Multi Channel Programmable Filter-Equalizer. Use Manual. Digital. Terrestrial. Ref. : 6505

Similar documents
UK. Multi Channel Programmable Filter-Equalizer. User Manual FEATURES. - Designed for both digital and analogue channels,

Multi Channel Programmable Filter-Amplifier. User Manual I-II III V-U SAT. Stop Channel SAT Slope Start Channel SAT ON / OFF.

User Manual. dcss/dscr Multiswitch 9732

User Manual. SCR Multiswitch Ref. 9744SKY, 9746SKY, 9748SKY

User Manual. HDMI Modulator Ref & SW Release

User Manual. Profiler Revolution Ref PATENT PENDING. SW Version 1.3.0

User Manual. dcss/dscr Multiswitch 9733PL 9734PL

DMOD1200MS. HDMI Modulator. User Manual PLEASE READ THE MANUAL COMPLETELY BEFORE USE V.17.09

Multi channel programmable Filter-Amplifier

user manual Colosseum 8500D

ATS50SAW Programmable Selective Amplifier

HDMI 1-in 1-out Extender via CAT-5e/ CAT-6

AT450SAW Programmable Selective Amplifier

AT47SAW Programmable Selective Amplifier

Operating Instructions

Single cable multiswich programmer PC102W

MAX T200 HD QUICK INSTALLATION GUIDE

User Manual. UNIVERSE Ref. 8600

Bring High-Definition to your life!

Operating Instructions

User Manual CS-HDBTLPOER m HDBaseT Extender with Bi-directional PoE. Version: V1.0.0

HDTV Supply Inc. reserves the right to make changes in the hardware, packaging and any accompanying documentation without prior written

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

User Manual. UNIVERSE Ref. 8600

USER MANUAL DUX-TX DUX-RX HDMI EXTENDER

Grandbeing. HDMI Splitter(Asynchronous Switching Method) Operating Instructions(P/N of this Instructions is INSGB07SW0102)

LINK EXT40-4KUHD 4:4:4 HDR HDBaseT Extender. User Manual. Version: V1.0.1

Operating Instructions

User s manual OLY 9X K OLY 9X OLY 9V. User s Guide. Headend cascade multiswitch OLY 9X K Cascade multiswitch OLY 9X. Cascade line amplifier OLY 9V

User guide. Stand alone Multiswitches SMC Cascadable Multiswitches SMU Amplifiers. Multiswitches

Bring High-Definition to your life!

Grandbeing. HDMI Splitter. Operating Instructions(P/N of this Instructions is INSSP )

2.0 Wall Mount TV Soundbar Instruction Manual

ZVOX AccuVoice TV Speaker Model AV203

HDBaseT Extender Over Single Cat5e/6 cable

ZVOX AccuVoice TV Speaker Model AV203

FD Trinitron Colour Television

Utility Amplifier GA6A Model

Grandbeing. HDMI Converter. Operating Instructions(P/N of this Instructions is INSSH S) FEATURES

HDMI Converter. Operating Instructions(P/N of this Instructions is INSYH0101)

Grandbeing. HDMI Splitter. Operating Instructions(P/N of this Instructions is INSSP0108)

Operating Instructions

28 4K LED monitor. User Manual M284K

SAT IF distribution system

Grandbeing. HDMI Matrix (Router Type) Features

Operating Instructions

MX-DIGITAL COAXIAL CONVERTER MX-1226

Grandbeing. HDMI Extender (By CAT-5E/6 cable) Operating Instructions(P/N of this Instructions is INSEX0101-U30/U31) FEATURES

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

Evolution Digital HD Set-Top Box Important Safety Instructions

Grandbeing. HDMI Matrix. Operating Instructions(P/N of this Instructions is INSMX0404-HH1) FEATURES

SquareLED - Aura Bar & Matrix Beam Light 100

HDTV Supply. Mega Scaler. Operating Instructions FEATURES

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

V/L V/H H/L H/H. Satellite - Input. Programmable Cascadable switch. with 32 User Bands with Terrestrial input & 1 Legacy port

HD Digital Set-Top Box Quick Start Guide

User Manual. UNIVERSE Ref SW Release

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Grandbeing. HDMI Convertor. Operating Instructions(P/N of this Instructions is INSMS A) FEATURES

DM-1CH SD DVB-T MODULATOR INSTRUCTION MANUAL

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

Applications & Features of the SB- SDQM- 2130

NS-3 RF Noise Source Operation Manual

XO-231 USER S MANUAL. Crossover ENGLISH

OWNER'S MANUAL MODEL: DTV-2000 STANDBY/ON

Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16)

IMPORTANT SAFETY INSTRUCTIONS

4KEX70-L. HDBase-T Lite Extender. User Manual

HD Digital MPEG2 Encoder / QAM Modulator

Installation Manual VIP 1003

beyond your expectations

1812R Blues King 12. User Manual

TS2.8 Sub OWNER S MANUAL

Technical Specifications

PH-1. Italian MM & MC Phono Preamplifier OWNER S MANUAL

User Manual High Definition Digital Set Top Box DVBT9070 Please read this User Manual carefully to ensure proper use of this product and keep this man

User Manual of digital Set Top Box PAT1 02

PLAYMATE PROFESSIONAL STEREO 19 MIXER, USB/SD CARD AND BLUETOOTH PLAYER. User Guide and Reference Manual. page 1

Q-TV2. User Manual. for Screens

TFT-LCD TV USER MANUAL W102T READ CAREFULLY BEFORE OPERATION W102T

OWNER S MANUAL HD-2CAT-1080P-130. Binary 2CAT Extender WELCOME TO THE BINARY BRAND OF PRODUCTS

2.4 GHz WIRELESS VIDEO SENDER SYSTEM MODEL: VS6234

PNP300 / PNP300UN / PNP350

Register your product and get support at SDV5122/27. EN User manual

ZVOX AccuVoice TV Speaker MODEL AV150.

LED TV MODEL NO.: NE22K5BG. Please read this manual carefully before installing and operating the TV. Keep this manual handy for further reference

Charlie Foxtrot Features include:

User Manual PROHDMI STREAMER/MODULATOR. Ref /

User Manual. High Definition Digital Set Top Box HDSTB250

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

Table of Contents. 1. Safety Use. 2. General Description. 3. Connection Diagram. 4. Operations and Management. 4.1 Display Status. 4.

Fusion 120 Zoom. User Manual. Order code: EQLED068


27'' Full HD LED Monitor KALED27MONSC Quick Start Guide

User manual Transmodulators. Ref. 5103S/5103T/5103Q/5130

Transcription:

R Ref. : 60 Multi Channel Programmable Filter-Equalizer Use Manual 1 2 3 4 6 7 8 9 GND Terrestrial MULTI CHANNEL PROGRAMMABLE FILTER-EQUALIZER Terrestrial Ref. : 60 32 R UHF +V /00 ma FEATURES - Designed for both digital and analogue channels, - 1 input / 1 output and 2 UHF input / 1 output, - 1 and 9 UHF programmable clusters, - Easy programming by using one rotary / push button viewed on 2 digits display and LEDs for each cluster, - 40 presets of configuration (see list in annex), - Accurate equalization of levels using 1 db step attenuators, - Switchable input amplifier to attenuate high input signals, - Selectable power pass on each input.

SAFETY INSTRUCTIONS Read carefully these instructions before connecting the unit. The operating voltage is indicated on the adapter. To prevent fire, short circuit, shock hazard: Do not expose the unit to rain or moisture. Install the unit in a dry location without infiltration or condensation of water. Do not expose it to dripping or splashing. Do not place objects filled with liquids, such as vases, on the apparatus. If any liquid should accidentally fall into the cabinet, disconnect the power plug. Refer to qualified technician before it's further operation. To avoid any risk of overheating: Install the unit in a well aery location and keep a minimum distance of 1 cm around the apparatus for sufficient ventilation. Do not place any items such as newspapers, table-cloths, curtains... on the unit that might cover the ventilation holes. The unit must not be exposed to any source of heat (sun, heater,...). Do not place any naked flame sources, such as lighted candles, on the apparatus. Do not install the product in a dusty place. Pull out power plug to make the different connections of cables. To avoid electrical shock, do not open the housing of adapter. Cleaning : Only use a dry soft cloth to clean the cabinet. Do not use solvent. Servicing : For repairing and servicing refer to qualified personnel. MOUNTING Grounding WARNING! Use only supplied power adapter. A different voltage and/or wrong polarity destroys the equalizer beyond repair! MULTI CHANNEL PROGRAMMABLE FILTER-EQUALIZER Terrestrial Ref. : 60 32 1 2 3 4 6 7 8 9 R GND UHF 98 mm. +V /00 ma 177 mm. 2

WARNING! Live parts inside 10 db 30 db 20 db 40 db 30 db 0 db DESCRIPTION (BIII) Grounding LED for Clusters 1 2 3 4 6 7 8 9 GND Mode / Function LED Power pass switch +V /00 ma + MULTI CHANNEL PROGRAMMABLE FILTER-EQUALIZER Terrestrial Ref. : 60 32 R UHF D C Power pass switch +V Mains 230-240 V~ 2 digits display Rotary/push button B I / B II cc cc Headend amplifier B I-II B III UHF +24V 772 Multiband Amplifier Test -30 db Output Terr est rial 3

OPERATION All parameters are set with the rotary push button. Each function and parameters are shown on 2 digits display and different LEDs. Programming - Make all the necessary connections and connect the equalizer to mains. The software version is displayed, followed by a dot. - Push on the rotary button for more than 3 seconds to enter into programming mode. 3sec. - Turn the button to select the desired mode. Mode is indicated with a GREEN colored LED. = green LED = red LED The LED is now RED colored. - Inside the mode, turn the button to select the parameter (input, cluster, channels, level...) 1 2 3 4 6 7 8 9 Cluster LEDs Display - Push the button to confirm the parameter setting. LED returns to a GREEN color. Repeat this section to set all parameters The equalizer will go in "stand-by" and will display a dot after 1 minute if the rotary / push button is not activated. 4

PRESETS - The filter-equalizer has 40 presets. See the list of presets in annex. To recall a preset Example : preset n 17 - Turn the button to select. - Inside the mode, turn the button to select the desired preset number. Display Notes: In the preset mode "01 to 40" the channels are "fixed". The level adjustments, the input amplifier and configuration of input can be modified. The "00" configuration allows to set all parameters. Display

CLUSTER PROGRAMMING Setting clusters per input - The filter-equalizer has 2 UHF input which are splitted over 9 clusters and 1 input for 1 cluster. There are three possible configurations: Input Number of cluster(s) 9 6 0 3 4 UHF 1 clusters are indicated by the RED LEDs n 1 to 9. UHF 2 clusters are indicated by the GREEN LEDs n 6 to 9. To select the number of UHF clusters: Select position n 00 to have access to the settings See "Presets" on page. - Turn the button to select. - Turn the button to set one configuration. Display of selected configuration : cluster indication cluster indication 1 2 3 4 6 7 8 9 Input Number of clusters Display "9.0" "6.3" ".4" 9 6 0 3 4 cluster indication Note: Each non used cluster has to be switched off (park function). Set the cluster to channel 00 (see "Setting channels / cluster"). 6

Setting channels / cluster Each UHF cluster has a bandwidth which can be programmed from 1 to 2 channels. Each cluster has one channel bandwidth. To set the channel(s) per cluster : In the following example cluster 1 is set for channel 22 to channel 23. - Turn the button to select the mode. Mode is indicated with a GREEN coloered LED = GREEN LED = RED LED - Inside the mode, turn the button to select the cluster to be set. LED n 1 1 2 3 4 6 7 8 9 - Turn the button to select the mode. - Turn the button to select the start channel Display - Turn the button to select the mode. - Turn the button to select the stop channel Display Repeat this section to set all clusters 7

Notes: - cluster: the display shows L to L10 for the standard "L" channels and 0 to 12 for the "B/G" standard channels. - Single channel mode: when the Channel () is selected, the Channel ( ) is automatically set at the same value. - Park function: To switch off a cluster, select and set the value to 00. The value is automatically set to 00. - If there are overlapping clusters, the display dots will blink alternately. Cluster 1 Cluster 2 Ch. 24-2 Ch. 2-26 Channel To check the channel settings of each cluster: - Turn the button to select. - Puch the rotary button to enter the selected mode. - Turn the button to choose the cluster to be checked. - The disoplay shows the channels which have been set. Examples Exemples are: : 1 2 3 4 6 7 8 9 Cluster is parked Cluster is set to channel 22 Blinking 22 and 23: cluster is set from 22 to 23. - Push the button to exit. 8

LEVEL ADJUSTMENT setting To set the level. - Select the desired cluster. Example : setting the level of cluster 2 - Turn the button to select the mode. - Turn the button to select cluster 2. 1 2 3 4 6 7 8 9 LED is acitvated - Turn the button to select the mode. - Turn the button to set the level, variable from 30 db to 0 db. Note: '30' is for maximum gain. '18' indicates 12 db attenuator. Repeat this section to set all levels 9

Each UHF input has a 20 db switchable amplifier. This is used as aditional 20 db attenuator for high levels up to 9 dbµv. 10 db on input for signals up to 8 dbµv. Input Amplifier To switch off the input amplifier. - Select the input to be attenuated. - Turn the button to select the mode. Filter & Input selection Filter & Input selection - Turn the button to select the input. UHF 1 1 2 3 4 6 7 8 9 UHF 2 All LEDs of selected input are activated Filter & Input selection - Turn the button to select the mode. La LED est VERTE La LED est à présent ROUGE - Turn the button to switch off the input amplifier. In 'OFF' position the input signal is 20 db attenuated in UHF and 10 db in. La LED est VERTE 10

R R GENERAL RESET This function reset the unit to default factory settings. - Disconnect the mains power. 1 2 3 4 6 7 8 9 GND MULTI CHANNEL PROGRAMMABLE FILTER-EQUALIZER Terrest rial Ref. : 60 32 UHF +V /00 ma + - Keep on pressing the button, - until the mains is connected again. 1 2 3 4 6 7 8 9 GND MULTI CHANNEL PROGRAMMABLE FILTER-EQUALIZER Terrest rial Ref. : 60 32 UHF +V /00 ma + The software version is now displayed followed by a dot. - Release the button. 11

BLOCK DIAGRAM (BIII) UHF 1 UHF 2 1 2 10 db input amplifier 20 db input amplifier 1 2 3 4 6 7 8 9 30 db attenuator PUT UHF PUT TECHNICAL SPECIFICATIONS Input / Output Number of clusters Input 1 / 1 1 UHF 1 2 / 1 9 UHF 2 Channels 0-12 21-69 21-69 Frequency range (MHz) 174-230 470-862 470-862 Channels 1 1 or 2 1 or 2 1 9 0 Configuration of clusters 1 6 3 1 4 Gain (db) Attenuator (db) / 1 db step 30 30 30 Noise figure (db) 10 6 6 Max. input level (dbµv) 8 9 9 Max. output level* (dbµv) 7 7 7 Selectivity 1 db / 10 MHz 10 db / 10 MHz 10 db / 10 MHz Return loss IN / (db) >10 >10 >10 Selectable power pass Yes Yes Yes Power supply 230-240 V~ / V Consumption (ma) 00 Operating temperature ( C) - to +0 Dimensions (mm) 222 x 142 x 6 * -4 db / IM3 Specifications are su bject to change withou t notice. 08/07 UNITRON n.v. Frankrijklaan 27 B-8970 Poperinge Belgium TEL +32 733 3363 www.johansson.be FAX +32 733 424 e-mail: sales@johansson.be R