technical rider version August 2015 People s Place Stadhouderskade ES Amsterdam

Similar documents
TECHNICAL SPECS SECOND HALL PATRONAAT

Theatre Technical Specifications

mainstage or theatercafe, on demand on demand 103 dba at FOH 6x4x1 meter (if needed bigger) + stairs Max. 4x drumriser (2x1x0,5 meter) No Yes

SHOWBOX SODO TECHNICAL SPECIFICATIONS

Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing)

YAAM Berlin Venue Specifications & Technical Rider. Effective April 2018 Availability, errors and specifications subject to change without notice!

TECHNICAL SPECIFICATION

Ed Blackwell Production Manager Mike Weller Head of Music

Section A: Front of House (FOH) Public Address (PA) Speaker System

Main Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

Get Funked Compact 6-piece. Technical Rider 2017/18. Contents Page 1/2 Technical Rider Page 3 Channel List Page 4 Monitor List Page 5 Stage Diagram

Monty Kultuurfaktorij Technical Rider

TECHNICAL REQUIREMENTS

SHOWBOX AT THE MARKET TECHNICAL SPECIFICATIONS

Barbican Concert Hall Sound System Spec

Les Docks / Av. de Sévelin Lausanne. Technical Rider

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

SOUND TECH RIDER FIDO

Small Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

Project manager (PM): Pamela Næss Mail: Phone:

THE CLASSIC GRAND 18 JAMAICA STREET GLASGOW G1 4QD

Les Docks / Av. de Sévelin Lausanne. Technical Rider. Technical Rider Docks, updated

Multi-Purpose Auditorium Sound Reinforcement System Design ECE Spring Zach Vander Missen Muhammad Farooq Garrett McMindes

Technical Specification for the Alley Theatre, Strabane

Lx-tricks. Lighting and Sound. Your backstage is our centre stage. Hire Price List January 2012 v1.4

Contact. Directions. Stichting Studio301 Overtoom HW Amsterdam The Netherlands.

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

BITUSA 2019 General DRESSING ROOMS

HORACE X PERFORMANCE REQUIREMENTS (Technical)

Project manager (PM): Pamela Næss Mail: Phone:

Technical Rider. For more info : Simon Vaillancourt, Technical director (514)

PRODUCTION BIBLE. last update November 2015

VENUE SPECS Channel Music GmbH. 2 Floor Plan. Falckensteinstr Black Room Berlin. 8 Blue Room. 12 Venue Info

Liteup Events Equipment Brochure 2016

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

Rooming List. Catering & Meals. 10 Hands and 1 Piano TIMELINE SHOW WITH GUEST Tech Sheet

La Gravière/ Chemin de la Gravière 9, 1227 Genève. Technical Rider. Updated 21/10/15

TECHNICAL RIDER SUPERVISION

Treefort Music Fest- March Festival Information Main Stage

Techinal Specifikations

Technical Specification

The Lexington VENUE SPEC. The Lexington Live music venue and whisky lounge. Version 2.5 Updated January 2015

Pioneer set monitor 1 1x DJM 900 nexus 2x CDJ 2000 nexus 2x QSC K12 monitor speaker

RIDER 2018 version 1 English

2017 TECHNICAL SPECIFICATIONS

AUDIO SPEAKERS / AMPLIFICATION

A38 SHIP CONCERT HALL TECHNICAL RIDER 2018!

The Taal Inc. Rhythm Ensemble Tech Rider

"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

Little River Band Production Rider 2018

TECHNICAL SPECIFICATIONS LEPERCQ

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

FASO DANCE COMPANY KALAKUTA REPUBLIK

Malaviya National Institute of Technology Jaipur Jawahar Lal Nehru Marg, JAIPUR (Rajasthan)

Dr JOHN GALLAGHER CONCERT CHAMBER

Tickets will be sold through our ABC account and all tickets are scannable on entry.

Technical Specification Pavilion Dance

v. 2.4 Address: Musikhuset Posten Østre Stationsvej 35 DK-5000 Odense C Booking/management: Morten Østlund

Contact Julianastraat 46, 4301 NC, Zierikzee (NL) +31 (0) (Monday-Friday 13:00-17:00h)

TECHNICAL REQUIREMENTS

City of Villa Rica 2016 Sound and Lighting. THE MILL amphitheater

TECHNICAL SPECS MAIN HALL PATRONAAT

Technical Informa on.zack Theater

TECHNICAL SPECIFICATIONS 2018!

ROSE THEATRE MAIN THEATRE

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

THEATRE EQUIPMENT DECEMBER 2017

SABAN THEATER, BEVERLY HILLS TECHNICAL SPECIFICATIONS

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

TECHNICAL SPECIFICATIONS

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Main House Technical Specification

Technical Rider. (last update: Jan. 2016) For more info: Yves Moquin, technical director (514)

Information for Incoming Companies

LOAD IN / LOAD OUT CARS / SPLITTER VAN / NIGHTLINER THROUGH MAIN ENTRANCE SITUATED AT AUGUSTE ORTSSTRAAT 20-28, 1000 BRUSSEL.

Technical Information

111 North 5 th Street Minneapolis, MN 55403

Technical Services and Specification

US 2015/16 TECH RIDER

SPECIAL EVENTS Hollywood Boulevard Los Angeles, CA

New Theatre Royal Lincoln Technical Information

Mics, DIs, Stands, and Cables

Matt Dann Cultural Centre

Salisbury Arts Centre Technical Specification v Page 1 of 7

Merry Christmas Darling: Carpenters Christmas FULL RIDER 2018 (8-Piece BAND) (Updated March, 2018)

Technical Information

350 fixed seats with the capabilities of an additional 50 removable seats.

Access to back stage is off Fletcher St on the eastern side of the building

SUSAN AGLUKARK. Keynote Speaker/ Solo Presentation TECHNICAL RIDER HOSPITALITY RIDER 2018 Revision 1/15/18 KEY CONTACT:

Ex-Hire Used Equipment Price List

Dinkelspiel Auditorium - Technical Specifications

Analog General Information West End Ave. Nashville, TN, Time Zone: CST

Technical Specifications

Dugdale Centre Technical Specification

Technical Specification (Studio Theatre)

The Haymarket Basingstoke Technical Specifications

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Technical Specifications salle Léo-Poulin

A red velvet front of house curtain closes off the main stage leaving only the apron visible to the audience.

Technical Specification

Transcription:

technical rider version August 2015 People s Place Stadhouderskade 5-6 1054 ES Amsterdam

Technical Rider 2 Index Index... 2 1. Audio... 3 1.1 PA System Stage Area (Main setup)... 3 1.2 PA System Stage Area (optional setup)... 3 1.3 Monitor system... 4 1.4 FOH console... 4 1.5 Microphones... 4 1.6 Stage instruments:... 5 1.7 PA System Bar Area... 5 2. Lights Section... 6 2.1 Lights Stage Area... 6 2.2 Controller... 6 2.3 Lights Bar Area... 6 2.4 Controller:... 6 3. Floorplan Light section... 7 4. Cabling & Power section... 8 4.1 Cabling... 8 4.2 Power supply... 9 5. DJ Gear... 10 6. Video section... 11 6.1 Video Stage Area... 11 6.2 Video Bar Area... 11 7. Dimensions and miscellaneous section... 12 8. Dmx list... 14

Technical Rider 3 1. Audio 1.1 PA System Stage Area (Main setup) Stage speakers Front: 2x Alcons QR36 (Mid/High) 4x Alcons QB363 (Sub) Delay under balcony area (delay fill): 2x Alcons VR8 (Full range) (volume controllable) Delay balcony area (delay fill): 2x Alcons LR7 (Full range) (volume controllable) Extra: facing stage for DJ/Party: 2x Alcons VR12 (Full range) (switchable) PA Amps: 2x Alcons ALC6 (main subs) o 4x 3.000 Watt RMS Class G 1x Alcons ALC4 (main tops) o 2x 2.250 Watt RMS Class G 1x Alcons ALC2 (delays) o 2x 1.050 Watt RMS Class G 2x Alcons ALC2 (balcony) o 4x 1.050 Watt RMS Class G 1x Alcons ALC4 (Facing stage) o 2x 2.250 Watt RMS Class G 1.2 PA System Stage Area (optional setup) Stage speakers: 2x d&b B2 Infra 2x d&b C4 Sub 2x d&b C7 Top PA Amps: 1x d&b Triple Rack with 3x d&b D12 o 6x 1.200 Watt RMS (THD + N 0,1%)

Technical Rider 4 1.3 Monitor system 5 separate groups (4 when using techbooth Soundcraft console) Speakers: 4x d&b Max12 1x d&b Max15 1x d&b E15X-SUB (for drumfill icw. Max15) Amps for monitors 2x 4Audio M720 o 4x 1.100 Watt RMS 1x d&b D6 (for drumfill on request only) 2x 600 Watt RMS PA System is fully EQ ed, time-aligned and processed by a central, LCD touch panel / Crestron controlled Yamaha/RME DSP system. 1.4 FOH console Avid Venue Profile Mixrack, 3x DSP card, 40 mic inputs on stage or 48 at FOH XLR, 8 FOH only line inputs jack, 16 stage or at FOH outputs XLR + 8 FOH only outputs jack, 4+1 AES/EBU I/O XLR. D-show Version 3.11. NO EXTRA PLUG- INS (Standard Avid set only). Other consoles on request FX/Outboard (techbooth only) Lexicon MX400XL (cannot be used with Profile) EQ for monitors (techbooth only) 2x Square One EQ: 4x 31-band GEQ (cannot be used with Profile) 1.5 Microphones 4x Sennheiser e604 1x Shure Beta 52a 2x Neuman KM184 2x Sennheiser e614 6x Shure SM58 1x Shure Beta58 3x Shure SM57 2x Sennheiser e606 1x Sennheiser EW100G3 wireless Handheld (626 MHz band) 1x Sennheiser EW100G3 wireless Beltpack (626 MHz band) 14x K&M Mic Boom Stand High 4x K&M Mic Stand Boom Middle High 3x K&M 210 Mic Boom Stand Short

Technical Rider 5 2x K&M Mic Stand Ultra Short Round Base 3x K&M Mic Table Stand Ultra Short Round Bass 6x BSS AR133 DI 2x Stageline DIB100 passive DI Other -, special - or extra mics available on request 1.6 Stage instruments: Guitar amp o Koch Classic Tone CT40-410C (tube pre, tube end) Bass amp o TC Electronic Combo 450 (programmable) Baby Grand Piano o Yamaha G2 Drum kit - Yamaha Custom Oak drum kit in standard set-up o 22 Kick o 10 Rack Tom o 12 Rack Tom o 16 Floor Tom o Wooden snare o Païste PST Cymbals: 20 Ride; 16 Crash and 14 Hi-Hat (As a courtesy you may use our drum kit and other backline equipment, please be so kind to reassemble the drum kit after changing cymbals and other parts. Thanks!) 1.7 PA System Bar Area Speakers 4x Alcons VR8 (Mid/High) (1 in each corner) 2x Alcons BF151 (Sub) Amps 2x Alcons ALC2 (tops) o 4x 1.050 Watt RMS Class G 1x Alcons ALC4 (subs) o 2x 2.250 Watt RMS Class G The audio system in the bar area is controlled by the Crestron CPU which has LCD touch panel controls in the bar and techbooth. Available sources: video (audio) inputs; FOH stage area; Moodmedia (background music); DJ inputs (bar/techbooth) and aux inputs (bar/techbooth/stage). Audio level Stage Area: Sound levels in this area may not exceed 104 dba SPL (Leq 15 @ 2 mtrs) at FOH position.

Technical Rider 6 2. Lights Section 2.1 Lights Stage Area Fixtures (all at fixed positions) 12x PAR64 MFL 1KW (stage back wall) 4x ADB Profile 2KW (trek 5) 6x JB Lighting A4 LED Moving head (trek 3 & 4) 35x PAR56 WFL 300 Watt House Lights (Not DMX controllable!) 2.2 Controller Avolites Tiger Touch (4x DMX Universe / DMX over LAN) Version 7.2 software. 1 DMX universe in use for the venue, 3 available for extras DMX channel list: see below. NO FREE DIMMER CHANNELS! See separate DMX list for channel - and position details House lights via Crestron, not via DMX nor Tiger Touch 2.3 Lights Bar Area Fixtures (both at fixed position above bar/counter): 2x Robe Robin Spot 300E 2.4 Controller: Same as stage area. On request Different light desk Extra lights

Technical Rider 7 3. Floorplan Light section 12X Par 64 JB Led JB Led JB Led JB Led JB Led JB Led ADB 2KW ADB 2KW ADB 2KW ADB 2KW

Technical Rider 8 4. Cabling & Power section 4.1 Cabling Multi cables LK150 multi 48 ch. (40 inputs/8 outputs configuration) XLR, with XLR male links for monitor desk or recording, 75 meters 1x Installed stage to FOH block in techbooth 24 lines on XLR 1x Separate Socapex snake, 12 pairs, 30 meters 2x Separate XLR snake, 12 pairs, 10 meters 1x Saparate XLR snake, 8 pairs, 10 meters 1x XLR spinner, 6 pairs Cable box: 10x XLR cable 1 meter 25x XLR cable 3 meters 25x XLR cable 6 meters 10x XLR cable 12 meters 4x XLR Female Jack 4x XLR Male Jack 4x XLR female 2x XLR Male 4x XLR Male 2x XLR Female 4x XLR Male XLR Male 2x XLR Female XLR Female 2x Jack cable mono 3 meters 2x Jack cable mono 6 meters 2x Minijack 2x jack 2x Minijack 2x XLR Male 2x Cinch XLR Male 2x Female cinch Jack 1x Minijack Female Minijack Female 4x Speakon coupler 2x Speakon cable 3 meters 1x Speakon cable 5 meters 4x Speakon cable 10 meters 5x Speakon cable 15 meters 2x EP5 cable 5 meters 2x EP5 cable 10 meters 2x EP5 cable 25 meters 2x EP5 Speakon 3x Male shucko 4x Female shucko box 1 meter

Technical Rider 9 5x Male shucko 4x Female shucko box 5 meters 6x Shucko cable, 5 meters Outside cable box 1x CEE 63A 2x32A box 1x CEE 32A 1x CEE 16A + 3xshucko female 16A 2x Shucko Powercon, 3 meters 1x Shucko Powercon, 10 meters 1x Shucko 3x Female shucko box, 10 meters 1x Combi cable powercon + 2x XLR 1x Combi shucko Powercon + 2x XLR 1x Male minijack 2x Male cinch adaptor, 5 meters 1x VGA + Minijack. 3,6 meters 1x VGA + Minijack, 7,6 meters 1x VGA + Minijack, 15,2 meters 4.2 Power supply On stage floor 1x 380VAC-63A/5P (CEE-FORM 63A) 2x 230VAC-16A groups (schuko) In bar area 2x 230VAC-16A groups (schuko) NO power convertors available (UK/US/AUS/etc.)

Technical Rider 10 5. DJ Gear 2x Pioneer CDJ-2000 Nexus 2x Pioneer CDJ-2000 1x Pioneer DJM-900 Nexus 1x Pioneer DJM-800 1x DB Technologies active 6,5 full range monitor on stand Can be used in bar area, techbooth or on stage On request Extra DJ gear

Technical Rider 11 6. Video section 6.1 Video Stage Area projection screen 16:9, motor driven (290cmx163cm) 2 extra free standing foldable Draper screens (4,27 x 2,40m.) available in matt and cineflex. 16:9. 4.500 AL Full HD 16: 10 (native: 1920 x 1200) beamer, motor lift inputs: VGA/CV/RGBHV/YC/YUV on 3 local inputs at 3 positions in venue, on site UPC TV Touch panel control On request: Projectors Video Switchers Preview monitors Cabling Macbooks HDMI input 6.2 Video Bar Area 1x 80 motor lifted Full HD (native: 1.920 x 1.080) LCD screen behind bar 1x 60 Full HD (native: 1.920 x 1.080) LCD screen in Bar Area side wall Inputs: VGA/CV/RGBHV/YC/YUV on 3 local external inputs at 3 locations in venue, on site UPC TV Touch panel control

Technical Rider 12 7. Dimensions and miscellaneous section Main stage Basic stage 7m. wide Depth: 4m. - 2,5m. (dimensions variable, ) 40cm high Optional stage (on top of basic main stage) 9x5m.60,80or100cmhigh Areas: Stage hall: approx. 11 x 13 m., 5,35 m. high Under Balcony: approx. 13,5 x 6 m., 2,5 m. high Bar: approx. 17 x 10 m., 4,3 m. high (All measurements are approximations. No liability.) Bar Area & Rigging Stages in bar area and rigging in venue on special request only.

Technical Rider 13 Europe s FOH Position Backstage rooms Basic Stage Kitchen area Stage area Alt.FOH Position Flightcase Storage Load-in door Balcony Alt. FOH FOH Position Kitchen area Stage area area Position Load-in Street level entrance Bar area Entrance Under Balcony area Load-in door

Technical Rider 14 8. Dmx list Fixture nr. DMX DMX Universe Channel Type Channels used Power Lamp Type Fixture mode Position DMX Cable & Distro 1 1 1 Par 64 MFL 1 1000 Watt Conventional Stage backwall Fixed connection 2 1 2 Par 64 MFL 1 1000 Watt Conventional Stage backwall Fixed connection 3 1 3 Par 64 MFL 1 1000 Watt Conventional Stage backwall Fixed connection 4 1 4 Par 64 MFL 1 1000 Watt Conventional Stage backwall Fixed connection 5 1 5 Par 64 MFL 1 1000 Watt Conventional Stage backwall Fixed connection 6 1 6 Par 64 MFL 1 1000 Watt Conventional Stage backwall Fixed connection 7 1 7 Par 64 MFL 1 1000 Watt Conventional Stage backwall Fixed connection 8 1 8 Par 64 MFL 1 1000 Watt Conventional Stage backwall Fixed connection 9 1 9 Par 64 MFL 1 1000 Watt Conventional Stage backwall Fixed connection 10 1 10 Par 64 MFL 1 1000 Watt Conventional Stage backwall Fixed connection 11 1 11 Par 64 MFL 1 1000 Watt Conventional Stage backwall Fixed connection 12 1 12 Par 64 MFL 1 1000 Watt Conventional Stage backwall Fixed connection 19 1 19 ADB Profile 2KW 1 2000 Watt Conventional Track 5 Fixed connection 20 1 20 ADB Profile 2KW 1 2000 Watt Conventional Track 5 Fixed connection 21 1 21 ADB Profile 2KW 1 2000 Watt Conventional Track 5 Fixed connection 22 1 22 ADB Profile 2KW 1 2000 Watt Conventional Track 5 Fixed connection 101 1 100 JB Lighting A4 14 250 Watt Luxeon Led's Compresses RGB 16 bit Track 3 C11 102 1 116 JB Lighting A4 14 250 Watt Luxeon Led's Compresses RGB 16 bit Track 4 C12 103 1 132 JB Lighting A4 14 250 Watt Luxeon Led's Compresses RGB 16 bit Track 4 C11 104 1 148 JB Lighting A4 14 250 Watt Luxeon Led's Compresses RGB 16 bit Track 3 C12 105 1 164 JB Lighting A4 14 250 Watt Luxeon Led's Compresses RGB 16 bit Track 3 C11 106 1 180 JB Lighting A4 14 250 Watt Luxeon Led's Compresses RGB 16 bit Track 3 C12 201 1 223 Robe Robin 300E spot 32 300 Watt Metal Halide Mode 1 Bar area 202 1 255 Robe Robin 300E spot 32 300 Watt Metal Halide Mode 1 Bar area Please note: All fixtures are mounted at fixed position at a fixed batten (track) and cannot be moved!! Visiting company:dmx25-99 and 300-512 is free to use!! The are no DMX lines from FOH to stage! People s Place only has fixed battens (Tracks) which cannot be lowered. The are no free dimmer channels. Entrance