Close supervision. Simplicity of use. Productivity gains. Control relay. C-Lynx. Instinctive control

Similar documents
Micro-control. Control system solutions adapted to your applications. Overview. b Logic controllers. b Control relays. b Timers.

Control & Automation Overview. Behind every project, technologies and expertise. Timers. Control relays. Counters and Ratemeters

02/11/2015

Micro-control. Control system solutions adapted to your applications. b Logic controllers.

G1-M1 (Protection Relay)

PRINCIPLES AND APPLICATIONS

IP Roombox. Hotel Room Management

KRF EMC Filters Installation, Operation and Maintenance Manual

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

AF-300 E11 Adjustable Frequency Drive

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

15 Series - Dimmer

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Bulletin 190 IEC Modular Starter System

Grid feeding monitoring according to VDE-AR-N 4105 and BDEW CM-UFD.M31

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

Gamma instabus. Technical product information

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Assembly. Front view. LEDs. Parametrization interface. Power Bus

2-output DALI controller

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

BE3-GPR GENERATOR PROTECTIVE RELAY

Capacitance Limit Detection nivotester FTC 420/421/422

Electronic timers CT-range Measuring and monitoring relays CM-range

CAMTO LTD. Arc detecting system DC/AC

SOFT STARTER. We are delivering Real Cost Benefits CD AUTOMATION POWERED BY INNOVATION. Soft Starter Catalog 2018 Release n.

USER MANUAL Full HD Widescreen LED Monitor L215ADS

Series description: Wilo-Sub TWU 3 HS

USER MANUAL Full HD Widescreen LED Monitor L215IPS

High performance circuit breakers

DLP200M 2 Relay Module for Heating and Cooling Plants

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

KHT 1000C HV-Probe Calibrator. Instruction Manual

Figure 1: Device components

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Simply clever! The digital DIN-rail time switches by Grässlin

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

Siemens AG Safety along the complete line: SIRIUS 3SE7 cable-operated switches SIRIUS. Answers for industry.

Generator protection relay

LED Driver Compact dimming

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Digital Input Modules for Compact FieldPoint

SC26 Magnetic Field Cancelling System

A. Introduction 1. Title: Automatic Underfrequency Load Shedding Requirements

ABB CM-UFD.M31 monitoring datasheet

QTi DALI 2X14/24/ DIM

DLP600M 6+1 Relay Module for Heating and Cooling Plants

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

Multi-functional safety relay modules PROTECT SRB-E

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

TRF STEP-DOWN TRANSFORMER USER MANUAL

RYKO Italia s.r.l. V. Casale Morano Po (Al) t f

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

GP-500 SERIES - Low Voltage

LED Driver Constant voltage

Is Now Part of To learn more about ON Semiconductor, please visit our website at

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

LED Driver Linear / area dimming

FOREST SHUTTLE S / L / M RECEIVER

Atlas SCR. User Guide. Thyristor and Triac Analyser Model SCR100

LED Driver Compact fixed output

LED Driver Compact dimming

Catalogue Ignitors and power switches for HID

Litile34 OPERATION MANUAL

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Maintenance/ Discontinued

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Circuit-Breakers for Motor Protection Series 8523/8

E-VENT. The turnkey plasma cutting machine. Technica l progress in the design

TECHNICAL MANUAL. Operating and Maintenance Instructions for

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Maintenance/ Discontinued

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

BE1-81O/U Frequency Protection. Washington State University Hands-On Relay School.

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

R&S BBL200 Broadband Amplifier Specifications

User Guide Stand-Alone Metering for OptiPlant

ADJUSTABLE SPEED DRIVES. nc1 Drive

Standard RS232 RS ma

Automatic Transfer Switch Control PLC Operator s Manual

Process transmitter RMA422

MAP110 AC-DC Series Data Sheet

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Capacitors and banks 50 Hz 0 400/415 V network voltage

HID control gear Electronic


TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

LED Driver Compact dimming

DIN Power Module - Phase Adaptive

LED Driver Compact dimming

PHASED OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM chronostep PCI outdoor

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Process Transmitter RMA 422

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Transcription:

Close supervision Simplicity of use Productivity gains Control relay C-Lynx Instinctive control

C-Lynx Control relay 1 Close-up protection for total availability of equipment! By installing a control relay, the user can be informed of abnormal operating conditions, and is therefore able to take the necessary action to correct the fault by stopping the machine briefly before expensive breakdowns occur. 3 good reasons for installing A major challenge for industry is to improve the availability of production tools, for which the close supervision and protection offered by C-Lynx is the perfect solution. It therefore makes sense for every device to be monitored by a C-Lynx control relay. Each device or machine would therefore be able to complete its allotted task at the appropriate time. MWA HHZ

a control relay in your equipment 3 All anomalies are detected! Control relays monitor and detect abnormal operating conditions of an electrical or physical value (voltage, current, phase, level) in any device, even the most specialised (hoist, machine, motor, conveyor, etc). If an anomaly is detected, the control relays emit a visible signal and trigger a change in the output contacts. 3 4 Optimise continuity of service In industrial and commercial installations, every device should be monitored by a C-Lynx control relay so as to optimise continuity of service. The control relay enables the operator to initiate maintenance operations or corrective actions to avoid production shutdowns. Result: Improved operation and productivity for your installation! By using control relays, you optimise your production management and reduce incidents which could adversely affect your productivity. 3

C-Lynx Control relay Supervision of motors, lifts, hoists, conveyor belts, packaging and air extraction, pumping... from standard products to bespoke products, C-Lynx control relays adapt to a multitude of applications, to meet all your requirements. C-Lynx, control relays dedicated 1 Supervision of Motors On 3-phase supplies, C-Lynx control relays check phase sequence and phase failure preventing a change in direction of rotation, and single-phase operating modes. They therefore avoid overheating faults linked to phase imbalance. 3 Temperature control in lifts C-Lynx temperature control relays monitor the ambient temperature of service rooms or lift pulley rooms, to check that it remains with the statutory limits (between 4 C and 40 C) in compliance with standard EN 81. 3 4 HVAC Heating, cooling, air conditioning or extraction... C-Lynx control relays stop the motor to protect the unit in the event of current, phase and/or supply voltage faults. Lifts HWT81 Air conditioning units 4

to your applications 4 5 Pump and level control Agricultural applications, watering, irrigation, drying, pressure surge, lift pumps and fire pumps, distribution and treatment of water, etc. C-Lynx control relays are used to manage and protect equipment by current measurement and phase monitoring. C-Lynx control relays can also be used to control emptying and filling levels. Pumps 5 6 Load monitoring Conveying, packaging, assembly or bottling lines, grinders, crushers, etc. C-Lynx control relays monitor overloads on driving motors and detect any jamming. 5 6 Speed monitoring Whatever the application, C-Lynx control relays react and alert the operator if the machine operating rate is abnormally high or low. Conveyors Escalators MWG C-Lynx control relays can adapt to both standard and specialist applications. 5

C-Lynx Control relay 1 The strong points of C-Lynx The combination of several functions in the same housing optimises your wiring time and simplifies installation. The new 17.5 mm modular format considerably reduces the dimensions of your equipment. The Easy to use function: the visual LED interface informs you of operating faults in your installation and any errors made when setting the parameters. The new-generation built-in multivoltage power supplies optimise the number of parts and simplify product selection. Eco-design: C-Lynx control relays have been developed in accordance with the principles of eco-design (choice of materials, manufacturing process, energy consumption and component recycling). The recycling rate for these control relays is higher than that imposed by the WEEE (Waste Electrical and Electronic Equipment) European directive. C-Lynx, tous les sens en éveil pour C-Lynx control relays comply with all the required electrical standards and are easily integrated in your electrical equipment. Operating mode Threshold Hysteresis Power supply status Relay output status Time delay MUS 6

s adapter à vos équipements Custom able label Crouzet can satisfy all your automation requirements, from custom components to the most dedicated product. Throughout the world Crouzet provides technical and industrial expertise to ensure that its products are perfectly customised and adapted for integration in any of your equipment. This is why Crouzet guarantees customisation or adaptation of the whole range of C-Lynx control relays. 3 Adaptability: C-Lynx s trump card The Crouzet design office can create control relays tailored to suit your needs, based on your specification. Crouzet offers you the following adaptations: Adaptation of the level of regeneration for phase failure checks, Conversion of adjustable products into products with a fixed threshold, Adaptation of input voltage ranges and measurement ranges, Modification of timing ranges and addition of fixed values, etc, Possibility of customising colours and labelling, etc. Ease of reading Simplified connections 7

C-Lynx Control relay 1 New features of the C-Lynx range Positive logic output also indicating loss of power supply, True RMS measurement: even if the sine waves are distorted, the measurement is correct, Reduction in the number of housing sizes: with a 17.5 mm and 35 mm modular compact format, C-Lynx control relays can be integrated more easily in industrial and commercial cabinets, Built-in universal power supplies: a version with power supply for single-phase products and a self-powered version for 3-phase products, Adjustable time delay on crossing thresholds, thus avoiding transient faults, Settings can be protected by fitting a sealable cover, Very clear display of control status via LEDs. C-Lynx by Crouzet: a complete collection of H3US MUSF HIH HHZ HPC MNS 8

control relays 3 A complete range of standard control relays To satisfy all your automation requirements, Crouzet offers you an extensive range of standard control relays. Phase control relays (MWS, MWS, MWG, MWU, MWA, MWUA, HWUA, H3US, H3USN, M3US) : - presence and regeneration, phase sequence, phase, balance and level of asymmetry (or balance), - adjustment of voltage thresholds. Voltage control relays (MUS, MUSF, HUL, HUH) : - overvoltage, undervoltage control, - self-powered versions. Current control relays (MIC, HIL, HIH) : - overcurrent and undercurrent control, - version with built-in toroid. Frequency control relays (HHZ) : - Overfrequency and underfrequency control of the 50 or 60 Hz AC signal. Pump control relays (HPC) : - control of single-phase or 3-phase pumps, - dry run and overload protection, - 3-phase control. Level control relays (HNM, MNS, HNE) : - automation of filling and emptying cycles, - high or low level information, - check for presence of a conductive or non-conductive liquid by temperature probe or discrete sensor. Speed control relays (HSV) : - monitoring of pulse rates, - overspeed and underspeed control, rotation or movement control. Lift temperature control relay (HT81, HT81-, HWT81) : - temperature monitoring in machine rooms and lift pulley rooms in accordance with standard EN 81, - version with built-in phase control, - phase failure with regeneration up to 70%. Phase and temperature control relays (HWTM, HWTM) : - 3-phase network control, - motor temperature control with PTC probe test and memory function on temperature control. HSV HT 81 9

C-Lynx Control relay Selection guide Designation Part number Description Operating conditions Phase control MWS 8487300 Phase failure and phase sequence MWS 8487301 Phase failure and phase sequence MWG 848730 Phase failure and phase sequence Regeneration 70% of Un MWU 8487303 Phase failure and phase sequence Regeneration 70% of Un Undervoltage 08/0/380/400/415/440/480 V AC MWA 8487304 Phase failure and phase sequence Regeneration 70% of Un Asymmetry MWUA 8487305 Overvoltage/undervoltage (window) Asymmetry HWUA 8487306 Overvoltage Phase failure and phase sequence Asymmetry Undervoltage H3US 848730 Phase failure Phase failure and phase sequence Undervoltage Overvoltage H3USN 848731 Loss of phase and neutral Undervoltage Overvoltage M3US 84873 Phase failure Undervoltage Overvoltage 08/0/380/400/415/440/480 V AC 0/380/400/415/440/480 V AC 0/380/400/415/440/480 V AC 0/380/400/415/440/480 V AC 0/380/400/415/440/480 V AC Phase/neutral Un: 10/17/0/30/40/60/77 V AC Phase/neutral Un: 10/17/0/30/40/60/77 V AC 08/0/380/400/415/440/480 V AC 08/0/380/400/415/440/480 V AC Voltage control MUS1DC 8487140 Undervoltage or overvoltage MUS80ACDC 8487141 Undervoltage or overvoltage MUS60ACDC 848714 Undervoltage or overvoltage MUSF80ACDC 8487151 Overvoltage/undervoltage (window) MUSF60ACDC 848715 Overvoltage/undervoltage (window) HUL 848710 Undervoltage or overvoltage HUH 8487130 Undervoltage or overvoltage Current control MIC 848711 Undercurrent Via built-in Toroid HIL 8487110 Undercurrent or overcurrent HIH 84871130 Undercurrent or overcurrent 10

Control values Supply voltage Time delay Output relay 08-480 V AC 50/60 Hz Self-powered 08-480 V AC 1 single changeover relay 5 A 08-440 V AC 50/60 Hz Self-powered 08-440 V AC single changeover relay 5 A 08-480 V AC 50/60 Hz Self-powered 08-480 V AC 1 single changeover relay 5 A 08-480 V AC 50/60 Hz -0% to -% 08-480 V AC 50/60 Hz 5% to 15% -0% to -% +% to +0% 5% to 15% 08-480 V AC 50/60 Hz +% to +0% Self-powered 08-480 V AC 0.1 s to 10 s 1 single changeover relay 5 A Self-powered 08-480 V AC 0.1 s to 10 s 1 single changeover relay 5 A Self-powered 08-480 V AC 0.1 s to 10 s 1 single changeover relay 5 A 5% to 15% -0% to -% 0-480 V AC 50/60 Hz 0-480 V AC 50/60 Hz -0% to -% +% to +0% 10-77 V AC 50/60 Hz -0% to -% +% to + 0% 08-480 V AC 50/60 Hz -0% to -% +% to +0% Self-powered 0-480 V AC 0.1 s to 10 s 1 double changeover relay x 5 A Self-powered 0-480 V AC 0.3 s to 30 s single changeover relay 5 A Self-powered 10-77 V AC 0.3 s to 30 s single changeover relay 5 A Self-powered 08-480 V AC 0.3 s to 30 s 1 single changeover relay 5 A 9-15 V DC Self-powered 1 V DC 0.1 s to 10 s 1 single changeover relay 5 A 0-80 V AC/DC Self-powered 4-48 V AC/DC 0.1 s to 10 s 1 single changeover relay 5 A 65-60 V AC/DC Self-powered 110-40 V AC/DC 0.1 s to 10 s 1 single changeover relay 5 A 0-80 V AC/DC Self-powered 4-48 V AC/DC 0.1 s to 10 s 1 single changeover relay 5 A 65-60 V AC/DC Self-powered 110-40 V AC/DC 0.1 s to 10 s 1 single changeover relay 5 A 0. V to V 1 V to 10 V 4-40 V AC/DC 50/60 Hz 0.1 s to 3 s 1 double changeover relay x 5 A 6 V to 60 V 15 V to 150 V 30 V to 300 V 60 V to 600 V 4-40 V AC/DC 50/60 Hz 0.1 s to 3 s 1 double changeover relay x 5 A A to 0 A 4-40 V AC/DC 50/60 Hz 1 single changeover relay 5 A ma to 0 ma 10 ma to 100 ma 4-40 V AC/DC 50/60 Hz 0.1 s to 3 s 1 double changeover relay x 5 A 50 ma to 500 ma 0.1 A to 1 A 0.5 A to 5 A 1 A to 10 A 4-40 V AC/DC 50/60 Hz 0.1 s to 3 s 1 double changeover relay x 5 A 11

C-Lynx Control relay Selection guide Designation Part number Description Operating conditions Frequency control HHZ 8487501 Underfrequency and overfrequency (window) 50 Hz or 60 Hz Level control HNM 84870700 Filling or emptying with conductive liquids 1 or levels MNS 8487070 Filling HNE 84870710 Filling or emptying 1 or levels Speed control HSV 8487430 Underspeed or overspeed Temperature control in lifts according to EN 81 HT81 84874110 Undertemperature and overtemperature (window) HT81-8487410 Undertemperature and overtemperature (window) HWT81 84874130 Undertemperature and overtemperature (window) Phase failure and phase sequence Regeneration 70% of Un Pump and level control HPC 8487400 Network monitoring 1 phase 3-phase: Phase failure and phase sequence Undercurrent and overcurrent (window) Temperature and phase control HWTM 8487307 Phase failure and phase sequence Thermal protection HWTM 8487308 Phase failure and phase sequence Thermal protection Test Memory Reset on front panel via pushbutton and remotely Reset on front panel via pushbutton and remotely 1

Control values Supply voltage Time delay Output relay 40 HZ to 60 Hz 50 HZ to 70 Hz 10-77 V AC 50/60 Hz 0.1 s to 10 s single changeover relay 5 A 50 to 5 K 5 K to 100 K 4-40 V AC/DC 50/60 Hz 0.1 s to 5 s 1 double changeover relay x 5 A 50 K to 1 M Contact input for discrete sensor 4-40 V AC/DC 50/60 Hz 0.1 s to 5 s 1 single changeover relay 5 A Input for discrete sensor: Contact/PNP/NPN 4-40 V AC/DC 50/60 Hz 0.1 s to 5 s 1 single changeover relay 5 A Time between controlled pulses: 0.05 s to 0.5 s 0.1 s to 1 s 0.5 s to 5 s 1 s to 10 s 0.1 mn to 1 mn 0.5 mn to 5 mn 1 mn to 10 mn 4-40 V AC/DC 50/60 Hz 0.6 s to 60 s 1 single changeover relay 5 A 3-wire PT100 input Low threshold: -1 C to +11 C 4-40 V AC/DC 50/60 Hz 1 s to 10 s 1 single changeover relay 5 A High threshold: +34 C to +46 C 3-wire PT100 input Low threshold: -1 C to +11 C 4-40 V AC/DC 50/60 Hz 1 s to 10 s single contact relays (NO) 5 A High threshold: +34 C to +46 C 3-wire PT100 input Low threshold: -1 C to +11 C High threshold: +34 C to +46 C 4-40 V AC/DC 50/60 Hz 1 s to 10 s single contact relays (NO) 5 A 08-480 V AC 50/60 Hz 30 V AC 50/60 Hz 08-480 V AC 50/60 Hz Self-powered (1 or 3 phases) 1 s to 60 s on power-up 0.1 s to 10 s on threshold crossing 1 single changeover relay 5 A 1 A to 10 A AC 08-480 V AC 50/60 Hz Thermistor with automatic reset 08-480 V AC 50/60 Hz Thermistance to réarmement automatique 4-40 V AC/DC single contact relays (NO) 5 A 4-40 V AC/DC single contact relays (NO) 5 A 13

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Crouzet: 84870700 84870710 8487110 848711 84871130 848710 8487140 848714 848715 8487501 8487300 848730 8487303 8487304 8487305 8487306 848730 848731 8487430