Level Measurement Continuous level measurement Radar transmitters

Similar documents
Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR250. 5/224 Siemens FI Overview.

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement. Continuous level measurement Radar transmitters. SITRANS LR250 Flanged Encapsulated Antenna. 4/228 Siemens FI

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Continuous level measurement - Capacitance transmitters

Level Measurement Point level measurement RF Capacitance switches

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Flow Measurement SITRANS F M

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Flow Measurement SITRANS F M

SITRANS F M. Transmitter MAG 5000/6000 4/33

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

OPTIFLEX 2200 C/F Technical Datasheet

2291 Guided Wave Radar Level Transmitter

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

Pressure transmitter For applications in hazardous areas Model IS-3

Guided Radar (TDR) Level Transmitter for storage and process applications

Explosion Proof Audible Signal db(a) Series YA60

Pendant Light Fitting IEC Series 6470/2

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

Capacitance Level Measurement Electronic insert FEC 12

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Model JDF Field Indicator

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

TFRN Industrial RTD temperature sensor. CombiTemp TM

Rosemount 1151 Smart Pressure Transmitter

PROPORTIONAL VALVES Sentronic plus

EXLUX ECOLUX C-LUX 6480 Series

TFRH Hygienic RTD temperature sensor. CombiTemp TM

EXLUX ECOLUX 6480 Series

Centurion. Guided Radar. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0. CGR Series.

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

TFRN Industrial RTD temperature sensor. CombiTemp TM

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Process Transmitter RMA 422

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

DMP 331i / DMP 333i LMP 331 i

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Process transmitter RMA422

Guided Wave Radar Level Meter

Inductive sensor NI3-EG08K-Y1-H1341

RMA42. Technical Information

Explosion Proof Audible Signal db(a) Series YA60

Technical Information Gamma Modulator FHG65 Synchronizer FHG66

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

General Specifications

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Modular Lube Lubrication Systems System Controls

Mechanical flow switch for On/Off control

EXPlora. Introduction

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Inductive sensor BI1.5-EG08K-Y1

PMG. Vibration Energy Harvesters

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Liquid Level Sensor Type AKS 4100U

Signal conditioning instruments

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Pendant Light Fittings Series 6050

Technical Information RIA45

Inductive sensor NI10-M18-Y1X-H1141

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Parts List _2.1. Flygt /.890

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Single Point Flow Monitor SW118 SW119

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Liquid Level Sensor AKS 4100U

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

Selection table SITOP power supplies

Liquid Level Sensor Type AKS 4100/4100U

Parts List _2.1. Flygt /.190

associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Inductive sensor With analog output BI15-M30-LI-EXI

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

CombiSeries. Making temperature, pressure and conductivity measurement safe and convenient.

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Operating instructions

2.9 Sigma/ 2 Plunger Metering Pumps

RMA 3000 Remote Meter Assemblies Specifications

Product Data Sheet 4656 EZ

XML LED X M L L E D. Explosionproof Linear LED Lighting

Liquid Level Sensor AKS 4100U

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Transcription:

Overview Configuration Installation Note: Beam angle is the width of the cone where the energy density is half of the peak energy density. The peak energy density is directly in front of and in line with the horn antenna. There is a signal transmitted outside of the beam angle; therefore false targets may be detected. Use largest possible antenna. 19 beam width: 1.5 horn = 19 2.0 horn = 15 3.0 horn = 10.0 horn = 8 SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Benefits Graphical local user interface (LUI) makes operation simple with plug-and-play setup using the intuitive Quick Start Wizard LUI displays echo profiles for diagnostic support 25 GHz high frequency allows for small antennas for easy mounting in nozzles Insensitive to mounting location and obstructions, and less sensitive to nozzle interference Short blanking distance for improved minimum measuring range to 50 mm (2 inch) from the end of the antenna Communication using HART, PROFIBUS PA, or FOUNDATION Fieldbus Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions Programming using infrared Intrinsically Safe handheld programmer or over a network using SIMATIC PDM, Emerson AMS, or Field Device Tools, such as PACTware or Fieldcare via SITRANS DTM Functional Safety (SIL 2). Device suitable for use in accordance with IEC 61508 and IEC 61511 3 mm (0.118 inch) accuracy in accordance with IEC 60770-1 Application SITRANS LR250 includes a graphical local user interface (LUI) that improves setup and operation by including an intuitive Quick Start Wizard, and echo profile displays for diagnostic support. Start-up is easy using the Quick Start wizard with a few parameters required for basic operation. The 25 GHz frequency creates a narrow, focused beam allowing for smaller horn antenna options and decreasing sensitivity to obstructions. SITRANS LR250 s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer without saving to open the instrument s lid. SITRANS LR250 measures superbly on low dielectric media, and in small vessels, as well as tall and narrow vessels. Key Applications: liquid bulk storage tanks, process vessels, vaporous liquids, high temperatures, low dielectric media and applications with functional safety requirements Mounting unit on bypass Orient front or back of device toward vent. Mounting unit on vessel Mounting unit on stilling well Mounting on a nozzle SITRANS LR250 installation, dimensions in mm (inch) Orient front or back of device toward stillpipe slots. Use largest horn size possible in pipe. Min. 10 (0.) /213

Technical specifications Mode of operation Measuring principle Radar level measurement Frequency K-band (25.0 GHz) Minimum measuring range 50 mm (2 inch) from end of antenna Maximum measuring range 20 m (65 ft), antenna dependent Output HART: Version 5.1 Analog output... 20 ma Accuracy ± 0.02 ma Fail-safe Programmable as high low or hold (loss of echo) NE 3 programmable PROFIBUS PA: Profile 3.01 Function blocks 2 Analog Input (AI) FOUNDATION Fieldbus H1 Functionality Basic or LAS Version ITK 5.2.0 Function blocks 2 Analog Input (AI) Performance (according to reference conditions IEC60770-1) Maximum measured error 3 mm (0.118 inch) Influence of ambient temperature < 0.003 %/K Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions (enclosure) Ambient temperature -0... +80 C (-0... +176 F) Installation category I Pollution degree Medium conditions Dielectric constant ε r > 1.6, antenna and application dependent Process temperature -0... +200 C (-0... +392 F) (at process with FKM O-ring) -20... +200 C (-... +392 F) (at process with FFKM O-ring) Process pressure Up to 0 bar g (580 psi g), process and temperature dependent. See Pressure/Temperature curves for more information Design Enclosure Material Aluminum, polyester powder-coated Cable inlet 2 x M20x1.5 or 2 x ½" NPT Degree of protection Type X/NEMA X, Type 6/NEMA 6, IP67, IP68 Weight < 3 kg (6.6 lb) 3.75 mm (1½ inch) threaded with 1½" horn antenna Display (local) Graphic local user interface including quick start wizard and echo profile display Material 316L stainless steel [optional alloy N06022/2.602 (Hastelloy C-22 or equivalent)] Dimensions (nominal horn sizes) Standard 1.5 inch (0 mm), 2 inch (8 mm), 3 inch (75 mm), inch (95 mm) horn and optional 100 mm ( inch) horn extension Process s Process Flange 1½", 2" or 3" NPT [(Taper), ANSI/ASME B1.20.1] R 1½", 2" or 3" [(BSPT), EN 10226] G 1½", 2" or 3" [(BSPP), EN ISO 228-1] 2", 3", " (ANSI 150, 300 lb), 50, 80, 100 mm (PN 16, 0, JIS 10K) Power supply... 20 ma/hart Nominal 2 V DC (max. 30 V DC) with max. 550 Ω PROFIBUS PA 15 ma Per IEC 61158-2 FOUNDATION Fieldbus 20.0 ma Per IEC 61158-2 Certificates and approvals General CSA US/C, CE, FM, NE 21, RCM Radio FCC, Industry Canada and Europe ETSI EN 302-372, RCM Hazardous Explosion Proof (Brazil) INMETRO Ex d ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da Increased Safety (Brazil) INMETRO Ex e ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da Intrinsically Safe (Brazil) INMETRO Ex ia IIC T Ga, Ex ia ta IIIC T100 C Da Explosion Proof (Canada/USA) CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T Intrinsically Safe (Canada/USA) CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T Non-incendive (Canada/USA) CSA/FM Class I, Div. 2, Groups A, B, C, D T5 Flame Proof/Increased Safety NEPSI Ex d ia mb IIC T Ga/Gb, (China) Ex e ia mb IIC T Ga/Gb, Ex iad 20 T90 IP67 DIP A20 T A 90 ºC Intrinsically Safe (China) NEPSI Ex ia IIC T Ga, Ex iad 20 T90 IP67 DIP A20 T A 90 ºC Non-sparking (China) NEPSI Ex na IIC T Gc Intrinsically Safe (Europe) ATEX II 1G Ex ia IIC T Ga ATEX II 1D Ex ia IIIC T100 C Da Non-sparking (Europe) ATEX II 3G Ex na IIC T Gc Flame Proof (International/Europe) IECEx/ATEX II 1/2 GD, 1D, 2D, Ex d mb ia IIC T Ga/Gb, Ex ia ta IIC T100 C Da Increased Safety (International/Europe) Intrinsically Safe (International) Explosion Proof (Russia) Increased Safety (Russia) Intrinsically Safe (Russia) Marine Functional Safety IECEx/ATEX II 1/2 GD, 1D, 2D, Ex e mb ia IIC T Ga/Gb, Ex ia ta IIIC T100 C Da IECEx/ATEX II 1 G Ex ia IIC T Ga, IECEX/ATEX II 1D Ex ia ta IIC T100 C Da GOST-R Ex d GOST-R Ex e GOST-R Ex ia Lloyd's Register of Shipping ABS Type Approval Bureau Veritas SIL-2 suitable in accordance with IEC 61508/61511 /21

Programming Intrinsically Safe Siemens handheld programmer - Approvals for handheld programmer Infrared receiver IS model: ATEX II 1 GD Ex ia IIC T Ga Ex ia D 20 T135 C T a = -20... +50 C CSA/FM Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G, T6 T a =+50 C IECEx SIR 09.0073 Handheld communicator HART communicator 375/75 PC SIMATIC PDM Emerson AMS SITRANS DTM (for into FDT, such as PACTware or Fieldcare) Display (local) Graphic local user interface including quick start wizard and echo profile displays /215

Selection and Ordering data Article No. SITRANS LR250 horn antenna 2-wire, 25 GHz pulse radar level transmitter for 7ML531-77770 - 77 7 7 continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft) (antenna dependent). Ideal for small vessels and low dielectric media. Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Process Connection and Material 316L (1.35 or 1.0) stainless steel, PTFE emitter, FKM seal 1) 0 316L (1.35 or 1.0) stainless steel, PTFE emitter, FFKM seal 1) 1 Hastelloy C-22/2.602 (or equivalent), PTFE emitter, 2 FKM seal 2) Hastelloy C-22/2.602 (or equivalent), PTFE emitter, FFKM seal 2) 3 Process Connection Type Threaded 316L 1½" NPT (ASME B1.20.1) (tapered thread) 3) AA R 1½" [(BSPT), EN 10226-1] (tapered thread) 3) AB G 1½" [(BSPP), EN ISO 228-1] AC (parallel thread) 3) 2" NPT (ASME B1.20.1) (tapered thread) AD R 2" [(BSPT), EN 10226-1] (tapered thread) AE G 2" [(BSPP), EN ISO 228-1] (parallel thread) AF 3" NPT (ASME B1.20.1) (tapered thread) AG R 3" [(BSPT), EN 10226-1] (tapered thread) AH G 3" [(BSPP), EN ISO 228-1] (parallel thread) AJ Flanged 316L 2" Class 150 ASME B16.5 flat faced ) BA 3" Class 150 ASME B16.5 flat faced ) BB " Class 150 ASME B16.5 flat faced ) BC 2" Class 300 ASME B16.5 flat faced ) CA 3" Class 300 ASME B16.5 flat faced ) CB " Class 300 ASME B16.5 flat faced ) CC DN 50 PN 16 EN 1092-1 Type A flat faced ) DA DN 80 PN 16 EN 1092-1 Type A flat faced ) DB DN 100 PN 16 EN 1092-1 Type A flat faced ) DC DN 50 PN 0 EN 1092-1 Type A flat faced ) EA DN 80 PN 0 EN 1092-1 Type A flat faced ) EB DN 100 PN 0 EN 1092-1 Type A flat faced ) EC 50A 10K JIS B 2220 flat faced ) FA 80A 10K JIS B 2220 flat faced ) FB 100A 10K JIS B 2220 flat faced ) FC DN 50 PN 16 DIN EN 1092-1 Type B1 raised face DN 80 PN 16 DIN EN 1092-1 Type B1 raised face DN 100 PN 16 DIN EN 1092-1 Type B1 raised face DN 150 PN 16 DIN EN 1092-1 Type B1 raised face DN 50 PN 0 DIN EN 1092-1 Type B1 raised face DN 80 PN 0 DIN EN 1092-1 Type B1 raised face DN 100 PN 0 DIN EN 1092-1 Type B1 raised face DN 150 PN 0 DIN EN 1092-1 Type B1 raised face GA GB GC GD HA HB HC HD Selection and Ordering data SITRANS LR250 horn antenna 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft) (antenna dependent). Ideal for small vessels and low dielectric media. Flanged Hastelloy C 2" Class 150 ASME B16.5 raised faced ) J A 3" Class 150 ASME B16.5 raised faced ) JB " Class 150 ASME B16.5 raised faced ) JC 2" Class 300 ASME B16.5 raised faced ) JD 3" Class 300 ASME B16.5 raised faced ) JE " Class 300 ASME B16.5 raised faced ) JF DN 50 PN 16 EN 1092-1 Type B1 raised faced ) KA DN 80 PN 16 EN 1092-1 Type B1 raised faced ) KB DN 100 PN 16 EN 1092-1 Type B1 raised faced ) KC DN 50 PN 0 EN 1092-1 Type B1 raised faced ) KD DN 80 PN 0 EN 1092-1 Type B1 raised faced ) KE DN 100 PN 0 EN 1092-1 Type B1 raised faced ) KF 50A 10K JIS B 2220 raised faced ) LA 80A 10K JIS B 2220 raised faced ) LB 100A 10K JIS B 2220 raised faced ) LC DN 50 PN 16 EN 1092-1 Type B1 raised face DN 80 PN 16 EN 1092-1 Type B1 raised face DN 100 PN 16 EN 1092-1 Type B1 raised face DN 150 PN 16 EN 1092-1 Type B1 raised face DN 50 PN 0 EN 1092-1 Type B1 raised face DN 80 PN 0 EN 1092-1 Type B1 raised face DN 100 PN 0 EN 1092-1 Type B1 raised face DN 150 PN 0 EN 1092-1 Type B1 raised face Article No. 7ML531-77770 - 77 7 7 MA MB MC MD ME MF MG MH Communication/Output PROFIBUS PA 1... 20 ma, HART, start-up at < 3.6 ma 2 FOUNDATION Fieldbus 3 Enclosure/Cable inlet Aluminum, Epoxy painted 2 x ½" NPT 0 2 x M20x1.5 1 1½" horn A 2" horn (fits 2" ASME or DN 50 nozzles) B 3" horn (fits 3" ASME or DN 80 nozzles) C " horn (fits " ASME or DN 100 nozzles) D 1½" horn with 100 mm extension E 2" horn with 100 mm extension F 3" horn with 100 mm extension G " horn with 100 mm extension H Hastelloy C22 (or equivalent) 2" horn (fits 2" ASME or DN 50 nozzles) J 3" horn (fits 3" ASME or DN 80 nozzles) K " horn (fits " ASME or DN 100 nozzles) L 2" horn (fits 2" ASME or DN 50 nozzles) with M 100 mm extension 3" horn (fits 3" ASME or DN 80 nozzles) with N 100 mm extension " horn (fits " ASME or DN 100 nozzles) with 100 mm extension P /216

Selection and Ordering data Article No. SITRANS LR250 horn antenna 7ML531-2-wire, 25 GHz pulse radar level transmitter for 77770-77 7 7 continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft) (antenna dependent). Ideal for small vessels and low dielectric media. Approvals General Purpose, CE, CSA, FM, FCC, R&TTE, RCM A Intrinsically Safe: CSA/FM Class I, Div. 1, Groups A, B B, C, D, Class II, Div.1, Groups E,F, G, Class III T FCC, Industry Canada Intrinsically Safe: IECEx/ATEX II 1 G Ex ia IIC T Ga, IECEx/ATEX II 1D Ex ia ta IIIC T100 C Da, C INMETRO Ex ia IIC T Ga, Ex ia ta IIIC T100 o C Da, CE, R&TTE, RCM Non-incendive: CSA/FM Class I, Div. 2, Groups A, D B, C, D T5, FCC, Industry Canada Non Sparking: ATEX II 3G Ex na IIC T Gc, CE, E R&TTE, RCM Increased Safety: IECEx/ATEX II 1/2 GD,1D, 2D Ex e mb ia IIC T Ga/Gb, Ex ia ta IIIC T100 C F Da, INMETRO Ex e ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 o C Da, CE, R&TTE, RCM 5) Flameproof: IECEx/ATEX II 1/2 GD 1D, 2D Ex d mb G ia IIC T Ga/Gb, Ex ia ta IIIC T100 C Da, INMETRO Ex d ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 o C Da, CE, R&TTE, RCM 5) Explosion proof: CSA/FM Class I, II and III, Div.1, Groups A, B, C, D, E, F, G, FCC, Industry Canada 5) H Non Sparking: NEPSI Ex na IIC T Gc K Intrinsically Safe: NEPSI Ex ia IIC T Ga, L Ex iad 20 T90 IP67 DIP A20 T A 90 ºC Flameproof: NEPSI Ex d ia mb IIC T Ga/Gb, M Ex iad 20 T90 IP67 DIP A20 T A 90 ºC 5) Increased Safety: NEPSI Ex e ia mb IIC T Ga/Gb, N Ex iad 20 T90 IP67 DIP A20 T A 90 ºC 5) Pressure rating Rating per Pressure/Temperature curves in manual 0 0.5 bar g (7.25 psi g) maximum 1 1) Available with process options AA... HD & Versions A... H only 2) Available with process options JA... MH & Versions J... P only 3) Available For antenna versions A and E only, max. range 10 m (32.8 ft), dk > 3. Can measure dk >1.6 [] when mounted in a stillpipe/ bypass. ) Siemens Milltronics type flange (flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN 1092-1, or JIS B 2220 standard), see operating instructions for details 5) Applicable with communication option 2 only We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /217

Selection and Ordering data Order code Further designs Please add "-Z" to Article No. and specify Order code(s). Plug M12 with mating Connector 1)2)3) A50 Plug 7/8" with mating Connector 2)3)) A55 Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters); specify in plain text Manufacturer's Test Certificate: M to DIN 55350, Part 18 and to ISO 9000 Inspection certificate 3.1 of EN 1020 C11 C12 Functional Safety (SIL 2). Device suitable for use in C20 accordance with IEC 61508 and IEC 61511 3)5) Namur NE3 compliant, device preset to failsafe N07 <3.6mA 5) Operating Instructions for HART/mA device Article No. English A5E32220602 German A5E32376088 Note: The Operating Instructions should be ordered as a separate line item on the order. Compact Operating Instructions for HART/mA device English, French, German, Spanish, Italian, Dutch, A5E3369191 Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, A5E3369171 Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese A5E306583 This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library. Operating Instructions for PROFIBUS PA device English A5E32221386 German A5E3237609 Note: The Operating Instructions should be ordered as a separate line item on the order. Compact Operating Instructions for PROFIBUS PA device English, French, German, Spanish, Italian, Dutch, A5E3369239 Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, A5E3372685 Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese A5E30662 This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library. Selection and Ordering data Operating Instructions for FOUNDATION Fieldbus device English German Note: The Operating Instructions should be ordered as a separate line item on the order. Compact Operating Instructions for FOUNDATION Fieldbus device English, French, German, Spanish, Italian, Dutch, Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library. Accessories Handheld programmer, Intrinsically safe, EEx ia HART modem/usb (for use with a PC and SIMATIC PDM) One metallic cable gland M20x1.5, rated -0... +80 C (-0... +176 F), HART (two are required) One metallic cable gland M20x1.5, rated -0... +80 C (-0... +176 F), PROFIBUS PA and FOUNDATION Fieldbus (two are required) 6) FDA approved FKM o-ring for 2" G (BSPP) process s -28... +80 C (-28... +176 F) SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section Article No. A5E3222111 A5E32376112 A5E3372700 A5E3372738 A5E306626 7ML1930-1BK 7MF997-1DB 7ML1930-1AP 7ML1930-1AQ 7ML1830-3AN 7ML571-... 7ML570-... 7ML57-... 7ML5750-... 1) Available with enclosure option 1 only 2) To be used with communication options 1 and 3 only. Connector has IP67 rating. 3) Available with approval options A and B. Available with approval option C for use on intrinsically safe applications only. Not rated for dust Ex. ) Available with enclosure option 0 only 5) Applicable to communication option 2 only 6) For use with communication option 1 and 3 only We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /218

Characteristic curves Maximum flange and process temperatures versus allowable ambient temperature Ambient temperature ( C) 90 130 C 80 70 65 C 60 50 0 30 20 10 0 0 20 0 60 80 100 120 10 160 180 200 220 Process flange surface temperature ( C) SITRANS LR250 Ambient/Process Flange Surface Temperature Curve /219

Dimensional drawings Threaded Horn 50 (2.0) ½" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 15 (6.1) 167 (6.6) 90 (3.5) Enclosure/ electronics 28 (1.1)* 196 (7.7) Retaining collar Process device tag Horn 159 (6.26) Sensor reference point See dimension table for height to sensor reference point O.D. O.D. *28 mm (1.1) for 1.5 inch and 2 inch, 2 mm (1.65) for 3 inch Type O.D. 1-1/2" threaded Height to sensor reference point 2" threaded 3" threaded Beam angle Measurement range 1.5" horn 2" horn 139.8 (5.57) 17.8 (5.88) 135 (5.3) 166 (6.55) 180 (7.09) 19 degrees 15 degrees 10 m (32.8 ft) 3" horn 17.8 (6.9) 199 (7.85) 213 (8.39) 10 degrees " horn 19.8 (7.73) 25 (10) 268 (10.55) 8 degrees SITRANS LR250 Threaded Horn, dimensions in mm (inch) /220

Threaded Horn with Extension 50 (2.0) ½" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 15 (6.1) 167 (6.6) 90 (3.5) Enclosure/ electronics 196 (7.7) Retaining collar 159 (6.26) Sensor reference point 28 (1.1)* Process device tag See dimension table for height to sensor reference point O.D. Horn O.D. *28 mm (1.1) for 1.5 inch and 2 inch, 2 mm (1.65) for 3 inch Type 1.5" horn 2" horn 3" horn " horn O.D. 139.8 (5.57) 17.8 (5.88) 17.8 (6.9) 19.8 (7.73) 1-1/2" threaded 235 (9.3) Height to sensor reference point 2" threaded 266 (10.55) 299 (11.85) 35 (1) 3" threaded 280 (11.09) 313 (12.39) 368 (1.55) Beam angle 19 degrees 15 degrees 10 degrees 8 degrees Measurement range 10 m (32.8 ft) SITRANS LR250 Threaded Horn with Extension, dimensions in mm (inch) /221

Flanged Horn 50 (2.0) ½" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 15 (6.1) Enclosure/ electronics 167 (6.6) 90 (3.5) Name-plate 227 (8.9) Flange Retaining collar 190 (7.8) horn 135.3 5.32 168.3 6.62 223.3 8.79 Process tag 50 (2) nominal 80 (3) nominal 100 () nominal horn O.D. Nominal Horn Size 50 (2) 80 (3) 100 () Horn O.D. 17.8 (5.88) 17.8 (6.9) 19.8 (7.73) Height to sensor reference point Stainless steel flange raised or Optional alloy flange flat-faced 135.3 (5.32) 138.3 (5.) 168.3 (6.62) 171.3 (6.7) 223.3 (8.79) 226.3 (8.90) Beam angle 15 degrees 10 degrees 8 degrees Measurement range SITRANS LR250 Flanged Horn, dimensions in mm (inch) /222

Flanged Horn with Extension 50 (2.0) ½" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 15 (6.1) enclosure/ electronics 167 (6.6) 90 (3.5) 227 (8.9) flange name-plate retaining collar 190 (7.8) Sensor reference point process tag horn 235.3 (9.32) 268.3 (10.62) 323.3 (12.79) 50 (2) nominal 80 (3) nominal 100 () nominal Horn O.D. Nominal Horn Horn O.D. Height to sensor reference point Beam angle Measurement Size Stainless steel range flange raised or Optional alloy flange flat-faced 50 (2) 80 (3) 100 () 17.8 (5.88) 17.8 (6.9) 19.8 (7.73) 235.3 (9.32) 268.3 (10.62) 323.3 (12.79) 238.3 (9.) 271.3 (10.7) 326.3 (12.90) 15 degrees 10 degrees 8 degrees SITRANS LR250 Flanged Horn with Extension, dimensions in mm (inch) /223

Schematics Connect the wires to the terminals as shown: the polarity is identified on the terminal block. Hand Programmer Notes: Gland Shield for HART, PROFIBUS PA, and FOUNDATION Fieldbus Intrinsically Safe versions only. 1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable safety requirements of IEC 61010-1. 2. All field wiring must have insulation suitable for rated input voltages. 3. Use shielded twisted pair cable (1... 22 AWG) for HART version.. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes. Part number: 7ML1930-1BK SITRANS LR250 s /22

SITRANS LR250 Specials SITRANS LR250 Specials SITRANS LR250 Specials Article No. Article No. SITRANS LR250 horn version enclosures (PROFIBUS PA models) SITRANS LR250 horn version enclosures (< 3.6 ma start-up HART) NPT cable inlet, approval option A, M20 cable inlet, approval option A, NPT cable inlet, approval option B, M20 cable inlet, approval option B, NPT cable inlet, approval option C, M20 cable inlet, approval option C, M20 cable inlet, approval option C, M20 cable inlet, approval option D, LR250 enclosure with board stack, NPT cable inlet, approval option B, with FOUNDATION FIELDBUS communication, LR250 enclosure with board stack, NPT cable inlet, approval option D, with FOUNDATION FIELDBUS communication, LR250 enclosure with board stack, M20 cable inlet, approval option E, with FOUNDATION FIELDBUS communication, SITRANS LR250 horn version enclosures (FOUNDATION Fieldbus models) A5E01156836 A5E01156838 A5E01156839 A5E0115681 A5E0115683 A5E011568 A5E0115686 A5E0115688 A5E03769538 A5E03769539 A5E0376953 SITRANS LR250 horn version enclosure with board stack, M20 cable inlet, approval option A, with HART communication start-up at < 3.6 ma, SITRANS LR250 horn version enclosure with board stack, M20 cable inlet, approval option C, with HART communication start-up at < 3.6 ma, SITRANS LR250 horn version enclosure with board stack, M20 cable inlet, approval option E, with HART communication start-up at < 3.6 ma, SITRANS LR250 horn version enclosure with board stack, M20 cable inlet, approval option F, with HART communication start-up at < 3.6 ma, SITRANS LR250 horn version enclosure with board stack, M20 cable inlet, approval option G, with HART communication start-up at < 3.6 ma, NPT cable inlet, approval option A, with HART communication start-up at < 3.6 ma, no process NPT cable inlet, approval option B, with HART communication start-up at < 3.6 ma, no process NPT cable inlet, approval option D, with HART communication start-up at < 3.6 ma, no process NPT cable inlet, approval option H, with HART communication start-up at < 3.6 ma, no process SITRANS LR250 horn antenna and extension kits 38 mm (1.5 inch) horn antenna kit, 1.5" Process Connections only A5E02956317 A5E02956319 A5E02956320 A5E02956322 A5E02956323 A5E031096 A5E031097 A5E031098 A5E031099 A5E01151539 100 mm ( inch) horn antenna extension kit, 1.5" Process Connections only A5E01151553 50 mm (2 inch) stainless steel 316L horn antenna kit A5E01151569 M20 cable inlet, approval option C, with FOUNDATION Fieldbus communication, NPT cable inlet, approval option A, with FOUNDATION Fieldbus communication, M20 cable inlet, approval option A, with FOUNDATION Fieldbus communication, NPT cable inlet, approval option C, with FOUNDATION Fieldbus communication, A5E0265608 A5E02653792 A5E02653793 A5E0265606 75 mm (3 inch) stainless steel 316L horn antenna kit A5E01151571 100 mm ( inch) stainless steel 316L horn antenna kit A5E01151573 100 mm ( inch) horn antenna extension kit, A5E01151577 50 mm (2 inch), 75 mm (3 inch) and 100 mm ( inch) process 50 mm (2 inch) horn antenna kit, Hastelloy C-22 A5E0115158 75 mm (3 inch) horn antenna kit, Hastelloy C-22 A5E01151585 100 mm ( inch) horn antenna kit, Hastelloy C-22 A5E01151587 5 Dupont 1Gr Polyback, PTFE grease kit A5E01151626 LR250 lid with O-ring A5E026510 /225