METERSUK. HE203e METER. Installation Data ELECTRIC 3 PHASE ELECTRIC COMPONENTS :

Similar documents
Telemetry Receiver Installation Guide

Telemetry Receiver Installation Guide

7 Day Digital Light Switch with Optional Dusk Start

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

Additional Instructions for the Arlec Energy Cost Meter PC222

SceneStyle2 User Guide

Trio II Touch Button. Your new In-Home Display: a handy guide to what it is and how it works.

OPERATION AND MAINTENANCE

EDL8 Race Dash Manual Engine Management Systems

OWL micro+ WIRELESS ELECTRICITY MONITOR

multi-function meters

ATTENTION YOUR NEW KEY FOBS WILL NOT WORK UNTIL YOU HAVE LOADED THEM ON TO YOUR REMOTE CONTROL SYSTEM

QUIZ BUZZER KIT TEACHING RESOURCES. Version 2.0 WHO ANSWERED FIRST? FIND OUT WITH THIS

Safety FIND THE FEED CABLE IN YOUR ELECTRICITY METER (UK)

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions

1. General Information:

How to read your meter. A guide to ensuring an accurate bill

Master Time Clock MTC Users Manual

ET BLU MIX RX-Condo-3

EDMI Mk 7C Electricity Meter User Guide to LCD Screen Displays

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

A summary of all menu lines available in self-diagnostic mode is shown below.

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

Part names (continued) Remote control

FD Trinitron Colour Television

DCD-24 Word Clock Distributor

HS-509 VIBRATION TRIP MODULE

BBV REAL TIME HQ DISPLAY QUAD MANUAL


GAUGEMASTER PRODIGY EXPRESS

2-output DALI controller

Sprite TL Quick Start Guide

Digital Economy Seven Programmer

EC7000, EC7004 and EC7005 Single Channel Electronic Time Controls

Certificate of Calibration

PowerLogic power-monitoring units

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

Identification - electrical services

Troubleshooting CS800/LC900 Bikes

Active UTP Transceiver Hub Installation Guide

Aspect 2 Circuit Digital Scene Control

Single Axis Position Controller

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

PREAMPLIFIER INTRODUCTION INSTRUCTIONS FOR USE. Thank you for purchasing the Musical Fidelity A3 CR remote control preamplifier.

MANUAL ENGLISH Core Club Ordercode: D2314

Synchronization Check Relay ARGUS 7

Master Clock Controller. User Guide. pyramidtimesystems.com

Master Clock Controller. User Guide. pyramidtimesystems.com

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

Getting started with

Computer Systems Architecture

Nixie Clock Type Frank 2 Z570M

K9123, K9134, K9135 Remote Programming Instructions and Specifications

High Speed Counter. Table of Contents

Master Clock Controller. User Guide. pyramidtimesystems.com

Dissolve Control Programming : Projector/Dissolve Control Hook-Up

MATE3 Owner s Manual Addendum

COHERENCE ONE PREAMPLIFIER

Bulletin 190 IEC Modular Starter System

Series CT7N Bimetallic Overload Relays

Toronto Hydro - Electric System

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

INSTRUCTIONS FOR USE Pro-Ject Receiver Box S

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

21 Channel Light Show PWM LED Controller with Remote Control

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

YLAA YLAA0175 AIR-COOLED SCROLL CHILLERS STYLE A, B or C (60 Hz) TON KW

Operating instructions Electronic preset counter Type series 717

IL591 SECTION D Rev /2011. Tek-SAFE NC150R Area of Rescue Assistance System. Operation, Installation and Service Manual

INTEGRATED AMPLIFIER INSTRUCTIONS FOR USE

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

HDMI Over Mains Power with IR AR-1903 User Manual

USER GUIDE for the. HES92020, HES92021, HES92220 & HES92221 DIMMER Modules

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

THE FROG SERIES OPERATING MANUAL

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

TFT-LCD TV USER MANUAL W102T READ CAREFULLY BEFORE OPERATION W102T

RECT-STx-XXX and RECT-STx13-XXX Triple Lamp Operational and Programming Instructions

Limited warranty. Conditions

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

RADIO RECEIVER RGB CONTROLLING LED COMMON KATHODE

TESTCAT. User Manual. Structured Cable Tester. Issue 1.1

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

THERMIONIC CULTURE. TheEarlybird 2.2. valve microphone pre-amplifier OPERATING MANUAL

AH-PMP-1DA & AH-1DA Operator's Manual

7 Day Digital Time Switch

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown then fax: 44 (0)

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

7 SEGMENT LED DISPLAY KIT

NIGHT WATCHER NW 760 QUICK SETUP GUIDE

TECHNICAL MANUAL. Operating and Maintenance Instructions for

RD-1 ROBERTS. FM /DAB digital radio with. Sound for Generations. Gemini 1. Please read this manual before use

LDG TW-2 Talking Wattmeter For VHF and UHF

PRINCIPLES AND APPLICATIONS

1782 Two-Line Digital Answering System with Caller ID/Call Waiting

Binary s UFO Inventors Manual

Transcription:

Installation Data sales@meters.co.uk 01524 555 929 ELECTRIC 3 PHASE e P L E A S E RREE AADD T H E I N S T R U C T I O N S ELECTRIC Settings 400 Pulses = 1 kwh The kwh is shown on your electricity invoice. METERS UK LIMITED CANNOT ACCEPT ANY LIABILITY FOR ANY SETTINGS OR CHARGES MADE ELECTRIC COMPONENTS : e rev Dynamite Range IEC62053-21 :2016 0)A 50/60Hz 3x230/400V 3x10(10 000375.5 e 17 x 1625 000123456789 1. Three Phase Meter 2. The Card Reader 3. The Contactor PLEASE NOTE - ALL above items must be connected as per Schematic in order for system to work

Installation Data 3 Phase Prepayment Wiring Schematic 16x 1342 - LIVE OUT NEUTRAL OUT NEUTRAL IN LIVE IN LOAD + 24 23 PULSE COIL rev 000735.1 Dynamite Range IEC62053-21 :2016 0)A 50/60Hz 3x230/400V 3x10(10 000123456789 1 2 3 4 5 SUPPLY 6 7 N

INSTRUCTIONS PROGRAMMING The product is designed to offer the operator and customer maximum functionality benefits to ensure optimum operation. Please adhere to the programming instructions methodically. DEFAULT DISPLAY MODE When a live electrical connection is made, but the unit is not programmed, the display will always show the default mode of CARD VALUE Card Value ORANGE BUTTON SCROLLS DOWN BLUE BUTTON ACCEPT/OK SCREEN 1 - CARD VALUE The card has two sides. This screen is where the value of each side is programmed. The value is in pennies ( ) or cents (Euro). A 5 card would be programmed with 2.50 each side of the card. Double sided card - use both edges ie. A 10 card has 5.00 each side. Therefore 500 would be programmed in 500 + 500 = 1000 ( 10) SCREEN 2 - WARNING BUZZER The warning buzzer is used to alert the user that the time is coming to an end and the facility will be switched off. If this feature is not required program 0000. Use the BLUE Warn Value 0000 BUTTON to skip the digits. Once the selection has been accepted the next screen will come up automatically SCREEN 3 - PULSE MULTIPLIER This is the pulse value of the Electricity Meter - EM735 Enter 400 This is what the screen would look like 400 Pulses 400

SCREEN 4 - UTILITY VALUE This will be the value per pulse of the electricity. This is what you physically pay. This should be found on your electricity bill. If you are unsure of the amount you pay please contact your utilities provider as Meters UK cannot advise you on what to enter. The cost of Kwh of Electric 016.0 008.2 This is what the screen would look like if your electric was 16p or 16c This is what the screen would look like if your electric was 8.2p or 8.2c SCREEN 5 - EMERGENCY CREDIT When the full amount credited to the meter has been used up, the Emergency Credit facility will be available for you to use. The emergency credit amount is not fixed and can be set at any amount. In the event this facility is not required, program 0000 ie. 10 = 0000 1000.0 This is what the screen would look like 10.00 SCREEN 6 - SETTINGS CHECK The system now scrolls through the settings which have been programmed. Settings Check IT IS VERY IMPORTANT TO DOUBLE CHECK THESE SETTINGS, as once set can only be changed with a Zapper Tool. SCREEN 7 - REJECT SETTINGS After the settings have been checked the program automatically moves into Reject Settings. If you are unsure that the settings are anything but 101% correct, press the BLUE BUTTON Reject Settings to reject the settings entered and re-insert your settings. Only if you are happy with the settings would you scroll ORANGE BUTTON to the next screen ACCEPT settings. SCREEN 8 - ACCEPT SETTINGS If you are 100% happy with the settings entered, then press and hold the BLUE BUTTON. Hold for 10 seconds. There will be a continuous beeping sound whilst all the settings are being saved. Accept Settings Once saved the screen will default back to the CREDIT or screen.

CARD * PREPAYMENT * GAS INSERTING CARDS Insert each side of the card fully - sharply - remove from the card reader If the card does not activate - Remove from the card reader and give the e approx. 30 seconds to reset and try again. When a credit has been accepted, the card will be crimped on removal from the card reader. At zero credit the He203 closes an internal contactor (between the live terminals). The contactor is rated at 100Amps, 230v-50Htz TO RESET THE METER In the event of a power cut or if the circuit trips the meter will need to be reset. Before resetting the meter please ensure that all stoves or other gas utilities are switched off. Press and hold the BLUE or GREY button on the meter to restart/reset the meter. To confirm that the meter has been reset the display will show CREDIT 000 and the meter will function as normal. CHANGE SETTINGS Settings can only be changed with the ZAPPER RESET TOOL. The tool can only be purchased from Meters UK Ltd. Zapper reset tools will only be sold to landlords or owners. Reset Window 16x 1342 Zapper Reset Tool Once the Zapper Tool has been purchased point the front of the zapper directly at the reset window next to the red button on the meter. Press and hold the button on the Zapper, once the remote connects to the meter the display will show OVERRIDE, you can now start to reset the meter to your desired settings. For more information on the instructions please request a Zapper Tool instruction guide. METER CARD ERROR If the meter does not accept your card it may mean that the card reader heads need cleaning. Use METHYLATED SPIRITS on the reverse side of the card and insert twice with the blank side facing upwards. You can obtain the spirit from various outlets. Please do not use any other spirit. sales@meters.co.uk White Lund Industrial Estate Lancaster LA3 3BT 01524 555 929