Plug-in modules for total pressure gauges and controllers TPG 300 and IMG 300

Similar documents
ITER Product Catalogue. Total Pressure Measurement V Page 1 / 15

ITER Product Catalog Total Pressure Measurement. ITER Product Catalogue Total Pressure Measurement V Page 1 / 15

Operating manual incl. Declaration of conformity

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Bayard-Alpert Pirani Gauge

3 Cleaning. 4 Technical data

Signet 2250 Hydrostatic Level Sensor


IONIVAC Transmitter ITR 90

Single Point Flow Monitor SW118 SW119

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

D Issue G. Instruction Manual. Wide Range Gauge

Vacuum measurement and control units

LAUREL ELECTRONICS, INC.

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

8D with High Frequency Coaxial Contact

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

SUPPLEMENTARY INFORMATION

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DMP 331i / DMP 333i LMP 331 i

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Inductive sensor NI3-EG08K-Y1-H1341

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

P-2 Installing the monitor (continued) Carry out as necessary

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Emergency lighting units EM powerled

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

Linear flow controls VFC Linear flow controls with actuator IFC

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

User Manual CVA3. HDMI Audio Decoder. All Rights Reserved. Version: CVA3_2016V1.0

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

Emergency lighting units EM powerled

Inductive sensor With analog output BI15-M30-LI-EXI

PATCH PANEL Easy Patch INSTRUCTION MANUAL

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

VK-P10SE WARRANTY REGISTRATION FORM

LED Driver Compact dimming

SCALE & WEIGHT DISPLAYS

Atlona HDBaseT-Lite Transmitter over Single CAT5e/6/7

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

User Manual TL-2X1-HDVC 2x1 HDMI & VGA Switcher with Control All Rights Reserved Version: TL-2X1-HDVC_160630

Model KT 53 Cooling incubators with thermoelectric cooling

EGM Einthoven Goldberger Module Type 701

32 Channel CPCI Board User Manual

user guide SLX-111 also available: SLX-100, SLX-214 transmitter & receiver pair tel: +44 (0) ,

Model Number Structure

Mechanical flow switch for On/Off control

ODW-621. RS-232 Point-to-point applications

Electronic converter for level transmitters MT03L Instructions manual

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

Contents. Instruction Manual T-Rex Page 2 of 16 Release 1.01

Precision TNC Coaxial Calibration Kit

Long Range Wireless HDMI/SDI HD Video Transmission Suite LINK-MI LM-SWHD01. User manual

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

LED Driver Linear / area fixed output

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

Broadcast A/V Division VAC-HT12-KIT. 4K/UHD/HD/SD HDBaseT Extender Kit Video, Power, and Control over one CAT cable. User Manual

TELEDYNE HASTINGS INSTRUMENTS

K3NX Process Meter OPERATION MANUAL

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

AEQ TH-03 Digital Hybrid of 1 (TH-03.1) or 2 lines (TH-03.2) with Frequency Extender

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

Industriefunkuhren. Technical Manual. Model 7248/7248RC. Fibre Optic Converter Board ENGLISH

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

USER S MANUAL. FX2N-8AD Analog input block

AC diagonal module Ø 200 mm

LED control gear Compact fixed output

Product Data Sheet 8506 VW-691

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

User manual. Long Range Wireless HDMI/SDI HD Video Transmission Suite

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

Trusted 40 Channel 120 Vac Digital Input FTA

BNCpro for 3G and Ultra-HD/4K

Process Transmitter RMA 422

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

Gear Pump Units For single-line centralized lubrication systems

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Solid-State Digital Timer

KACO-display. Wireless Solar Monitoring System. Operating Instructions KACO-display. full of energy...

Product Data Sheet 4656 EZ

MT03A Electronic converter for flow rate transmitters

Transcription:

Operating manual Plug-in modules for total pressure gauges and controllers TPG 300 and IMG 300 Installation Operation Maintenance Technical data BG 800 34 BE / C (9806) 1

Table of contents 1 Safety 4 1.1 Safety information 4 1. Explanation of symbols 4 1.3 General stipulations 4 Description 5.1 Pirani measurement boards 5. Cold cathode measurement boards 5.3 Pirani- / cold cathode measurement boards 5.4 Interface boards 5.5 Pirani measurement 5.6 Cold cathode measurement 5 3 Installation 6 3.1 Installing / removing plug-in modules 7 3. Connecting the Pirani gauge 7 3.3 Connecting the cold cathode gauge 8 3.4 Connecting the <OUTPUT> analog signal 9 3.5 Connecting the <CONTROL> analog signals 10 3.6 Connecting the relays of the IF 300A 11 3.7 Connecting the relays of the IF 300B 11 3.8 Connecting the relays of the IF 300C 1 3.9 Connecting the RS-3-C interface to the IF 300A 13 3.10 Connecting the RS-3-C interface to the IF 300B 14 3.11 Connecting the RS-4 interface to the IF 300C 16 4 Adjustment 17 4.1 Adjusting the Pirani measurement circuit 17 5 Technical data 18 5.1 Pirani measurement boards 18 5. Cold cathode measurement boards 19 5.3 Pirani / cold cathode measurement boards 0 5.4 Interface boards 6 Troubleshooting 4 6.1 Installation problems 4 6. Operating and adjustment problems 4 6.3 Defects 5 6.4 Problems with the RS-3-C interface 5 6.5 Problems with the RS-4 interface 6 7 Accessories 7 7.1 Gauges 7 7. Measurement cable 8 7.3 Accessories for interface boards 3 8 Spare parts 33 8.1 Measurement boards 33 8. Interface boards 34 Appendix 35 A: Output signals of the measurement boards 35 B: Gas type dependence 37 BG 800 34 BE / C (9806) SK 300

The present documentation describes the plug-in modules for the total pressure gauges and controllers TPG 300 and IMG 300 and supplements the manual of the correspondingly configured pressure gauge. Validity This manual applies to plug-in modules with part number BG 546 90 -T (PI 300D) BG 549 1 -T (PI 300DL) BG 549 14 -T (PI 300DN) BG 549 16 -T (PI 300DLN) BG 441 170 -T (PE 300C9) BG 441 61 -T (PE 300C10) BG 441 6 -T (PE 300T10) BG 441 63 -T (PE 300T11) BG 441 375 -T (PE 300DC9) BG 441 350 -T (PE 300DT9) BG 441 000 -T (CP 300C9) BG 441 111 -T (CP 300T9L) BG 441 114 -T (CP 300C10) BG 441 116 -T (CP 300T10) BG 441 143 -T (CP 300T10L) BG 441 080 -T (CP 300T11) BG 441 10 -T (CP 300T11L) BG 441 110 -T (CP 300C9N) BG 441 11 -T (CP 300T9LN) BG 441 115 -T (CP 300C10N) BG 441 130 -T (IF 300A) BG 441 50 -T (IF 300B) BG 441 390 -T (IF 300C) The part number can be taken from the nameplate. The functions described as well as the illustrations and data contained in this manual are subject to change without notice. BG 800 34 BE / C (9806) SK 300 3

1 Safety 1.1 Safety information a) Take the necessary precautions when doing installation work. It may be necessary implement additional protective measures in the system. b) Before connecting any external elements, check that they are compatible with the technical data in this document. c) Take the necessary precautions when doing maintenance or repair work. Specialists: This work may only be carried out by persons with suitable technical training and the necessary experience. Waiting, reaction time, duration of test <... > Marking See page... 1. Explanation of symbols DANGER: Information on preventing any kind of personal injury or extensive equipment damage. CAUTION: Special information on damage prevention. NOTE: Special information on cost-effective use. 1.3 General stipulations Since the individual components are delicate, appropriate measures must be taken to protect them from static electricity. Store modules in antistatic bags or containers. Damage resulting from incorrect handling may lead to a revocation of the guarantee. Balzers accepts no responsibility nor warranty if the user or third parties utilize the product not according to the defined use make any kind of changes (modifications, alterations, etc.) to the product. BG 800 34 BE / C (9806) SK 300 4

Description.1 Pirani measurement boards Pirani boards have tow independent medium vacuum measurement circuits, each with one gauge cable connector, two trimmer potentiometers and one analog signal output. When the control unit is on, the Pirani measurement circuits are in continuous operation. The analog signals are constantly available, independent of what is shown on the pressure display.. Cold cathode measurement boards Cold cathode measurement boards for the measurement of high and ultra high vacuum contain one or two measurement circuits, each with one gauge cable connector and one analog signal output. When the gauge is turned on, the analog signals are constantly available, independent of what is shown on the pressure display. Measurement boards for the range of 10-10 and 10-11 mbar and those with two measurement circuits contain special electronics to limit the measurement current to 100 µa, a feature that considerably extends the lifetime of the gauge..3 Pirani- / cold cathode measurement boards As the name indicates, these are combined boards containing one Pirani and one cold cathode measurement circuit each. They have the same characteristics as the boards described above..4 Interface boards Three types of interface boards are available: Two contain an RS-3-C interface, one an RS-4 interface. All three types have five relays with one floating changeover contact each. The main difference between these three boards is the switching voltage required for the relays and the type of interface port..5 Pirani measurement Within certain limits the thermal conductivity of gases is a function of the pressure. Pirani thermal conductivity vacuum gauges exploit this phenomenon for pressure measurements. The measurement element consists of a thin filament with a high temperature coefficient. The resistance of the wire and consequently its temperature are maintained at a constant value by means of a suitable control circuit. The electrical power supplied to the filament is, therefore, a measure of the thermal conductivity and consequently the gas pressure..6 Cold cathode measurement The current flowing in a self-sustained gas discharge with a cold cathode (similar to Penning) depends on the applied voltage, the gas composition, and the pressure. A magnetic field that penetrates the measurement chamber has the effect that the electrons move along a spiral trajectory from the cathode to the anode and thereby cause even at low gas densities a sufficient number of ionizing impacts for maintaining the discharge. If (with a known gas type) the anode voltage and magnetic field are kept constant, the discharge current is a measure of the pressure. BG 800 34 BE / C (9806) SK 300 5

3 Installation General Use screened cables only (connect screen to barrel of connector). If both ends of the screen are connected to ground, compensating currents must be prevented (e.g. by connecting all involved units to a common power distributor). Interface board Connecting the RS-3-C interface Installing / removing plug-in modules Connecting the relays IF 300A 7 11 13 IF 300B 7 11 14 IF 300C 7 1 16 Connecting the RS-4 interface Measurement board PI 300D PI 300DL PI 300DN PI 300DLN PE 300C9 PE 300C10 PE 300T10 PE 300T11 Connecting the Pirani gauge Installing / removing plug-in modules 7 7 9 7 8 9 PE 300DC9 PE 300DT9 7 8 10 CP 300C9 CP 300C9N CP 300C10 CP 300C10N CP 300T9L CP 300T9LN CP 300T10 CP 300T10L CP 300T11 CP 300T11L 7 7 8 9 7 7 8 9 Connecting the analog signal Connecting the cold cathode gauge BG 800 34 BE / C (9806) SK 300 6

3.1 Installing / removing plug-in modules 3. Connecting the Pirani gauge Procedure For safety reasons, vacant slots should always be covered with blank plates. Disconnect all cables from the unit before installing / removing any plug-in modules. Modules should only be handled on an ESD protected bench. Switch off the unit and wait one minute Remove all cables (power cable last) Unscrew the blind plate / plug-in module Insert / remove plug-in module Screw on the plug-in module / blind plate Connect the cables (mains cable first) Switch on the unit again Additional protective measures must be taken if certain processes in the vacuum system (e.g. flashovers) can cause hazardous voltages on the gauge terminals. Although the gauge cables are screened, they should not be routed in parallel to lines producing strong noise. Connect the gauge to the <TPR> connector on the rear panel. The connectors are locked so that they cannot be separated accidentally. If the cable length is <100 m, the module for short cables should preferably be used, otherwise the adjustment becomes more difficult. For gauge cables >100 m the version for long cables should be used. To ensure correct operation, check that the screws of the plug-in modules are tightened. BG 800 34 BE / C (9806) SK 300 7

3.3 Connecting the cold cathode gauge Additional protective measures must be taken if certain processes in the vacuum system (e.g. flashovers) can cause hazardous voltages on the gauge terminals. Although the gauge cables are screened, they should not be routed in parallel to lines producing strong noise. Connect the gauge to the <IKR> connector. Coaxial cables normally suffice. The following diagram indicates the conditions under which a triaxial cable is required. The maximum length of 100 m for coaxial cables is specified by EN 61010. Greater lengths are not admissible without additional protective measures. If the gauge is not grounded via the vacuum chamber, it must be grounded separately. Pressure [mbar] 5 10 9 10-7 8 6 4 10-8 8 6 4 10 9 8 6 4 10 10 8 6 4 Coaxial cable Triaxial cable 10 11 4 6 10 4 6 100 4 500 Cable length [m] BG 800 34 BE / C (9806) SK 300 8

3.4 Connecting the <OUTPUT> analog signal If the cable length is >100 m (only admissible with triaxial cable), the connectors must be protected against unintentional separation and contact of the center conductor. The cable must only be plugged in or detached while the unit is switched off. (except for PE 300DC9 and PE 300DT9) Each measurement circuit is equipped with an analog signal output. Matching connectors are included with each measurement module. unlock lock + OUTPUT 0... 10 V Use open ended wrench, span of jaw 17 mm Separate connector Protection against unintentional separation of the triaxial connector BG 800 34 BE / C (9806) SK 300 9

3.5 Connecting the <CONTROL> analog signals (only for PE 300DC9 and PE 300DT9) Each measurement circuit is equipped with a control input and an analog signal output. Matching connectors are included with each measurement module. External switching on / off of the measurement circuit There are various ways to switch a measurement circuit on / off: manually automatically externally via a contact on the <control> connection 4, 5 CONTROL 4, 5 switch logic 5 4 3 1 7 6 Screen Pin assignment Pin 1 Analog GND IKR 1 Pin Digital GND Pin 3 Analog GND Pin 4 IKR ON 1 Pin 5 IKR ON Pin 6 Analog Output Pin 7 Analog Output Housing Screen Switch on the gauge manually or automatically before initiating gauge control via an external input. BG 800 34 BE / C (9806) SK 300 10

3.6 Connecting the relays of the IF 300A Pin assignment The relay connector on the rear of the IF 300A has the following pin assignment: 5HOD\Ã 6ZLWFKLQJÃIXQFWLRQÃ 5HOD\Ã 6ZLWFKLQJÃIXQFWLRQÃ 5HOD\Ã 6ZLWFKLQJÃIXQFWLRQÃ 5HOD\Ã 6ZLWFKLQJÃIXQFWLRQÃ 5HOD\Ã (UURUÃVWDWXV 6FUHHQ IF 300A 3.7 Connecting the relays of the IF 300B Pin assignment The relay connector on the rear of the IF 300B has the following pin assignment: (It is not necessary to use screened cables.) 5HOD\Ã 6ZLWFKLQJÃIXQFWLRQÃ 5HOD\Ã 6ZLWFKLQJÃIXQFWLRQÃ 5HOD\Ã 6ZLWFKLQJÃIXQFWLRQÃ 5HOD\Ã 6ZLWFKLQJÃIXQFWLRQÃ 5HOD\Ã (UURUÃVWDWXV IF 300B &RQWDFVÃLQÃUHVWÃSRVLWLRQ 'HVLJQDWLRQÃRIÃFRQWDFW &RQWDFWVÃLQÃUHVWÃSRVLWLRQ 'HVLJQDWLRQÃRIÃFRQWDFW The connectors may only be wired, mounted, plugged in, and unplugged in de-energized condition. BG 800 34 BE / C (9806) SK 300 11

At voltages <50 V insulated blade receptacles 4.8 0.8 mm may be used. However, also in this case we recommend the use of the relay connector because it permits fast separation of the connection as well as strain relief. Always use the relay connector at voltages 50 V ( 3) for safety reasons. 3.8 Connecting the relays of the IF 300C Pin assignment The relay connector on the rear of the IF 300C has the following pin assignment: Mount the enclosed ferrite clamp In order to reduce the electromagnetic interference. 5HOD\Ã 6ZLWFKLQJÃIXQFWLRQÃ IF 300C 5HOD\Ã 6ZLWFKLQJÃIXQFWLRQÃ 5HOD\Ã 6ZLWFKLQJÃIXQFWLRQÃ 5HOD\Ã 6ZLWFKLQJÃIXQFWLRQÃ 5HOD\Ã (UURUÃVWDWXV 6FUHHQ &RQWDFWVÃLQÃUHVWÃSRVLWLRQ 'HVLJQDWLRQÃRIÃFRQWDFW BG 800 34 BE / C (9806) SK 300 1

3.9 Connecting the RS-3-C interface to the IF 300A Pin assignment The interface connector on the rear of the IF 300A has the following pin assignment: IF 300A 7;' 7;' 5;' 5;' 6Ã*1' 6Ã*1' &RPSXWHU 576 &76 6FUHHQ '75 '65 '&' View A: Pin 3 Pin Pin 5 Housing Transmitted data TXD *) Received data RXD *) Signal common Screen *) reference point = pressure gauge BG 800 34 BE / C (9806) SK 300 13

3.10 Connecting the RS-3-C interface to the IF 300B Interface cable If you intend to use the RS-3-C interface, you must first install the interface cable in the specified sequence: Detail: Connection of screen BG 800 34 BE / C (9806) SK 300 14

Pin assignment The interface connector on the rear of the IF 300B has the following pin assignment: IF 300B 7;' 7;' 5;' 5;' 6Ã*1' 6Ã*1' &RPSXWHU 576 6FUHHQ &76 '75 $ '65 '&' View A: Pin 1 Pin Pin 3 Pin 7 Housing Protective ground Transmitted data TXD *) Received data RXD *) Signal common Screen *) reference point = pressure gauge BG 800 34 BE / C (9806) SK 300 15

3.11 Connecting the RS-4 interface to the IF 300C Pin assignment The interface connector on the rear of the IF 300C has the following pin assignment: 3Ã*1' 6Ã*1' 5;à 5;ò 7;à 7;ò 6FUHHQ IF 300C $ View A: Pin 1 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Housing Protective ground Signal common Received data + Received data Transmitted data + Transmitted data Screen *) reference point = pressure gauge BG 800 34 BE / C (9806) SK 300 16

4 Adjustment Pirani measurement circuits are factory-adjusted to the standard gauge. Due to manufacturing tolerances, contamination of the gauges, and different cable lengths, deviations are inevitable. Cold cathode measurement circuits are factory-adjusted and require no readjustment. 4.1 Adjusting the Pirani measurement circuit ATM HIGH VAC + OUTPUT 0... 10 V Two trimmer potentiometers are available for compensating the gauge tolerances, gauge contamination, or different cable lengths, within certain limits. The adjustment should only be performed after the equipment has attained operating temperature (after 10 min.). Pirani measurement circuits for cable lengths < 100 m PI 300D, PI 300DN CP 300C9, CP 300C10, CP 300T10, CP 300T11, CP 300C9N, CP 300C10N Adjustment at high vacuum With gauge connected, lower the vacuum chamber pressure to <1 10-4 mbar Select the measurement circuit to be adjusted (SENSORmode) With the <HIGH VAC> potentiometer adjust the display to 8.0 10-4 mbar Turn the potentiometer clockwise by 90 «ur 10-4» should now be displayed Adjustment at atmospheric pressure Expose the gauge to atmospheric pressure (vent the vacuum chamber) Turn the <ATM> potentiometer to obtain a reading of 1.0 10 3 mbar Decrease the pressure to <1 10-4 mbar Check the high vacuum reading and readjust, if necessary Pirani measurement circuit for cable lengths > 100 m PI 300DL, PI 300DLN CP 300T9L, CP 300T10L, CP 300T11L, CP 300T9LN Same procedure as described above, however starting with atmospheric pressure. BG 800 34 BE / C (9806) SK 300 17

5 Technical data 5.1 Pirani measurement boards Plug-in module PI 300D PI 300DL PI 300DN PI 300DLN Number of measurement circuits Measurement range 1 ) from 1000 mbar... mbar 8 10-4 8 10-4 8 10-4 8 10-4 Measurement line length, max. m 100 500 100 500 Signal output Measured value, analog Error message (Error) Current, max. Output resistance Reaction time (10 Ø 90%) for sudden pressure change < 10-3... 10 3 mbar 10 3... < 10 3 mbar Connection, equipment side TPR gauge V V ma Ω ms ms socket 0... +10 > 11.5 400 < 50 < 600 Amphenol C91E 6 pin 0... +10 > 11.5 400 < 50 < 600 Amphenol C91E 6 pin 0... +10 > 11.5 400 < 50 < 600 Amphenol C91E 6 pin Signal output (laboratory mm sockets) Weight kg 0.14 0.14 0.14 0.14 0... +10 > 11.5 400 < 50 < 600 Amphenol C91E 6 pin 1 ) N equivalent BG 800 34 BE / C (9806) SK 300 18

5. Cold cathode measurement boards Plug-in module PE 300C9 PE 300C10 PE 300T10 PE 300T11 PE 300DC9 PE 300DT9 Number of measurement circuits 1 1 1 1 Measurement range 1 ) from 5 10-3 mbar... mbar 5 10-9 1 10-10 1 10-10 1 10-11 1 10-9 1 10-9 Measurement line length, max. m 60 )... 100 60 )... 100 500 500 60 )... 100 500 Power supply of gauge Operating voltage Measurement current, max. Signal output Measured value, analog Error message (Error) Current, max. Output resistance kv µa V V ma Ω 3.3 600 0... +10 > 11.5 400 3.3 100 0... +10 > 11.5 400 3.3 100 0... +10 > 11.5 400 3.3 100 0... +10 > 11.5 400 3.3 100 0... +10 > 11.5 400 Reaction time (10 Ø 90%) for sudden pressure change < 10-9... 10 3 mbar ms < 10 < 50 < 50 < 50 < 0 < 0 Connection, equipment side 3.3 100 0... +10 > 11.5 400 IKR gauge Signal output socket socket SHV coaxial mm SHV coaxial mm triaxial mm triaxial mm SHV coaxial Amphenol C91E 7 pin triaxial Amphenol C91E 7 pin Weight kg 0.17 0. 0.4 0.4 0.6 0.3 1 ) N equivalent ) when using the lower measurement range limit ( 8) BG 800 34 BE / C (9806) SK 300 19

5.3 Pirani / cold cathode measurement boards Plug-in module CP 300C9 CP 300C9N CP 300T9L CP 300T9LN CP 300C10 CP 300C10N CP 300T10 CP 300T10L CP 300T11 CP 300T11L Number of measurement circuits 1 each 1 each 1 each 1 each 1 each 1 each 1 each Measurement range 1 ) Pirani, 1000 mbar... Cold cathode, 5 10-3 mbar... Measurement line length Pirani, max. Cold cathode, max. Power supply of IKR gauge Operating voltage Measurement current, max. Signal output Measurement value, analog Error message (Error) Current, max. Output resistance Reaction time (10 Ø 90%) for sudden pressure change Pirani < 10-3... 10 3 mbar 10 3... < 10 3 mbar mbar mbar m m kv µa V V ma Ω ms ms 8 10-4 8 10-4 8 10-4 8 10-4 8 10-4 8 10-4 8 10-4 5 10-9 5 10-9 1 10-10 1 10-10 1 10-10 1 10-11 100 60 )... 100 3.3 600 0... +10 > 11.5 400 < 50 < 600 500 500 3.3 600 0... +10 > 11.5 400 < 50 < 600 100 60 )... 100 3.3 100 0... +10 > 11.5 400 < 50 < 600 100 500 3.3 100 0... +10 > 11.5 400 < 50 < 600 500 500 3.3 100 0... +10 > 11.5 400 < 50 < 600 100 500 3.3 100 0... +10 > 11.5 400 < 50 < 600 1 10-11 500 500 3.3 100 0... +10 > 11.5 400 < 50 < 600 Cold cathode 10-9... 10 3 mbar ms < 10 < 10 < 50 < 50 < 50 < 50 < 50 BG 800 34 BE / C (9806) SK 300 0

Plug-in module Connection, equipment side TPR gauge socket CP 300C9 CP 300C9N Amphenol C91E 6 pin CP 300T9L CP 300T9LN Amphenol C91E 6 pin CP 300C10 CP 300C10N Amphenol C91E 6 pin CP 300T10 CP 300T10L CP 300T11 CP 300T11L Amphenol C91E 6 pin Amphenol C91E 6 pin Amphenol C91E 6 pin Amphenol C91E 6 pin IKR gauge Signal output (laboratory sockets) socket mm SHV coaxial SHV coaxial triaxial triaxial triaxial triaxial triaxial Weight kg 0.1 0.3 0.3 0.5 0.5 0.5 0.5 1 ) N equivalent ) When using the lower measuring range limit ( 8) BG 800 34 BE / C (9806) SK 300 1

5.4 Interface boards Plug-in module IF 300A IF 300B IF 300C Relay Number 5 5 5 Contact type 1 changeover contact each floating max. 50 V relative to other contacts and ground 1 changeover contact each floating max. 50 V relative to other contacts and ground Characteristic data AC Switching voltage, max. 50 V 50 V 50 V Switching current, max. 1.5 A 4 A 1.5 A Switching power, max. 75 VA 1000 VA 75 VA Characteristic data DC Switching current, max. Switching power, max. Switching voltages >50 V= are inadmissible for safety reasons 0.6 A at 50 V= 0.8 A at 40 V= 1.5 A at 30 V= 0.5 A at 00 V= 0.3 A at 140 V= 0.4 A at 100 V= 0.5 A at 60 V= 0.6 A at 50 V= 0.8 A at 40 V= 4.0 A at 30 V= 10 W 1 changeover contact each floating max. 50 V relative to other contacts and ground Switching voltages >50 V= are inadmissible for safety reasons 0.6 A at 50 V= 0.8 A at 40 V= 1.5 A at 30 V= BG 800 34 BE / C (9806) SK 300

Plug-in module IF 300A IF 300B IF 300C Connection, equipment side Type D-Sub connector, 15 pin, male GdsA-H, DIN 41 61, 15 pin, male D-Sub connector, 15 pin, male Connectors may only be joined or separated when not energized. Volume resistance with socket 15 mω 70 mω 15 mω Interface Type RS-3-C, asynchronous RS-3-C, asynchronous RS-4, asynchronous Baud rates 300, 100, 400, 4800, 9600 300, 100, 400, 4800, 9600 300, 100, 400, 4800, 9600 Data format ASCII 1 start bit, 8 data bits, 1 stop bit, no parity bit ASCII 1 start bit, 8 data bits, 1 stop bit, no parity bit Connection, equipment side D-Sub connector, 9 pin, male 0.4 m cable with D-Sub connector, 5 pin, male Cable length, max. 30 m 30 m 100 m Weight 0.14 kg 0.15 kg 0.14 kg ASCII 1 start bit, 8 data bits, 1 stop bit, no parity bit D-Sub connector, 9 pin, female Before connecting any external elements, check that they conform to the above technical data. BG 800 34 BE / C (9806) SK 300 3

6 Troubleshooting 6.1 Installation problems Symptom Possible cause Remedy Gauge cable cannot be connected Old IKR gauge with MHV connector Use the right cable ( 30 f.) to IKR gauge Change the connector ( & gauge) Gauge cable cannot be connected to the Gauge cable with old connector Use the right cable ( 30 ff.) measurement board Remove and replace connector ( 30 ff.) 6. Operating and adjustment problems Symptom Possible cause Remedy Pirani reading too high Pirani gauge contaminated Adjust Pirani measurement circuit ( 17) Cold cathode reading too high Connector insulation contaminated or moist Air humidity (Ø leakage current) Clean gauge ( & gauge) Replace gauge Clean insulation or replace connector Keep the air humidity low Keep the equipment in constant operation Cold cathode reading too low Cold cathode gauge contaminated Clean gauge ( & gauge) Pirani can not be adjusted Wrong combination measurement board / gauge / cable Gauge severely contaminated Select right combination according to 7 Clean or replace gauge ( & gauge) BG 800 34 BE / C (9806) SK 300 4

6.3 Defects Symptom Possible cause Remedy Cold cathode continually indicates (overrange), even though the pressure is within the measuring range Short circuit in the cold cathode cable / gauge Cold cathode measurement board defective Replace or repair the cable / gauge Replace the cold cathode measurement board ( 7) Cold cathode indicates No IKR gauge connected Connect the gauge (underrange), even though the pressure is within the measuring range Interruption in cold cathode cable Replace or repair the cable 6.4 Problems with the RS-3-C interface Cold cathode gauge defective Cold cathode measurement board defective Symptom Possible cause Remedy No communication Pins and 3 of the interface cable not crossed Wrong baud rate Wrong data format Replace the gauge ( & gauge) Replace the cold cathode measurement board ( 7) Use the cable according to 13 or 14 Match the baud rate Adhere to the format specified for the basic unit BG 800 34 BE / C (9806) SK 300 5

6.5 Problems with the RS-4 interface Symptom Possible cause Remedy No communication Wrong baud rate Match the baud rate Wrong data format Adhere to the format specified for the basic unit BG 800 34 BE / C (9806) SK 300 6

7 Accessories 7.1 Gauges Gauge suitable for measurement boards Flange Ordering number TPR 010 PI 300D PI 300DL DN 10 ISO-KF BG G0 70 TPR 017 PI 300DN PI 300DLN DN 16 ISO-KF DN 16 CF-F BG G1 70 BG G1 71 TPR 018 IKR 050 PI 300D PI 300DL PE 300C9 PE 300C10 PE 300DC9 CP 300C9 CP 300C10 CP 300C9N CP 300C10N DN 16 ISO-KF DN 16 CF-F DN 40 CF-F DN 5 ISO-KF DN 40 ISO-KF DN 40 CF-F BG G15 010 BG G15 011 BG G15 014 BG G18 500 BG G18 501 BG G18 50 IKR 060 IKR 070 PE 300C9 PE 300C10 PE 300DC9 PE 300T10 PE 300T11 PE 300DT9 CP 300C9 CP 300C10 CP 300C9N CP 300C10N CP 300T9L CP 300T9LN CP 300T10 CP 300T10L CP 300T11 CP 300T11L DN 40 ISO-KF DN 40 CF-F DN 40 ISO-KF DN 40 CF-F BG G18 753 BG G18 751 BG G0 501 BG G0 50 BG 800 34 BE / C (9806) SK 300 7

7. Measurement cables Pirani measurement cable, screened Gauge Gauge connector Length Ordering number TPR 010 BG G0 70 BG G0 71 Other cable lengths on request C91E (new) 3 m 6 m BG 548 401 -T BG 548 403 -T ZKLWH EURZQ \HOORZ JUHHQ Position Designation Quantity Ordering number 1 3 4 5 6 Cable 4 0,34 mm², screened, 80 C Connector Amphenol C91E Crimp terminal for connector C91E * ) Cable connector Amphenol C91E Sleeve terminal for connector C91E * ) Ferrite clamp High temperature cables on request 1 5 1 4 1 B 4590 198 CC B 47 715 CA B 47 841 CA B 47 755 CA B 47 846 CA B 5144 406 FH * ) Simple crimp pliers Amphenol FA0100-146 or hand crimp pliers Amphenol FA0500 with jaw FA0001-91 required. BG 800 34 BE / C (9806) SK 300 8

Gauge Gauge connector Length Ordering number TPR 017 BG G13 70 BG G13 71 TPR 018 BG G15 010 BG G15 011 BG G15 014 Other cable lengths on request LEMO LEMO 3 m 6 m 3 m 6 m BG 548 308 -T BG 548 309 -T BG 548 308 -T BG 548 309 -T ZKLWH EURZQ \HOORZ JUHHQ Position Designation Quantity Ordering number 1 3 6 7 8 Cable 4 0,34 mm², screened, 80 C Connector Amphenol C91E Crimp terminal for connector C91E * ) Cable connector LEMO FGJ.1B.304 Crimp terminal for LEMO FGJ.1B.304 * ) Ferrite clamp High temperature cable on request 1 5 1 4 1 B 4590 198 CC B 47 715 CA B 47 841 CA B 47 063 LU B 47 953 LU B 5144 406 FH * ) Simple crimp pliers Amphenol FA0100-146 or hand crimp pliers Amphenol FA0500 with jaw FA0001-91 required. BG 800 34 BE / C (9806) SK 300 9

Cold cathode measurement cable Gauge Gauge cable Length Ordering number IKR 050 BG G18 500 BG G18 501 BG G18 50 IKR 060 BG G18 751 BG G18 753 Other cable lengths on request SHV coaxial (new) SHV coaxial (new) 3 m 6 m 3 m 6 m BG 548 406 -T BG 548 407 -T BG 548 406 -T BG 548 407 -T Test voltage: 6 kv DC Position Designation Quantity Ordering number 1 Cable, coaxial, 75 Ω, 67 pf/m Coaxial connector SHV High temperature cable on request B 458 3 SE B 478 606 B9 BG 800 34 BE / C (9806) SK 300 30

Gauge Gauge connector Length Ordering number IKR 070 BG G0 501 BG G0 50 Other cable lengths on request triaxial 3 m 6 m BG 548 306 -T BG 548 317 -T Test voltage: 6 kv DC Position Designation Quantity Ordering number 3 4 Cable, triaxial, 75 Ω Triaxial connector with locking nut B 458 008 FA B 47 658 LU BG 800 34 BE / C (9806) SK 300 31

7.3 Accessories for interface boards Ordering number D-sub coupling complete, 15 pin, female for IF 300A BG 441 19 -T D-sub coupling complete, 9 pin, female for IF 300A BG 441 18 -T Relay connector complete, 15 pin, DIN 41 61 for IF 300B BG 546 999 -T Interface cable RS-3-C, 0.4m for IF 300B BG 548 93 -T D-sub coupling complete, 15 pin, female for IF 300C BG 441 19 -T D-sub connector complete, 9 pin, male for IF 300C BG 441 145 -T BG 800 34 BE / C (9806) SK 300 3

8 Spare parts 8.1 Measurement boards For gauges TPR 010, TPR 018 (tungsten filament) Dual Pirani for cables up to 100 m Dual Pirani for cables from 100 to 500 m For gauge TPR 017 (nickel filament) Dual Pirani for cables up to 100 m Dual Pirani for cables from 100 to 500 m For gauges IKR 050, IKR 060, IKR 070 Single cold cathode 5 10-9 mbar, coaxial Single cold cathode 1 10-10 mbar, coaxial Single cold cathode 1 10-10 mbar, triaxial Single cold cathode 10-11 mbar, triaxial Dual cold cathode 1 10-9 mbar, coaxial Dual cold cathode 1 10-9 mbar, triaxial For gauges TPR 010, TPR 018, IKR 050, IKR 060, IKR 070 combined (tungsten filament) Pirani / cold cathode for cables up to 100 m 5 10-9 mbar, coaxial Pirani / cold cathode for cables from 100 to 500 m 5 10-9 mbar, triaxial Pirani / cold cathode for cables up to 100 m 1 10-10 mbar, coaxial Pirani / cold cathode for cables up to 100 m 1 10-10 mbar, triaxial Pirani / cold cathode for cables from 100 to 500 m 1 10-10 mbar, triaxial Pirani / cold cathode for cables up to 100 m 10-11 mbar, triaxial Pirani / cold cathode for cables from 100 to 500 m 10-11 mbar, triaxial PI 300D PI 300DL PI 300DN PI 300DLN PE 300C9 PE 300C10 PE 300C9 PE 300C10 PE 300DC9 PE 300DT9 CP 300C9 CP 300T9L CP 300C10 CP 300T10 CP 300T10L CP 300T11 CP 300T11L Ordering number BG 546 90 -T BG 549 1 -T BG 549 14 -T BG 549 16 -T BG 441 170 -T BG 441 61 -T BG 441 6 -T BG 441 63 -T BG 441 375 -T BG 441 350 -T BG 441 000 -T BG 441 111 -T BG 441 114 -T BG 441 116 -T BG 441 143 -T BG 441 080 -T BG 441 10 -T BG 800 34 BE / C (9806) SK 300 33

For gauges TPR 017, IKR 050, IKR 060, IKR 070 combined (nickel filament) Pirani / cold cathode for cables up to 100 m 5 10-9 mbar, coaxial Pirani / cold cathode for cables from 100 to 500 m 5 10-9 mbar, triaxial Pirani / cold cathode for cables up to 100 m 1 10-10 mbar, coaxial Other measurement boards on request CP 300C9N CP 300T9LN CP 300C10N Ordering number BG 441 110 -T BG 441 11 -T BG 441 115 -T Connector Amphenol C91E, 7 pin Ferrite clamp ø6.0... 7.0 mm (PI cable) Ferrite clamp ø7.8... 8.5 mm (RS-3-C cable for IF 300B) Ferrite clamp ø9.5... 10.5 mm (relay cable for IF 300B) Cable strap Laboratory connector, gold plated, ø mm Grommet for laboratory connector, red Grommet for laboratory connector, black Ordering number B 47 107 CC B 5144 406 FH B 5144 408 FH B 5144 410 FH B 4631 761 BL B 4711 15 MA B 4711 15 N B 4711 15 NZ 8. Interface boards Relay and interface board RS-3-C 50 V Relay and interface board RS-3-C 50 V (without connection cable and connectors) Relay and interface board RS-4 50 V IF 300A IF 300B IF 300C Ordering number BG 441 130 -T BG 441 50 -T BG 441 390 -T BG 800 34 BE / C (9806) SK 300 34

Appendix A: Output signals of the measurement boards p [mbar] 10 5 10 4 10 3 10 10 1 10 0 10 1 10 10 3 10 4 0 1 3 4 5 6 7 8 9 10 11 U A [V] TPR 010 / TPR 018 with PE 300D TPR 017 with PI 300DN BG 800 34 BE / C (9806) SK 300 35

p [mbar] 10 BG 800 34 BE / C (9806) SK 300 p = 10 U 10.5 10 3 10 4 10 5

B: Gas type dependence Pirani gauges Indicated pressure (Instrument calibrated for air) p (mbar) 10 8 6 4 10 1 8 6 4 10 0 8 6 4 H He Ne Luft / Air O CO N CO Ar Freon 1 Kr Xe 10 1 8 6 4 10 8 6 4 H O-Dampf/ Water vapor 10 3 10 3 4 6 10 4 6 10 1 4 6 10 0 4 6 10 1 4 6 10 p eff (mbar) BG 800 34 BE / C (9806) SK 300 37

Cold cathode gauges Indicated pressure (Instrument calibrated for air) p (mbar) 4 10 3 8 6 4 Luft / Air O CO Xe Kr Ar N H Ne He 10 4 8 6 4 (Mean values, deviations possible depending on degree of contamination). Reference gauge: Hot cathode ionization gauge 10 5 8 6 4 10 6 8 6 4 10 7 10 7 4 6 10 6 4 6 10 5 4 6 10 4 4 6 10 3 4 6 10 p eff (mbar) BG 800 34 BE / C (9806) SK 300 38

BG 800 34 BE / C (9806) SK 300 39

Balzers Aktiengesellschaft FL 9496 Balzers Fürstentum Liechtenstein Tel (075) 388 41 11 Fax (075) 388 54 14