Intensity based laser distance measurement system using 2D electromagnetic scanning micromirror

Similar documents
Photonic Devices for Vehicle Evolution

1ms Column Parallel Vision System and It's Application of High Speed Target Tracking

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

MEMS Mirror: A8L AU-TINY48.4

Screen investigations for low energetic electron beams at PITZ

Reducing tilt errors in moiré linear encoders using phase-modulated grating

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

CAEN Tools for Discovery

In-process inspection: Inspector technology and concept

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

MODE FIELD DIAMETER AND EFFECTIVE AREA MEASUREMENT OF DISPERSION COMPENSATION OPTICAL DEVICES

Create an Industrial 3D Machine Vision System using DLP Technology

LD OEM/LD PDS/LD PeCo

Opto-VLSI-based Tunable Linear-Cavity Fibre Laser

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

Characterizing Transverse Beam Dynamics at the APS Storage Ring Using a Dual-Sweep Streak Camera

TG-1000 SPIM functions

Solid State Photon-Counters

Production and Development status of MPPC

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

MEMS Technologies Dresden - Product Development and Fabrication at IPMS Dresden

arxiv:hep-ex/ v1 27 Nov 2003

Innovative Rotary Encoders Deliver Durability and Precision without Tradeoffs. By: Jeff Smoot, CUI Inc

New Medical Light Source using NTT s Communication Laser Technology

Lecture 26 Optical Coherence Tomography

Digital SWIR Scanning Laser Doppler Vibrometer

Company Overview. September MICROVISION, INC. ALL RIGHTS RESERVED.

CHARACTERIZATION OF END-TO-END DELAYS IN HEAD-MOUNTED DISPLAY SYSTEMS

Standard Operating Procedure of nanoir2-s

Transfer Radiation Thermometer With Temperature Range Of 0 C To 3,000 C

Digital SWIR Scanning Laser Doppler Vibrometer

MODIFYING A SMALL 12V OPEN FRAME INDUSTRIAL VIDEO MONITOR TO BECOME A 525/625 & 405 LINE MULTI - STANDARD MAINS POWERED UNIT. H. Holden. (Dec.

Spatial Response of Photon Detectors used in the Focusing DIRC prototype

Model 4700 Photodiode Characterizer

Large photocathode 20-inch PMT testing methods for the JUNO experiment

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

Mobile Phone Camera-Based Indoor Visible Light Communications With Rotation Compensation

Performance of the MCP-PMT for the Belle II TOP counter

Monday 20 May 2013 Afternoon

Illumination-based Real-Time Contactless Synchronization of High-Speed Vision Sensors

The PEFP 20-MeV Proton Linear Accelerator

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

PRODUCT GUIDE CEL5500 LIGHT ENGINE. World Leader in DLP Light Exploration. A TyRex Technology Family Company

Concept of Operations (CONOPS)

Electrical connection

Iterative Learning Control Algorithm for Greatly Increased Bandwidth and Linearity of MEMS Mirrors in LiDAR and Related Imaging Applications

CBF500 High resolution Streak camera

Optical shift register based on an optical flip-flop memory with a single active element Zhang, S.; Li, Z.; Liu, Y.; Khoe, G.D.; Dorren, H.J.S.

The SmoothPicture Algorithm: An Overview

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

S C L M Software Requirements Specification 1.0

ROBOT- GUIDANCE. Robot Vision Systems. Simple by Design

T sors, such that when the bias of a flip-flop circuit is

Test of ScannerMAX Saturn 1 with 600Hz Sine-wave input, having an optical scan angle of 40 optical degrees peak to peak.

Guide to designing a device incorporating MEMSbased pico projection

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

Elements of a Television System

T ips in measuring and reducing monitor jitter

Advanced Sensor Technologies

Impact of DMD-SLMs errors on reconstructed Fourier holograms quality

Entwicklungen der Mikrosystemtechnik. in Chemnitz

Large-Scale Polysilicon Surface Micro-Machined Spatial Light Modulator

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

DPD80 Visible Datasheet

Fast MBAFF/PAFF Motion Estimation and Mode Decision Scheme for H.264

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life

Coincidence Detection using the Broadcom AFBR-S4N44P163 4 x 4 SiPM Array and the Vertilon SIB916 Sensor Interface Board Application Note

Compact multichannel MEMS based spectrometer for FBG sensing

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Electrical connection

Physics Requirements for the CXI Ion Time-of-Flight

HAPD and Electronics Updates

Time Resolution Improvement of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals

Experimental Study on Dual-Wavelength Distributed Feedback Fiber Laser

Comp 410/510. Computer Graphics Spring Introduction to Graphics Systems

EXPERIMENTS WITH THE ACTIVE VIBRATION CONTROL OF A CANTILEVER BEAM

VISION SCANNER2. Next Level Imaging. Simple by Design

DPD80 Infrared Datasheet

Introduction. An AFM/NSOM System with Fluorescence Lifetime Imaging. Application Note

Measurement of overtone frequencies of a toy piano and perception of its pitch

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

VISION SCANNER2. Next Level Imaging. Simple by Design

APPLICATION NOTE. Fiber Alignment Now Achievable with Commercial Software

CONFOCAL MICROSCOPE. Instrument Details: Make: Zeiss. Modal: LSM 700. Specifications: Microscopes

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

Amplifier for fiber optics. Dimensioned drawing

SPATIAL LIGHT MODULATORS

MEMS METROLOGY USING A STROBED INTERFEROMETRIC SYSTEM

Failure Analysis Technology for Advanced Devices

Polygon Scanners Capabilities, Applications and System integration. considerations

The hybrid photon detectors for the LHCb-RICH counters

LUT Luminescence scanners: Seeing what no-one else can

NEXT/RADIUS Shelf Mount CCU

Dual-input hybrid acousto-optic set reset flip-flop and its nonlinear dynamics

FIRST SIMULTANEOUS TOP-UP OPERATION OF THREE DIFFERENT RINGS IN KEK INJECTOR LINAC

Real-time Chatter Compensation based on Embedded Sensing Device in Machine tools

Introduction & Colour

Micromirror-based real image laser automotive head-up display

Transcription:

https://doi.org/10.1186/s40486-018-0073-2 LETTER Open Access Intensity based laser distance measurement system using 2D electromagnetic scanning micromirror Kyoungeun Kim, Jungyeon Hwang and Chang Hyeon Ji * Abstract In this research, we present the feasibility testing results of a simple distance measurement system using microfabricated scanning micromirrors. Two different configurations have been tested with different types of micromirrors. In the first configuration, Lissajous scan pattern has been generated with horizontal scan frequency of 715 Hz, and the intensity of the laser beam reflected from the object has been measured with avalanche photodiode to estimate the distance. The position of the beam has been tracked using a separate position sensitive detector. Signals from both sensors are synchronized by eliminating the signal delay, which enables the detection of the distance of a specific point in the 2-dimensional scan pattern. In the simplified configuration, faster scanning micromirror with horizontal scan frequency of 28.8 khz has been used to increase the resolution and position sensitive detector has been removed from the system by synchronizing the driving current waveform with the avalanche photodiode signals. Distance measurement from 20 to 50 cm has been demonstrated with the developed system. Introduction Recently, technologies related to the optical measurement of 3-dimensional (3D) profile or distance is gaining significant research momentum due to growing needs in various fields of application. LIDAR (light detection and ranging) sensor has become a crucial component for data collection and reconstruction of the 3D space surrounding the autonomous vehicle, and facial or gesture recognition sensors are being actively deployed in hand-held smart devices and automotive vehicles. In general, three different approaches are used for optical distance measurement using the laser beam as a light source, which are TOF (time-of-flight) measurement, triangulation, and intensity measurement methods. The TOF measurement utilizes the time difference between outgoing and incoming laser pulses [1]. Although the long-distance measurement capability with high accuracy makes the technique an attractive choice for applications such as LIDAR systems for autonomous vehicles, complex and costly *Correspondence: cji@ewha.ac.kr Department of Electronic and Electrical Engineering, Ewha Womans University, Seoul 03760, Republic of Korea architecture for photon-counting and autocorrelation algorithms are required. Despite the low system complexity and fast response, utilization of triangulation is limited as the measurable distance is proportional to the reflected laser beam displacement [2]. Intensity measurement method requires a very simple system architecture, which makes it a reasonable choice for short range distance measurement and motion tracking. Laser sensing display and gesture recognition system from the University of Tokyo are good examples of the intensity-based distance measurement systems [3 5]. As the 3D measurement of distance inherently requires the scanning of laser beam in 2D (2-dimensional) space, motorized scanners are widely used in conventional systems. Recently, various approaches have been proposed to utilize MEMS (microelectromechanical systems) scanners in these applications, which can potentially provide a significant reduction of overall volume and cost of the system [1, 6]. In this research, we present the feasibility testing results of a simple distance measurement system using electromagnetic 2D MEMS scanner. In the proposed system, the intensity of the reflected laser beam is measured with APD (avalanche photodiode) The Author(s) 2018. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creat iveco mmons.org/licen ses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Page 2 of 7 to estimate the distance and position of the beam is tracked using PSD (position sensitive detector). As shown in Fig. 1, two different types of electromagnetic 2D MEMS scanners with different scan frequency have been tested, and simplified system without the aid of PSD has also been developed [7]. Distance measurement using a 2D low frequency Lissajous scanner Block diagram and optical setup used in the experiment are shown in Fig. 2. Input beam from the laser diode (LD) is incident on the MEMS scanner to generate a 2D Lissajous scan pattern at the image plane. Half of the steered Fig. 1 Electromagnetic 2D scanning micromirrors used in the experiment: a low-frequency scanner, b high-frequency scanner Fig. 2 Block diagram (top) and optical setup (bottom) of the distance measurement system (Lens in front of APD: 50.8 mm-diameter, f 60, lens in front of PSD: 25.4 mm-diameter, f 125)

Page 3 of 7 beam reflected from the scanner is directed towards the PSD sensor which detects the beam displacement to track the beam position on the scan pattern. The beam reflected from the object goes back to the APD via beam splitter where the intensity is measured. A 638 nm laser diode with 120 mw output power has been used as the laser source, and an electromagnetic 2D scanner with a mirror diameter of 1.2 mm and resonance frequency lower than 1 khz for both scan axes has been used for beam scanning (Fig. 1a). The scanner was originally developed for vector-graphic scanning, but can also be used as a Lissajous scanner by providing sinusoidal input to driving coils for both scan axes [8]. To fully cover the large scan pattern, relatively large optical components have been used including the beam splitter which measured 5 5 5 cm 3. A 5.08 cm-diameter bi-convex lens has been placed in front of the APD sensor to transfer the maximum amount of the reflected beam from the object into a single APD sensor (APD130A2, Thorlabs) with 1 mm-diameter. Figure 3a, b show the actual Lissajous pattern captured at the image plane and scan pattern reconstructed with PSD sensor (PDQ80A, Thorlabs) signal. Scan frequency along the x-axis is 715 Hz and that of the y-axis is 520 Hz. Applied current for the x-axis and y-axis scan are 96 ma and 88 ma, respectively. Optical scan angle is approximately 10.5 for both directions. Discrepancies between the pattern reconstructed with PSD signal and actual scan pattern can be ascribed to the optical misalignment and insufficient resolution of the PSD. To demonstrate the target object scanning and distance measurement, a small circular mirror with a mount has been utilized as the target. To correctly detect the distance of the target object through laser scanning, signals from APD and PSD sensors have to be synchronized. To identify the possible delay between the sensor signals, a low-frequency input pulse has been applied to the LD, and the output signal from the APD and PSD sensors have been measured. As shown in Fig. 4, the APD sensor had almost no delay, while the PSD sensor had a delay of approximately 0.524 ms. Therefore, after acquiring each signal from the sensors, the delay has to be taken into account for synchronization. Figure 5 shows the typical output waveform of the APD sensor. After eliminating the delay between the two signals, the position of the measured point can be obtained by mapping the signals on the same plane as shown in Fig. 6. Distance data for each measurement point can also be acquired in the form of PSD sensor output voltage (intensity of the beam incident on the PSD). In the experimental setup, the distance between the target object (mirror) and the beam splitter is approximately 37 cm. As the intensity of the laser beam entering the PSD sensor varies depending on the position and reflectivity of the target object, distortion of the scan pattern cannot be avoided, which is evident in the scan pattern shown in Fig. 6b. In addition to the removal of the time delay between the two sensor signals, external triggering is required to maintain the scan pattern and thus the position of the measurement points. As the Fig. 4 LD input signal and output signals of the PSD and APD Fig. 3 a Lissaujous scan pattern (area of the scan region is approximately 8 8 cm 2 ), b Lissajous scan pattern reconstructed with PSD sensor signal, c scan pattern generated with 29 khz scanner (area of the scan region is approximately 7 8 cm 2 )

Kim et al. Micro and Nano Syst Lett (2018) 6:11 Fig. 5 Output waveform of the APD sensor Page 4 of 7 output from the PSD has two separate signals for x and y scan axes, the frequency of the external triggering signal is adjusted to the greatest common factor, 65 Hz, of the two scan frequencies. After checking out the feasibility of simultaneously measuring the position and intensity of the laser beam reflected from the high reflectivity mirror object, additional experiments have been conducted to confirm whether it is possible to measure the distance of other low reflectivity materials. Figure 7 shows the measurement result of a paper as the object. Results shown in Figs. 6 and 7 verify that the position and distance measurement of 2D region with various reflectivity is feasible using the proposed method, although the relationship between the measured intensity and distance has to be adjusted depending on the reflectivity of the material. Fig. 6 Position and intensity measurement result: a mirror position inside the scan pattern, b reconstructed scan pattern and intensity measurement points, c intensity of the reflected beam vs. xy position Fig. 7 Position and intensity measurement result of a paper located on the right side: a position of the paper, b intensity of the reflected beam vs. x position, c intensity of the reflected beam vs. xy position

Page 5 of 7 However, as shown in the previous results, the intensity measurement results are distributed unevenly due to the sparse scan pattern generated with a relatively slow scanner. Although not demonstrated in this work, high definition and high frame rate Lissajous scan can be achieved by appropriate selection of the scan frequency without having to increase the scan frequency dramatically [9]. Distance measurement using a 2D high frequency scanner To improve the resolution of the system, electromagnetic 2D scanner with a mirror diameter of 1 mm and horizontal resonance frequency of 28.8 khz has been tested (Fig. 1b). The device was originally designed for a highdefinition pico projection display system, and horizontal and vertical resonance frequencies are 28,775 Hz and 493 Hz, respectively [10, 11]. The operating frequencies are adjusted to generate a scan pattern with the desired area. Used horizontal and vertical scan frequencies are 28,761 Hz and 495 Hz, respectively. Applied current for the x-axis and y-axis scan are 68 ma and 5 ma, respectively. Optical scan angle are approximately 9.2 for the x-axis and 10.5 for the y-axis. Instead of combining the resonance mode actuation for the x-axis and forced mode actuation for the y-axis, resonance mode actuation is used for both axes for simplicity. To maintain a stable scan range, resonance mode actuation requires continuous track and trace of resonance frequency and scan angle, while forced mode actuation requires a PD (proportional-derivative) control to remove the ringing during vertical scan. As the micromirrors used in the experiment are not equipped with integrated deflection angle sensor, we have utilized resonance mode actuation for both axes without feedback control. For the development of more simple and cost-effective device architecture, PSD is removed and driving current waveform and the APD sensor signal are synchronized by 495 Hz rising edge triggering signal. As the output from the function generator passes through a voltage follower circuit to drive the 2D scanner, elimination of the time delay between the function generator and the APD sensor signals is required. The measured time delay is 0.857 ms. To compare the position and distance measurement results, previously experimented mirror object is scanned with Fig. 8 Position and intensity measurement result using 29 khz scanner (mirror position inside the scan pattern (left), intensity of the reflected beam vs. xy position (middle), top view of the graph in the middle (right)): a mirror located in the center, b mirror located on the left side

Page 6 of 7 Fig. 9 Measured intensity vs. distance the high-frequency scanner. As shown in Fig. 8, improved results with more data points have been obtained compared to those achievable with low-frequency scanner. To estimate the actual distance of the object, the intensity of the reflected beam from the object is measured at various distances. The distance of the mirror is adjusted from 20 to 50 cm using an optical rail with a 5 cm step. In Fig. 8, measured data points indicate average values of maximum intensity point for five repeated measurements. According to the results shown in Fig. 9, measurable distance ranges from 20 to 50 cm. Although the proposed intensity-based distance measurement system cannot provide an accurate estimation of the absolute distance, relative differences in intensity or rough estimate of the distance and position of an object in 2D space can be obtained. Therefore, the location and approximate profile of the object can be found. Also, the distance of the object at the center of the scan pattern matches relatively well with the equation derived with distance measurement experiment. When the intensity versus distance equations are established for objects located at various positions and angles, it is possible to detect the distances with more accuracy. Therefore, through more experiments and optimization of the optics, more advanced intensity-based distance sensor using a 2D MEMS scanner can be developed for motion tracking and gesture recognition. Conclusion Feasibility testing result of an intensity-based distance measurement system using 2D MEMS scanning micromirror has been presented. Two types of electromagnetic MEMS scanners with different scan frequency have been utilized to create 2D scan patterns. The optical setup for receiving the reflected laser beam from the target object has been constructed. An APD sensor has been utilized in measuring the intensity of the reflected beam, and a PSD sensor has been utilized for detecting the reflected beam position and scan pattern. By synchronizing the APD and PSD outputs, the position and distance of the object in the 2D space can be detected. Also, the PSD sensor can be removed from the optical setup by synchronizing the input waveform applied to the scanner and the APD sensor signal. Although dependence on object surface roughness and reflectivity could not be removed, detection of approximate distance and the position of the target object with simple architecture using a single APD sensor has been demonstrated. For the object with known reflectivity and position, the distance can be determined with more accuracy. Although further experimentation would be required to improve the accuracy of measurement, the feasibility of utilizing 2D MEMS scanner in an intensity-based distance measurement application has been verified successfully. Authors contributions KK carried out the experiments, and KK, JH, and C-HJ analyzed the experimental results, and drafted the manuscript. All the authors discussed the proposed architecture and experimental results. All the authors read and approved the final manuscript. Competing interests The authors declare that they have no competing interests. Funding This work was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT & Future Planning (2017R1A2B4007830), Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (NRF-2014R1A1A2057721), and by the Center for Integrated Smart Sensors as GFP (CISS-2012M3A6A6054204). Publisher s Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. Received: 6 September 2018 Accepted: 26 November 2018 References 1. Moss R, Yuan P, Bai X, Quesada E (2012) Low-cost compact MEMS scanning LADAR system for robotic applications. Proc. of SPIE 8379:1 9 2. Berkovic G, Shafir E (2012) Optical methods for distance and displacement measurements. Adv Opt Photonics 4:441 471 3. http://www.k2.t.u-tokyo.ac.jp/perce ption /SLP/index -e.html. Accessed 30 Nov 2018 4. Cassinelli A, Zerroug A, Ishikawa M (2010) Camera-less smart laser projector. In: Siggraph 2010 5. Perrin S, Cassinelli A, Ishikawa M (2004) Gesture recognition using laserbased tracking system. In: Proceedings of 6th IEEE International Conference on Automatic Face and Gesture Recognition, pp 541 546 6. Niclass C, Ito K, Soga M, Matsubara H, Aoyagi I, Kato S, Kagami M (2012) Design and characterization of a 256 64-pixel single-photon imager in CMOS a MEMS-based laser scanning time-of-flight sensor. Opt Express 20(11):11863 11881

Page 7 of 7 7. Kim K (2017) Feasibility study on LIDAR sensor using MEMS scanning micromirror. Dissertation Ewha Womans University 8. Han A, Cho AR, Ju S, Ahn S-H, Bu J-U, Ji C-H (2016) Electromagnetic biaxial vector scanner using radial magnetic field. Opt Express 24(14):15813 15821 9. Hwang K, Seo Y-H, Ahn J, Kim P, Jeong K-H (2017) Frequency selection rule for high definition and high frame rate Lissajous scanning. Sci Rep 7:14075 10. Cho AR, Han A, Ju S, Jeong H, Park J-H, Kim I, Bu J-U, Ji C-H (2015) Electromagnetic biaxial microscanner with mechanical amplification at resonance. Opt Express 23(13):16792 16802 11. Ju S, Jeong H, Park J-H, Bu J-U, Ji C-H (2018) Electromagnetic 2D scanning micromirror for high definition laser projection displays. IEEE Photonic Tech Lett. 30(23):2072 2075