WVS6131/S6111 Release Note 1.10 July, '17 1.12 Sept., '17 1.13 Oct., '17 Ver1.70 Nov.,'17 A B U Issue (Phenomenon) Occurrence condition Aborted video transmission in multicast transmission. When On is selected for Stabilizer. amera picture may be solid black. Tilt's coordinates were reversed for ceiling and tabletop installations. : Maintenance timing First production. For WVS6131H only Missing display the "VMD / ivmd" column in ivmd "Alarm". For WVS6111 only In Spanish only. The alert message shows "360 or more". For WVS6111 only When setting ivmd depth, after drawing and registered rectangle, the coordinates of the rectangle would be shifted in the upper left direction when the screen was redisplayed. At displaying system log, display the log in two lines. Also display shifting the date and time of occurrence and contents column each other. This document describes software package upgrade for WVS6131/S6111. In case outputting log with a long character string. ontents Panasonic orporation Profile S compliant service on ONVIF, made available for streaming in H.265 settings. Added a message in the setting screen for SD memory card; "It is not available when "60fps" is selected for [Image capture mode]." hanged the hue etc. even if only the brightness were changed. orrected to be "180 or more". orrespondence Added a support page and so that it possible to access to support page by QR code. RTSP distribution abolished the constraint which was only unicast while selecting multicast. In GI command, epanded the parameter of "get_io2". Added response format "3" so that information on sound detection / command alarm / ivmd could be acquired. In ONVIF, improved accuracy of PTZ value up to 5 decimal places. Added a message; When using Image capture size of 20481536, QVGA, 320180, the digital zoom may be canceled at 360 or more. As a result of cancelling the digital zoom, camera picture may be distorted. amera may reboot by changing image capture mode. When use with recorder. 1/5 S6131_013
WVS6131/S6111 Release Note : Maintenance timing This document describes software package upgrade for WVS6131/S6111. A B U Issue (Phenomenon) Occurrence condition amera may reboot by accessing with a browser other than Internet Eplorer (IE). ontents Deleted encryption protocol TLS 1.0 for security purpose. Panasonic orporation orrespondence Improved Auto Focus speed at normal brightness and low light intensity. Ver1.70 Nov.,'17 Ver1.80 Dec.,'17 Ver1.81 Feb.,'18 Ver1.82 Mar.,'18 Ver1.83 Apr.,'18 orrected on May22,2018 1.90 June, '18 RTSP connection may be disconnected upon receiving an incorrect RTSP request. RSTP connection may be disconnected very rarely by sending RTSP request reception and RTSP response transmission at the same time. U Upgrading firmware might fail. The specified image capture size may not be obtained even if it were specified with ImageViewer by GI command. Administrator password may be deleted. "Additional info for detecting alteration" might not displayed on SD memory card security settings. The stabilizer might not effect. Improved optical zoom speed. Improved for the image at the high luminance part not to saturate over when Super Dynamic "On". Improved communication quality on video streaming in H.265/H.264. Fied an issue in the cgi command "/Set?Func=Bright&Kind=1&Data=2" Improved autofocus during manual zooming. Improved auto focus convergence speed quicker. Improved stabilizer to be more effective when it was used for a long time. hanged factory default setting for Authentication method; Previous: "Digest or Basic" New: "Digest" For more details: For more details: security_upgrade_june2018.pdf hanged password policy that it must include at least 3 types of characters among "upper case letters / lower case letters / numbers / symbols". For more details, click here. Note: Original passwords and authentication method of products on the system are kept unchanged even firmware and software have been updated. Added user authentication at host authentication. security_upgrade_june2018.pdf 2/5 S6131_013
WVS6131/S6111 Release Note : Maintenance timing This document describes software package upgrade for WVS6131/S6111. A B U Issue (Phenomenon) Occurrence condition Ecept hinese market model, WVS6131H. ontents Became saving history of login failure into system log. Panasonic orporation orrespondence hanged saving setting data with encryption. Note: unable to restore the setting data if you would downgrade the firmware. Made some other security measures enhanced. Ecept hinese market model, WVS6131H. Added "EAPTLS" to the EAP method for IEEE802.1. Added "Drawing method", "Decoding options" and "Frame Skip Options (When P is Heavy Processing Load)" onto plugin software. Added "Reboot" to "Schedule". Added a choice of "2pics/2s" for "Transmission interval" setting of "Transmission mode" in "Best shot function". Note: oncerning the models on this document, the models are NOT recommended to use the Best shot function. 1.90 June, '18 ommunication may be disconnected when acquiring network information with SNMP. hanged factory default setting for "Bandwidth control(bit rate)" Previous: Unlimited New: 51200kbps Network connection may not be possible due to the MA address authentication with the network device may not be done properly at startup. Temperature compensation at lens may not work correctly and the focus sometimes shifts little by little. Unable to configure the setting relating to the email notification by the cgi command "reg_mailaddr". Focusing may not work. If an RTSP header contains two or more UserAgent headers. no HTTP400(Bad Request) error returned and ignore the second and subsequent UserAgentheaders. Added on July 27,2018 It was usable even if the certificate for using HTTPS has epired. 1.91 July, '18 Solid black screen may be appear during sequencing with the network disk recorder due to it takes time to output the video. 3/5 S6131_013
WVS6131/S6111 Release Note 1.91 July, '18 : Maintenance timing This document describes software package upgrade for WVS6131/S6111. A B U Issue (Phenomenon) Occurrence condition SD memory backup recording did not stop. amera may reboot, unepectedly. Revised on Sept. 7, 2018 Recording may not retain when restarting camera. Recording may not stop at restoration of communication Did not work Hardware decode of plugin software may not work when selecting compression method "H.265". ontents By turning power on / off while SD memory backup recording during connecting with the network disk recorder. When sequencing the network disk recorder and or the video management software (WVASM series) with "SD memory backup" enabled simultaneously. By downloading the SD memory backed up data with the network disk recorder In an environment where the communication state is unstable Panasonic orporation orrespondence 1.92 Aug., '18 Frame rate and bit rate may drop. May not be able to zoom in with multiscreen display by dragging with mouse. By transmitting H.264/H.265/JPEG live images continuously over 1 year without being rebooted. amera may restart by disconnecting the camera's LAN cable while transmitting video in UDP. In A power operation. Picture may not be displayed according to the frame rate. (Occurrence frequency : Rare) When Image quality to be set in Motion priority (Frame rate). 1.93 Oct., '18 The frame rate may be temporarily decreased. (Occurrence frequency : Rare) The operation speed may slow down and the followability may be decreased. During the pan/tilt operation. Operating speed may be slowed. During the manual zooming. Focus may shift out. In an outdoor low light environment 1.94 Nov., '18 Ver2.00 Dec.,'18 ONVIF RTSP Multicast may not be transmitted. Multicast related settings ("Transmission type" setting and some others) may restore to the factory default settings by upgrading firmware from version 1.82 (or earlier) to version 1.90 (or later). amera may restart, unepectedly. (Occurrence frequency: Rare) In case of high load such as multistream transmission at 60fps etc. Improved detection capability of "face wearing a mask" at detecting face by Facial Recognition Server Software, WVASF950, etc. Note: Not recommended product for Face best shot function. Settings of "HTTP ma segment size(mss)" to be relating to the camera action; JPEG transmission for Face Best Shot "HTTP alarm notification" By receiving ONVIF command continuously. 4/5 S6131_013
WVS6131/S6111 Release Note Ver2.00 Dec.,'18 A B U Issue (Phenomenon) Occurrence condition : Maintenance timing amera may send corrupt AAL data. Video distribution may not be possible. ommunication error may occur. (Occurrence frequency: Rare) This document describes software package upgrade for WVS6131/S6111. ontents When the transmission is delayed due to the network environment etc. When the configuration of UI setting for Baseline Profile were as follow; 30fps, H.264, FHD, Other than VBR While connecting with Network Disk Recorder, WJ NX series. Panasonic orporation orrespondence 5/5 S6131_013