Technical Specification Pavilion Dance

Similar documents
DEREHAM MEMORIAL HALL

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Technical Specification

Technical Specification

Technical Specification

TECHNICAL SPECIFICATIONS

Theatre Technical Specifications

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Stage. Get In & Parking

Main House Technical Specifications

Technical Specification for the Alley Theatre, Strabane

2017 TECHNICAL SPECIFICATIONS

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Summary. Access and Parking

Technical Pack. Attenborough Arts Centre

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

UNIVERSITY CONCERT HALL. Technical Specification

ISLAND HALL TECHNICAL INFORMATION

CENTRE FOR PERFORMING ARTS

CHELSEA THEATRE. Technical Specifications

Technical Specifications Updated 01/10/2017. Stage

New Theatre Royal Lincoln Technical Information

Main House Technical Specification

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

Dugdale Centre Technical Specification

Technical Specification. Updated: April 2016

Arlington Arts Tech Spec 2018

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Matt Dann Cultural Centre

Technical Specification Ardhowen Theatre

Dr JOHN GALLAGHER CONCERT CHAMBER

Stage. Please see Tron, Main House Lighting Rig Info.pdf for more information. Get In & Parking

Cornerstone Technical Specifications 2018 / V1

The Lights Technical Guide June 2017

Pleasance London Main House Visiting Company Information Pack May 2017

Rhodes Arts Complex Bishops Stortford. Technical Specifications

TECHNICAL SPECIFICATIONS

Technical Specifications

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

INFORMATION FOR VISITING COMPANIES

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Technical Specifications

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Technical Services and Specification

Technical Information

Latrobe Performing Arts Centre

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

THE STREET THEATRE. Technical Specifications

Hopgood Theatre NOARLUNGA CENTRE

Technical Specifications. Taylor Little Theater

RPAC REDLANDS PERFORMING ARTS CENTRE

GORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16

MAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014

Technical Specifications Nov 2016

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

The Haymarket Basingstoke Technical Specifications

Technical Manager Dave Nott Tel: * Mo: Deputy Technical Manager Anton Holmes Tel: *

MAIN THEATRE TECHNICAL SPECIFICATION

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

Visy Theatre technical information and general specifications 2019

Source 4 Junior Zoom Profile 575W 14 part of universal rig

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

Theatre Technical Specification

REHEARSAL ROOM 2 CURVE TECHNICAL SPECIFICATIONS & EQUIPMENT LISTS Updated October 2011 Contact details

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Avant Garde Dance & The Place Fagin s Twist Tech Spec 2016

TECHNICAL SPECIFICATION

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

John Leslie Theatre. Technical Specifications. Updated July 2018

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE

Technical Director of Production Andrew Quick Ext 252

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Information for Incoming Companies

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Enormous Room Technical Rider & General Lighting Plan

TECHNICAL SPECIFICATIONS RIVERSIDE THEATRE

Lighthouse Theatre Technical Specification

Faris Family Studio at the Dance Centre, Vancouver BC 677 Davie Street, Vancouver, British Columbia. V6B 2G6

Technical Data Sheet

Darlington Hippodrome Technical Specification

"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

Technical Specification (Studio Theatre)

Derby Theatre. Technical Information Main Stage. Derby Theatre. 15 Theatre Walk. St. Peters Quarter. Derby DE1 2NF.

Technical Specification (Studio Theatre)

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

TECHNICAL SPECIFICATIONS

Harlequin Vinyl floor (permanently installed) Clean removable Harlequin vinyl floor available for hire Rake

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

HIRE AND TECHNICAL INFORMATION

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

Technical Information

Studio 180. Electronic and Print versions of the venue ground plan are available from the Technical Director.

Esso BHP Billiton Wellington Entertainment Centre

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

Transcription:

Technical Specification Pavilion Dance Contact Information Position Name Email Phone Number Technical Manager Technician Neil Kingston Louise Buckton neil@pdsw.org.uk louiseb@pdsw.org.uk 01202 203630 01202 203633 FOH and Facility Development Manager Andrew Christie andrew@pdsw.org.uk 01202 203630 01202 203632 Venue Manager Louise Billingsley louise@pdsw.org.uk 01202 203630 01202 203632 Please see the companies info pack for travel information. Ocean Theatre Seating Capacity: Normally 178 but can be extended to conference style 220 (please note that this affects the stage size). Can be in the Round, Traverse, Cabaret style (capacity negotiation with the Box Office). There is a wheelchair access platform on stage left of the theatre (normally used as control position). Front row seats can be taken out for wheelchairs. Ocean Theatre stage dimensions As a Studio Space with the seating unit retracted - 11.2m Wide 17.7m Deep Normal Theatre configuration (178 seats) - 11.2m Wide (8.2m between the black serge legs) 10.5m Deep) (Please note fire doors either side of the front of the audience so no LX or set please see photos) End on conference (220 seats) - 11.2m Wide (8.2m if using Wings) 8m Deep (approx). This configuration is achieved by adding 3 extra seating rows at floor level. The screen position is 5 m in depth from the back wall Grid height 5m when fully flown Flooring: Sprung Maple Floor, no fixing, drilling allowed in this space (alternatively other methods can be used such as stage weights or tying off) Dance Floor: Reversible Black/Grey Harlequin dance floor available (10m x 10m). Please make us aware any materials used in the performance which could damage the flooring.

Get in Routes: One: Through back fire exit (0.96m width / 2m height) and double doors (1.55m width / 2m height) to Ocean Room doors ( 1.69 m width / 2m height). Two: Through Green room fire exit ( 1.40m width / 2.2m height) then into corridor ( 0.61m width / 2.2 m height) to double doors and Ocean Room doors ( measurements same as above) Three : Through Seafront studio fire exit ( 1.35 m width / 2.35 m height) through studio and through double doors and Ocean Room doors ( measurements same as above ) Masking 4 sets of legs Approx 5m in height. Painted white back wall, with the option of black tabs (serge) to be used. This is on a tab track (operated from SR) full not flat. Access Equipment Motorized GR-15 (IPAF license required to operate). One large set of Zargees. One small set of steps. Stage Machinery/Rigging 5 motorised IWB bars (fixed position) 10m in length. Bars 1-4 have 12 dimmable circuits, 4 non-dim circuits (hard power), 2 female 5 pin DMX sockets. Bar 5 has 8 dimmable circuits and 7 non-dim circuits (hard power), and 2 female 5 pin DMX sockets. Bars full out dead 5m. 2 FOH IWBs (SL and SR) with 6 dimmable circuits, 2 non-dim circuits (hard power) and 1 female 5 pin DMX socket. 2 fixed booms per side (SL and SR) 1.41m from floor, 6 dimmable circuits, 2 non-dim circuits (hard power), 1 female 5 pin DMX socket (6 homemade floor stands available for lanterns) 6 free standing booms bases.(positions negotiable) please note some positions may not be possible due to fire exits.

Distance between bars Tabs Open or Closed Bar 5 0.74m from back wall Bar 4 2.61m Bar 3 4.27m Bar 2 1.90m Bar 1 2.32m Power Facilities USR power distro on back wall. 3 x 32 A single phase 1 x 32 A 3 phase 1 x 63 A 3 phase 1 x 125 A 3 phase There are multiple 13 A sockets on stage. All dimmable and hard power outlets are 15 A Various facility panels around the theatre for DMX, video patch, tie lines, mic lines, speakons etc ETC non-dim control panel 47 x 3K Please Note There are fire and exit signs at the doors on the front of the stage that cannot be turned off. There is also a fire exit sign USL that cannot be turned off. On stage doors can be open for extra wing space (corridor). There is a blues facility in corridor for the performance. Please be aware that USL and USR doors are fire exits so a clear path must be kept in the corridor.

Lighting Equipment Control Desk Dimmers ETC Congo Jr Cat 6 to DMX converter Across ETC dimmer rack, 116 x 3K Please note only 100amps per phase see LX plan for phasing per bar Please find house rig plan attached is required. Quantity Equipment Gobo Sizes 24 ETC Source 4 Zoom 15/30 10 gobo holders size B, No Iris 24 Selecon Rama 1.2K Fresnel (complete with barn doors) 24 Thomas Par 64 medium (CP62) parcans floods 4 4 cell Selador Vivid R LED Cyc wash (complete with horizontal & vertical frost panels) 2 1 cell Selador Vivid R LED Cyc wash (complete with horizontal & vertical frost panels) N.B Please note the frost in the Seladors does not cover the entire back wall. 14 JBL LED colour wash More unit on request 5 Robe colour spot 575 AT M1 More unit on request 1 Unique Hazer 2.1 Sound Mixing Desk Yamaha DM1000 Yamaha MG166c N.B. If the sound is opped in the theatre, a Yamaha MG166c is used because it is built into a portable effects rack. Quantity Equipment 2 Yamaha MG166c 2 D&B E12 SL and SR speakers 2 D&B E12D SL and SR Monitor speakers 2 D&B E12 spare (outdoor system) Can be added to the system if required 2 D&B E15X sub-bass 2 Tascam CD-RW900 player/recorder 4 Sennheiser E845 microphones 4 Sennheiser 345S microphones 2 Sennheiser EW345 hand held radio microphones 2 Sennheiser EW322 clip-on radio microphones 4 Tecpro belt packs & headsets 4 DI Boxes N.B. There is show relay/paging in both dressing rooms (there is a local volume control), backstage corridor/1 studio (garden studio). Video relay to both dressing rooms

AV Projector position is in control room on a movable table. It cannot be rigged in the auditorium. Source can project on to screen or back wall. Quantity Equipment 1 Christie lx 700 projector, 1.3 1.8:1 Lens. 1 meter/ 50 cm rigging poles. 1 Kramer scaler HQV VP/725XL Silicon Optix 1 Blu-ray player JM Lectern 1 Sennheiser ME334 lectern microphone 1 EW 312 G3 lapel radio microphone 1 Blu-ray player PC Plug in Crestron LCD panel controls lights/dvd/microphones etc (Can be controlled on Lectern, or by show operator at control point) Cinema 1 Dolby DS200 Digital Cinema Server 1 Dolby CP750 Digital Sound Processor Miscellaneous 2 dressing rooms available with wet rooms (disabled access shower) and all facilities such as sink, chairs, mirrors (with lights), hanging rails and lockers ( 1 coin operated, money returned). Dressing room keys can be signed out at reception, charge for non-return. Toilet facilities next to dressing rooms. Kitchen with the facilities of a fridge, kettle, microwave, dishwasher, iron & ironing board. Washing machine & tumble dryer (for costumes not personal washing) available to cast and crew. Towels available to be signed out at reception, charge for non-return. Water cooler in backstage corridor. 2 black sofas backstage.

Ocean Theatre with masking, seating & dance floor.

Ocean Theatre as a studio set up