Instrument Firmware Release Notes

Similar documents
DS1000Z Deep Memory Data Collection Example

Meeting Embedded Design Challenges with Mixed Signal Oscilloscopes

RS232 Decoding (Option)

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

Overview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators

Oscilloscopes, logic analyzers ScopeLogicDAQ

Agilent Technologies. N5106A PXB MIMO Receiver Tester. Error Messages. Agilent Technologies

2016 RIGOL TECHNOLOGIES, INC.

Serial Decode I2C TEN MINUTE TUTORIAL. December 21, 2011

Digital Storage Oscilloscopes 2550 Series

Fluke 190-Series II Firmware Upgrade V11.44

Keysight Truevolt 34465A 6 ½ Digit Multimeter Keysight Truevolt 34470A 7 ½ Digit Multimeter. Firmware Update 2.09 Release Notes

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

SDS1000X-E Series Super Phosphor Oscilloscope. Quick Start

SDS1000C Specifications

MS-32 OSCILLOSCOPE MIXED SIGNAL OPTION. Add 32 Digital Channels to a 4 Channel Oscilloscope

Digital Oscilloscope Waveform Generator DC Power Supply Digital Multimeter Spectrum Analyzer Handheld Oscilloscope Probes & Accessories

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Portable Performance for Debug and Validation

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

DataSheet. SDS1000DL Series Digital Oscilloscope

RIGOL. 快速指南 DSA800 Quick Guide DSA800 系列频谱分析仪. DSA800 Series Spectrum Analyzer RIGOL TECHNOLOGIES, INC. All Rights Reserved.

DS4000 Series Digital Oscilloscope

What is oscilloscope? What an oscilloscope looks like. Oscilloscopes, accessories, applications Ján Šaliga

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

Revision History. SDG2000X Firmware Revision History and Update Instructions

Advanced Skills with Oscilloscopes

LeCroy Digital Oscilloscopes

MS-32. Oscilloscope Mixed Signal Option. Add 32 Digital Channels to a 4 Channel Oscilloscope

The Measurement Tools and What They Do

Linrad On-Screen Controls K1JT

PicoScope 6 Training Manual

SMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest.

Embest DSO2300. Feature. General Description:

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

RIGOL. 快速指南 Quick Guide DSA800 系列频谱分析仪. DSA800 Series Spectrum Analyzer RIGOL Technologies, Inc. All Rights Reserved.

Simple PICTIC Commands

Benefits of the R&S RTO Oscilloscope's Digital Trigger. <Application Note> Products: R&S RTO Digital Oscilloscope

SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

DDA-UG-E Rev E ISSUED: December 1999 ²

ADS1000C, CAL / CML Series

X-Stream DSO Version 3.6 Release Notes

Agilent InfiniiVision 7000 Series Oscilloscopes

Design and Use of a DTV Monitoring System consisting of DVQ(M), DVMD/DVRM and DVRG

Concise NFC Demo Guide using R&S Test Equipment Application Note

Tablet Oscilloscope Quick Guide

imso-104 Manual Revised August 5, 2011

50 MHz Digital Storage Oscilloscope

PB-507. Advanced Analog & Digital Electronic Design Workstation Instruction Manual. Revision: 2/2014

Advanced Test Equipment Rentals ATEC (2832)

RIGOL. Quick Guide DSA800E. DSA800E Series Spectrum Analyzer RIGOL TECHNOLOGIES, INC. All Rights Reserved.

FLEXRAY TRIGGER, DECODE, AND PHYSICAL LAYER TEST

Logic Analyzer Auto Run / Stop Channels / trigger / Measuring Tools Axis control panel Status Display

Tebis application software

SDS 1072/1074CFL / SDS 1102/1104CFL SDS 1202/1204CFL / SDS 1302/1304CFL Digital Storage Oscilloscopes 70MHz / 100MHz / 200MHz /300MHz

DataSheet SDS1000CML Series Digital Oscilloscope

Dynamic re-referencing Microvolt-level measurements with the R&S RTO oscilloscopes

LedSet User s Manual V Official website: 1 /

BME 3512 Biomedical Laboratory Equipment List

Agilent DSO5014A Oscilloscope Tutorial

Dave Jones Design Phone: (607) Lake St., Owego, NY USA

Agilent 6000 Series Oscilloscope Demo Guide

HAMEG. Oscilloscopes. Innovation right from the start. Oscilloscopes

FlexRay Physical Layer Eye-diagram Mask Testing

KRAMER ELECTRONICS LTD. USER MANUAL

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

Beginners How to Test DSO138mini

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

Logic Analysis Basics

Advanced Troubleshooting with Oscilloscopes 9000 Scope Hands-on Labs

Logic Analysis Basics

QPHY-USB3 USB3.0 Serial Data Operator s Manual

h c HUNG CHANG D IBM PC 586, Pcntium Software Drive : Windows 95 Dual Clmnel Sampling per channel : 100 MS/s

ZScope M-Class Digital Storage Oscilloscope Soft Front Panel

Quick Guide Book of Sending and receiving card

4CH/2CH Digital Storage Oscilloscopes

Troubleshooting Your Design with the TDS3000C Series Oscilloscopes

User Manual. GPS-1000B+ series. Digital Oscilloscope V 1.1

25 MHz Digital Storage Oscilloscope

DataSheet SDS1000CFL Series Digital Oscilloscope

4CH/2 CH Digital Storage Oscilloscopes Mixed Signal Oscilloscopes

Digital Oscilloscope. Characterisation, Measurement & Analysis

Low-speed serial buses are used in wide variety of electronics products. Various low-speed buses exist in different

What's the SPO technology?

SPG700 Multiformat Reference Sync Generator Release Notes

Operating Instructions

IP LIVE PRODUCTION UNIT NXL-IP55

Quick Start. SHS1000 Series Handheld Digital Oscilloscope QS03010-E02B 2015 SIGLENT TECHNOLOGIES CO., LTD

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ

AX20. Atlas 19.5" 3G-SDI/HDMI Field and Studio Monitor with 3D LUTs & Scopes. Quick Start Guide. What s Included CHECKED BY

Broadcast A/V Division M-LYNX-702 V.3. Dual 7 LCD Display. User Manual

Broadcast A / V Division M-LYNX-702 V.3. Dual 7 LCD Display. User Manual

User Manual. Digital Oscilloscope V1.9

imso-104 Manual Revised July 19, 2012

Choosing an Oscilloscope

Re:source. Communication Module. SAT Version. Dominating Entertainment. Revox of Switzerland. E2.00

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

Transcription:

odels DS2072, DS2102, DS2202, DS2072A, DS2102A, DS2202A, DS2302A, DS2072A-S, DS2102A-S, DS2202A-S, DS2302A-S, SO2072A, SO2102A, SO2202A, SO2302A, SO2072A-S, SO2102A- S, SO2202A-S, SO2302A-S Version Information Released version: 00.03.04.02.01 Release Date: 12/14/2015 Compatibility Compatible with earlier versions of the hardware Change Log Key: E Enhancements. Changes that add functionality odifications. Changes to improve performance on existing features C Cancellation. Removal of function or capability *Note: Engineering change log is translated from engineering documentation Version:00.03.04.02.01 Instrument Firmware Release Notes Date:2015-12-14 1. Fixed the LA calibration error Version:00.03.04.01.00 Date:2015-10-10 1. Licenses of 28/56 memory depth and advance triggers are normally supported E 2. Fix scope hangup with timebase change 3. Adjusting the EXT trigger range Version:00.03.03.02.06 Date:2015-06-17 1. Added the persistence of XY wave E 2. Added the French language menu E

3. Supporting the license file installed by U DISK E 4. Supporting the decoder of multi-modules license file E 5. The screen ASC format screen data are not corresponding with the real values 6. The position of the Cursor is wrong in the saved snap pictures 7. Improve the stability the LAN interface communication 8. Fixed the wave stop refreshing in slow scan mode for SO serials 9. emory LA wave data can t be saved as CSV format 10. The parallel decoder result can t align with the Clock position 11. The outputs of two Source channels are not equal with each other 12. The Auto operation can t execute the auto AC settings correctly 13. Update the system of SCPI commands 14. odified the result type of :wav:yor? 15. Fixed the data fetching of the decoder Version:00.03.03.01.00 Date:2014-12-25 1. Only Setups data can be saved without UDISK inserted E 2. Fixed the wave jitter by AC trigger couple 3. The channel wave don t show after power on 4. Fixed the bug for invalid measure of trigger s WAIT status 5. The wave cannot be displayed correctly after Auto operation 6. The trigger position is incorrect when the Sample rate is 5k in the Slow mode

7. SPI trigger position is always in the falling edge the clock 8. Some bugs about the address condition of I2C trigger 9. The Nth cannot triggered sometimes 10. The trigger position will be jitter when adjusting the horizontal offset 11. There is a problem about the display of RS232 package decoder 12. odified some SCPI commands 13. The point voltage cannot be set when using soft keyboard in the creation of new Arbitrary waveforms of the source 2 14. The waveform storage cannot be over in the ROLL mode 15. The extremum statistics are still updating in WAIT status 16. The system cannot save picture data when the trigger slope is SINGLE 17. The SCPI command cannot read LA raw data points 18. Update the library of LXI 19. The polarity of the SPI s decoder is wrong 20. The CopyTrig operation in the decoder don t cover the decode s mode 21. The trigger position is not stable when setting the horizontal offset in the SETUP trigger 22. There is an error in printing the wave data 23. Adjust the recording and measure statistics 24. The I2C cannot triggered when the address width is 8bit 25. Remove the holdoff option in the SETUP trigger menu 26. The system should not trigger about the Nth,Delay,Runt, Window,Pattern and Setup when adjusting any parameter of them. 27. The SCPI commands of Source calibration cannot be answered 28. The trigger position is not stable when setting the horizontal offset in

the SETUP trigger 29. There is an error about the result of measure of period VRms and period Area 30. There is an error about the VPP measure when changing the timebase from ROLL to YT 31. The ath wave is in disorder when Zoom is on in the slow scanning mode Version:00.03.01.00.04 Date:2014-08-22 1. The Ultra Station cannot download the wave table data. 2. The loaded wave is wrong when saving in the Scan mode. 3. The official options cannot continue working when the trial options expired 4. There are errors about the measure of different delay and channels orders 5. The power status is changed to default when power on. 6. :TRIG:SPI:DATA command to set the maximum data is not enough 7. The signal cannot be triggered when the duration trigger source are mixed with analog signal and digital signal. 8. The maximum signal rate of CAN bus in trigger is inconsistent with in decoder. 9. There is something wrong while changing vertical scale and probe ratio repeatedly. 10. The signal cannot be triggered when the delay trigger source are mixed with analog signal and digital signal 11. In addition to the lower edge of the external trigger, trigger type brownout restore the previous value, frequency meter

menu confusion 12. Delay measurement locations up and down along the sometimes inaccurate 13. When you exit the analysis mode, LA waveforms for all measurements is invalid 14. Access to other operations as part of IP, instrument response has been slow and even crash 15. Fixed the crash issue of using "AUTO" function in decode mode. End of Change Log History For more information in North America, please go to rigolna.com, contact us directly at techsupport@rigol.com or call us toll free at 877-4-RIGOL-1. Rigol Technologies USA 10200 SW Allen Blvd, Suite C Beaverton, OR 97005 877.474.4651 For more information in Europe, please go to rigol.eu, contact us directly at applicationseurope@rigoltech.com or call us +49 89 89 41 895-0. Rigol Technologies EU GmbH Lindberghstr. 4 82178 Puchheim, Germany +49 89 89 41 895-0