Theater De Meervaart Amsterdam Red Hall (Rode Zaal) and Blue Hall (Blauwe zaal)

Similar documents
de oosterpoort groningen main hall

Technical Rider. STAGE 32 m wide x 13 m deep (from the prompt)

TECHNICAL RIDER. STAGE 32 m wide x 13 m deep (from setting line / mid point)

FASO DANCE COMPANY KALAKUTA REPUBLIK

PRELIMINARY TECHNICAL RIDER - LITTLE RED RIVER

Main House Technical Specification

TECHNICAL RIDER. If you have problems to fulfil some of our demands, please don t hesitate to contact us. We will find a solution!

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

LOAD IN / LOAD OUT CARS / SPLITTER VAN / NIGHTLINER THROUGH MAIN ENTRANCE SITUATED AT AUGUSTE ORTSSTRAAT 20-28, 1000 BRUSSEL.

TOURING RIDER Where Magic & Motion Meet!

TECH SHEET AND INFORMATION (Updated )

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

There are 2 dressing rooms dedicated to the RABOzaal. Each room has at least 1 hand basin.

Theatre Technical Specifications

Downtown Arts Center Tech Packet. General Information

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

There are 10 dressing rooms in Theatre Kerkrade.

Barney Simon Theatre Technical Specifications

Dr JOHN GALLAGHER CONCERT CHAMBER

Small Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Technical Specifications and Inventory Spring 2018

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

THE CLASSIC GRAND 18 JAMAICA STREET GLASGOW G1 4QD

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

MAIN STAGE GENERAL INFO AND FACILITIES

SHIVER. Technical rider update : 10th feb Premiere at Theater l Arsenic in Lausanne/Suisse the 4th of february 2014

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

ISLAND HALL TECHNICAL INFORMATION

v. 2.4 Address: Musikhuset Posten Østre Stationsvej 35 DK-5000 Odense C Booking/management: Morten Østlund

HIRE AND TECHNICAL INFORMATION

DEREHAM MEMORIAL HALL

A38 SHIP CONCERT HALL TECHNICAL RIDER 2018!

JERWOOD VANBRUGH THEATRE

Main Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

TECHNICAL REQUIREMENTS

Technical Data Sheet

Technical Information

HUECO / Technical Rider

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

THE STREET THEATRE. Technical Specifications

UNIVERSITY CONCERT HALL. Technical Specification

University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts

Jane Mallet Theatre Technical Specifications

Technical Specifications. Taylor Little Theater

Technical Information

TECHNICAL RIDER FOR GROUND FREIGHT-TOURING

The Breen Center for the Performing Arts Saint Ignatius High School

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Information for Incoming Companies

Sandusky State Theatre Technical Specifications

Little River Band Production Rider 2018

Live From Nashville TECHNICAL RIDER

Visy Theatre technical information and general specifications 2019

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Technical Specification Pavilion Dance

Project manager (PM): Pamela Næss Mail: Phone:

SHUBERT THEATER 247 College Street, New Haven, CT

Studio 180. Electronic and Print versions of the venue ground plan are available from the Technical Director.

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Technical specifications - Compagnie José Besprosvany Prométhée enchaîné

2017 TECHNICAL SPECIFICATIONS

Hopgood Theatre NOARLUNGA CENTRE

TECHNICAL REQUIREMENT FORM

Contents. 1. Contacts. 2. Directions & Transport Links 2.1. Address 2.2. Local Map & Directions 2.3. Public Transport

Technical Specification

Section I: Renter Information

Matt Dann Cultural Centre

Project manager (PM): Pamela Næss Mail: Phone:

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Personal data Technical coordination Pernel van Herpt

Technical Rider. Update: may 6th 2008

Kenny Rogers Productions, Inc Production Requirements Indoor and Outdoor and Small Venue Performances

UTC McKenzie Arena Technical Pack

Tickets will be sold through our ABC account and all tickets are scannable on entry.

mainstage or theatercafe, on demand on demand 103 dba at FOH 6x4x1 meter (if needed bigger) + stairs Max. 4x drumriser (2x1x0,5 meter) No Yes

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

TECHNICAL RIDER FOR THEATER (rev. 1/2/18)

Technical Specifications Updated 01/10/2017. Stage

DOMINO THEATRE INC. THEATRE TECHNICAL SPECIFICATIONS AND INFORMATION

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Arcadia Performing Arts Center Technical Specifications and Information

Powerhouse Theatre technical information and general specifications 2017

Technical Services and Specification

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

Technical requirements & conditions for hirers

T1 National Theater. Auditorium (Basement 1): 324 Under Balcony (Ground floor): 388 Royal Circle (Level 1): 161 Level 2: 316 Level 3: 422

CIVIC THEATRE CONFERENCE BROCHURE 2018 TALLAGHT, DUBLIN 24

James Clemens High School

TECHNICAL RIDER FOR THEATER (rev. 11/30/17)

RIDER C: TECHNICAL RIDER TO CONTRACT

Marist Auditorium. Facility Guide

Technical Specification for the Alley Theatre, Strabane

Les Docks / Av. de Sévelin Lausanne. Technical Rider

Transcription:

Theater De Meervaart Amsterdam Red Hall (Rode Zaal) and Blue Hall (Blauwe zaal) General info Theater de Meervaart. De Meervaart is a large modern theater, studio and congres centre in Amsterdam New-West nearby de Ring Amsterdam A10. Easy accessible by car & public transport. The Meervaart has two Theatre auditoria. The Red Hall with a capacity of 800 seats and the Blue Hall, 250 seats. For images or a virtual 360 degrees tour please check our website www.meervaart.nl Address Meer en Vaart 300 1068 LE Amsterdam, The Netherlands Phone Phone + 31 (0)20 4107700 Fax + 31 (0)20 4107789 E-mail info@meervaart.nl Website www.meervaart.nl Contacts Tickets Phone 020-410 77 77 Mo-Sat 12.00-16.30 uur And one hour before showtime kaartverkoop@meervaart.nl

Congress / sales / catering Phone 020-410 77 20 Fax 020-410 77 90 sales@meervaart.nl Programming Phone 020-410 77 08 Andreas Fleischmann afleischmann@meervaart.nl PR and Marketing telefoonnummer 020-410 77 13 pr@meervaart.nl Technical (Theatre) Phone 020-410 77 27 Eric Schlaghecke techniek@meervaart.nl Facilitary services Phone 020-410 77 16 Martijn Doornhein mdoornhein@meervaart.nl kamer van koophandel nummer 33157489 btw nummer 0034.14.218.b.01 Loading docks: General info Loading Docks: Meer en Vaart 300 (Loading and Unloading) There are no long term parking facilities. No backstage parking. Trucks can park next to Talentenhuis (4 minute walk) Meer en Vaart 290 1068 LE Amsterdam Loading dock Red Hall (Rode Zaal) Adress: Meer en Vaart 300 2 loading docks situated at stage right. Doors: 2,8m x 3.95m.

No levelers available Stage level +0,6m. On the ground floor of our building Loading and Unloading: ramps available Loading dock Blue Hall (Blauwe Zaal) 1 loading dock situated at stage left. Doors: 2m x 2m No levelers available Stage level: on the first floor of our building Loading and Unloading: ramps available All equipment has to be unloaded onto a special elevator (size 2,4 x 4,0 meter) Car Parking: Name: Q-Park Osdorpplein Osdorpplein 249 1068 ER Amsterdam 09002357275 Max. Height 1,95 meter Parking fee 24H Reduced parking-fee tickets available at our reception desk during their opening hours.

Red Hall: Stage Stage size: 15m wide x 10m deep (excluding borders and legs) Flying facilities: 36 Flybars (TNM/Trekwerk, max 300kg max 17,5meters) Stage height 1.1 m. Risers/ rolling risers (stage decks 2x 1m): available on request. Please contact us about rigging / hanging possibilities. Stage power supply Lights: 2 x 3 x 125A 3ph (5 pin CEEform) Sound: 2 x 3 x 32A 3ph (5 pin CEEform) Sound limit Due to sound level restrictions and regulations it is not allowed to exceed the following maximum sound level: Max 103 dba at the FOH sound desk, Leq 15 minutes. De Meervaart reserves the right to reduce the sound level when necessary. Backline We will presume artist will carry all backline unless otherwise agreed. In case De Meervaart will have to rent backline (extra cost for account of the artist), we will need specific backline requirements well in advance.

Grand piano: A grand piano (Yamaha C 7) can be provided by the venue. Extra costs for tuning will be for account of the artist. backstage situation Dressing rooms 5 dressing rooms (with showers and toilets). Dressing rooms are situated on the ground floor. All dressing rooms are lockable and are furnished with tables, chairs, mirrors, adequate lighting, poweroutlets and a clothes rack. Production office 1 production office. Production phone: available on request. Wifi available. Rode Zaal / Red Hall Technical: SOUND: PA/FRONT OF HOUSE : Meyer Sound: 4xSub 600HP 6xCQ1 2xUPA (Cluster) MONITORS Meyer Sound: 4 UM100P wedges

2 UM1P wedges MICROPHONES To be announced Power supply sound: 1x 32A 3 ph + G + N (Stage left OR stage right) lighting specs 2018 main hall/ grote zaal Conventional lighting 6 Sixbars PAR 64 MFL (CP62), 1 kw 10 1kW Profile Zoomspots (various types) 10 2kW PC spots (various types) Front lighting Front bridges with large set of fixed spots (please see lightplot) Dimming 40 channels 16A/ 2kW (5 x Harting 16 Stage Left) Toneel rechts 8 channels 16A/ 2kW (1 x Harting 16 Stage Right) Toneel links All bridges (fixed light fixtures) have their own dimmers Moving heads (Always at extra costs for the organizers!) Other To be announced Swefog Ultimate 200 hazer + AF1 fan, DMX-controllable All gels are LEE and gobos are A-size All DMX is 5 pin connectors

Controls Compulite SparkTop Compulite Vector Orange / Blue 3 x DMX lines FOH-Stage Right (5 pin connectors) Videoprojection: (Always at extra costs for the organizers!) One Barco W8 HD video projector 8000 Ansli Lumen. Fixed Position, rear projection on projection screen. Input SDI or HDMI.

Blue Hall: Hall: 22 x 13,5m Stage Stage size: 11m wide x 10m Flying facilities: 10 Flybars (fixed speed, max 8m) Fixed brigdes ca 6,2 m Stage height 0.0 m.. Risers / rolling risers (stage decks 2x 1m): available on request. Please contact us about rigging / hanging possibilities. 14 Flybars and trusses: max 150kg Single speed, manual/yellowbox operated. Stage power supply Lights: 1 x 3 x 125A 3ph (5 pin CEEform) Sound: 1 x 3 x 32A 3ph (5 pin CEEform) Sound limit Due to sound level restrictions and regulations it is not allowed to exceed the following maximum sound level: Max 103 dba at the FOH sound desk, Leq 15 minutes. De Meervaart reserves the right to reduce the sound level when necessary. Backline We will presume artist will carry all backline unless otherwise agreed. In

case De Meervaart will have to rent backline (extra cost for account of the artist), we will need specific backline requirements well in advance. Grand piano: A grand piano (Steinway type B) can be provided by the venue. Extra costs for tuning will be for account of the artist. Videoprojection: (Always at extra costs for the organizers!) One Barco W8 HD video projector 8000 Ansli Lumen. Fixed Position, front projection on cinemascreen or cyclorama. Input SDI or HDMI. backstage situation Dressing rooms 2 dressing rooms (with showers and toilets). Dressing rooms are situated on the same floor as the stage. All dressing rooms are lockable and are furnished with chairs, mirrors, adequate lighting, poweroutlets and a clothes rack. Production office No. Blauwe Zaal / Blue Hall Technical: FRONT OF HOUSE : Meyer Sound: 2xSub 600 HP 4xCQ1 MONITORS 4 x-act

Midas Venice F24 MICROPHONES To be announced Power supply sound: 1x 32A 3 ph + G + N (stage left) lighting specs 2018 Conventional lighting 4 x PAR 64 sixbars MFL (CP 62), 1kW 8 x zoom profiles incl. iris etc. (4 x Robert Juliat 1kW / 4 x SourceFour 750W) 8 x Robert Juliat PC, 1 kw 8 x Robert Juliat Fresnel 1 kw Front lighting Front bridges with large set of fixed spots (please see lightplot) Dimming 40 channels 16A/ 2kW (5 x Harting 16 Stage Right) Toneel links All bridges (fixed light fixtures) have their own dimmers Moving heads: None Other All gels are LEE and gobos are A-size All DMX is 5 pin connectors Controls Compulite Photon 144 channels Compulite Spark 4D Compulite Vector Orange 2 x DMX lines FOH-Stage Right (5 pin connectors) Intercom: ASL (wired) on request.

General backstage and technical information: No Smoking Smoking is not allowed in the building, and loadingdocks at all times. There is one smokersroom near the Red Hall stage area (groud floor). Fire Proof Certificates and Restrictions There are strict regulations governing the use of pyrotechnical devices, smoke and fire effects on stage. Please contact venue s production manager well in advance if your production involves anything like this. All scenery, back drops etc. must be flameproof and comply with all Dutch fire and safety regulations. The use of any kind of confetti, snow, glitter, foam or bubble machines is not allowed, unless otherwise agreed well in advance. Green Room (Artiestenfoyer) Situated on the first floor. Drinks are available for cast and crew. Free use of microwave. If you have any questions regarding catering or hospitality, do not hesitate to contact venue s sales manager. (sales@meervaart.nl) Wifi / internet Free wireless internet available in the whole building Network: meervaart Password: none Merchandise fee and Merchandise seller or assistant: Please contact sales@meervaart.nl Hotel accommodation: If you need hotel accommodation, we can assist with your reservation. Do not hesitate to contact us. sales@meervaart.nl

important notices Please make sure we receive all relevant show information no later than 6 weeks before the day of performance: Please send to techniek@meervaart.nl technical rider, including stage plot and patchlist lighting plot hospitality rider backline: we will presume artist will carry all backline unless otherwise agreed travel party technicians group will bring means of transportation Please contact venue s production manager 6 weeks in advance to the show to discuss the number of crew needed. Please report any changes regarding get in time a.s.a.p. to venue. at least 4 days before the day of performance. Extra costs due to changes after this date may be for account of the artist. De Meervaart venue is obliged to work according to the Dutch occupational health and safety regulations determined by the Dutch Labour Inspectorate. We expect you to do the same. De Meervaart stage dept. works according to the general agreement of the VSCD. (Mantelovereenkomst van de VSCD Nederlandse Vereniging van Schouwburg en Concertzaal Directies). This means: De Meervaart does not supply more technical crew as the number of visiting technical crew. Extra crew will be charged to the account of the artist. All riders received after aforementioned time span shall be dealt with in the best possible way, without any guarantees as to their fulfillment. All extra costs resulting from this will be charged. Please note: Check www.meervaart.nl for an updated version. Contact us well in advance (at least 6 weeks before show) if these specs are not sufficient! If you have any questions regarding sound or lights, please contact: techniek@meervaart.nl, or Eric Schlaghecke (0204107727)

Samenvatting: Basis theatertechniek Blauwe Zaal / Rode Zaal Opbouw vanaf 13 uur (werkdag tot ca 24 uur) Standaard zaal en tribune opstelling Lunch 1230-1300 / diner 1700-1900 2 Meervaart technici: (1 licht 1 geluid) Standaard lichtplan bestaande uit Front en tegenlicht geen moving heads Basis geluidstechniek : Mengtafel in de cabine of zaal (geen aparte monitormix) beperkt aantal microfoons instarts van CD s of andere media. Beperkt aantal monitors op toneel. Indien video gebruikt wordt: alle instarts e.d. worden door de gebruiker gedaan vanaf het zijtoneel Alle extra s: Mankracht en Apparatuur wordt doorberekend. Summary technical rider: Work hours: 13:00-24:00, including breaks for Lunch 12:30-13:00 and Dinner 17:00-19:00) Standard House seating plan 2 house technicians: 1 sound and 1 lights tech. Basic lightplot with front and backlights. Movingheads and special effectlights are not included. Basic sound. Mixing console in booth or in the house. No separate monitormix. Limited number of microphones. CD players etc. Limited number of Monitors on stage. When using our videoscreens: Switching etc is done off stage by the organizer. Extra s: Labour and Materials will be charged to the organizers.