MB5 Multibeam Activity Monitor

Similar documents
TRIKINETICS TriKinetics Inc USA 1/ DAMSystem Product Price List

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

Safety Precautions and Maintenance

Part names (continued) Remote control

User Manual 15" LCD Open frame SAW Touch Monitor KOT-0150US-SA4W. Table of Contents

Instromet Weather Systems Ltd

Operating Instructions

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

Dual Antenna Wireless Multi-Channel Expandable HDMI Extender Installation Guide

28 4K LED monitor. User Manual M284K

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

PNP300 & PNP350 POP N PLUG SLIM INTERCONNECT BOX USER S GUIDE

Full HD Multi-Channel Expandable Wireless HDMI Gateway Extender

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

P-2 Installing the monitor (continued) Carry out as necessary

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

27'' Full HD LED Monitor KALED27MONSC Quick Start Guide

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

Camera 220C Document Camera User s Guide

USER MANUAL Full HD Widescreen LED Monitor L215ADS

SPACESCAN SERIES SS 02

USER MANUAL Full HD Widescreen LED Monitor L215IPS

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Checking the fluids of the cart

Wireless 1080P HDMI Video Kit - Mid-Range

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

Intelligent Security and Fire Ltd

USER MANUAL Full HD Widescreen LED Monitor L236VA

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

PLL1920M LED LCD Monitor

NO PICTURE - Black Screen, No picture, No image, blank screen. ABNORMAL COLORS - Distorted picture, fuzzy picture, distorted colors

COLOR TFT LCD MONITOR. Manual

PYROPTIX TM IMAGE PROCESSING SOFTWARE

MONOPRICE. Blackbird 4K HDBaseT Extender Kit. User's Manual P/N 21792

USER MANUAL. Kramer Electronics, Ltd. Models:

HD Video Capture Pro

TP /351 HDMI Over Coax with IR

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

DA1931CT/ TP to Video + Audio Receiver

Introduction...2. Features...2 Safety Precautions...2. Installation...4

42 Freestanding Infrared Multi Touch Screen Kiosk User s Manual

22" Touchscreen LED Monitor USER'S GUIDE

TP HDMI OVER ANYWIRE TRANSMITTER

Transmitter Interface Program

Table of Contents Precautions... 2

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

USER GUIDE 3. For more information visit

Translator VGA to HDMI

Data Acquisition Using LabVIEW

Reference WIRING THE SYSTEM TOGETHER. Page 4-1 TWO OR MORE RECEIVERS

Remote Control. degraded, causing unreliable operation. The recommended effective distance for remote operation is about 16 feet (5 meters).

TransitHound Cellphone Detector User Manual Version 1.3

Computer Graphics: Overview of Graphics Systems

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

feno before light and beyond

Marshall Electronics. Pro A/V Communications VMV-402-SH. 3G/HD/SD-SDI Quad-viewer/Switcher with Audio Meter Display. User Manual.

CELLO SETUP WITH WinGPS CelloSetup_WinGPS(15.9).doc September 17, Contents

VMA ACTIVE MATRIX TFT COLOR LCD MONITOR OWNER S MANUAL INSTALLATION GUIDE

PLL2210MW LED Monitor

VIDEO GRABBER. DisplayPort. User Manual

Blackbird 1x4 HDMI Splitter for TV Walls

PL2410W LCD Monitor USER'S GUIDE.

Stark Spectroscopy Deanna s Experimental Procedure NWU Hupp Lab Fall 2003

Weschler AMT Software for the Enhanced Version Transformer Advantage

TP HDMI OVER ANYWIRE RECEIVER (DC)

Pulse Biomedical QRS-Card Tango M2 Interface Notes

SMART CLASSix 48 UTP Patch Panels (with patching switches) -

DVB-C20. Compatible with navigation systems Mercedes Benz Comand 2.0 Comand APS CD Comand APS 220

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

Multi-Channel Wireless HDMI Extender Kit 1080p - 50m User's Guide

TeamWork Kits Installation Guide

PASS. Professional Audience Safety System. User Manual. Pangolin Laser Systems. November 2O12

PQ-Box 100 Quick Start Instructions

Lite USER GUIDE. 3 Lite. For more information visit

LAB 1: Plotting a GM Plateau and Introduction to Statistical Distribution. A. Plotting a GM Plateau. This lab will have two sections, A and B.

DLP600M 6+1 Relay Module for Heating and Cooling Plants

USER MANUAL. VP-427 HDBaseT to HDMI Receiver/Scaler MODEL: P/N: Rev 5

PXL2470MW LED LCD Monitor

PRECAUTIONS CONTENTS: Please follow these precautions:

CONTENT Product Introduction... 2 Packing Configuration...3 Hardware Orientation... 4 Front Panel... 4 Back Panel... 6 Using Your Product... 7 Content

TRUCOLOUR. 4x4 Video Matrix with HDBaseT Outputs INSTALLATION GUIDE

2013, 2014 Hewlett-Packard Development Company, L.P.

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

User s Manual. Digital Media Converter Package Part #: DL-HDCAT-WP

COLOR TFT LCD MONITOR WITH MULTI-TOUCH FUNCTION Manual

UNDER TABLE 4X1 HDMI SWITCHER

DVB-LR10. Compatible with Land Rover touch-screen navigation systems version 2

Hardware Setup. HP Dual TV Tuner/Digital Video Recorder. Document Part Number:

DVB-C25. Compatible with navigation systems Mercedes Benz Comand 2.5

PROFESSIONAL D-ILA PROJECTOR DLA-G11

TABLE OF CONTENTS Important Safety Instructions Package Content Setting Up the Display Trouble shooting Specifications Product Dimensions

PROFESSIONAL D-ILA PROJECTOR DLA-G11

SMART CLASSix 24/48 UTP Patch Panels -

CytoFLEX Flow Cytometer Quick Start Guide

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

DH551C/DH550C/DL550C Double Sided Display User Manual

SmartSwitch TM. Wide View LCD 36 x 24 Pushbutton DISTINCTIVE CHARACTERISTICS PART NUMBER & DESCRIPTION

DT1-PCM21. for Porsche PCM2.1 navigation systems

MONOPRICE. Blackbird 4K Pro HDBaseT Extender Kit. User's Manual P/N 21609

Transcription:

MB5 Multibeam Activity Monitor The MB5 Multibeam Activity Monitor measures the complete locomotor activity of 16 individual flies, each in a separate tube. 17 independent infrared beams bisect each tube from top to bottom, allowing the unit to record any movement at any location within the 51mm of active length of each tube. As a fly walks back and forth within its tube, it interrupts these 17 beams in sequence, providing a high-fidelity record of where and when it moved within the tube. In a typical experiment, an agar/sucrose food mixture is placed into one end of each tube, followed by the fly, and followed by a cotton plug in the open end. The 16 tubes are inserted into holes in the monitor case, and centered. Over the course of the experiment, which may last for days or weeks, the counting circuits continuously monitor the activity in each tube, and at periodic intervals, upload their movement record to the host computer for storage and analysis. This daily record provides a good measure of both the intensity of locomotor activity, its location within the tube, and the relative periods of sleep or rest. The multiple beams for each tube allow the unit to record not only beam crossings (counts), but also beam-to-beam transitions (moves), position, beam occupancy (dwell), and length of inactivity (rest.) These detailed measurements may be recorded every second for maximum resolution, and because the fly is always in one of the 17 beams, all movement is captured precisely. Applications for this unit include assays of position preference, climbing ability, and lowmobility, where multiple beams insure accurate movement capture at any location within the tube. The MB5 uses the PSIU24 Power Supply Unit and the DAMSystemMB data collection software, to which up to 32 units may be simultaneously connected (each recording at 1-second if so selected.) MB5 Features 16 tubes of 5, 7, or 10mm diameter, 80mm length 17 independent beams cover each tube completely, recording all activity along 51mm of active tube length Output data types include Counts, Moves, Dwell, Position, and Rest 1-second reading interval for up to 32 monitors per system Consistent operation in bright room light or darkness Tubes may be horizontal or vertical Specifications Dimensions: 18.5 x 2.5 x 2.5 (470 x 64 x 64 mm LWH), tube spacing 1 (25mm) Mass: 0.8 kg without tubes Requires PSIU24 Power Supply Unit, 32 monitors per system max Data collection via DAMSystemMB software (not PSIU9/DAMSystem3) Interconnect: 6-wire, 6 position, RJ-11 modular telephone line jack, SPLT8 splitter Operating environment: normal laboratory, non-condensing TRIKINETICS TriKinetics Inc USA 1/

Notes 1. The multibeam monitor requires use of the PSIU24 Power Supply Interface Unit, PS24 Power Supply, and CAB6 cables. It is not compatible with the PSIU9 Power Supply Interface or its cables and monitors, and should not be connected to them. 2. The DAMSystemMB collection software should be used to acquire data from multibeam monitors, up to 32 simultaneously. Single-beam monitors such as the DAM2 or LAM25 are not compatible with this software, and will not work with it. 3. The 16 tubes of the MB5 monitor are numbered 1-16 as shown on the white mask plate. The 17 IR beams for each tube are numbered 1-17 from left to right, and are separated by 3mm. Thus the entire 51mm of exposed tube between the side plates is covered by the multiple beams, and fly movement anywhere along this length will be detected and registered. 4. Activity counts are registered independently at each beam position for each tube, and thus multiple flies in a tube will generate counts at separate beam positions simultaneously. If only a single fly is loaded into each tube, then activity counts will occur in only a single beam channel, and the fly position will be registered as the last beam to count. 5. To compare results with those from single-beam monitors such as the DAM2, extract channel 9, the center of the 17 beams, from the counts tube file. The results should be identical. 6. Counts are registered by each beam as the fly enters the beam. If the fly moves into the beam and sits, only a single count will be accumulated, but if the fly moves around in the beam, multiple counts may be recorded in succession. 7. Moves are registered only when the fly repositions from one beam to the next. Activity which occurs within a beam will be ignored until the fly moves to an adjacent beam. 8. Dwell data builds a simple histogram for each tube of the fly position at each second over the course of a reading. Such data reveals the position preference over time within the tube. 9. The Rest column increments each second for each tube, and is reset to 0 when a move occurs. Thus Rest indicates the number of seconds since the last detected move. Tubes We supply 5mm tubes in Corning Pyrex glass and polycarbonate plastic. While the 65mm tube length will work, the 80mm length is recommended for this unit. Both materials are transparent, and may be washed and autoclaved for cleanliness and sterility. Fly Food A food mixture must be placed into one end of each tube to sustain the fly over the course of a multi-day experiment. Many recipes are reported in the literature, but a simple one which works is as follows: 100 ml water 5g sucrose crystals 2g agar powder Combine the ingredients in a glass beaker, and bring carefully to a boil using a hot plate or microwave oven. When the solids are completely dissolved, pour the solution slowly down the side of another glass beaker containing the tubes standing on end, to a level of about 15mm deep. Allow the mixture to cool and solidify. Carefully remove the tubes from the agar matrix, TriKinetics Inc USA 2/

sealing the tops with a finger to retain the food, and wipe them clean. Then seal the food end of each tube with either a quick dip in melted paraffin wax or a plastic cap to prevent desiccation. The flies may now be loaded, one into the open end of each tube, and the tubes then plugged with cotton. System Setup 1. Download and install the USB driver from the TriKinetics web site. 2. Connect the PSIU24 to its PS24 power supply, and connect the USB cable from the PSIU24 to a port on the data collection computer (Macintosh or Windows PC.) Verify that the PSIU green led is on. 3. Download the DAMSystemMB data collection software application from the TriKinetics web site, and place it into a separate folder on the hard drive. 4. Launch the application, and click on Preferences. 5. Select the Serial Port corresponding to the PSIU USB connection, most likely the last one. Verify that the monitor status boxes are red and not black. 6. Select the reading interval, monitor range, and output file options. 7. Connect the multibeam monitor(s) to the PSIU24 using the 6-conductor phone cables provided. Verify that the status box for each monitor turns from red to green. 8. Load 5x65 or 5x80mm tubes containing flies into the 16 positions of each monitor by inserting the tubes from one side, through the monitor, and out the other side. Beams 1 and 17 graze the 2 sides of the monitor case at each tube position, so cotton or food in the tube ends should just barely, if at all, extend into the tube interior beyond the monitor sides. No harm will come from blocking one or more of the 17 beams, just no counts will be recorded at that position. 9. If flies are allowed to roam beyond the monitor sides, they clearly will be out of the detection range of the IR beams, and will not be counted. The current position will remain accurate. Data file management Monitor data is saved in the individual Monitor text files in the DAMSystem4Data folder. This folder resides in the same directory with the DAMSystem4 application, as does the DAMSystem4Settings file and the DAMSystem4Log file. All of these files are automatically generated by the program when necessary. At the conclusion of an experiment, the relevant Monitor files (perhaps only a few of the total) should be moved (drag or cut/paste) out of the DAMSystem4Data folder and into another folder on the computer. This will effectively terminate the data collection, for at the next reading the program will create new Monitor files for these monitors, and begin writing new data into them. Thus the files just moved will contain the activity records for the experiment just ended, and a new set of files will begin for the next one. The moved monitor files, now disconnected from the data collection process by being out of the DAMSystem4Data folder, may be transferred to another computer for archival storage, FileScan, and analysis or plotting. TriKinetics Inc USA 3/

MultiBeam Data Output Format Multibeam data is saved into 42-column tab-delimited Monitor text files, similar in layout to those of the DAMSystem3 monitors. Each selected output data type in the Preferences window will cause one or more lines of text to be written to the monitor file at each reading. Selections in the Monitor column generate only a single row at each reading, and contain summary data for each tube (count totals, move totals, position.) Selections in the Tube column generate one 42-column output row per tube, and therefore contain the full-fidelity data for each tube (counts, moves, dwell at each beam position.) All data rows for each monitor are written to a single Monitor file at each reading. The FileScan application can be used at the conclusion of an experiment to separate the individual data types within the monitor file into distinct files for analysis (counts, moves, dwell, position.) Monitor File: Header Columns - common to all data types Index Column 1 Incremented with each reading, 1 at program launch Date at reading Column 2 DD MMM YY Time at reading Column 3 HH:MM:SS Monitor Status Column 4 1 Valid data status green 51 no monitor data received status red 50 no connection to PSIU status black Extras Column 5 Number of extra readings, if any, consolidated by Filescan Monitor number Column 6 1-255 Tube number Column 7 1-32 or 0 if monitor row Data type Column 8 Mv = moves, Ct = Counts, Pn = Positions, Dw = Dwell Column 9 unused Light Sensor Column 10 1 = On, 0 = Off (not present in all units) Monitor File: Data columns - specific to each output data type Monitor rows contain summary data for all tubes in a single row Monitor Counts Columns 11-42 Total counts for each tube Monitor Moves Columns 11-42 Total moves for each tube Monitor Positions Columns 11-42 Position for each tube Tube rows contain complete data for each tube in a separate row Tube Counts Column 11 Position Column 12 Total counts for tube Column 13-42 Counts in each beam Tube Moves Column 11 Position Column 12 Total moves for tube Column 13-29 Moves in each beam Column 30 Rest for tube (seconds since move) Column 31-42 unused Tube Dwell Column 11 Position Column 12 Total dwell (seconds) Column 13-42 Dwell in each beam (seconds) Columns will contain 0 if unused. TriKinetics Inc USA 4/

MultiBeam FileScan The FileScan program will properly manage multibeam data files, and may be used to scan for errors, consolidate bins, select start and stop bins, etc. There are output file options for each monitor and tube data type, as well as the legacy channel format for monitor counts. Monitor Files Tube Files 1 output file per monitor, 42 columns, Monitor rows only Multiple output files per monitor, 1 for each tube, 42 columns each Channel Files 32 output files per monitor, 1 column each from columns 11-42 of monitor counts rows Precautions Beware of operation in proximity to incandescent light, where stray infrared illumination can easily interfere with the exposed detectors. Perform an empty-tube run to verify zero counts prior to operation with live specimens. Beware of liquid spills onto the green circuit boards. Unplug the unit immediately if water or any liquid drips inside, and dry thoroughly in a warm (40C) oven prior to reuse. Data Collection Software This sample output shows all 16 flies quiescent for the number of seconds in the rest column, with their current position shown in red. The fly in tube 16 moved 30 seconds ago into beam 13, after transiting from beam 1 to beam 17 and then back to beam 13 where it now sits. DAMSystemMB Data Collection Software TriKinetics Inc USA 5/