics Contact (initial) 50 mω max. Operate time (set time) 5 ms max. (mean value approx. 2.0 ms, 48 VDC type, approx. 2.40 ms) Release time (reset time) 5 ms max. (mean value approx. 1.30 ms) Bounce time Operate Approx. 3 ms (mean value 0.37 ms) Release Approx. 3 ms (mean value 1. ms) Operating frequency Mechanical 36,000 operations/hour Electrical 1,800 operations/hour (under rated load) Insulation 1,000 MΩ min. (at 500 VDC) Dielectric strength 1,500 VAC, 50/60 Hz for 1 minute between coil contacts 1,000 VAC, 50/60 Hz for 1 minute between contacts of same pole Surge withstand 1,500 V 10x160 µs (conforms to FCC Part 68) 2,500 V 2 x 10 µs (Telcordia Requirement) Vibration Mechanical durability 10 to 55 Hz; 5 mm (0.20 in) double amplitude Malfunction durability 10 to 55 Hz; 3.3 mm (0.13 in) double amplitude Shock Mechanical durability 1,000 m/s 2, approx. 100G Malfunction durability 300 m/x 2, approx. 30G Ambient temperature -40 C to 70 C (-40 F to 158 F) Humidity 10% to 85% RH Service life Mechanical 1 million operations min. (at 36,000 operations/hour) Electrical See Characteristic Data Weight Approx. 2.7 g (0.10 oz.) Note: Data shown are of initial value. Low Signal Relay G6E 3

Characteristic Data Switching CapacityElectrical Service Life M Ambient Temperature vs. maximum Voltage (reference only) Dimensions Unit: mm (inch) Non-latching G6E-134P-ST-US, G6E-134PL-ST-US Latching G6EU-134P-ST-US Note: 1. and indicate mounting orientation marks. 2. Pay attention to the polarity of the coil. 4 Low Signal Relay G6E

G6EK-134P-ST-US, G6EK-134PL-ST-US Note: 1. and indicate mounting orientation marks. 2. Pay attention to the polarity of the coil. Approvals UL (File No. E41515)/CSA (File No. LR3128) Type Contact form ratings Contact ratings G6E-134P-ST-US G6E-134PL-ST-US G6EU-134P-ST-US G6EK-134P-ST-US G6EK-134PL-ST-US SPDT 1.5 to 48 VDC 0.2 A, 250 VAC (General purpose) 0.6 A, 5 VAC (General purpose) 2 A, 30 VDC (Resistive) 0.6 A, 5 VDC (Resistive) Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA, TUV) may be different from the performance characteristics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change. 3. Complies with UL150 Basic Insulation at 5 V (pollution degree 1 for internal spacings, pollution degree 2 for external spacings). Hints on Correct Use Avoid ultrasonic cleaning at 28 khz, 13 mw/cm 3 for a period of more than 30 seconds. Single-winding type (G6EU) Example of low-power driver circuit 1. This is an example of a driver circuit that allows Model G6E to function as a normal relay with a normal switching pulse input. 2. The relay is set by an abrupt charged to capacity C. This flows in the relay via diode D 1 and C and out via diode D 2. 3. The relay is reset by the discharge of C flowing in the relay via transistor TR and C. Note: 1. Give adequate consideration to the circuit constant when actually using this circuit, confirming the set and reset status of the relay. 2. OMR owns the patent on this circuit. Consult OMR when using this circuit. Low Signal Relay G6E 5