Similar documents
LED Driver Compact fixed output

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED Driver Compact fixed output

LED Driver Compact fixed output

LED control gear Compact fixed output

LED Driver Compact dimming

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Emergency lighting units EM powerled

Emergency lighting units EM powerled

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

LED Driver Compact dimming

LED Driver Linear / area dimming

LED Driver Compact dimming

LED Driver Constant voltage

LED Driver Compact dimming

LED Driver Compact dimming

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

OT 100/ /700 P5

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

OPTOTRONIC Intelligent

HID control gear Electronic

PHASED OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM chronostep PCI outdoor

Technical Information

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

LED MODULES READYLINE DL

DALI TOUCHPANEL BASIC TW. Operating and control unit

Indoor Linear 80W Driver SI-C215280N2KR

PHASED OUT. Emergency lighting units EM INVERTER. EM MINI BASIC, V 50/60 Hz BASIC version

Emergency lighting units EM INVERTER

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

OPTOTRONIC FIT. Product family datasheet. Linear / Area Constant Current Non dimmable. Areas of application. Product benefits.

Operating instructions

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

02/11/2015

Catalogue Ignitors and power switches for HID

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

AS09..S 3-pole Contactors - Spring Terminals

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Figure 1: Device components

Engineering Design Assurance Test Report ( Dual & Triple ) MODEL: SPS-100P-D2 V1 5 V 12 Amax

architecture mounting Features Product lighting

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

KRF EMC Filters Installation, Operation and Maintenance Manual

Linear flow controls VFC Linear flow controls with actuator IFC

TOSHIBA Industrial Magnetron E3328

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

Series CT7N Bimetallic Overload Relays

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Linear flow control with actuator IFC

Magnetic Sensor - Incremental EHP

Gamma instabus. Technical product information

Datasheet - SRB-E-201ST

Product Data Sheet 4656 ZW

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Absolute Rotary Encoder E6CP

Process Transmitter RMA 422

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Modular pulse operated latching relay 16 A

ODW-621. RS-232 Point-to-point applications

Filters for Power Lines (Low Leakage Current)

Type: DILM25 10(24V50HZ) Article No.:

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Process transmitter RMA422

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

15 Series - Dimmer

Kuhnke Technical Data. Contact Details

PRINCIPLES AND APPLICATIONS

10 PDUs 19 PDUs Zero-U PDUs

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

Product Data Sheet 4656 EZ

HELVAR. CONTROLLABLE ELECTRONIC BALLASTS DALI & 1-10 V controllable ballasts STANDARD ELECTRONIC BALLASTS

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

QSNE-4S5-230-D V~ 50 / 60 Hz 16 A. Dimming Power Module CCI. Option Def. Input. H Opt1. Hi Temp Prog Power

Selenium LED simply efficient

Ø50mm Shaft Multi-Turn Absolute Type

Benefits. Applications

Selenium LED simply efficient

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Transcription:

Driver LC 10W 350mA fixc lp SNC2 ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 350 ma Max. output power 10.2 W Up to 80 % efficiency For luminaires of protection class I and protection class II Temperature protection as per EN 61347-2-13 C5e Nominal life-time up to 50,000 h 5-year guarantee Properties Casing: polycarbonate, white Type of protection IP20 Functions Overload protection Short-circuit protection No-load protection È Standards, page 3 Wiring diagrams and installation examples, page 4 www.tridonic.com 1

Driver LC 10W 350mA fixc lp SNC2 ESSENCE series Technical data Rated supply voltage 220 240 V AC voltage range 198 264 V Input current (at 230 V, 50 Hz, full load) 0.06 A Leakage current (at 230 V, 50 Hz, full load) < 450 µa Mains frequency 50 / 60 Hz Output power range 4.9 10.2 W THD (at 230 V, 50 Hz, full load) < 15 % Output current tolerance 3 ± 7.5 % Output LF current ripple (< 120 Hz) at full load ± 10 % Turn on time (at 230 V, 50 Hz, full load) 0.5 s Turn off time (at 230 V, 50 Hz, full load) 0.5 s Hold on time at power failure (output) 0 s Ambient temperature ta -20... +50 C Ambient temperature ta (at life-time 50,000 h) 50 C Storage temperature ts -40... +80 C Mains burst capability (between L N) 1 kv Mains surge capability (between L N) 1 kv Mains surge capability (between L/N PE) 2 kv Surge voltage at output side (against PE) 3 kv Dimensions L x W x H 145 x 22 x 21 mm Hole spacing D 132.8 mm 11 Ordering data Type 145 132,8 Article number tc tc carton 64,5 low volume 21 4,2 22 high volume Weight per pc. LC 10/350/29 fixc lp SNC2 87500778 25 pc(s). 1,250 pc(s). 8,750 pc(s). 0.043 kg Specific technical data Type Output current 3 Max. input power Typ. power consumption (at 230 V, 50 Hz, full load) λ at full Efficiency at full λ at min. Efficiency at min. Min. forward voltage 1 Max. forward voltage 1 Max. output voltage (U-OUT) Max. peak output current at full 2 Max. casing temperature tc LC 10/350/29 fixc lp SNC2 350 ma 13 W 12.6 W 0.9C 80 % 0.8C 71 % 14 V 29 V 42 V 411 ma 90 C 1 Test result at 230 V, 50 Hz. 2 The trend between min. and full load is linear. 3 Output current is mean value. www.tridonic.com 2

1. Standards 3.4 Wiring guidelines EN 55015 EN 61000-3-2 EN 61000-3-3 EN 61347-1 EN 61347-2-13 EN 61547 EN 62384 1.1 Glow-wire test according to EN 61347-1 with increased temperature of 850 C passed. 2. Thermal details and life-time 2.1 Expected life-time Expected life-time Type ta 40 C 50 C 60 C LC 10/350/29 fixc lp SNC2 tc 80 C 90 C x Life-time 100,000 h 50,000 h x 3.6 Mounting of device All connections must be kept as short as possible to ensure good EMI behaviour. Mains leads should be kept apart from LED Driver and other leads (ideally 5 10 cm distance) Max. lenght of output wires is 2 m. Incorrect wiring can damage LED modules. To avoid the damage of the Driver, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.). 3.5 Replace LED module 1. Mains off 2. Remove LED module 3. Wait for 30 seconds 4. Connect LED module again Hot plug-in or output switching of LEDs is not permitted and may cause a very high current to the LEDs. The LED Driver is designed for a life-time stated above under reference conditions and with a failure probability of less than 10 %. Max. torque for fixing: 0.5 Nm/M4 3. Installation / wiring 3.1 Circuit diagram 220 240 V 50/60 Hz L N PRI SEC + LED LED 3.2 Wiring type and cross section The wiring can be stranded wires with ferrules or rigid wires with a cross section of 0.5 1.5 mm². Strip 8.5 9.5 mm of insulation from the cables to ensure perfect operation of the push-wire terminals (WAGO 250). wire preparation: 0.5 1.5 mm² 8.5 9.5 mm 3.3 Release of the wiring Press down the push button and remove the cable from front. www.tridonic.com 3

4. Electrical values 4.1 Efficiency vs load 82 80 4.4 Input current vs load 65 60 Efficiency [%] 78 76 74 Input current [ma] 55 50 45 40 72 35 70 30 4.2 Power factor vs load 0,94 4.5 THD vs load (without harmonic < 5 ma or 0.6 % of the input current) THD without harmonic < 5 ma (0.6 %) of the input current: 9,0 0,92 0,90 8,5 Power factor 0,88 0,86 0,84 THD [%] 8,0 7,5 0,82 7,0 0,80 6,5 4.3 Input power vs load 13 12 Input power [W] 11 10 9 8 7 6 www.tridonic.com 4

4.6 Maximum loading of automatic circuit breakers Automatic circuit breaker type C10 C13 C16 C20 B10 B13 B16 B20 Inrush current Installation Ø 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 Imax Time LC 10/350/29 fixc lp SNC2 120 160 200 240 100 130 160 200 8 A 60 µs 4.7 Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in % THD 3. 5. 7. 9. 11. LC 10/350/29 fixc lp SNC2 < 15 < 12 < 10 < 7 < 5 < 5 Acc. to 6100-3-2. Harmonics < 5 ma or < 0.6 % (whatever is greater) of the input current are not considered for calculation of THD. 5. Functions 5.1 Short-circuit behaviour In case of a short circuit on the secondary side (LED) the LED Driver switched off. After elimination of the short-circuit fault the LED Driver will recover automatically. 5.2 No-load operation The LED Driver works in burst working mode to provide a constant output voltage regulation which allows the application to be able to work safely when LED string opens due to a failure. 5.3 Overload protection If the output voltage range is exceeded the LED Driver will protect itself and LED may flicker. After elimination of the overload, the nominal operation is restored automatically. 6. Miscellaneous 6.1 Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an isolation test with 500 V DC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals. The isolation resistance must be at least 2 MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic devices this test must not be conducted. 6.2 Conditions of use and storage Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %) Storage temperature: -40 C up to max. +80 C The devices have to be within the specified temperature range (ta) before they can be operated. 6.3 Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services Life-time declarations are informative and represent no warranty claim. No warranty if device was opened. www.tridonic.com 5