Enhanced quantum efficiency bialkali photo multiplier tubes

Similar documents
Very High QE bialkali PMTs

Review of High Quantum Efficiency Large Area Photomultiplier Tubes

Lifetime of MCP-PMTs

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

UniMCO 4.0: A Unique CAD Tool for LED, OLED, RCLED, VCSEL, & Optical Coatings

Nuclear Instruments and Methods in Physics Research A

Spatial Response of Photon Detectors used in the Focusing DIRC prototype

Operating Instructions for PMT Tube P3

Development of OLED Lighting Panel with World-class Practical Performance

Spectroscopy on Thick HgI 2 Detectors: A Comparison Between Planar and Pixelated Electrodes

Experimental Astrophysics Group, Space Sciences Laboratory, 7 Gauss Way, University of California, Berkeley, CA 94720

3-D position sensitive CdZnTe gamma-ray spectrometers

Lifetime of MCP-PMTs

Organic Electronic Devices

Screen investigations for low energetic electron beams at PITZ

HAPD and Electronics Updates

Cathode Studies at FLASH: CW and Pulsed QE measurements

Comparison of SONY ILX511B CCD and Hamamatsu S10420 BT-CCD for VIS Spectroscopy

Wavelength selective electro-optic flip-flop

First operation of cesium telluride photocathodes in the TTF injector RF gun

Sep 09, APPLICATION NOTE 1193 Electronic Displays Comparison

The use of remote phosphor technology in EVE-L series LED lighting fixtures with method of protection II 2GD Ex de IIC T6 Gb / Ex tb IIIC T85 Db IP66

CHAPTER 9. Actives Devices: Diodes, Transistors,Tubes

Data. X-ray Image Intensifier HIDEQ 23-3 ISP

The hybrid photon detectors for the LHCb-RICH counters

Performance of the MCP-PMT for the Belle II TOP counter

The 20 inch MCP-PMT R&D in China

VERY HIGH VOLTAGE PHOTOEMISSION ELECTRON GUNS*

SPE analysis of high efficiency PMTs for the DEAP-3600 dark matter detector

Light Emitting Diodes

Organic Light Emitting Diodes (OLEDs) Physics 496/487 Matt Strassler

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

GMOS CCD Upgrade Options S. Kleinman, J. Jensen 26Sep08

Photocathodes FLASH: Quantum Efficiency (QE)

Silole Derivative Properties in Organic Light Emitting Diodes

Thick Pixelated CZT Detectors With Isolated Steering Grids

High Efficiency White OLEDs for Lighting

Compact size (16 mm diameter, 12 mm seated length), Fast Time response (rise time 0.78 ns)

Production and Development status of MPPC

Development of an Abort Gap Monitor for High-Energy Proton Rings *

Light-Emitting Diodes

Large photocathode 20-inch PMT testing methods for the JUNO experiment

A very brief review of recent SiPM developments

Journal of Luminescence

The SLAC Polarized Electron Source *

OLED Technology Introduction

Development at Jefferson Lab

Image Intensifier User Guide

16-element Si photodiode arrays

Application note. Materials. Introduction. Authors. Travis Burt, Huang ChuanXu*, Andy Jiang* Agilent Technologies Mulgrave, Victoria, Australia

First evaluation of the prototype 19-modules camera for the Large Size Telescope of the CTA

Stacked OLEDs for Lighting Applications - Improvement of the yellow building block

Activities on FEL Development and Application at Kyoto University

Optical Perfection. HIGHYAG Beam Delivery Products

VTA0832H Series Linear Photodiode Array (PDA) for X-ray Scanning

Hamamatsu R1584 PMT Modifications

VTA1216H Series Linear Photodiode Array (PDA) for X-ray Scanning

DEVELOPMENT OF WDM OPTICAL TRANSMISSION SYSTEM OVER GI-POF PAIR CABLE FOR TELEVISION RF, GIGABIT-ETHERNET, AND HDMI/DVI

THE DIGITAL FLAT-PANEL X-RAY DETECTORS

New product of near infrared (to 900 nm) detection

Nuclear Instruments and Methods in Physics Research 221 (1984) North-Holland, Amsterdam

Photodetector Testing Facilities at Nevis Labs & Barnard College. Reshmi Mukherjee Barnard College, Columbia University

Quantum Dot Solutions for Lighting and Display Applications. Frank Ignazzitto APEC Conference February 9, 2012

High gain L-band erbium-doped fiber amplifier with two-stage double-pass configuration

Challenges in the design of a RGB LED display for indoor applications

UVscope an instrument for calibration support

High contrast tandem organic light emitting devices employing transparent intermediate nano metal layers and a phase shifting layer

Illumination Challenges in Non- Industrial Vision Applications. Simon Stanley Managing Director ProPhotonix IRL Ltd

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

EUROFEL-Report-2007-DS EUROPEAN FEL Design Study

Introduction to Fiber Optic Cable Technology Jerry Bednarczyk, PE Course Content

Development of OLED Lighting Applications Using Phosphorescent Emission System

Monitor QA Management i model

Updates on the Central TOF System for the CLAS12 detector

Review of photo-sensor R&D for future water Cherenkov detectors NNN10 Dec

3 EXPERIMENTAL INVESTIGATIONS Caroline Robson. 3.1 Aims and Objectives. 3.2 Experimental Method Set Up of the Test Stand

Effective photosensitive* 2 area size. Storage temperature Tstg (mm) ( C) ( C) S φ0.2 φ0.5 S φ to to +100 S9075

16-element Si photodiode arrays

Study of Timing and Efficiency Properties of Multi-Anode Photomultipliers

DARK CURRENT IN SUPERCONDUCTING RF PHOTOINJECTORS MEASUREMENTS AND MITIGATION

HOLLOW CATHODE LAMPS PRODUCT BROCHURE

M=100, RL=50 Ω λ=800 nm, -3 db

New Medical Light Source using NTT s Communication Laser Technology

Novel persistent phosphors of lanthanide-chromium co-doped. yttrium aluminum gallium garnet: design concept with vacuum

High QE Photocathodes lifetime and dark current investigation

Results of recent photocathode studies at FLASH. S. Lederer, S. Schreiber DESY. L. Monaco, D. Sertore, P. Michelato INFN Milano LASA

Nanostructured super-period gratings and photonic crystals for enhancing light extraction efficiency in OLEDs

High Performance White OLEDs Technologies for Lighting

Photoinjector Laser Operation and Cathode Performance

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 5, OCTOBER

3/2/2016. Medical Display Performance and Evaluation. Objectives. Outline

PROCESS TECHNOLOGIES FOR ADVANCED ORGANIC ELECTRONIC DEVICES: MICRODISPLAYS, LIGHTING AND SOLAR CELLS

LED Display Product Data Sheet LTS-2306CKD-P Spec No.: DS Effective Date: 07/20/2013 LITE-ON DCC RELEASE

DATA ACQUISITION FOR MONOLITHIC SCINTILLATION DETECTORS IN PET APPLICATIONS

Photon detectors. J. Va vra SLAC

ABORT DIAGNOSTICS AND ANALYSIS DURING KEKB OPERATION

Murdoch redux. Colorimetry as Linear Algebra. Math of additive mixing. Approaching color mathematically. RGB colors add as vectors

CCD220 Back Illuminated L3Vision Sensor Electron Multiplying Adaptive Optics CCD

Physics of high-current diode

ELECTRON OPTICS OF ST-X, ST-Y SERIES OF STREAK & FRAMING CAMERA TUBES

Transcription:

Nuclear Instruments and Methods in Physics Research A 572 (2007) 449 453 www.elsevier.com/locate/nima Enhanced quantum efficiency bialkali photo multiplier tubes Razmick Mirzoyan, Florian Goebel, Juergen Hose, Ching Cheng Hsu, Jelena Ninkovic, David Paneque, Agnes Rudert, Masahiro Teshima Max-Planck-Institut für Physik, Föhringer Ring 6, D-80805 München, Germany Available online 8 December 2006 Abstract Currently, the classical PMTs with semitransparent bialkali photo cathode show peak quantum efficiency (QE) of 25 27%. Although the above-mentioned peak QEwas achieved already 40 years ago, nevertheless one cannot report any significant increase since then. A couple of years ago we started a development program with the main PMT manufacturers Photonis, Electron Tubes and Hamamatsu, aiming to boost-up the peak QEof the (1 2) 00 size bialkali PMTs. Today we want to report that our efforts were successful: all of the three above-mentioned companies succeeded to boost the peak QEof bialkali PMTs to the level of 30 35%. In this report, we want to show the QEmeasurements of different tubes and discuss the future prospects. For example, it shall be possible to use the diffuse-scattering matt lacquer coating technique in order to enhance further the QE. In our previous experience application of that coating provided 15% increase in QEfor 1 1.5 00 hemispherical tubes. r 2006 Elsevier B.V. All rights reserved. PACS: 80 Keywords: Quantum efficiency; Photo multiplier tubes; Bialkali photo cathodes; Light sensors; Low light level sensors 1. Introduction Corresponding author. Tel.: +49 89 323 543 28; fax: +49 89 322 67 04. E-mail address: razmik@mppmu.mpg.de (R. Mirzoyan). The classical PMTs were invented in the mid-1930s. Since the very beginning they have revolutionized the physics experiments. Also, they had a strong impact on other disciplines or applications where it was necessary to measure very fast low light level (LLL) signals. Initially, the photo cathodes had very low peak QEon the order of 1% but in the following 20 25 years it was increased to the level of 25%. It may sound surprising but one cannot report any significant increase of the peak QEvalue after that. One possible explanation could be the fact that most PMT users (including industrial applications, like for example, in g- cameras and in positron emission tomography (PET) in medical diagnostics) are working in conditions when there is enough light. Those who are working with LLL signals are in minority (these are mostly scientists working in astronomy and astroparticle physics). Especially in the case of LLL applications, it is becoming important to provide high signalto-noise ratio. As one can see from formula (1) below, the signal-to-noise ratio depends on the QEvalue Z andonthe number of incident photons N as p signal=noise ¼ ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi N Z=ð1 ZÞ. (1) In order to provide a relatively high signal-to-noise ratio, especially at low number of incident photons, one needs to provide high QE. 2. Short historical review Below we want to list the main historical milestones that made it possible to develop and produce state-of-the-art PMTs: 1889: Elster and Geitel [1] discovered that in alkali metals a photo-electric effect can be induced by visible light (the existence of the e was yet unknown). 1905: Einstein [2] put forward the concept that photoemission is the conversion of a photon into a free e. 1910: Photoelectric effect on K Sb compound was found [3]. 0168-9002/$ - see front matter r 2006 Elsevier B.V. All rights reserved. doi:10.1016/j.nima.2006.11.047

450 ARTICLE IN PRESS R. Mirzoyan et al. / Nuclear Instruments and Methods in Physics Research A 572 (2007) 449 453 1923: found that thermionic emission of W is greatly enhanced when exposed to Cs vapour [4]. It was found that the work function in the above case was lower than of Cs metal in bulk. Until 1930 QEof available materials was o10 4. 1929: discovered Ag O Cs photo-emitter (Koller; Campbell) improved the QEto the level of 10 2 [5,6]. First important commercial application: reproduction of sound for film. 1936: discovered high efficiency of Cs Sb (Go rlich) [7]. Improved photo cathode materials were discovered later on but it was a combination of a good luck with intelligent guessing. A very important step was to realize that the photo cathode materials are semiconductors. By comparing the metallic versus nonmetallic materials one can say that 1. the yield of metallic photo cathodes is very low because of initial very high reflectivity, 2. semiconductors have less reflection losses and correspondingly higher yield (see below). The main loss process in metals is the e scattering; e escape depth of only few atomic layers is possible. The losses in semiconductors because of phonon scattering (interaction with lattice) are much less, i.e. e from deeper layers can reach the surface. The measured escape depth was 10 20 atomic layers for K, Rb, Cs. It is interesting to mention that for photon energies X12 ev QEvalues of 1 10% were reported for Ni, Cu, Pt, Au, W, Mo, Ag and Pd [8]. More concrete, for example, 7% QEwas reported for Au at 15 ev and 2% for Al at 17 ev. In 1955 1958 Sommers found the multialkali effect: combination of Cs K Na Sb has high QEin the visible spectrum (see for a historical review and for details [9]). Also were discovered Cs 3 Sb on MnO (S11, QE peak 20% at 400 nm), (Cs)Na 2 KSb (S20, QE peak 30% at 400 nm), K 2 CsSb (QE peak 30% at 400 nm), K 2 CsSb(O) (QE peak 35% at 400 nm). One can see from the above list that peak QEvalues in the range of 20 30% were reported already at the end of the 1950s and at the beginning of the 1960s. Nevertheless, until very recently the commercially available PMTs had QEvalues of 25%. 3. Increase of the QE of PMTs Below we want to list the main factors that can allow one to enhance the QEof PMTs: Use of highly purified materials for the photo cathode composition (for example, change from 99.999% purity of materials to 99.9999% or even higher). Optimal tuning of the photo cathode thickness. Optimal tuning of the material composition and their treatment. Optimal tuning of the anti-reflective layer. Recycling of the photons that pass through the semitransparent photo cathode without interaction. The first of the above points shall have a dominant effect. For the given thickness this will provide less scattering length for e (low recombination probability). Under this condition the e released from deeper layers can reach the photo cathode-vacuum junction and can contribute into photo current. Tuning of the photo cathode thickness shall be decisive for the peak position of the QEcurve. The given thickness shall define the wavelength range where light interference is important that can be used to enhance the QE. Perhaps there is not much freedom in the selection of photo cathode materials, their composition and used technologies. Still an optimal composition shall be important in order to provide a possibly wide and high spectral response. Optimal tuning of the anti-reflective layer is related with the photo cathode thickness as well as with the possibility to use special layers in the junction between the photo cathode and the glass envelope. Our earlier measurements have shown that 10 30% of incident light (correspondingly the lower value in the blue, increasing towards the higher one in the red part of the spectrum) is reflected back from the photo cathode because of its high refractive index. Optimally tuned anti-reflective layer could reduce the reflection losses and increase the QE. The last point in the above list can also contribute into the increase of QEon a few percent level: one needs to make (coat) the surrounding surfaces of the PMT input chamber from a highly reflective material. 4. The measurements In our measurements we used a spectrophotometer assembled from commercial parts. As a reference we used a10 10 mm calibrated diode from Hamamatsu that has a calibration precision of 2%. The spectrophotometer and the diode were driven and read out via Lab-View under the computer control. A central 5 15 mm diameter of the photo cathode area of PMTs were illuminated. Usually, a potential difference of 200 V was applied between the photo cathode and the first dynode and then the photo current was measured by using a picoammeter Keitley 485. All the other dynodes were shorted with the first one. 4.1. Hamamatsu PMTs Earlier we have reported about QE measurements of few 2 00 size flat window bialkali PMTs from Hamamatsu of type R878 [10]. They showed peak QEvalues of 33 36% (see, for example, the measured QEof PMT #WS7454 in Fig. 1). The PMT #WS7454 shows a QEcurve that is

R. Mirzoyan et al. / Nuclear Instruments and Methods in Physics Research A 572 (2007) 449 453 451 above 30% in the wavelength range of 330 460 nm with a peak value 33% at 370 nm. In Fig. 2 are shown the measured QEcurves for three 1 00 size PMTs with hemispherical windows: two from Hamamatsu (type R7373, #5038 and #5043) and one from Electron Tubes (type ET9116 A, PMT #1930). The latter PMT stems from a few years ago production cycle and was used for reference purposes. As one can see the PMT from Electron Tubes shows a relatively low peak QE of about 25% while the PMTs from Hamamatsu show peak QEvalues of 31% and 33%. While the QEpeak position for the Electron Tubes PMT is at 380 nm, it has a flat shape in the wavelength range 330 390 nm for the Hamamatsu PMT #5043 and again, it has a (rather unusual) relatively flat shape in the wavelength range 290 380 nm for the PMT #5038. While the PMT from Electron Tubes shows only a QE of 11% at 300 nm (this relatively low value is also due to the light absorption in the used BK-7 type of glass for the entrance window), the PMTs from Hamamatsu show correspondingly 28% (#5043) and 31% (#5038) QEat the same wavelength. One can see some other striking difference in Fig. 2, namely that the PMTs have rather different QEvalues for wavelengths above 450 nm. Both Hamamatsu PMTs, in spite of their different QEvalues at shorter wavelengths, show essentially the same QEfor wavelengths 4450 nm. The PMT from Electron Tubes shows systematically higher QEthan those of Hamamatsu for wavelengths 4450 nm. For example, while the Hamamatsu PMTs show a QEof only 6% for the wavelength 550 nm, the Electron Tubes PMT shows a QEof 12%. 4.2. Electron tubes PMTs In Fig. 3 are shown measured QEcurves for five PMTs with hemispherical windows, again of 1 00 size, from Electron Tubes. Looking into the QE curves from right to the left, one can see that the peak QEvalue of these PMTs is shown in increasing order. The lowest peak QEof Fig. 1. Measured QEof 2 00 Hamamatsu. size PMT R878 (serial #WS7454) from Fig. 2. Measured QEcurves for three 1 00 size PMTs with hemispherical windows: two from Hamamatsu and one from Electron Tubes. Fig. 3. Measured QEcurves of five 1 00 size PMTs with hemispherical windows from Electron Tubes from different production iterations.

452 ARTICLE IN PRESS R. Mirzoyan et al. / Nuclear Instruments and Methods in Physics Research A 572 (2007) 449 453 26% (at 360 nm) has the PMT of type ET9116A (serial #1930) and the highest QEof (30 31)% (in the wavelength range of 330 390 nm) has the PMT of the type D822WA (serial #142). It is interesting to note that if the peak QEof a given PMT is higher, then its entire curve is shifted towards the shorter wavelengths. One may speculate that when thinning the photo cathode, the response in the shortwavelength part shall increase because of the light interference in the photo cathode and neighbouring junctions, while the response at longer wavelengths shall drop. 4.3. Photonis PMTs Also several PMTs from few production iterations were obtained from Photonis. While the measurements of two PMTs of type XP5312 (3 00 size, with flat entrance window) showed a peak QEof 30%, an experimental PMT of the type XP3422 (flat window, 2 00 size, #82410) showed a peak QEof 34% [10]. The QEcurve of this latter PMT had somewhat unusual, narrow shape: one could observe a steep drop of QEfor wavelengths 4400 nm. Also, several PMTs of type XP31T2 of 1 00 size (with hemispherical window, but about twice as long as the 1 00 PMTs from Electron Tubes and Hamamatsu) were obtained from Photonis. Our measurements showed only modest 27 28% peak QEfor these tubes. We have obtained information from Photonis that they succeed to produce a few batches of bialkali PMTs with peak QEvalues well in excess of 30%. We will be looking for an opportunity to measure those PMTs. 5. Coating of PMTs with a milky scattering layer Earlier we have reported on the increase of the QE value of bialkali PMTs from Electron Tubes with hemispherical entrance windows, when they were coated with a milky scattering layer of paraloid [11]. Application of the milky lacquer has increased the QE value of 1 00 PMTs of type ET9116A on 15% in a wide spectral range above 330 nm. We have applied the milky lacquer coating technique on the Hamamatsu hemispherical PMTs, shown in Fig. 2. For control reasons we also coated the PMT #1930 from Electron Tubes (see Fig. 2). The results of QEmeasurements are shown in Fig. 4. Both Hamamatsu PMTs show peak QEof 35% (in the wavelength range 340 390 nm) after coating. The Electron Tubes PMT shows a peak QE of 30% at 390 nm. Comparing the Fig. 4 with the Fig. 2 one may conclude that while we succeeded to increase strongly, as usual [11], the QEfor the Electron Tubes PMT, we could obtain only a modest increase with the Hamamatsu PMTs. It is interesting to note, that while the QEcurves of Hamamatsu PMTs show different shapes for wavelengths below 450 nm (see Fig. 2), they are becoming very similar after coating with a milky layer Fig. 4. The measured QEcurves of two PMTs from Hamamatsu and one from Electron Tubes after coating them with a milky lacquer. All the three tubes are of 1 00 size and have hemispherical input windows. (see Fig. 4). Also, by comparing the PMTs #5043 and #5038 in Figs. 2 and 4 one may notice that the PMT with lower original QEgets stronger enhancement in QEdue to the coating. The relatively low increase of the QEof Hamamatsu PMTs after coating could be due to their low back-reflection of photons from the photo cathode. 6. Conclusions In the last couple of years we were working with the PMT manufacturers Hamamatsu, Electron Tubes and Photonis on increasing the QEof 1 2 00 bialkali PMTs. We can report that all the three companies succeeded to produce PMTs with enhanced QE. Especially successful is Hamamatsu who could produce PMTs with QEin excess of 32 33%. When applying the milky lacquer coating technique to few Hamamatsu PMTs we could obtain peak QEvalues of 35%. It seems that for producing bialkali PMTs with enhanced QEthe manufacturers are using technologies that are not much different from the usual ones. Correspondingly their cost shall not differ much from the usual ones. References [1] J. Elster, H. Geitel, Ann. Physik. 38 (1889) 497. [2] A. Einstaein, Ann. Physik. 17 (1905) 132. [3] R. Pohl, Pringsheim, Verhandl. Deut. Physik. Ges. 12 (1910) 1039. [4] K.H. Kingdon, I. Langmuir, Phys. Rev. 21 (1923) 380.

R. Mirzoyan et al. / Nuclear Instruments and Methods in Physics Research A 572 (2007) 449 453 453 [5] L.R. Koller, Phys. Rev. 36 (1930) 1639. [6] N.R. Campbell, Philos. Mag. 12 (1931) 173. [7] P. Görlich, Z. Physik. 101 (1936) 335. [8] N.W. Wainfan, et al., J. Appl. Phys. 24 (1953) 1318. [9] A.H. Sommer, Photoemissive Materials, Wiley, 1968. [10] R. Mirzoyan, et al., Nucl. Instr. and Meth. A 567 (2006) 230 232. [11] D. Paneque, et al., Nucl. Instr. and Meth. A NS-504 (2003) 109.