VacTest. Vacuum Measurement Equipment The Best Choice to Monitor and Control Your Vacuum Process. Vacuum Measurement Technology by Busch

Similar documents
Intelligent Vacuum Metrology New VSR, VSP, VSM & VSH series

IONIVAC Transmitter ITR 90

HICUBE. The modular pumping stations for all applications in high and ultra-high vacuum

CENTERLINE. Total pressure gauges

Vacuum measurement and control units

PHOENIX Finds every leak. Now with an even fi ner nose.

Installation Instructions. What This Option Provides

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

TELEDYNE HASTINGS INSTRUMENTS

ITER Product Catalogue. Total Pressure Measurement V Page 1 / 15

DFT. Compact Paddle Flow Sensor

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

CombiSeries. Making temperature, pressure and conductivity measurement safe and convenient.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Bio-Rad Imaging Systems Family

A PASSION FOR PERFECTION. OktaLine. The Power Pump Portfolio. Roots Pumps for Every Low and Medium Vacuum Application.

DMP 331i / DMP 333i LMP 331 i

Agilent High Capacity RV Pumps & Roots Pumping Systems

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DFT. Rotating Vane Flow Meter, Counter, Doser. for liquids l/min. Measuring accuracy: 2.5% f. s. : 16 bar; t max

HiPace 300 with TC 110 and power supply OPS 100, DN 100 ISO-F

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

CORONA & PLASMA FOR NARROW WEB

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Model KBF 1020 Constant climate chambers with large temperature / humidity range

CORONA & PLASMA FOR NARROW WEB

ITER Product Catalog Total Pressure Measurement. ITER Product Catalogue Total Pressure Measurement V Page 1 / 15

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

NEW. Cable/Pipe sizes. InsertStrip. MainBlock

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Model KT 53 Cooling incubators with thermoelectric cooling

Scope of the art Scope Rider Handheld digital oscilloscope

Model KBF 115 Constant climate chambers with large temperature / humidity range

Separate Thin Amplifier type. AP-V40AW Series

Model KT 115 Cooling incubators with thermoelectric cooling

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

UNIGAS Hand-held combustion gas analyzer with 3 sensors

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

TA0311 TECHNICAL ARTICLE High Temperature Electronics 1 Introduction 2 Why the need for high-temperature semiconductors?

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

Troubleshooting Analog to Digital Converter Offset using a Mixed Signal Oscilloscope APPLICATION NOTE

Model KBF P 240 Humidity test chambers with ICH-compliant light source

World s smallest 5MP stand-alone vision system. Powerful Cognex vision tool library including new PatMax RedLine and JavaScript support

Keysight Technologies Multi-Channel Audio Test using the Keysight U8903A Audio Analyzer

Arc-fault Protection System

Compact and powerful. The small chamber machines by MULTIVAC.

Dry Compressing Vacuum Pumps. Dry Com. CLAWVAC Claw Vacuum and Overpressure Pumps

X-RAY 6000/6000 PRO. Diameter/wall thickness/concentricity measuring system for insulating and sheathing lines.

Description. Table 1. Device summary. Order codes Temperature range [ C] Package Packing. LPS2HBTR -30 to +105 HLGA - 10L

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope APPLICATION NOTE

IMPAC Infrared Thermometers

Interconnections. General characteristics. Plug

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Thermo Scientific Polar Series Cooling/Heating Recirculating Chillers

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

CIRCOGRAPH. Non-Destructive Eddy Current Testing of Long Products such as Wires, Bars and Tubes

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Global pay TV revenues crawl to $200 billion

PENNINGVAC Transmitter PTR 90 N

ROTARY EVAPORATOR BOECO ROTARY EVAPORATOR RVO 400 SD

SignalCorrect Software and TCS70902 Calibration Source Option SC SignalCorrect software

Electrical Sampling Modules Datasheet 80E11 80E11X1 80E10B 80E09B 80E08B 80E07B 80E04 80E03 80E03-NV

Arc Detecting and Protection System

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

THE ULTIMATE DRY CHOICE

Model KT 170 Cooling incubators with thermoelectric cooling

Electromagnetic Block Valves Direct Acting

ACP 15 / 28 / 40 SERIES 2 COMPACT DRY ROUGHING PUMPS

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Agilent Understanding the Agilent 34405A DMM Operation Application Note

Agilent 87405C 100 MHz to 18 GHz Preamplifier

CTC Series. Compact Temperature Calibrator

Magnetic Stirrers Magnetic Stirr

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Pressure Sensors SPAB, with Display

C-28 PLUS C-28 C-22 PLUS C-22 C-17 PLUS C-17 Premium sterilisation

BFI RESEARCH AND STATISTICS PUBLISHED AUGUST 2016 THE UK FILM MARKET AS A WHOLE. Image: Mr Holmes courtesy of eone Films

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

Speed sensor MiniCoder GEL 2471

Model KBF 720 Constant climate chambers with large temperature / humidity range

The Great Transition: Shifting from Fossil Fuels to Solar and Wind Energy Supporting Data - Climate

Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

5 Series MSO Serial Triggering and Analysis Applications 5-SRAUDIO, 5-SRAUTO, 5-SRCOMP, and 5-SREMBD Datasheet Serial triggering

Coverage where you need it, made easy!

OVZ. Economical Oval-Gear Flow Meter. For Viscous Oils

Keysight Technologies ad Integrated RF Test Solution

A3H series. Energy and cost efficient solutions for the most demanding applications. Multi-stage. Roots pumps

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

TUC: Universal thermostat

IMPAC Infrared Thermometers

Explorer Edition FUZZY LOGIC DEVELOPMENT TOOL FOR ST6

In the tube collection there are several sensors designed for applications in some kinds of physics measurements or detection.

Transcription:

VacTest Vacuum Measurement Equipment The Best Choice to Monitor and Control Your Vacuum Process Vacuum Measurement Technology by Busch

VacTest The Perfect Alliance Between Accuracy and Robustness Sophisticated full measurement range (1600 to 5 10-10 mbar), state-of-the-art micro-controller technology Reliable high industrial standards, robust construction, insensitive against shock venting Efficient modular design, plug and play sensor for maximum uptime Busch VacTest is the new shape of vacuum measurement equipment. Designed to combine the latest advances in vacuum metrology with exceptional manufacturing quality, it provides an innovative and comprehensive portfolio of active vacuum gauges and controllers. Robust construction, reliability and measurement accuracy are key features of these devices, making them the ideal choice to monitor and control your vacuum process, whether it is in industry or research. Several state-of-the-art technologies allow a wide measurement range from 1600 to 5 10-10 mbar covering all vacuum levels with accuracy. All sensors comply with international standards and regulations such as CE and RoHS. Corresponding to our extensive portfolio of vacuum pumps, blowers and compressors, we offer the right measurement technology for every process. Three product lines tailored to your needs With three product lines available, Busch VacTest ensures meeting accuracy, measurement range and functional requirements of your vacuum system or process: VacTest Digital Transmitters are high-end gauges coming with a full range of options as standard. Their smart micro-controller architecture allows an optimal sensor control as well as many setting possibilities making them the ideal solution for many applications. VacTest Analog Transmitters feature a compact, rugged and functional design. Thanks to their excellent measurement accuracy and stability, these transmitters are ideal for centralized monitoring and control systems. VacTest Mobile Gauges are the perfect handheld solution for service or vacuum process quality assurance. These batteryoperated gauges offer various functions such as an USB interface for data export and visualization, a data logger and can even be used under vacuum.

Product Overview VacTest Vacuum Measurement Equipment DTP VacTest DTP / DPP 400 * Digital transmitter, Pirani 1000 1 10-4 mbar DPH VacTest DPH 400 * Digital transmitter, Pirani & Hot cathode 1000 5 10-10 mbar DCC VacTest DCC / DPC 400 * Digital transmitter, Cold cathode 2 10-3 5 10-9 mbar DTP DPP Digital transmitter, Pirani Pt / Rh 1000 5 10-4 mbar Digital transmitter, Piezoresistive & Pirani 1200 1 10-4 mbar DPC Digital transmitter, Pirani & Cold cathode 1000 5 10-9 mbar GRP VacTest GRP / GTP 100 Analog transmitter 0 10 V, Piezoresistive 1400 1 mbar GRP VacTest GRP / GTP / GCD 200 Analog transmitter 4 20 ma, Piezoresistive 1400 1 mbar TRP VacTest TRP / TTP / TPP 900 Mobile gauge, Piezoresistive 1600 1 mbar GTP Analog transmitter 0 10 V, Pirani 1000 1 10-4 mbar GTP Analog transmitter 4 20 ma, Pirani 1000 1 10-4 mbar TTP Mobile gauge, Pirani 100 1 10-3 mbar GTP Analog transmitter 0 10 V, Pirani Pt / Rh 1000 5 10-4 mbar GCD Analog transmitter 4 20 ma, Capacitive 200 0.1 mbar TPP Mobile gauge, Piezoresistive & Pirani 1200 5 10-4 mbar * versions with and without display available VacTest the right measurement equipment to monitor and control every vacuum process.

Measurement Principles Tailored to Your Needs For Each Application the Right Technology Accurate pressure measurement is key factor in many vacuum-assisted production processes to ensure optimum efficiency and high product quality. Several sensor technologies are available to measure with accuracy all 14 decades of vacuum. They can be divided into two main categories: direct and indirect pressure measurement. The direct measurement principle is independent of the process gas and based on the force exerted by the molecule flow on a diaphragm. This method is mainly used for rough and medium vacuum processes. As the pressure decreases, the number of gas molecules becomes too small to be properly detected by the sensor. At a higher vacuum level, indirect measurement principles are used, based on special properties of the process gas, such as thermal conductivity or ionization probability. In opposite to the direct measurement method, those principles are dependent on the nature of the process gas, and therefore a specific correction factor has to be applied for each process gas different than air or nitrogen. Direct Pressure Measurement (Gas Type Independent) Piezoresistive sensor The robust and cost-effective Piezoresistive sensor technology measures the change in resistance of a strain gauge resulting from the diaphragm deflection. Its robustness and versatility make it the best choice for an absolute pressure measurement in the rough vacuum range. Measurement range: 1600 to 1 mbar Excellent measurement accuracy Chemically resistant ceramic sensor Short response time High reliability Long term stability Capacitive sensor High resolution and accurate capacitive sensors measure the change in electrical capacitance of a plate condenser induced by the diaphragm deflection. These sensors have been specially designed for industrial applications where high accuracy and chemical compatibility are required. Measurement range: 200 to 0.1 mbar Excellent measurement accuracy Chemically resistant ceramic sensor High reliability Temperature compensated Industrial metal design High protection class Proper sensor selection There are several important considerations when selecting a vacuum sensor. Knowing the pressure range, required accuracy, gas composition, process and environmental conditions is crucial to achieve optimum measurement results. Your local Busch representative can assist you with this decision and help you make the right choice for your vacuum system. Rough vacuum Medium vacuum High vacuum Ultra high vacuum 1000 100 10 1 10-1 10-2 10-3 10-4 10-5 10-6 10-7 10-8 10-9 10-10 hpa (mbar) Piezoresistive Capacitive diaphragm Piezoresistive Pirani combination Pirani Cold cathode (inverted magnetron) Pirani Cold cathode (inverted magnetron) combination Pirani Hot cathode (Bayard-Alpert) combination

Indirect Pressure Measurement (Gas Type Dependent) Pirani The robust and reliable Pirani technology measures the thermal conductivity of gases. The heat transfer between a heated filament and its surrounding environment will change in proportion to the pressure. Pirani sensors are the best solution for medium vacuum applications. Cold cathode Cost-effective and robust cold cathodes (inverted magnetron) measure the electrical conductivity of a plasma. Neutral gas molecules are ionized through collision with electrons and collected by the cathode. The generated current is an indication of the pressure in high and ultra high vacuum processes. Hot cathode Stable and reproducible hot cathodes after the Bayard-Alpert principle measure the gas ionization via thermal electron emission. The ion collector current is linearly related to the gas pressure. This technology is one of the most accurate measurement principles for high and ultra high vacuum. Wide measurement range from 1000 to 1 10-4 mbar Optional combination with a Piezoresistive sensor to increase accuracy when measuring high pressures Spiral coil filament for better accuracy and durability Superior stability through individual temperature compensation Excellent resistance to contamination Optional Pt / Rh filament for corrosive applications Combination with a Pirani sensor for an extended measurement range: 1000 to 5 10-9 mbar Low measurement uncertainty: < 25% for high vacuum Automatic power-on and power-off to extend sensor life Fast ignition even at high vacuum Low magnetic stray field Automatic adjustment of Pirani zero pressure during operation Combination with a Pirani sensor for an extended measurement range: 1000 to 5 10-10 mbar Excellent measurement accuracy: < 10% uncertainty below 10 mbar Enhanced lifetime due to double filament Automatic power-on and power-off to extend sensor life Automatic adjustment of Pirani zero pressure during operation Tested with > 100000 shock venting cycles Matching sensors for Busch vacuum pumps R 5 Mink COBRA Panda / Puma Seco Huckepack Dolphin Zebra Fossa Turbo Rangu Piezoresistive Capacitive diaphragm Piezoresistive Pirani combination Pirani Cold cathode Pirani Cold cathode combination Pirani Hot cathode combination

Technical Features Digital Transmitters 1 2 High performance Outstanding features as standard Extended measurement range 1200 5 10-10 mbar Excellent measurement accuracy and reliability Digital micro-controller intelligence Two integrated setpoints as standard Bake-out temperature up to 180 C without electronics removal Robustness and durability Developed for industrial applications Robust sensors, insensitive against shock venting and vibration Metal-sealed for ultra low leakage rate < 5 10-10 mbar l/s IP40 or optional IP54 Overpressure limit up to 10 bar 3 3 4 5 Application-oriented Maximum flexibility RS485 interface and 0 10 V output signal Integrated and highly visible display (option) Compatible with competitors gauges customizable output signal Individual gauge power supply without controller possible Complete control Individual configuration Measurement value at a glance due to external controller Customizable gauge configuration via PLC or PC Wireless connection via Bluetooth module Configuration and data management via VacTest explorer software Easy servicing Plug and play replacement sensor On-site exchange, can be done by the user No special tools required Sensor is interchangeable without calibration Replacement sensors automatically take all parameters 2

4 1 5

Technical Features Analog Transmitters 1 2 3 Leading-edge technology Accurate measurement results Wide measurement range 1400 1 10-4 mbar covering the whole rough and medium vacuum range Excellent measurement accuracy Superior measurement stability through individual temperature compensation Reliability and safety In line with industrial requirements Robust stainless steel housing Resistant against shock venting and vibration Reliable in sophisticated applications Metal-sealed for ultra low leakage rate < 5 10-10 mbar l/s Industrial standard IP54 (4 20 ma models) and IP40 (0 10 V models) Flexible scope Perfectly adaptable to every process Very compact industrial design Flexible analog output signal (0 10 V or 4 20 ma depending on model) Zero adjustment by digital push button Compatible with external controller 2 3 1

Technical Features Mobile Gauges 1 2 3 Excellent accuracy Long-term measurement Wide measurement range 1600 5 10-4 mbar Excellent measurement accuracy up to 0.3% full scale Up to 2500 hours of battery life Compact and portable Unique handheld gauge series Very compact and light vacuum gauge as hand unit Detachable, external Pirani sensor with long life spiral coil filament (TTP 900) Reliable in sophisticated applications Can be used inside a vacuum chamber Optional interfaces Data logger and memory function USB interface for data export and visualization Online reading via USB to PC Easy data export and management via VacTest explorer software Data logger for up to 2000 measurements Min. and max. memory functions 3 4 Maintenance-oriented Quick vacuum test Designed for easy maintenance inspection of vacuum installations Pumping speed and leakage rate function via pressure down or rise method 1 2 4

VacTest explorer and VacTest viewer The Indispensable Software Tools VacTest explorer The advanced VacTest explorer is the indispensable software tool on computers and tablets to visualize, analyze and compare process data in a quick and efficient way. Available in Lite and Pro versions, VacTest explorer has numerous functionalities such as calculation of leakage rates, remote control of Active Sensor Controllers, pumpdown curves comparison, configuration of all Digital Transmitter parameters, etc. VacTest viewer VacTest viewer is a free Bluetooth sniffer application for mobile devices with Android operating system used to display the pressure value of up to 16 connected sensors. Designed for Bluetooth data exchange between software and sensor, it is a perfect tool for maintenance or calibration purposes. Visual and acoustic warnings can be programmed to report a maximum or minimum pressure value. Software download VacTest explorer software for Windows can be downloaded free of charge from our website. The Android version for tablets and VacTest viewer are also available. A license is needed to activate all advanced functionalities of the Pro version. Please contact your closest Busch representative to obtain a license. www.buschvacuum.com/vactest State-of-the-art software Software for visualization and documentation Monitoring and analyzing tool Data logging and data export to Microsoft Office Pre-programmed parameters for selected gases, such as He, H 2, N 2 and others Multi-language selection Adjustment of gauge settings VacTest explorer VacTest viewer

Controllers, Accessories and Spare Parts VacTest Vacuum Measurement Equipment Active Sensor Controllers With the Active Sensor Controllers you have all measurement values at a glance. Two compact control units are available for simultaneous operation with two or four vacuum sensors. Used either as table top or as rack mount, they feature large LCD displays with background illumination, several relay contacts as well as both USB and RS232 interfaces. The CTR 002 and CTR 004 allow full control and configurations of the sensors thanks to an intuitive navigation. Parameters such as gas type correction factor, pressure units, setpoints and other beneficial functions are easily adjustable. Gauge connection A full range of connecting cables as well as exclusive options like our Bluetooth module for Digital Transmitters are available to facilitate gauge integration. Gauge protection In order to increase the lifetime of the gauges and guarantee measurement accuracy, it is important to protect them against contamination. Therefore, the installation of a protection between sensor and vacuum system is highly recommended. Busch provides baffles, wire filters and spiral tubes to ensure safe operation of your measurement equipment. Spare sensor heads Spare sensor heads are available for all Digital Transmitters. The plug and play ability keeps calibration and setting parameters, thereby ensuring fast sensor replacement without impacting the process. Fittings Busch also offers high quality fittings, such as clamps, centering rings, adapters, etc. to install your measurement equipment. Bluetooth module Connecting cables Baffles Wire filters Spiral tubes and many more

Technical Data VacTest Vacuum Measurement Equipment Mobile Gauges Digital Transmitters TRP 900 TTP 900 TPP 900 DTP 400 DTP 400 C Measurement principle Piezoresistive Pirani Piezoresistive and Pirani Pirani Pirani for corrosive applications Measurement range (mbar) 1600 1 100 1 10-3 1200 5 10-4 1000 1 10-4 1000 5 10-4 Measurement uncertainty ± 0.3% f.s. 100 20 mbar ± 30% rd 20 1 10-2 mbar ± 10% rd < 1 10-2 mbar ± factor 2 1200 40 mbar ± 0.3% f.s. 40 2 10-3 mbar ± 10% rd < 2 10-3 mbar ± factor 2 1000 20 mbar ± 30% rd 20 2 10-3 mbar ± 10% rd < 2 10-3 mbar ± factor 2 1000 10 mbar ± 30% rd 10 1 10-2 mbar ± 10% rd < 1 10-2 mbar ± factor 2 Vacuum connection DN 16 ISO-KF, G¼ female thread DN 16 ISO-KF DN 16 ISO-KF Display yes optional Overpressure limit (abs) 4 bar 2 bar 10 bar Bake-out temperature (at the flange) - 150 C Protection class IP40 IP40, optional IP54 Electrical connection jack for external power supply D-Sub 15 poles Output signal USB 0 10 V, RS485 Serial interface USB RS485 Connection to computer via mini USB via USB interface or Bluetooth with optional adapter Data logging function yes yes, via VacTest explorer software Setpoint relay - 2 dry contacts Controller - CTR 002: 2 channels CTR 004: 4 channels

Analog Transmitters DPP 400 DCC 400 DPC 400 DPH 400 GTP 100 / 200 GTP 100 C GRP 100 / 200 GCD 200 Piezoresistive and Pirani Cold cathode Pirani and Cold cathode Pirani and Hot cathode Pirani Pirani for corrosive applications Piezoresistive Capacitive 1200 1 10-4 2 10-3 5 10-9 1000 5 10-9 1000 5 10-10 1000 1 10-4 1000 5 10-4 1400 1 200 0.1 1200 40 mbar ± 0.3% f.s. 40 2 10-3 mbar ± 10% rd 2 10-3 1 10-8 mbar ± 25% rd 1000 10 mbar ± 30% rd 10 2 10-3 mbar ± 10% rd 2 10-3 1 10-8 mbar ± 25% rd 1000 10 mbar ± 30% rd 10 1 10-8 mbar ± 10% rd 1000 20 mbar ± 30% rd 20 2 10-3 mbar ± 10% rd < 2 10-3 mbar ± factor 2 1000 10 mbar ± 30% rd 10 1 10-2 mbar ± 10% rd < 1 10-2 mbar ± factor 2 ± 0.3% f.s. ± 0.25% f.s. DN 16 ISO-KF DN 25 ISO-KF or DN 40 ISO-KF DN 25 ISO-KF, DN 40 ISO-KF or DN 40 CF-F DN 16 ISO-KF DN 16 ISO-KF, G¼ female thread optional no 4 bar 10 bar 4 bar 10 bar 4 bar 6 bar 150 C 160 C 180 C 150 C - - IP40, optional IP54 100: IP40 200: IP54 IP40 100: IP40 200: IP54 IP54 D-Sub 15 poles GTP 100: Hirschmann, 6 poles GTP 200: M12 A, 5 poles Hirschmann, 6 poles GRP 100: Hirschmann, 6 poles GRP 200: M12 A, 5 poles M12 A, 5 poles 0 10 V, RS485 100: 0 10 V 200: 4 20 ma 0 10 V 100: 0 10 V 200: 4 20 ma 4 20 ma RS485 - via USB interface or Bluetooth with optional adapter via controller CTR 002 for 0 10 V sensors - yes, via VacTest explorer software no 2 dry contacts - CTR 002: 2 channels CTR 004: 4 channels CTR 002: 2 channels, only for 0 10 V sensors - f.s. = full scale rd = of reading

Applications VacTest Vacuum Measurement Equipment Mobile Gauges Digital Transmitters TRP / TTP / TPP 900 DTP Pirani DPP Piezo / Pirani DCC / DPC Cold cathode, Pirani / Cold cathode DPH Pirani / Hot cathode Process industry R&D Analytical instruments Industrial leak detection High vacuum pump systems Coating (PVD & CVD) Semiconductor and flat panel Solar Automotive industry Vacuum insulation Metallurgy / Heat treatment Vacuum furnace Chemical and pharmaceutical Plastics industry Vacuum drying Freeze drying Food industry Vacuum packaging Medical Central vacuum system Pneumatic conveying Service and maintenance

Analog Transmitters Selecting the Right Measurement Equipment GRP Piezo GTP Pirani GCD Capacitive Each vacuum application has its specific characteristics. Therefore, the table to the left provides just a general overview of the appropriate sensor technology for certain vacuum processes. Ask your local Busch representative to assist you in selecting the right technology. With our Vacuum Consulting and VacuumAudit services, we also advise you when outlining a vacuum-assisted production process or when attempting to optimize the performance of an existing process. We are happy to assist you. Contact us. To learn more about our Vacuum Consulting and VacuumAudit services, visit our website: www.buschvacuum.com/vacuum-consulting

Busch Vacuum Pumps and Systems All Over the World in Industry Argentina www.busch.com.ar Denmark www.busch.dk Malaysia www.busch.com.my South Africa www.busch.co.za Australia www.busch.com.au Finland www.busch.fi Mexico www.busch.com.mx Spain www.buschiberica.es Austria www.busch.at France www.busch.fr Netherlands www.busch.nl Sweden www.busch.se Bangladesh www.busch.com.bd Germany www.busch.de New Zealand www.busch.co.nz Switzerland www.busch.ch Belgium www.busch.be Hungary www.buschvacuum.hu Norway www.busch.no Taiwan www.busch.com.tw Brazil www.buschdobrasil.com.br India www.buschindia.com Peru www.busch.com.pe Thailand www.busch.co.th Canada www.busch.ca Ireland www.busch.ie Poland www.busch.com.pl Turkey www.buschvacuum.com/tr Chile www.busch.cl Israel www.busch.co.il Portugal www.busch.pt United Arab Emirates www.busch.ae China www.busch-china.com Italy www.busch.it Romania www.buschromania.ro United Kingdom www.busch.co.uk Colombia www.buschvacuum.co Japan www.busch.co.jp Russia www.busch.ru USA www.buschusa.com Czech Republic www.buschvacuum.cz Korea www.busch.co.kr Singapore www.busch.com.sg Do you want to know more? Contact us! www.buschvacuum.com Technical data is subject to change. Created in Germany. MG STB VACTEST Len 10/2018 8Ca