MC111 USER / INSTALLER MANUAL. v3.0 REV. 04/2018

Similar documents
MC50BR USER / INSTALLER MANUAL. v5.0 REV. 07/ V

MC2 USER / INSTALLER MANUAL. v5.1 REV. 03/2018

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 2 / SEAV LRS 2150 SET

Installer manual. RS17.P Control panel for swing gates at 24 V DC with encoder EKKO 204D

E R A I GATE OPENERS DEPARTMENT

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

CONTROL UNIT BIOS1 HR Programmable Control board for sliding gates

POLARIS 4 ELECTRONIC CONTROL BOARD FOR SLIDING GATES MANUAL

Tech Support: Customer Service: General Tech Questions: Tech Docs:

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

PG SERIES Garage Door Openers USER MANUAL

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

ORDER CODE: EQLED65 USER MANUAL

Noise Detector ND-1 Operating Manual

Troubleshooting CS800/LC900 Bikes

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

LIGHT COPILOT II. elationlighting.com Internet:

L /2013 rev.4 CP.BISON OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Operating Manual. Basic Control BC16. two-channel for eco moon

Fusion 120 Zoom. User Manual. Order code: EQLED068

TAC1 Telephone Entry System

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

Instruction Manual. 7" Wireless Camera System with Wired Side Camera Inputs RVS-355W. Reverse With Confidence 1

OSD. EXECUTIVE / MiniDome USERS MANUAL. USING THE MOTOSAT DISH POINTING SYSTEM EXECUTIVE / MiniDome OSD

Owner s Manual LED COMMANDER 16/2

Junior Max (JR Max ) Controller

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

4 Wiring Brochure Wiring and installation of specific control

ROGER CONTROLLER. controller for 2 motors 230Vac H70/104AC - H70/105AC. EN - Instruction and warnings for the installer. automazioni evolute

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

FOREST SHUTTLE S / L / M RECEIVER

MATE3 Owner s Manual Addendum

FD Trinitron Colour Television

7 Day Digital Light Switch with Optional Dusk Start

Two (2) fibers Detachable DisplayPort 1.2 Extender. User s Manual for the DPFX-200-TR. Manual Contents

VNS2200 Amplifier & Controller Installation Guide

TeamWork Kits Installation Guide

V/L V/H H/L H/H. Satellite - Input. Programmable Cascadable switch. with 32 User Bands with Terrestrial input & 1 Legacy port

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Two (2) fibers Detachable DisplayPort Extender

Stratos Duo RGB. User Manual. Order code: EQLED371

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

PL2410W LCD Monitor USER'S GUIDE.

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

KHT 1000C HV-Probe Calibrator. Instruction Manual

Instruction Manual Model BlockUpconverter

DLP200M 2 Relay Module for Heating and Cooling Plants

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

USER MANUAL Full HD Widescreen LED Monitor L215ADS

Aspect 2 Circuit Digital Scene Control

USER MANUAL Full HD Widescreen LED Monitor L215IPS

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DDW36C Advanced Wireless Gateway - Safety and Installation Product Insert. Federal Communications Commission (FCC) Interference Statement

LINK POWER IR RX IR TX 12V 2A. HDMI Out EL-4KHDBT-RX-40-IR. HDBT In LINK EL-4KHDBT-RX-40-IR. User Manual

Automation for: SWING GATES

MANUAL ENGLISH Core Club Ordercode: D2314

.Power Distribution Center. PD-1. Instruction Manual

IPSTB1200 /IPC3200 Media Client User guide

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

DLP600M 6+1 Relay Module for Heating and Cooling Plants

User Guide. Centrex Recording Interface

Instruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1

SWIFT624-CB AUTOMATION SYSTEMS. DRIVER FOR SWIFT624 DRIVE Assembly manual for the installers. automation systems. ver. 1.0

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

3.5 TFT LCD CCTV Service Viewer with Wristband

Smart Control SC16 3-Channel for matrix

Electronic converter for level transmitters MT03L Instructions manual

OPERATION AND MAINTENANCE

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

Controller DMX DC-1224

Two (2) fibers Detachable HDMI 2.0 Extender. User s Manual for the HDFX-300-TR. Manual Contents

KRF EMC Filters Installation, Operation and Maintenance Manual

AT450SAW Programmable Selective Amplifier

Model Number Structure

Master Time Clock MTC Users Manual

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

SceneStyle2 User Guide

Always there to help you. Register your product and get support at SRP3013. Question? Contact Philips.

VIVO-D203(M) Quick installation and programming guide. Elements of the complete installation

Instruction Manual Model # Block Upconverter

2.4GHz Digital Wireless Video Door Phone User Manual

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

2. only. INTRODUCTION...3. Do SPECIFICATION...3 SYSTEM SETTINGS...7. Installation. Troubleshooting. OVERVIEW Important Information

PLL1920M LED LCD Monitor

PLL2210MW LED Monitor

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE

Installation Guide. Cellular Plug-in for Inverters with SetApp. Version 1.1

Transcription:

MC111 USER / INSTALLER MANUAL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 v3.0 REV. 04/2018

00. CTT INDEX 01. SAFETY INSTRUCTIS STANDARDS TO FOLLOW 01. SAFETY INSTRUCTIS STANDARDS TO FOLLOW 02. CNECTI SCHEME CNECTI OF COMPTS TO THE CTROL BOARD - INDUSTRIAL ROLL-UP DOOR CNECTI OF COMPTS TO THE CTROL BOARD - SLIDE 4000 03. THE CTROL BOARD GERAL DEFINITIS TECHNICAL SPECIFICATIS WORK FREQUCY CNECTOR S DESCRIPTI PROGRAMMING PRE-RECOMDATIS MC111Y MODULE KEYS FUNCTI DIPPERS FUNCTIING DISPLAY INDICATIS 04. INSTALLATI ESSTIAL STEPS FOR INSTALLATI FUNCTIS FUNCTI 01 SELECT DOOR TYPE FUNCTI 02 FUNCTI NOT USED FUNCTI 03 CHANGE PAUSE TIME FUNCTI 04 ADJUST STRGTH FUNCTI 05 OPING FREQUCY FUNCTI 06 CLOSURE FREQUCY FUNCTI 07 DECELERATI FREQUCY DURING THE OPING FUNCTI 08 DECELERATI FREQUCY DURING THE CLOSURE FUNCTI 09 AMPEROMETRIC SSITIVITY (OPING) FUNCTI 10 AMPEROMETRIC SSITIVITY (CLOSURE) FUNCTI 11 DECELERATI AMPEROMETRIC SSITIVITY (OPING) FUNCTI 12 DECELERATI AMPEROMETRIC SSITIVITY (CLOSURE) FUNCTI 13 ACCELERATI RAMP FUNCTI 14 FUNCTI NOT USED FUNCTI 15 ABLE TESTING FUNCTIS FUNCTI 16 MANEUVERS COUNTING FUNCTI 17 PREST MAN 06. TROUBLESHOOTING INSTRUCTIS FOR CSUMERS / TECHNICIANS 1B 2 3 4 5A 5A 5B 6A 6B 6B 7A 7A 7B 8 9A 9A 9A 9B 9B 10A 10A 10B 10B 11A 11A 11B 11B 12A 12A 12A 12B 13 1A ATTTI: It is important for your safety that these instructions are followed. Keep these instructions in a safe place for future reference. The ELECTROCELOS S.A. is not responsible for the improper use of the product, or other use than that for which it was designed. The ELECTROCELOS S.A. is not responsible if safety standards were not taken into account when installing the equipment, or for any deformation that may occur. The ELECTROCELOS S.A. is not responsible for insecurity and malfunction of the product when used with components that were not sold by the them. This product was designed and manufactured strictly for the use indicated in this manual. This control board is not appropriate for inflammable or explosive environments. Any other use not expressly indicated may damage the product and/or can cause physical and property damages, and will void the warranty. Do not make any changes to the automation components and/or their accessories. Control board for indoor use with connection. Keep remote controls away from children, to prevent the automated system from being activated involuntarily. The customer shall not, under any circumstances, attempt to repair or tune the automatism. Must call qualified technician only. The installer must have certified professional knowledge at the level of mechanical assemblies in doors and gates and control board programmation. He should also be able to perform electrical connections in compliance with all applicable regulations. The installer should inform the customer how to handle the product in an emergency and provide him the manual. 1B This product is certified in accordance with European Community (EC) safety standards. This product complies with Directive 2011/65/EU of the European Parliament and of the Council, of 8 June 2011, on the restriction of the use of certain hazardous substances in electrical and electronic equipment. (Applicable in countries with recycling systems). This marking on the product or literature indicates that the product and electronic accessories (eg. Charger, USB cable, electronic material, controls, etc.) should not be disposed of as other household waste at the end of its useful life. To avoid possible harm to the environment or human health resulting from the uncontrolled disposal of waste, separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources. Home users should contact the dealer where they purchased this product or the National Environment Agency for details on where and how they can take these items for environmentally safe recycling. Business users should contact their vendor and check the terms and conditions of the purchase agreement. This product and its electronic accessories should not be mixed with other commercial waste. This marking indicates that the product and electronic accessories (eg. charger, USB cable, electronic material, controls, etc.) are susceptible to electric shock by direct or indirect contact with electricity. Be cautious when handling the product and observe all safety procedures in this manual.

02. CNECTI SCHEME CNECTI OF COMPTS TO THE CTROL BOARD RAPID DOOR LED11 LED10 LED9 LED8 LED7 LED6 LED5 LED4 LED3 LED2 RTX SW2 SW1 SET TX CN1 LD0 LED1 10A 1 2 3 F N 4 5 6 7 8 9 If you dont used input nº16 make a MOTOR shunt with nº20. 10 11 21 23 25 12 13 14 15 16 17 18 19 20 22 24 26 27 28 29 12Vac 12Vdc Relé N.O B.S B.S.O PUL PEDCOM D.S COM B.L O.P C.L FCH FAP 24V AC Connection of the 8K2 safety bands to the RTX 2252 (Sensor) SW1 Limit-switch OP CLOSE LED11 LED10 LED9 LED8 LED7 LED6 LED5 LED4 LED3 LED2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Spiral 10A F N MOTOR 12Vac - + 12Vdc - + Relé N.O B.S B.S.O PUL PEDCOM D.S COM B.L O.P C.L FCH FAP 24V AC Triangle connection RTX 2251 (Base) BUZZER Electric brake SW1 MITOR Motor MU PROG. CODE 3 CH2 CODE 2 CH2 CODE 1 CH2 CODE 3 CH1 CODE 2 CH1 CODE 1 CH1 TEST N F Transf. 12V F N MR5 Receiver 12V 24V 0V CH1 CH2 A1 A2 Relay COM NO NOTA relay is not included in the kit. M1601 radar 12/24V AC/DC COM N F Photocell Flashlight COM NC Auxiliary input 24V MD100 Module 3 4 10 11 1 2 STOP Push button NO J1 J2 8K2 C 8K2 C SEL SET M1601 radar 12/24V AC/DC UP DOWN CN1 1 2 1 CN3 2 3 4 5 6 7 8 9 10 11 COM NO Control box 24 0 12 CH1 CH2 Test 24 0 2

02. CNECTI SCHEME CNECTI OF COMPTS TO THE CTROL BOARD SLIDE 4000 LED11 LED10 LED9 LED8 LED7 LED6 LED5 LED4 LED3 LED2 RTX SW2 SW1 SET TX CN1 LD0 LED1 10A 1 2 3 4 5 6 7 8 9 If you dont used input nº16 make a MOTOR Fshunt N with nº20. 10 11 21 23 25 12 13 14 15 16 17 18 19 20 22 24 26 27 28 29 12Vac 12Vdc Relé N.O B.S B.S.O PUL PEDCOM D.S COM B.L O.P C.L FCH FAP 24V AC Connection of the 8K2 safety bands to the RTX 2252 (Sensor) SW1 LED11 LED10 LED9 LED8 LED7 LED6 LED5 LED4 LED3 LED2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 10A F N MOTOR 12Vac - + 12Vdc - + Relé N.O B.S B.S.O PUL PEDCOM D.S COM B.L O.P C.L FCH FAP 24V AC OP F N A1 A2 Relay COM NO N F Flashlight Limit-switch CLOSE Motor RTX 2251 (Base) MITOR BUZZER SW1 J1 J2 MU PROG. CODE 3 CH2 CODE 2 CH2 CODE 1 CH2 CODE 3 CH1 CODE 2 CH1 CODE 1 CH1 TEST SEL SET MR5 Receiver 12V 24V 0V CH1 CH2 NOTA relay is not included in the kit. Flashlight Photocell COM NC MD100 Module Spiral 3 4 8K2 C 8K2 C 10 11 1 2 CN1 1 2 1 CN3 2 3 4 5 6 7 8 9 10 11 24 0 12 CH1 CH2 Test 24 0 Push-button 3

03. THE CTROL BOARD GERAL DEFINITIS LED Indicates the capacitor discharge LED DISPLAY Allows you to view the functions and other information in real time LED 1 Microcontroller activity Button Close (page 5B) Button Open (page 5B) Button Confirmation/ menu selection (page 5B) 1 2 3 4 LED 11 Closing limit-switch 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 LED 10 Opening limit-switch LED 2 Safety Band LED 3 Barrier / Safety Band LED 4 START LED 5 Pedestrian START LED 6 Photocells LED 7 STOP LED 8 Opening impulse LED 9 Closing impulse 4

03. THE CTROL BOARD TECHNICAL SPECIFICATIS 03. THE CTROL BOARD CNECTOR'S DESCRIPTI The MC111 is a control board for automation rapid doors and sliding gates equipped with our Slide 4000 motor. 1 2 3 4 Power supply Lightbulb s output Motor s output Auxiliary accessories output AC AC 50Hz 100W max. (intermittent) AC ou 3x AC (triangle) 12V-24V DC /AC 4 W máx. 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Security and transmitters in BT 24V DC Working temperature -20 C to + 55 C Control board dimensions 03. THE CTROL BOARD Min-Máx 225mm x 140mm Ind. Roll-u doors/ Ind. Stacking door WORK FREQUCY Eco Door SLIDE 4000 Opening speed 01/99Hz 50Hz 50Hz 50Hz Closing speed 01/99Hz 35Hz 35Hz 40Hz Opening deceleration speed 01/99Hz 25Hz 25Hz 25Hz Closing deceleration speed 01/99Hz 20Hz 25Hz 25Hz CN4 CN3 CN2 CN1 01 line input (phase) 02 line input (neutral) 03 line input (ground wire) 04 Motor s output 1 (phase) 05 Motor s output 2 (phase) 06 Motor s output 3 (phase) 07 AC Lightbulb 08 Lightbulb (common) 09 NOT USED 10 12V AC output 11 12V AC output 12 12V DC output- accessories 13 12V DC output- accessories 14 Auxiliary contact NO 15 Auxiliary contact NO 16 Safety band input - Closing (NC) 17 Safety band input - opening and closing (NC) 18 Input for START (NO) - (OPS/STOPS/CLOSES) 19 Pedestrian START input (SLIDE 4000) - NO 20 0V DC Common 21 Photocell input (NC) 22 Common 0V DC 23 STOP Input (NC) 24 Opening start input (NO) 25 Closing start input (NO) 26 Limit-switch input (opening) (NC) 27 Limit-switch input (closing) (NC) 28 24V AC Input 29 24V AC Input In the outputs 12 and 13 12V DC 28 and 29 24V AC 4 watts maximum 5A 5B

03. THE CTROL BOARD PROGRAMMING PRE-RECOMMDATIS 03. THE CTROL BOARD PROGRAMMING PRE-RECOMMDATIS Before proceeding to the control board configuration, note the following points listed in the table below in order to better understand the control board function: LEDs CN3 CN4 CN4 CN4 LED 1 LED lit when the control board is powered AC LED 2 LED off when the safety band (closing) is activated LED 3 LED off when the safety band (opening / closing) is activated LED 4 LED lit when it is given a START LED 5 LED lit when it is given a pedestrian START LED 6 LED off when the photocells are activated LED 7 LED off when the STOP button is activated LED 8 LED lit when the OP button is activated LED 9 LED lit when the CLOSE button is activated LED 10 LED off when the opening limit switch is activated LED 11 LED off when the closing limit switch is activated Courtesy light or flashing light: 07 and 08 This output allows connection of a flashing light (flashing output) 10 and 11 Running during opening pause and closing. Auxiliary output: 12 and 13 Auxiliary output to 12V DC accessories. 28 and 29 Auxiliary output to 24V DC accessories. 4W maximum Safety circuits: 16 and 17 This input allows connection of safety bands. The input 16 reverse the movement during closing (if you do not use the input, make a shunt). The input 17 stops and relieves during the opening and reverses during the closing (if you do not use the input, make a shunt). 21 This input allows connection of photocells. When closing, reverse (if you do not use the input, make a shunt). CN4 Control device (STOP, OP and CLOSE button): 23 This input allows the connection of a STOP button (NC). An order sent (switch to NO) during the movement of the gate / door, makes its immediate stop, stopped until you return to the normal state (switch to NC). After returning to NC state, the first maneuver will always be opening and with a delay of 5 seconds after sending order of radio control or push button. 24 This input allows connection of a opening button (only opening order). 25 This input allows connection of a closing button (only closing order). 03. THE CTROL BOARD Manages the RGB signaling circuit It has power supply for external components It can work as a receiver Works with safety band 03. THE CTROL BOARD Button to trigger the closing and scroll through the menus Button to trigger the opening and scroll through the menus MC111Y MODULE BUTTS CN4 Command (START button) 18 Input for START button. (Cycle: OP - STOP - CLOSE). 19 Input for pedestrian START button. Button to confirm / select programming menus 6A 6B

03. THE CTROL BOARD DIPPERS FUNCTIING 04. INSTALLATI ESSTIAL STEPS OFOR INSTALLATI DIPPER 1 DIPPER 2 DIPPER 3 automatic closure enabled automatic closure disabled Inverted by start button (CN4, input 18-20) during the enabled closure) Inverted by start button (CN4, input 18-20) during the disabled closure) Does not accept start (CN4, input 18-20) during opening and pause time Accept start (CN4, input 18-20) during opening and pause 01 Make the connections of all the accessories according to the wiring diagram (page 2). 02 Connect the control board to a power supply (terminals 1 and 2 - CN1). 03 Move the door manually up to the middle of the course and lock the motor. 04 LEDs 2, 3, 6 and 7 must be lit so that the door works properly, as they indicate the safety devices connection. In case of not using a security device, it is necessary to close the not used circuits with shunts. 05 Move the door (open and close) with the help of and. Adjust the limit switch until the respective LED turn off (10 or 11). RAPID DOOR SLIDE 4000 DIPPER 4 1 2 3 4 POSSIBLE INDICATIS THE DISPLAY Door / gate closed Door / gate closing Door / gate opening ERROR INFORMATI THE DISPLAY Blocked Short circuit 1 2 3 4 Open/start button (CN4, input 18-20) for opening Open/start button (CN4, input 18-20), open-stop-close The control board comes from factory with the dippers 1, 2 and 3 and the 4. 03. THE CTROL BOARD Door / gate open Automatic programming Stop DISPLAY INDICATIS High temperature Instant overcurrent Open: The LED 10 should turn off and the LED 11 should remain illuminated. Half course: The 10 and 11 LED remain lit. Closed: The LED 11 should turn off and the LED 10 should remain illuminated. Closed: The LED 11 should turn off and the LED 10 should remain illuminated. Half course: The 10 and 11 LED remain lit. Open: The LED 10 should turn off and the LED 11 should remain illuminated. COURSE PROGRAMMING: 01 Close the door (LED 11 should turn off). 02 Press the button repeatedly until TE in the display. 03 Press the START button (CN4, input 18-20) anda the door will open. 04 When the gate is 40 to 50 cm of the total opening, press the START button. 05 The door will slow down and stop when it reaches the opening limit switch. Wait the time you want for pause and press the start button again. 06 The door will start closing and when the gate is 40 to 50 cm of the total closure, press the START button. When it stops in the limit switch, the automatic programming is finished. Function settings failure Loading capacitors failure Overcurrent delayed Programmer overvoltage If LEDs do not go out as explained, it means that the cables from the limit switches are not well connected. Swap the terminal wire 26 with the 27. 7A 7B

FUNCTIS PROGRAMMING: 01 With the central plugged in, use / to navigate through the functions or moving the door / gate to adjustments. 02 To confirm any action, press. MU FUNCTI Industrial Roll-Up and Eco Doors / used values Used with Slide 4000 / used values MÁX. MIN. PROGRAMMABLE Select door type 0.1. 0.1. - 9A NOT USED (future use) Change pause time 1.0. 1.0. 1s 99s 9A 01 99 Adjust strength 9.9. 9.9. 9B 01 99 Opening frequency settings 5.0. 5.0. 9B min. min. min. max. max. max. PAGE 01 99 Closing frequency settings 3.5. to 4.0. 3.5. to 4.0. 10A min. max. 01 99 Deceleration frequency during the opening 2.5. 2.5. 10A min. max. LEAVE PROGRAMMING: 01 99 Deceleration frequency during the closing 2.0. to 2.5. 2.0. to 2.5. 10B min. max. If you want to leave the programming mode, press / to find E. S. Press to confirm. Amperometric sensitivity (opening) Amperometric sensitivity (closure) Deceleration amperometric sensitivity (opening) Deceleration amperometric sensitivity (closure) Yes / 4.5. - 10B Yes / 4.5. - 11A Yes / 3.5. - 11A Yes / 3.5. - 11B 0.1 2.0 Startup acceleration time 0.5. 0.5. 11B min. max. Closing strike Enable test function - - 12A Count maneuvers Yes Yes - 12A Present man Optional Optional - 12B Escape (exit the menu) Yes Yes 8

SELECT DOOR TYPE ADJUST STRGTH This function lets you select the automation type (AC motor AC), to which the center will work, knowing that: This function allows to adjust the operating force of the motor when opening and closing. Sliding gate/rapid door DO NOT USE - other motors DO NOT USE - other motors 01 Press until 0.1 appear 02 Press to enter the 01 Press until 0.1 appear 02 Press repeatedly until 0.4 appears. 03 It appears 0.3 on the display (value set in production). Uses / to change it to 01. 04 Press to confirm. This function is already configured properly. Do not make changes to the default value. If you enter this function, leave and reprogram the function 0.1. 03 Press to enter the stored value. Use / if you want to change the value. 05 Press to confirm the value. To program 0.5. menu 0.5. (page 9B). ALTERAR CHANGE TEMPO PAUSE DE PAUSA TIME OPING FREQUCY The pause time is the time (in seconds), the door will remain open after performing the opening. In the end of this time, the door automatically closes. (Factory default 10) 01 Press until 0.1 appear 02 Press repeatedly until 0.3 appears. This function is to adjust the opening speed. The value shown on the display is in HZ. See table on page 5A. 01 Press until 0.1 appear 02 Press repeatedly until 0.5 appears. 03 Press to enter the stored value. Use / if you want to change the time. 05 Press to confirm the time. To program 0.4. continue with step 3 from the menu 0.4. (page 9B). 03 Press to enter the 04 The display shows the memorized frequency. Use / if you want to change the frequency. 05 Press to confirm the frequency. To program 0.6. menu 0.6. (page 10A). 9A 9B

CLOSURE FREQUCY DECELERATI FREQ. DURING THE CLOSURE This function is to adjust the closing speed. The value is shown on the display in HZ. This function is to adjust the idle speed in the closure. The value is shown on the display in HZ. See table on page 5A. See table on page 5A. 01 Press until 0.1 appear 02 Press repeatedly until 0.6 appears. 01 Press until 0.1 appear 02 Press repeatedly until 0.8 appears. 03 Press to enter the memorized frequency. Use / if you want to change the frequency. 05 Press to confirm the frequency. To program 0.7. menu 0.7. (page 10A). 03 Press to enter the memorized frequency. Use / if you want to change the frequency. 05 Press to confirm the frequency. To program 0.9. menu 0.9. (page 10B). DECELERATI FREQ. DURING THE OPING AMPEROMETRIC SSIBILITY (OPING) This function is to adjust the idle speed in the opening. The value is shown on the display in HZ. See table on page 5A. This function is to adjust the motor's effort sensitivity in the opening. 00 - Cancels sensitivity 01 - High sensitivity 09 - Low sensitivity 01 Press until 0.1 appear 02 Press repeatedly until 0.7 appears. 01 Press until 0.1 appear 02 Press repeatedly until 0.9 appears. 03 Press to enter the memorized frequency. Use / if you want to change the frequency. 05 Press to confirm the frequency. To program 0.8. menu 0.8. (page 10B). 03 Press to enter the memorized value. Use / if you want to change the sensitivity. 05 Press to confirm the sensibility. To program 1.0. menu 1.0. (page 11A). 10A 10B

AMPEROMETRIC SSIBILITY (OPING) DECELERATI AMP. SSIBILITY (CLOSING) This function allows to adjust the motor's effort sensitivity in the closing. 00 - Cancels sensitivity 01 - High sensitivity 09 - Low sensitivity 01 Press until 0.1 appear 02 Press repeatedly until 1.0. appears. This function allows to adjust the motor's effort sensitivity during the closing deceleration. 00 - Cancels sensitivity 01 - High sensitivity 09 - Low sensitivity 01 Press until 0.1 appear 02 Press repeatedly until 1.2. appears. 03 Press to enter the memorized value. Use / if you want to change the sensitivity. 05 Press to confirm the sensibility. To program 1.1. menu 1.1. (page 11A). 03 Press to enter the 04 The display shows the memorized value. Use / if you want to change the sensitivity. 05 Press to confirm the sensibility. To program 1.3. menu 1.3. (page 11B). DECELERATI AMP. SSIBILITY (OPING) ACCELERATI RAMP This function allows to adjust the motor's effort sensitivity during the opening deceleration. 00 - Cancels sensitivity 01 - High sensitivity 09 - Low sensitivity 01 Press until 0.1 appear 02 Press repeatedly until 1.1. appears. This function allows the soft start time adjustment. 1.0. = 1 second 0.5. = half second (Recommended value 0.5) 01 Press until 0.1 appear 02 Press repeatedly until 1.3. appears. 03 Press to enter the memorized value. Use / if you want to change the sensitivity. 05 Press to confirm the sensibility. To program 1.2. menu 1.2. (page 11B). 03 Press to enter the memorized value. Use / if you want to change the value. 05 Press to confirm the value. 11A 11B

This function is already configured properly. Do not make changes to the default value (O). PREST MAN ABLE TESTING FUNCTIS This function allows you to enable automatic movements for testing. (Recommended value 0) With this function active, the motor runs only if you hold down the push button. 01 Press until 0.1 appear 02 Press repeatedly until 1.5. appears. 01 Press until 0.1 appear 02 Press repeatedly until 1.7. appears. 03 Press to enter the memorized value. Use / if you want to change the function. 05 Press to confirm the sensibility. To program 1.6. menu 1.6. (page 12A). 03 Press to enter the 04 The display shows SI or NO. Use / if you want to change the function. 05 Press to confirm the selected function. MANEUVERS COUNTING This menu allows you to check how many complete maneuvers were performed by the control board (complete maneuver is meant by opening and closing). The control board reset does not erase the maneuvers counting. 01 Press until 0.1 appear 02 Press repeatedly until 1.6. appears. display blinks display blinks 03 Press to enter the 1º hundreds of thousands 2º thousands 3º tens count of the maneuvers in the order shown in the picture above (the example shows 13,456 maneuvers). 12A 12B

06. TROUBLESHOOTING INSTRUCTIS FOR CSUMERS / TECHNICIANS Anomaly Procedure Behavior Procedure II Discovering the origin of the problem Door/motor doesn't work Make sure you have power supply connected to operator and if it is working properly. Still not working Consult a qualified MOTORLINE technician. 1 Open control box and check if it has power supply; 2 Check input fuses; 3 Disconnect door from control board and test them by connecting directly to power supply in order to find out if they have problems (see page 11.A). 4 If the door works, the problem is on the control board. Pull it out and send it to our MOTORLINE technical services for diagnosis; Door/motor doesn t move but makes noise Unlock door and move the gate/ tarpaulin by hand to check for mechanical problems on the movement Encountered problems? O The gate/ tarpaulin moves easily? Consult a qualified MOTORLINE technician. Consult a qualified MOTORLINE technician. 1 Check all motion axis and associated motion systems related with the gate/motor (wheels, racks, etc.) to find out what is the problem. 1 If the motor works, the problem is from control board. Pull it out and send it to our MOTORLINE technical services for diagnosis; 2 If the motor doesn t work, remove them from installation site and send to our MOTORLINE technical services for diagnosis. Door/motor opens but doesn t close Unlock motor and move gate/tarpaulin by hand to closed position. Lock motor again and turn off power supply for 5 seconds. Reconnect it and send order to open door using transmitter. Door/motor opened but didn t close again 1 Check if there is any obstacle in front of the photocells; 2 Check if any of the control devices (key selector, push button, video intercom, etc.) of the door/gate are jammed and sending permanent signal to control unit; 3 Consult a qualified MOTORLINE technician. All MOTORLINE control boards have LEDs that easily allow to conclude which devices are with anomalies. All safety devices LEDs (DS) in normal situations remain On. All "START" circuits LEDs in normal situations remain Off. If LEDs devices are not all On, there is some security systems malfunction (photocells, safety edges), etc. If "START" circuits LEDs are turn On, there is a control device sending permanent signal. A) SECURITY SYSTEMS: 1 Close with a shunt all safety systems on the control board. If the automated system starts working normally check for the problematic device. 2 Remove one shunt at a time until you find the malfunction device. 3 Replace it for a functional device and check if the motor works correctly with all the other devices. If you find another one defective, follow the same steps until you find all the problems. B) START SYSTEMS: 1 Disconnect all wires from START terminal input. 2 If the LED turned Off, try reconnecting one device at a time until you find the defective device. NOTE: In case procedures described in sections A) and B) don t result, remove control board and send to our technical services for diagnosis. Door/motor doesn t make complete route Unlock the motor and move gate by hand to check for mechanical problems. Encountered problems? Gate/door moves easily? Consult a gate specialized technician. Consult a qualified MOTORLINE technician. 1 Check all motion axis and associated motion systems related with the gate/motor (wheels, racks, etc.) to find out what is the problem. 1 If the motor doesn t work, remove it from installation site and send to our MOTORLINE technical services for diagnosis. 2 Set the force on the control board. Program the motor's working time again assigning the required time and appropriated force for opening and closing. 3 If this doesn t work, remove control unit and send it to MOTORLINE technical services services. NOTE: Setting force of the controller should be sufficient to make the door open and close without stopping, but should stop and invert with a little effort from a person. In case of safety systems failure, the door shall never cause physical damaged to obstacles (vehicles, people, etc.). 13