User Manual. SCR Multiswitch Ref. 9744SKY, 9746SKY, 9748SKY

Similar documents
User Manual. dcss/dscr Multiswitch 9732

User Manual. dcss/dscr Multiswitch 9733PL 9734PL

User Manual. HDMI Modulator Ref & SW Release

DMOD1200MS. HDMI Modulator. User Manual PLEASE READ THE MANUAL COMPLETELY BEFORE USE V.17.09

User Guide. TMDS 5x C Digital SCR Multiswitch for SkyQ. Version B Date 02/2016 EN TMDS 54 C TMDS 58 C

UK. Multi Channel Programmable Filter-Equalizer. User Manual FEATURES. - Designed for both digital and analogue channels,

User Manual. Profiler Revolution Ref PATENT PENDING. SW Version 1.3.0

user manual Colosseum 8500D

Multi Channel Programmable Filter-Equalizer. Use Manual. Digital. Terrestrial. Ref. : 6505

Multi Channel Programmable Filter-Amplifier. User Manual I-II III V-U SAT. Stop Channel SAT Slope Start Channel SAT ON / OFF.

User Manual. UNIVERSE Ref. 8600

Satellite B or D. Satellite Inputs (LNB Trunk)

V/L V/H H/L H/H. Satellite - Input. Programmable Cascadable switch. with 32 User Bands with Terrestrial input & 1 Legacy port

User Manual. UNIVERSE Ref. 8600

Unicable II Cascadable switch with Terrestrial input and 4x Sky dscr/satcr/legacy+terrestrial outputs

Installation location

User Manual. UNIVERSE Ref SW Release

HDMI 1-in 1-out Extender via CAT-5e/ CAT-6

Operating Instructions

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

User Manual PROHDMI STREAMER/MODULATOR. Ref /

User guide. Stand alone Multiswitches SMC Cascadable Multiswitches SMU Amplifiers. Multiswitches

HDTV Supply Inc. reserves the right to make changes in the hardware, packaging and any accompanying documentation without prior written

Operating Instructions

Grandbeing. HDMI Splitter. Operating Instructions(P/N of this Instructions is INSSP0108)

Single cable multiswich programmer PC102W

Grandbeing. HDMI Matrix. Operating Instructions(P/N of this Instructions is INSMX0404-HH1) FEATURES

HDBaseT Extender Over Single Cat5e/6 cable

Operating Instructions

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

LINK EXT40-4KUHD 4:4:4 HDR HDBaseT Extender. User Manual. Version: V1.0.1

Grandbeing. HDMI Extender (By CAT-5E/6 cable) Operating Instructions(P/N of this Instructions is INSEX0101-U30/U31) FEATURES

Grandbeing. HDMI Splitter. Operating Instructions(P/N of this Instructions is INSSP )

Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16)

Grandbeing. HDMI Splitter(Asynchronous Switching Method) Operating Instructions(P/N of this Instructions is INSGB07SW0102)

HDMI Converter. Operating Instructions(P/N of this Instructions is INSYH0101)

Unicable II Programmer. IDLU-PROG01-OOOOO-OPP Item: Installation & User Guide

User s manual OLY 9X K OLY 9X OLY 9V. User s Guide. Headend cascade multiswitch OLY 9X K Cascade multiswitch OLY 9X. Cascade line amplifier OLY 9V

Grandbeing. HDMI Matrix (Router Type) Features

Vision EV5-D2, EV5-D4 multi-switch installation

presents : Single Transmod Ref. 8600

Grandbeing. HDMI Converter. Operating Instructions(P/N of this Instructions is INSSH S) FEATURES

USER MANUAL DUX-TX DUX-RX HDMI EXTENDER

Operating Instructions

User Manual CS-HDBTLPOER m HDBaseT Extender with Bi-directional PoE. Version: V1.0.0

SAT IF distribution system

ZVOX AccuVoice TV Speaker MODEL AV150.

Unicable II Programmable/cascadable multiswitch with 32 User Bands, 4 Universal/Wideband Satellite inputs & 1 Terrestrial input


4KEX70-L. HDBase-T Lite Extender. User Manual

Installation Manual VIP 1003

Model /29S RF Splitter

By CHANNEL VISION. Flush Mount Amplifier A0350

Register your product and get support at SDV5122/27. EN User manual

HDTV Supply. Mega Scaler. Operating Instructions FEATURES

User manual Transmodulators. Ref. 5103S/5103T/5103Q/5130

Grandbeing. HDMI Convertor. Operating Instructions(P/N of this Instructions is INSMS A) FEATURES


w w w.w h y t e t e c h n o l o g i e s.c o m.

MAX T200 HD QUICK INSTALLATION GUIDE

Utility Amplifier GA6A Model

MX-DIGITAL COAXIAL CONVERTER MX-1226

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

Bring High-Definition to your life!

HOME THEATER. HDMI HDBaseT Lite Extenders. Vanco Part Number: Technical Support

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

ZVOX AccuVoice TV Speaker Model AV203

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

ZVOX AccuVoice TV Speaker Model AV203

V TV / SATELLITE DC Power Tester

DISH Pro Hybrid 42 Switch Installation Guide

IMPORTANT SAFETY INSTRUCTIONS


PRODUCT MANUAL : 1x8 Splitter/Extender : Receiver (Sold Separately)

User Manual HD-HAUD-SP-RX. 100m HDBaseT HDMI Receiver

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

DisplayPort Extender over 2 LC Fibers

User Manual. Model 979T and 979R Digital Audio Converters

a Quick Guide Triax Multi Switches

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

User Manual TL-TP70-HDIR 70m Extender with ARC and IR All Rights Reserved Version: TL-TP70-HDIR_180723

HDMI Extender Transmission more than 3800M

User Manual TP70L. HDBaseT Extender. All Rights Reserved. Version: TP70L2016V1.1

NS-3 RF Noise Source Operation Manual

SD/HD/3G-SDI Video + Power + Data RS-485 Transmission over Coax Kit

Bring High-Definition to your life!

HOME THEATER. HDMI Selector Switches. Vanco Part Numbers (5x1) (3x1) Technical Support

DisplayPort Extender over 2 LC Fibers

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

ASH - EOC-01. Ethernet Over Coax Adapter User Guide

SAT IF distribution technologies. Multiswitches and single cable multiswitches for 1, 2, 3 or 4 SAT positions

Multi channel programmable Filter-Amplifier

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

2.0 Wall Mount TV Soundbar Instruction Manual


INSTALLATION MANUAL VIP 1903 / VIP 1903 T VIP 1963 / VIP 1963 T

HDMI Extender EX12 MODEL:SX-EX12. Dear Customer FEATURES NOTICE. Operating Instructions

HD-CM HORIZON DIGITAL CABLE METER

Transcription:

User Manual SCR Multiswitch Ref. 9744SKY, 9746SKY, 9748SKY

No part of this manual may be copied, reproduced, transmitted, transcribed or translated into any language without permission. Unitron reserves the right to change the specifications of the hardware and software described in these manuals at any time. Unitron cannot be held liable for any damages resulting from the use of this product. Specifications are subject to change without notice. 2/16 Unitron - Frankrijklaan 27 - B-8970 Poperinge - Belgium T +32 57 33 33 63 F +32 57 33 45 24 email sales@johansson.be www.johansson.be - www.unitrongroup.com 2

CONTENTS 1. INTRODUCTION... 4 Product description... 4 Package contents... 4 Mounting... 5 Typical application... 6 2. INSTALLATION OF THE HARDWARE... 7 3. CONFIGURATION OF THE MODULE... 8 STB Power to Trunk Switch... 8 Terrestrial amplifier... 8 Diagnostic LED s:... 8 dscr Modes:... 9 4. TECHNICAL SPECIFICATIONS... 10 5. SAFETY INSTRUCTIONS... 12 6. CONDITIONS OF WARRANTY... 13 3

1. INTRODUCTION Product description The 974xSKY products are designed to support a wide range of new and existing multiswitch installations. Each 974xSKY unit has: 4 cascade-able LNB inputs from universal Quattro LNBF : VL HL VH HH 1 terrestrial trunk. 4, 8 or 16 SCR/Legacy outputs (9744SKY, 9746SKY or 9748SKY) 1 DC input. Each output can support a wide variety of satellite receivers : In legacy mode, the 974xSKY outputs can be used as a standard multiswitch. In SCR mode, each 974xSKY output supports up to 16UBs with all versions of the single cable technology. This includes OLT, SCR, CSS, EN50494, EN50607, and newer versions. As all outputs are independent, the installation can be a mix of legacy and SCR connections. The terrestrial part allows to support any service that operates below 1 GHz, which includes terrestrial reception, cable and DOCSIS reception. The trunks enable to cascade multiple products to support big installations of more than 100 households in MDU applications, like apartments, or more than 100 rooms in hospitality environments, like hotels. The DC power can be inserted at any product. In cascaded systems, multiple power supplies might be needed, see Diagnostic LED s for more information. The Johansson reference for the powersupply is 2460 or 2460UK. Package contents 1x Digital SCR Multiswitch (9744SKY, 9746SKY or 9748SKY) 4

Mounting A B 9744SKY 98 mm 179 mm 9746SKY 179 mm 179 mm 9748SKY 377 mm 179 mm 5

Typical application for the UK 6

2. INSTALLATION OF THE HARDWARE The optional power supply (ref 2460/2460UK) can feed multiple multiswitches. Ref. Amount of products per power supply 9744SKY 4 9746SKY 2 9748SKY 1 The four trunks are DC isolated from each other, so 13 V and 18 V can be supplied separately from trunk out to trunk in. All 4 LNB trunks should always be cascaded or terminated with a DCblocked 75-Ohm terminator. All unused SCR/Legacy outputs should be terminated with a 75-Ohm terminator for proper terrestrial signals. In this example 1 multiswitch is installed per floor. Only 2 power supplies are used to power the 4 multiswitches. 7

3. CONFIGURATION OF THE MODULE STB Power to Trunk Switch OFF This is the default state, as trunks will feed all cascaded units and the LNB. Power comes from DC inserted at the DC Input of 1 or more cascaded units. ON The STB will feed the unit and the LNB. This is only allowed when 1 unit is used in the system. From the moment 2 are cascaded, the position OFF should be selected. Otherwise, 1 STB will need to feed all units. There is always DC pass-through on the trunks (Sat only). Terrestrial amplifier The Terrestrial trunk has an integrated amplifier that can be turned into bypass- or amplifiedmode. Only in bypass mode, DOCSIS signals can pass through. The Terrestrial trunk should always be terminated with a 75-Ohm terminator. Diagnostic LED s: Special high power startup mode: status LED s blink alternating GREEN and RED. This is a special mode active when starting up the device (when the trunks are powered, not when STBs power the unit). In this mode, the unit will consume the maximum power. This allows the installer to check that there will be adequate power for the system under full (SCR) load. This High power startup mode gives the installer a 15-second window to check the performance of the power supplies. After 15 seconds, the unit will go into 1 of the 2 operational modes (SCR or Legacy). During the 15 seconds, the power-up diagnostic LED of all 974xSKY units should be checked. If the voltage level on the trunks is too low for the unit to operate, then the Power up Diagnostic LED will be orange, connect an extra DC supply to the DC input. If the voltage level on the trunks is OK, then the LED will be green. 8

dscr Modes: SCR mode: Legacy mode: Slow blinking GREEN Solid GREEN The 974xSKY can work in two modes on each output independently SCR Mode and Legacy Mode. The default mode is Legacy Mode. The module will automatic switch from Legacy to SCR mode upon the first DiSEqC command when a SCR set top box is connected. If SCR mode has been activated, that specific output needs to be powered-off to go back to Legacy Mode. SCR mode: status LED slow blinking green When a compatible Set Top Box is connected and set in SCR Mode up to 16 User Bands can be generated and can be tuned independent of each other to any LNB input and transponder. The 974xSKY is compatible with the Sky, EN50607 and EN50494 CENELEC-standard. The set top box sends the desired data for the LNB input and frequency selected in DiSEqC commands. Legacy mode: status LED solid green When a Legacy Set Top Box (non-scr Compatible) is connected to any of the ports, the dscr works like a standard multiswitch allowing only one tuner to be connected to each output and allowing the tuner to select a single band, polarity and frequency from the relevant transponder using 13/18 V and 0/22 khz tone switching. 9

4. TECHNICAL SPECIFICATIONS Operating Frequency Range 9744SKY 9746SKY 9748SKY Satellite 950 2150 MHz Inputs 4 Outputs * (Trunk) 4 Max and Min Input Txp Power Level Trunk lines in to out gain In to SCR out gain In to legacy out gain -35 to -5 dbm -2.5 (-1.5 Typical) -4 Max (-2.5 Typical) -9 Max (-6 Typical) -15 to +15 Typical, AGC controlled -13 Max (-8 typical) Return loss >8 Operating Frequency Range Terrestrial 88 790 MHz Inputs 1 Outputs * (Trunk) 1 Max Input Mux Power Level Trunk Lines in to out gain Bypass: -7 Max (-5 Typical) Amplified: +4 Min (+6 Typical) Amplified: 96 dbµv Min Bypass: -10 Max (-8 Typical) Amplified: +1 Min (+3 Typical) Amplified: 88 dbµv Min Bypass: -20 Max (-16 Typical) Amplified: +2 Min (+6 Typical) In to SCR out gain Bypass: -23 Max (-17 Typical) Amplified: -12 Max (-6 Typical) Bypass: -27 Max (-21 Typical) Amplified: -16 Max (-10 Typical) Bypass: -34 Max (-24 Typical) Amplified: -16 Max (-10 Typical) dscr Output Ports dscr Output Ports 4 8 16 Supported Output Modes SCR Mode Indication SCR Output Power per Txp SCR channel bandwidth SCR + Legacy + DTT/DAB/FM Multicolor/Flashing LED -23 dbm Min (-21 dbm Typical), AGC controlled 46 MHz SCR User Bands 16 SCR Standard (auto detect & switch) Legacy Output Power per Txp DiSEqC signaling BSkyB SCR, CENELEC EN50494, CENELEC EN50607, Universal LNB tone & volts Up to -15 dbm, no AGC DiSEqC compliant 10

*: Unused ports needs to be terminated by 75 Ohm DC-blocked terminator DC Power DC Power Connector Power Indication Unit can be powered via PWR port, trunk lines or outputs (all F-types) Green LED (front of unit) Power Supply Voltage 10 to 20 VDC 10 to 20 VDC (from STB) 11 to 20 VDC (from DC Input) Max Power Consumption DC from trunk lines out to in Supply current to LNB (switchable) Short circuit protection & power on diagnostics SCR mode: 6W per pair of ports LNB emulation mode: < 2,1 W per port (Ter Amp OFF) Yes (not for terrestrial trunk) 500 ma @ 20 V Yes Ground tags 1 Operating Temperature Range -20 to +50 C, Indoor housing Sky UK EN50607 EN50494 UB FREQ UB FREQ UB FREQ 3 1680 5 985 1 1210 9 1280 6 1050 2 1420 11 1380 7 1115 3 1680 14 1480 8 1275 4 2040 15 980 9 1340 16 1030 10 1485 17 1080 11 1550 18 1130 12 1615 19 1530 13 1745 20 1580 14 1810 21 1630 15 1875 22 1730 16 1940 23 1780 24 1830 25 1880 26 1930 11

5. SAFETY INSTRUCTIONS Read these instructions carefully before connecting the unit To prevent fire, short circuit or shock hazard: Do not expose the unit to rain or moisture. Install the unit in a dry location without infiltration or condensation of water. Do not expose it to dripping or splashing. Do not place objects filled with liquids, such as vases, on the apparatus. If any liquid should accidentally fall into the cabinet, disconnect the power plug. To avoid any risk of overheating: Install the unit in a well aery location and keep a minimum distance of 15 cm around the apparatus for sufficient ventilation Do not place any items such as newspapers, table-cloths, curtains, on the unit that might cover the ventilation holes. Do not place any naked flame sources, such as lighted candles, on the apparatus Do not install the product in a dusty place Use the apparatus only in moderate climates (not in tropical climates) Respect the minimum and maximum temperature specifications To avoid any risk of electrical shocks: Connect apparatus only to socket with protective earth connection. The mains plug shall remain readily operable Pull out power plug to make the different connections of cables To avoid electrical shock, do not open the housing of adapter. Maintenance Only use a dry soft cloth to clean the cabinet. Do not use solvent For repairing and servicing refer to qualified personnel. Dispose according your local authority s recycling processes 12

6. CONDITIONS OF WARRANTY Unitron N.V. warrants the product as being free from defects in material and workmanship for a period of 24 months starting from the date of production indicated on it. See note below. If during this period of warranty the product proves defective, under normal use, due to defective materials or workmanship, Unitron N.V, at its sole option, will repair or replace the product. Return the product to your local dealer for reparation THE WARRANTY IS APPLIED ONLY FOR DEFECTS IN MATERIAL AND WORKMANSHIP AND DOES NOT COVER DAMAGE RESULTING FROM: Misuse or use of the product out of its specifications. Installation or use in a manner inconsistent with the technical or safety standards in force in the country where the product is used Use of non-suitable accessories (power supply, adapters...). Installation in a defect system. External cause beyond the control of Unitron N.V. such as drop, accidents, lightning, water, fire, improper ventilation THE WARRANTY IS NOT APPLIED IF Production date or serial number on the product is illegible, altered, deleted or removed. The product has been opened or repaired by a non-authorized person. NOTE Date of production is YYWW format, example 1447 = year 2014 week 47. For the serial number barcodes, the date corresponds to the 4 first numbers 13

14

15

UNITRON NV Frankrijklaan 27 B-8970 Poperinge Belgium T +32 57 33 33 63 F +32 57 33 45 24 sales@johansson.be www.johansson.be 16